172 resultados para Arterial


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Thrombolysis has been shown to improve the 3-month outcome of patients with ischemic stroke, but knowledge of the long-term effect of thrombolysis is limited. METHODS: The present study compares the long-term outcome of stroke patients who were treated with intra-arterial thrombolysis (IAT) using urokinase with the outcome of patients treated with aspirin. The modified Rankin Scale (mRS) was used to assess the outcome; 173 patients treated with IAT and 261 patients treated with aspirin from the Bernese Stroke Data Bank were eligible for the study. A matching algorithm taking into account patient age and stroke severity on admission (as measured by the National Institute of Health Stroke Scale [NIHSS]) was used to assemble an IAT and an aspirin group. RESULTS: One hundred and forty-four patients treated with IAT and 147 patients treated with aspirin could be matched and included in the comparative analysis. The median NIHSS score was 14 in each group. At 2 years, 56% of the patients treated with IAT and 42% of the patients treated with aspirin achieved functional independence (mRS, 0 to 2; P=0.037). Clinical outcome was excellent (mRS, 0 to 1) in 40% of the IAT and in 24% of the aspirin patients (P=0.008). Mortality was 23% and 24%, respectively. CONCLUSIONS: The present study provides evidence for a sustained effect of IAT when assessed 2 years after the stroke.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Functional magnetic resonance imaging (fMRI) is presently either performed using blood oxygenation level-dependent (BOLD) contrast or using cerebral blood flow (CBF), measured with arterial spin labeling (ASL) technique. The present fMRI study aimed to provide practical hints to favour one method over the other. It involved three different acquisition methods during visual checkerboard stimulation on nine healthy subjects: 1) CBF contrast obtained from ASL, 2) BOLD contrast extracted from ASL and 3) BOLD contrast from Echo planar imaging. Previous findings were replicated; i) no differences between the three measurements were found in the location of the activated region; ii) differences were found in the temporal characteristics of the signals and iii) BOLD has significantly higher sensitivity than ASL perfusion. ASL fMRI was favoured when the investigation demands for perfusion and task related signal changes. BOLD fMRI is more suitable in conjunction with fast event related design.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: In selected stroke centers intra-arterial thrombolysis (IAT) is used for the treatment of acute stroke patients presenting within 6 hours of symptom onset. However, data about eligibility of acute stroke patients for IAT in clinical practice are very scarce. METHODS: We collected prospectively data on indications advising for or against IAT of 230 consecutive stroke patients in a tertiary stroke center. RESULTS: 76 patients (33.0%) presented within 3 hours, 69 (30%) between 3 and 6 hours of symptom onset and 85 (37%) later than 6 hours. Arteriography was performed in 71 patients (31%) and IAT in 46 (20%). In 11 patients no or only peripheral branch occlusions were seen on arteriography and therefore IAT was not performed. In 9 patients the ICA was occluded and barred IAT and in five anatomical or technical difficulties made IAT impossible. 72 patients presenting within 6 hours did not undergo arteriography and thrombolysis, mostly because of mild (n = 44) or rapidly improving neurological deficits (n = 13). Other reasons to withhold IAT were CT and/or clinical findings suggesting lacunar stroke due to small vessel occlusion (n = 7), limiting comorbidty (n = 7) and baseline international normalized ratio > 1.7 (n = 1). CONCLUSIONS: A third of the patients underwent diagnostic arteriography and one fifth received IAT. The most important reasons to withhold thrombolysis were presentation beyond the 6 hours time window and mild or rapidly improving symptoms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Seromas occurring around a vascular graft are a rare complication. We report a life-threatening plasma leakage that occurred through the polytetrafluoroethylene vascular prosthesis of an Impella right ventricular assist device (Impella RD [Impella Cardiosystems GmbH, Aachen, Germany]) implanted in a 62-year-old patient with acute right ventricular failure after cardiac transplantation. The leakage became progressively massive. Weaning the patient from