161 resultados para Aneurysm dissecting


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this study was to establish and validate a three-dimensional imaging protocol for the assessment of Computed Tomography (CT) scans of abdominal aortic aneurysms in UK EVAR trials patients. Quality control and repeatability of anatomical measurements is important for the validity of any core laboratory. METHODS: Three different observers performed anatomical measurements on 50 preoperative CT scans of aortic aneurysms using the Vitrea 2 three-dimensional post-imaging software in a core laboratory setting. We assessed the accuracy of intra and inter observer repeatability of measurements, the time required for collection of measurements, 3 different levels of automation and 3 different automated criteria for measurement of neck length. RESULTS: None of the automated neck length measurements demonstrated sufficient accuracy and it was necessary to perform checking of the important automated landmarks. Good intra and limited inter observer agreement were achieved with three-dimensional assessment. Complete assessment of the aneurysm and iliacs took an average (SD) of 17.2 (4.1) minutes. CONCLUSIONS: Aortic aneurysm anatomy can be assessed reliably and quickly using three-dimensional assessment but for scans of limited quality, manual checking of important landmarks remains necessary. Using a set protocol, agreement between observers is satisfactory but not as good as within observers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The standard technique of two-dimensional intra-arterial digital subtraction angiography (2D-DSA) for the imaging of experimental rabbit aneurysms is invasive and has considerable surgical risks. Therefore, minimally invasive techniques ideally providing three-dimensional imaging for intervention planning and follow-up are needed. This study evaluates the feasibility and quality of three-dimensional 3-T magnetic resonance angiography (3D-3T-MRA) and compares 3D-3T-MRA with 2D-DSA in experimental aneurysms in the rabbit. METHOD: Three microsurgically created aneurysms in three rabbits were evaluated using 2D-DSA and 3D-3T-MRA. Imaging of the aneurysms was performed 2 weeks after creation using 2D-DSA and contrast-enhanced (CE) MRA. Measurements included aneurysm dome (length and width) and aneurysm neck. Aneurysm volumes were determined using CE-MRA. RESULTS: The measurements of the aneurysms' dimensions and the evaluation of vicinity vessels with both techniques showed a good correlation. The mean aneurysm length, aneurysm width and neck width measured with DSA (6.9, 4.1 and 2.8 mm, respectively) correlated with the measurements performed in 3D-3T-MRA (6.9, 4 and 2.5 mm, respectively). The mean aneurysm volumes measured with CE-MRA was 46.7 mm(3). CONCLUSION: 3D-3T CE-MRA is feasible and less invasive and is a safer imaging alternative to DSA for experimental aneurysm. Additionally, aneurysm technique this precise offers the possibility of repetitive 3D aneurysm volumetry for long-term follow-up studies after endovascular aneurysm occlusion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abdominal aortic aneurysms (AAA) confer a substantial healthcare burden in the Western world. Surgical or endovascular therapy is indicated in patients with a maximum diameter exceeding 5.5 cm. Patients with smaller AAA must undergo a specific ultrasound surveillance program aimed at avoiding exposure to an increased risk of rupture once their AAA exceeds the threshold for active treatment. Based on improved understanding of the pathophysiology of AAA, recent years provided initial insight into potential medical treatment options. The presence of AAA is currently regarded a coronary artery disease risk equivalent. ACE inhibitors, statins and JNK-inhibitors were shown to have the potential to slow down progression. Since cigarette smoking is the main risk factor for both the development and progression of AAA, smoking cessation remains a key goal. Further prospective studies will assess the clinical efficacy of various promising drug treatment approaches aimed at slowing disease progression of small AAA and after endovascular therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To retrospectively evaluate the safety and effectiveness of the use of bivalirudin, a direct thrombin antagonist, compared with unfractionated heparin in endovascular aneurysm repair (EVAR). MATERIALS AND METHODS: Between March 1994 and September 2007, 740 consecutive patients (mean age, 75.7 y +/- 7.7; 69 women) underwent elective EVAR for infrarenal abdominal aortic aneurysm. Bivalirudin was used in 98 of these 740 (13.2%) and unfractioned heparin was used in the other 642 (86.8%). Complications were classified according to the Society of Vascular Surgery/International Society for Cardiovascular Surgery criteria. Major bleeding was defined as clinically overt blood loss resulting in a decrease of hemoglobin of more than 3 g/dL, any decrease in hemoglobin of more than 4 g/dL, transfusion of 2 U or more of red blood cells, or intracranial or retroperitoneal hemorrhage. RESULTS: Grade 1 major complications were observed in 161 of 642 patients (25.2%) in the heparin group and 12 of 98 patients (12.2%) in the bivalirudin group (P = .0046), whereas the incidences of grade 3 major complications were not significantly different between groups (P = .57). The rate of total complications was higher in the heparin group than in the bivalirudin group (247 of 642 [38.5%] vs 21 of 98 [21.4%]; P = .001). Major bleeding occurred in 10 of 98 patients (10.2%) receiving bivalirudin and in 91 of 642 patients (14.2%) receiving heparin (P = .34). One of 21 major complications (4.76%) in the bivalirudin group and 12 of 247 major complications (4.86%) in the heparin group were attributable to thrombosis (P = 1.0). CONCLUSIONS: Bivalirudin is a safe and feasible alternative to unfractionated heparin in patients undergoing EVAR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To analyze the detection of endoleaks with low-tube-voltage computed tomographic (CT) angiography.