95 resultados para visual analog scale
Resumo:
PURPOSE: Family needs and expectations are often unmet in the intensive care unit (ICU), leading to dissatisfaction. This study assesses cross-cultural adaptability of an instrument evaluating family satisfaction in the ICU. MATERIALS AND METHODS: A Canadian instrument on family satisfaction was adapted for German language and central European culture and then validated for feasibility, validity, internal consistency, reliability, and sensitivity. RESULTS: Content validity of a preliminary translated version was assessed by staff, patients, and next of kin. After adaptation, content and comprehensibility were considered good. The adapted translation was then distributed to 160 family members. The return rate was 71.8%, and 94.4% of questions in returned forms were clearly answered. In comparison with a Visual Analogue Scale, construct validity was good for overall satisfaction with care (Spearman rho = 0.60) and overall satisfaction with decision making (rho = 0.65). Cronbach alpha was .95 for satisfaction with care and .87 for decision-making. Only minor differences on repeated measurements were found for interrater and intrarater reliability. There was no floor or ceiling effect. CONCLUSIONS: A cross-cultural adaptation of a questionnaire on family satisfaction in the ICU can be feasible, valid, internally consistent, reliable, and sensitive.
Resumo:
The objective of this study was to determine the effect of wearing a mouthguard on maximal exercise capacity and cardiopulmonary parameters at peak workload, and to assess the athletes' attitudes toward wearing a mouthguard. Thirteen volunteer male athletes (18 to 27 years old) were interviewed before and after delivery of a custom-made laminated mouthguard. A visual analogue scale (VAS, 0 - 100 mm) was used for judgment of interference with breathing, speaking, concentration and athletic performance. In addition, the athletes were subjected to a cardiorespiratory examination on a cycle ergometer with and without mouthguards. Subjectively, the athletes rated the mean interference with performance to be 37 mm VAS at the beginning of the study. Mean scores of impairment decreased to 23 mm VAS (p = 0.081) after wearing the mouthguard for four weeks, and further improved to 12 mm VAS (p < 0.001) after the test on the cycle ergometer. Objectively, the maximum workload during spiroergometry was even slightly elevated during exercise with the mouthguard (330.2 W) compared to exercise without the mouthguard (314.5 W). Peak minute ventilation and oxygen uptake were not different during exercise with and without the mouthguard. The present study demonstrated that a custom-made mouthguard does not significantly affect or reduce maximum exercise performance of athletes.
Resumo:
WHAT IS ALREADY KNOWN ABOUT THIS SUBJECT: * Among children, medication palatability is crucial for adherence to therapeutic regimen. * Several studies have measured the palatability of antimicrobial suspensions in paediatric patients by means of a visual analogue scale palatability score. WHAT THIS STUDY ADDS: * This is the first analysis comparing the taste and smell acceptability of angiotensin II receptor blockers among paediatric patients with kidney disease. * From the perspective of the child with kidney disease, the taste of pulverized candesartan is significantly superior to that of pulverized irbesartan, losartan, telmisartan or valsartan. AIM: Angiotensin II receptor blockers are widely prescribed in kidney disease. Among children, medication palatability is crucial for adherence. METHODS: Taste and smell acceptability of five angiotensin II receptor blockers were compared among 21 nephropathic children using a visual analogue scale palatability score. RESULTS: The score assigned to pulverized tablets of candesartan cilexetil was significantly higher than that assigned to pulverized tablets of irbesartan, losartan, telmisartan and valsartan. CONCLUSIONS: From the perspective of the nephropathic child, the taste of pulverized candesartan cilexetil is superior to that of irbesartan, losartan, telmisartan or valsartan.
Resumo:
The muscle has a wide range of possibilities to adapt its phenotype. Repetitive submaximal concentric exercise (i.e., shortening contractions) mainly leads to adaptations of muscle oxidative metabolism and endurance while eccentric exercise (i.e., lengthening contractions) results in muscle growth and gain of muscle strength. Modified gene expression is believed to mediate these exercise-specific muscle adjustments. In the present study, early alterations of the gene expression signature were monitored by a muscle-specific microarray. Transcript profiling was performed on muscle biopsies of vastus lateralis obtained from six male subjects before and in a 24-h time course after a single bout of mild eccentric ergometer exercise. The eccentric exercise consisted of 15 min of eccentric cycling at 50% of the individual maximal concentric power output leading to muscle soreness (5.9 on a 0-10 visual analogue scale) and limited muscle damage (1.7-fold elevated creatine kinase activity). Muscle impairment was highlighted by a transient reduction in jumping height after the eccentric exercise. On the gene expression level, we observed a general early downregulation of detected transcripts, followed by a slow recovery close to the control values within the first 24 h post exercise. Only very few regulatory factors were increased. This expression signature is different from the signature of a previously published metabolic response after an intensive endurance-type concentric exercise as well as after maximal eccentric exercise. This is the first description of the time course of changes in gene expression as a consequence of a mild eccentric stimulus.