the right ventricular assist device was not possible. The prosthesis was thus wrapped within a pericardial patch to contain the leakage. Three days later the patient could be successfully weaned and the pump was removed. The clinical evolution was favorable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Basilar artery occlusion (BAO) is an infrequent form of acute stroke, which invariably leads to death or long-term disability if not recanalized. A traditional recanalization approach based on historical controls and pathophysiological consideration is local intra-arterial thrombolysis (IAT) in eligible patients. This necessitates diagnostic evaluation and treatment in stroke centers equipped with an interventional neuroradiological service on a 24-hour basis, but its superiority to the technically simple intravenous thrombolysis (IVT) remains unproven. METHODS: We analyzed systematically published case series of substantial size reporting the outcome of BAO after IAT or IVT. RESULTS: In 420 BAO patients treated with IVT (76) and IAT (344), death or dependency were equally common: 78% (59 of 76) and 76% (260 of 344), respectively (P=0.82). Recanalization was achieved more frequently with IAT (225 of 344; 65%) than with IVT (40 of 76; 53%; P=0.05), but survival rates after IVT (38 of 76; 50%) and IAT (154 of 344; 45%) were equal (P=0.48). A total of 24% of patients treated with IAT and 22% treated with IVT reached good outcomes (P=0.82). Without recanalization, the likelihood of good outcome was close to nil (2%). CONCLUSIONS: Recanalization occurs in more than half of BAO patients treated with IAT or IVT, and 45% to 55% of survivors regain functional independence. Although improved therapy forms for BAO are necessary, hospitals not equipped for IAT may set up IVT protocols. The effect of IVT is probably not much different from the effect of IAT. IVT represents probably the best treatment that can be offered to victims of acute BAO in such hospitals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: In contrast to hypnosis, there is no surrogate parameter for analgesia in anesthetized patients. Opioids are titrated to suppress blood pressure response to noxious stimulation. The authors evaluated a novel model predictive controller for closed-loop administration of alfentanil using mean arterial blood pressure and predicted plasma alfentanil concentration (Cp Alf) as input parameters. METHODS: The authors studied 13 healthy patients scheduled to undergo minor lumbar and cervical spine surgery. After induction with propofol, alfentanil, and mivacurium and tracheal intubation, isoflurane was titrated to maintain the Bispectral Index at 55 (+/- 5), and the alfentanil administration was switched from manual to closed-loop control. The controller adjusted the alfentanil infusion rate to maintain the mean arterial blood pressure near the set-point (70 mmHg) while minimizing the Cp Alf toward the set-point plasma alfentanil concentration (Cp Alfref) (100 ng/ml). RESULTS: Two patients were excluded because of loss of arterial pressure signal and protocol violation. The alfentanil infusion was closed-loop controlled for a mean (SD) of 98.9 (1.5)% of presurgery time and 95.5 (4.3)% of surgery time. The mean (SD) end-tidal isoflurane concentrations were 0.78 (0.1) and 0.86 (0.1) vol%, the Cp Alf values were 122 (35) and 181 (58) ng/ml, and the Bispectral Index values were 51 (9) and 52 (4) before surgery and during surgery, respectively. The mean (SD) absolute deviations of mean arterial blood pressure were 7.6 (2.6) and 10.0 (4.2) mmHg (P = 0.262), and the median performance error, median absolute performance error, and wobble were 4.2 (6.2) and 8.8 (9.4)% (P = 0.002), 7.9 (3.8) and 11.8 (6.3)% (P = 0.129), and 14.5 (8.4) and 5.7 (1.2)% (P = 0.002) before surgery and during surgery, respectively. A post hoc simulation showed that the Cp Alfref decreased the predicted Cp Alf compared with mean arterial blood pressure alone. CONCLUSION: The authors' controller has a similar set-point precision as previous hypnotic controllers and provides adequate alfentanil dosing during surgery. It may help to standardize opioid dosing in research and may be a further step toward a multiple input-multiple output controller.