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pulmonary artery aneurysm in adults is a rare diagnosis. Most cases described in the literature are either associated with congenital heart disease or pulmonal arterial hypertension, respectively, or are not true aneurysms but rather pseudoaneurysms, which are usually iatrogenic. We present the case of a 68-year old female patient with the incidental finding of a true aneurysm of the right peripheral pulmonary artery with a maximum diameter of 4 cm. With increasing aneurysm diameter over time, the decision for a surgical resection was made. Complete resection of the aneurysm including lower lobe resection was performed. Histopathological examination showed necrotizing giant cell arteritis as the underlying cause. The postoperative course was uneventful and no signs of further disease activity were detected. To our knowledge, this is the first reported case of a pulmonary artery aneurysm caused by giant cell arteritis, whereas it should be noted that the distinction between Takayasu arteritis and giant cell arteritis is not clearly defined. Considering the high mortality associated with aneurysm rupture, surveillance is advocated for small aneurysms, whereas for larger aneurysms and those showing signs of progression in size despite medical therapy or even dissection, surgical intervention should be considered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Transcatheter aortic valve replacement (TAVR) as well as thoracic and abdominal endovascular aortic repair (TEVAR and EVAR) rely on accurate pre- and postprocedural imaging. This review article discusses the application of imaging, including preprocedural assessment and measurements as well as postprocedural imaging of complications. Furthermore, the exciting perspective of computational fluid dynamics (CFD) based on cross-sectional imaging is presented. TAVR is a minimally invasive alternative for treatment of aortic valve stenosis in patients with high age and multiple comorbidities who cannot undergo traditional open surgical repair. Given the lack of direct visualization during the procedure, pre- and peri-procedural imaging forms an essential part of the intervention. Computed tomography angiography (CTA) is the imaging modality of choice for preprocedural planning. Routine postprocedural follow-up is performed by echocardiography to confirm treatment success and detect complications. EVAR and TEVAR are minimally invasive alternatives to open surgical repair of aortic pathologies. CTA constitutes the preferred imaging modality for both preoperative planning and postoperative follow-up including detection of endoleaks. Magnetic resonance imaging is an excellent alternative to CT for postoperative follow-up, and is especially beneficial for younger patients given the lack of radiation. Ultrasound is applied in screening and postoperative follow-up of abdominal aortic aneurysms, but cross-sectional imaging is required once abnormalities are detected. Contrast-enhanced ultrasound may be as sensitive as CTA in detecting endoleaks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a case of a ruptured abdominal aortic aneurysm (AAA) with ambiguous accessory findings on post-mortem computed-tomography (PMCT), post-mortem magnetic resonance (PMMR) imaging, and PMCT-angiography (PMCTA) suggestive of thoracic aortic dissection. The diagnosis of ruptured AAA was confirmed by autopsy; however, there was no aortic dissection. The imaging findings that mimicked the presence of aortic dissection might have been an atypical presentation of post-mortem clotting or sedimentation. This case is an ideal example to illustrate benefits, limitations, and challenges of post-mortem cross-sectional imaging. It serves as a reminder that both, training as well as correlation of imaging findings with autopsy are fundamental to improve our understanding of radiologic findings on post-mortem cross-sectional imaging.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND The population-based effectiveness of thoracic endovascular aortic repair (TEVAR) versus open surgery for descending thoracic aortic aneurysm remains in doubt. METHODS Patients aged over 50 years, without a history of aortic dissection, undergoing repair of a thoracic aortic aneurysm between 2006 and 2011 were assessed using mortality-linked individual patient data from Hospital Episode Statistics (England). The principal outcomes were 30-day operative mortality, long-term survival (5 years) and aortic-related reinterventions. TEVAR and open repair were compared using crude and multivariable models that adjusted for age and sex. RESULTS Overall, 759 patients underwent thoracic aortic aneurysm repair, mainly for intact aneurysms (618, 81·4 per cent). Median ages of TEVAR and open cohorts were 73 and 71 years respectively (P < 0·001), with more men undergoing TEVAR (P = 0·004). For intact aneurysms, the operative mortality rate was similar for TEVAR and open repair (6·5 versus 7·6 per cent; odds ratio 0·79, 95 per cent confidence interval (c.i.) 0·41 to 1·49), but the 5-year survival rate was significantly worse after TEVAR (54·2 versus 65·6 per cent; adjusted hazard ratio 1·45, 95 per cent c.i. 1·08 to 1·94). After 5 years, aortic-related mortality was similar in the two groups, but cardiopulmonary mortality was higher after TEVAR. TEVAR was associated with more aortic-related reinterventions (23·1 versus 14·3 per cent; adjusted HR 1·70, 95 per cent c.i. 1·11 to 2·60). There were 141 procedures for ruptured thoracic aneurysm (97 TEVAR, 44 open), with TEVAR showing no significant advantage in terms of operative mortality. CONCLUSION In England, operative mortality for degenerative descending thoracic aneurysm was similar after either TEVAR or open repair. Patients who had TEVAR appeared to have a higher reintervention rate and worse long-term survival, possibly owing to cardiopulmonary morbidity and other selection bias.