Resumo:
The aim was to investigate the efficacy of a combination of low-dose remifentanil (REMI) and ketamine (KET) compared to the single drugs and placebo (P) on whiplash associated pain (WAD) in a double-blind, randomized, placebo-controlled, cross-over study. Twenty patients with chronic (>1 year) WAD were included. Four different drug combinations were tested in four sessions: placebo/placebo (P/P), placebo/remifentanil (P/REMI), ketamine/placebo (KET/P) and ketamine/remifentanil (KET/REMI). Target concentrations were 1 and 2ng/ml (stepwise) for remifentanil and 100ng/ml for ketamine. Habitual pain intensity was assessed on a visual analogue scale (VAS). Experimental pain was assessed with electrical stimulation (single and repeated) of tibialis anterior (TA) muscle, pressure pain algometry applied over infraspinatus (IS) and TA muscles and VAS scores after intramuscular hypertonic saline infusion in TA. KET/REMI significantly reduced habitual pain. KET/REMI infused at low REMI target concentration (1ng/ml) significantly elevated electrical intramuscular pain thresholds (single and repeated). Pain thresholds to electrical stimulation were similarly increased by both P/REMI and KET/REMI at 2ng/ml target concentration. Pressure pain thresholds were increased by both KET/REMI and P/REMI. VAS-scores after intramuscular saline were also similarly decreased by both REMI combinations. Seven out of 20 subjects were non-responders (<50% pain relief). No correlation was found between effects on spontaneous pain and experimental pain. KET/REMI showed an analgesic effect on habitual pain. Experimental pain was attenuated by both combinations containing the opioid, however, KET seemed to enhance the effect of REMI on electrical pain thresholds when a low REMI target concentration was used.
Resumo:
Different types of titanium-alloys instead of CoCr-alloys have been tested as material for the framework of removable partial dentures (RPD). Adequate casting and processing techniques have been developed which enable to fabricate frameworks of complex designs and the problem limits porosity. This opened new possibilities for the use of titanium-alloys with improved properties (E-module). The aim of this study was to summarise the use of titanium in removable prosthodontics and to evaluate prospectively the use of the Ti6A17Nb-alloy for RPDs in a small group of patients. Two identically designed RPDs from CoCr-alloy (remanium GM 800+) and Ti6A17Nb-alloy (girotan L) were produced for ten patients. They had to wear each RPD during six months, first the CoCr-RPD and then the Ti6A17Nb-RPD. A questionnaire (visual analogue scale = VAS) was completed by the patients after one, three and six months of function for each RPD. Prosthetic complications and service needed were recorded. After the end of the entire observation period of twelve months, the patients remained with the Ti6A17Nb-RPD and answered the questionnaire after another six months. All parameters regarding the design of the RPDs were positively estimated by the dentist. Minimal, not significant differences were noted by the patients concerning comfort, stability and retention (VAS). Clinically, no differences in technical aspects or regarding biological complications were observed after six-months periods. The Ti6A17Nb-alloy (girotan L) for the framework of RPDs was judged by patients and professionals to be equivalent to RPDs made from CoCr-alloy. No differences in material aspects could objectively be observed. The Ti6A17Nb-alloy can be beneficial for patients with allergies or incompatibility with one or several components of the CoCr-alloy.
Resumo:
BACKGROUND: There is evidence for the superiority of two-implant overdentures over complete dentures in the mandible. Various anchorage devices were used to provide stability to overdentures. The aim of the present study was to compare two designs of a rigid bar connecting two mandibular implants. MATERIALS AND METHODS: Completely edentulous patients received a new denture in the maxilla and an implant-supported overdenture in the mandible. They were randomly allocated to two groups (A or B) with regard to the bar design. A standard U-shaped bar (Dolder bar) was used connecting the two implants in a straight line. For comparison, precision attachments were soldered distal to the bar copings. Group A started the study with the standard bar (S-bar), while group B started with the attachment-bar (A-bar). After 3 months, they had to answer a questionnaire (visual analogue scale [VAS]); then the bar design was changed in both groups. After a period of another 3 months, the patients had to answer the same questions; then they had the choice to keep their preferred bar. Now the study period was extended to another year of observation, and the patients answered again the same questionnaire. In vivo force measurements were carried out with both bar types at the end of the test periods. The prosthetic maintenance service carried out during the 6-month period was recorded for both bar types in both groups. Statistical analysis as performed with the SPSS statistical package (SPSS Inc., Chicago, IL, USA). RESULTS: Satisfaction was high in both groups. Group B, who had entered the study with the attachment bar, gave slightly better ratings to this type for four items, while in group A, no differences were found. At the end of the 6-month comparison period, all but one patient wished to continue to wear the attachment bar. Prosthetic service was equal in groups A and B, but the total number of interventions is significantly higher in the attachment bar. Force patterns of maximum biting were similar in both bar designs, but exhibited significantly higher axial forces in the attachment bar. CONCLUSIONS: Both bar designs provide good retention and functional comfort. High stability appears to be an important factor for the patients' satisfaction and oral comfort. Rigid retention results in a higher force impact and appears to evoke the need for the retightening of occlusal screws, resulting in more maintenance service.