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate selective and superselective catheter therapy of serious arterial damage associated with orthopedic surgery of the pelvis, hip joint, femur, and knee. MATERIALS AND METHODS: Between 1989 and 2005, 16 consecutive patients with arterial damage after orthopedic surgery (seven women, nine men; mean age, 62 years; age range, 21-82 y) underwent angiographic exploration. Seven patients were in hemodynamically unstable condition. Initial orthopedic procedures were iliac crest internal fixation (n = 1); total hip prosthesis (n = 3); revision of total hip prosthesis (n = 4); revision of acetabular cup prosthesis (n = 1); gamma-nailing, nail-plate fixation, or intramedullary nailing (n = 3); and total knee prosthesis (n = 4). RESULTS: Angiography showed pseudoaneurysms (n = 11), vascular lacerations with active extravasation (n = 3), and arteriovenous fistulas with extravasation (n = 2). After angiographic documentation of serious arterial injury, 14 patients were treated with a single or coaxial catheter technique in combination with coils alone, coils and polyvinyl alcohol particles, coils and Gelfoam pledgets, or Gelfoam pledgets; or balloon occlusion with isobutyl cyanoacrylate and coils. Two patients were treated with covered stents. In all, bleeding was effectively controlled in a single session in 16 patients, with immediate circulatory stabilization. Major complications included death, pulmonary embolism, and postprocedural hematoma. CONCLUSION: Selective and superselective catheter therapy may be used for effective, minimally invasive management of rare but potentially life-threatening vascular complications after orthopedic surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Digital volume pulse (DVP), a noninvasive method for indirect assessment of arterial stiffness, was not tested previously in patients with end-stage renal disease (ESRD). Therefore, we compared the DVP-derived stiffness index (SI(DVP)) with aortic pulse wave velocity (PWV) determined by means of Doppler ultrasonography in 2 groups of patients with ESRD and analyzed the correlation between SI(DVP) and comorbidity. METHODS: Photoplethysmography was performed on the index finger of the dominant hand or the hand from the nonfistula arm in 49 renal transplant (TX) recipients and 48 hemodialysis (HD) patients. Pulse curves were analyzed with computer assistance. Comorbidity was assessed by using an established index. RESULTS: The intrasubject variability of SI(DVP) was 5.7%. SI(DVP) and aortic PWV values correlated significantly (r = 0.66; P = 0.001) in patients with ESRD. SI(DVP) could not be assessed reliably in 25% and 6% of HD patients and TX recipients, respectively. Multivariate regression analyses showed that SI(DVP) increased with age in both HD patients and TX recipients (r = 0.61; P < 0.001) and with systolic blood pressure (r = 0.53; P < 0.025), mean arterial pressure (r = 0.47; P < 0.05), and pulse pressure (r = 0.52; P = 0.02) in TX recipients. Severity of comorbid status was associated highly with individual residuals of age-adjusted SI(DVP) in HD patients and TX recipients (P < 0.001). CONCLUSION: DVP allows the measurement of arterial stiffness in most, but not all, patients with ESRD. SI(DVP) values correlate with comorbidity in HD patients and TX recipients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Low cardiac output impairs the hepatic arterial buffer response (HABR). Whether this is due to low abdominal blood flow per se is not known. Dobutamine is commonly used to increase cardiac output, and it may further modify hepatosplanchnic and renal vasoregulation. We assessed the effects of isolated abdominal aortic blood flow changes and dobutamine on hepatosplanchnic and renal blood flow. Twenty-five anesthetized pigs with an abdominal aorto-aortic shunt were randomized to 2 control groups [zero (n = 6) and minimal (n = 6) shunt flow], and 2 groups with 50% reduction of abdominal blood flow and either subsequent increased abdominal blood flow by shunt reduction (n = 6) or dobutamine infusion at 5 and 10 microg kg(-1) min(-1) with constant shunt flow (n = 7). Regional (ultrasound) and local (laser Doppler) intra-abdominal blood flows were measured. The HABR was assessed during acute portal vein occlusion. Sustained low abdominal blood flow, by means of shunt activation, decreased liver, gut, and kidney blood flow similarly and reduced local microcirculatory blood flow in the jejunum. Shunt flow reduction partially restored regional blood flows but not jejunal microcirculatory blood flow. Low-but not high-dose dobutamine increased gut and celiac trunk flow whereas hepatic artery and renal blood flows remained unchanged. Neither intervention altered local blood flows. The HABR was not abolished during sustained low abdominal blood flow despite substantially reduced hepatic arterial blood flow and was not modified by dobutamine. Low-but not high-dose dobutamine redistributes blood flow toward the gut and celiac trunk. The jejunal microcirculatory flow, once impaired, is difficult to restore.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In a surfactant-depletion model of lung injury, tidal recruitment of atelectasis and changes in shunt fraction lead to large Pao2 oscillations. We investigated the effect of these oscillations on conventional arterial blood gas (ABG) results using different sampling techniques in ventilated rabbits. In each rabbit, 5 different ventilator settings were studied, 2 before saline lavage injury and 3 after lavage injury. Ventilator settings were altered according to 5 different goals for the amplitude and mean value of brachiocephalic Pao2 oscillations, as guided by a fast responding intraarterial probe. ABG collection was timed to obtain the sample at the peak or trough of the Pao2 oscillations, or over several respiratory cycles. Before lung injury, oscillations were small and sample timing did not influence Pao2. After saline lavage, when Po2 fluctuations measured by the indwelling arterial Po2 probe confirmed tidal recruitment, Pao2 by ABG was significantly higher at peak (295 +/- 130 mm Hg) compared with trough (74 +/- 15 mm Hg) or mean (125 +/- 75 mm Hg). In early, mild lung injury after saline lavage, Pao2 can vary markedly during the respiratory cycle. When atelectasis is recruited with each breath, interpretation of changes in shunt fraction, based on conventional ABG analysis, should account for potentially large respiratory variations in arterial Po2.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: This study analyzes the results of the arterial switch operation for transposition of the great arteries in member institutions of the European Congenital Heart Surgeons Association. METHODS: The records of 613 patients who underwent primary arterial switch operations in each of 19 participating institutions in the period from January 1998 through December 2000 were reviewed retrospectively. RESULTS: A ventricular septal defect was present in 186 (30%) patients. Coronary anatomy was type A in 69% of the patients, and aortic arch pathology was present in 20% of patients with ventricular septal defect. Rashkind septostomy was performed in 75% of the patients, and 69% received prostaglandin. There were 37 hospital deaths (operative mortality, 6%), 13 (3%) for patients with an intact ventricular septum and 24 (13%) for those with a ventricular septal defect (P < .001). In 36% delayed sternal closure was performed, 8% required peritoneal dialysis, and 2% required mechanical circulatory support. Median ventilation time was 58 hours, and intensive care and hospital stay were 6 and 14 days, respectively. Although of various preoperative risk factors the presence of a ventricular septal defect, arch pathology, and coronary anomalies were univariate predictors of operative mortality, only the presence of a ventricular septal defect approached statistical significance (P = .06) on multivariable analysis. Of various operative parameters, aortic crossclamp time and delayed sternal closure were also univariate predictors; however, only the latter was an independent statistically significant predictor of death. CONCLUSIONS: Results of the procedure in European centers are compatible with those in the literature. The presence of a ventricular septal defect is the clinically most important preoperative risk factor for operative death, approaching statistical significance on multivariable analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The vitamin D(3) and nicotine (VDN) model is one of isolated systolic hypertension (ISH) in which arterial calcification raises arterial stiffness and vascular impedance. The effects of VDN treatment on arterial and cardiac hemodynamics have been investigated; however, a complete analysis of ventricular-arterial interaction is lacking. Wistar rats were treated with VDN (VDN group, n = 9), and a control group (n = 10) was included without the VDN. At week 8, invasive indexes of cardiac function were obtained using a conductance catheter. Simultaneously, aortic pressure and flow were measured to derive vascular impedance and characterize ventricular-vascular interaction. VDN caused significant increases in systolic (138 +/- 6 vs. 116 +/- 13 mmHg, P < 0.01) and pulse (42 +/- 10 vs. 26 +/- 4 mmHg, P < 0.01) pressures with respect to control. Total arterial compliance decreased (0.12 +/- 0.08 vs. 0.21 +/- 0.04 ml/mmHg in control, P < 0.05), and pulse wave velocity increased significantly (8.8 +/- 2.5 vs. 5.1 +/- 2.0 m/s in control, P < 0.05). The arterial elastance and end-systolic elastance rose significantly in the VDN group (P < 0.05). Wave reflection was augmented in the VDN group, as reflected by the increase in the wave reflection coefficient (0.63 +/- 0.06 vs. 0.52 +/- 0.05 in control, P < 0.05) and the amplitude of the reflected pressure wave (13.3 +/- 3.1 vs. 8.4 +/- 1.0 mmHg in control, P < 0.05). We studied ventricular-arterial coupling in a VDN-induced rat model of reduced arterial compliance. The VDN treatment led to development of ISH and provoked alterations in cardiac function, arterial impedance, arterial function, and ventricular-arterial interaction, which in many aspects are similar to effects of an aged and stiffened arterial tree.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To prospectively determine the accuracy of 1.5 Tesla (T) and 3 T magnetic resonance angiography (MRA) versus digital subtraction angiography (DSA) in the depiction of infrageniculate arteries in patients with symptomatic peripheral arterial disease. PATIENTS AND METHODS: A prospective 1.5 T, 3 T MRA, and DSA comparison was used to evaluate 360 vessel segments in 10 patients (15 limbs) with chronic symptomatic peripheral arterial disease. Selective DSA was performed within 30 days before both MRAs. The accuracy of 1.5 T and 3 T MRA was compared with DSA as the standard of reference by consensus agreement of 2 experienced readers. Signal-to-noise ratios (SNR) and signal-difference-to-noise ratios (SDNRs) were quantified. RESULTS: No significant difference in overall image quality, sufficiency for diagnosis, depiction of arterial anatomy, motion artifacts, and venous overlap was found comparing 1.5 T with 3 T MRA (P > 0.05 by Wilcoxon signed rank and as by Cohen k test). Overall sensitivity of 1.5 and 3 T MRA for detection of significant arterial stenosis was 79% and 82%, and specificity was 87% and 87% for both modalities, respectively. Interobserver agreement was excellent k > 0.8, P < 0.05) for 1.5 T as well as for 3 T MRA. SNR and SDNR were significantly increased using the 3 T system (average increase: 36.5%, P < 0.032 by t test, and 38.5%, P < 0.037 respectively). CONCLUSIONS: Despite marked improvement of SDNR, 3 T MRA does not yet provide a significantly higher accuracy in diagnostic imaging of atherosclerotic lesions below the knee joint as compared with 1.5 T MRA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To review the accuracy of electrocardiography in screening for left ventricular hypertrophy in patients with hypertension. DESIGN: Systematic review of studies of test accuracy of six electrocardiographic indexes: the Sokolow-Lyon index, Cornell voltage index, Cornell product index, Gubner index, and Romhilt-Estes scores with thresholds for a positive test of > or =4 points or > or =5 points. DATA SOURCES: Electronic databases ((Pre-)Medline, Embase), reference lists of relevant studies and previous reviews, and experts. STUDY SELECTION: Two reviewers scrutinised abstracts and examined potentially eligible studies. Studies comparing the electrocardiographic index with echocardiography in hypertensive patients and reporting sufficient data were included. DATA EXTRACTION: Data on study populations, echocardiographic criteria, and methodological quality of studies were extracted. DATA SYNTHESIS: Negative likelihood ratios, which indicate to what extent the posterior odds of left ventricular hypertrophy is reduced by a negative test, were calculated. RESULTS: 21 studies and data on 5608 patients were analysed. The median prevalence of left ventricular hypertrophy was 33% (interquartile range 23-41%) in primary care settings (10 studies) and 65% (37-81%) in secondary care settings (11 studies). The median negative likelihood ratio was similar across electrocardiographic indexes, ranging from 0.85 (range 0.34-1.03) for the Romhilt-Estes score (with threshold > or =4 points) to 0.91 (0.70-1.01) for the Gubner index. Using the Romhilt-Estes score in primary care, a negative electrocardiogram result would reduce the typical pre-test probability from 33% to 31%. In secondary care the typical pre-test probability of 65% would be reduced to 63%. CONCLUSION: Electrocardiographic criteria should not be used to rule out left ventricular hypertrophy in patients with hypertension.