Resumo:
INTRODUCTION: Little explanation is given to patients with temporomandibular disorders and muscles dysfunction on the mechanism and the expected results of conservative treatment. The purpose of this prospective study was to evaluate the efficacy of specific physical therapy prescribed after this explanation was given and also after using a flat occlusal splint adapted only if muscle pain remained after physical therapy. MATERIAL AND METHOD: Twenty-seven patients with temporomandibular joint dysfunction of muscular origin were evaluated after a mean of six sessions of specialized physical therapy with professionals. Patients were treated by oral and facial massages and were trained for self-reeducation. They were also trained for a specific exercise named the "propulsive/opening maneuver". Every patient was questioned on the subjective evolution of pain and the current maximal pain was evaluated with the Visual Analogical Scale (VAS). Clinical evaluation focused on tenderness of masticator muscles and also assessed the changes in the amplitude of mouth opening. RESULTS: Ninety-three percent of the patients treated by specific physical therapy had a significant reduction of their maximal pain feeling (p<0.05). The recovery of an optimal mouth opening without deviation was also improved as was the protrusion. For 33% of the patients a flat nighttime occlusal splint was necessary as a complementary treatment. Twenty-two percent of the patients decided to change their treatment for alternative therapies (osteopathy, acupuncture, etc.). Fifty percent of the patients were convinced of the efficacy of the prescribed treatment. DISCUSSION: Patients who undertake the specific physical therapy and who regularly practice self-physical therapy succeed in relaxing their masticator muscles and in decreasing the level of pain. Explanations given by the doctor concerning the etiology of pain, during temporomandibular joint dysfunction of muscular origin, and the purpose of specific physical therapy increase the capacity of self-relaxation. A flat occlusal splint is indicated for patients who grind their teeth and for those whose pain resists to physical therapy.
Resumo:
PURPOSE: To determine whether the treatment of hypersensitive teeth with gaseous ozone (Healozone, KaVo 1600 ppm) for 60 seconds reduces pain immediately after treatment and in the longer term. METHODS: In three private practices in Switzerland, 31 subjects suffering from hypersensitive teeth were treated with gaseous ozone over a period of 54 weeks (one test and one control tooth in each subject). A cross-over design was chosen. The pain level was measured with a Visual Analogue Scale before and after the treatment. RESULTS: The subjects' pain level was reduced by 55% +/- 5.5% immediately after the ozone treatment. Over time, the pain level decreased significantly in all groups: The pain level in the test teeth was significantly reduced in Weeks 0-22 (treatment group, P < 0.001) compared to the pain level before treatment. The pain level in the control group was also reduced significantly over time in Weeks 0-22 (no-treatment, P = 0.025) and in Weeks 22-54 (treatment group, P = 0.0065). Comparing test and control teeth over time, there was no statistically significant difference in pain reduction (P = 0.58).
Resumo:
BACKGROUND: In Switzerland approximately 8% of infants are born prematurely. Some of them undergo mechanical ventilation including endotracheal suctioning (ETS). ETS is one of the most frequently performed interventions and is linked to stress and pain, but its treatment is controversial. In Switzerland there is a lack of standardisation in pain relief for ETS. AIMS: To test the hypothesis that an intermittent dose of morphine reduces pain during ETS and that subsequent multisensorial stimulation (MSS), as a non pharmacological comforting intervention, helps infants to recover from experienced pain. METHOD: A randomized placebo controlled trial in two tertiary neonatal intensive care units (NICU) with a sample of 30 mechanically ventilated preterm infants was conducted. Pain was measured by three pain assessment tools (Bernese Pain Scale for Neonates, Premature Infant Pain Profile and Visual Analogue Scale) RESULTS: Morphine did not lead to any pain relief from ETS as measured by three pain scales. Nor did the comforting intervention of MSS show any effect. Repeated-measure analysis of variance for the within and between groups comparison showed no statistical significance. CONCLUSIONS: The administration of morphine for pain relief in ventilated preterm neonates during ETS remains questionable and the use of MSS as a comforting intervention after painful stimulus cannot be recommended. The validity testing of the instruments for this patient population should undergo a systematic validation trajectory. Future research should focus on options among non pharmacological interventions for relieving pain during ETS.
Resumo:
BACKGROUND: Pain associated with routine procedures in NICUs is often inadequately managed. Barriers to more appropriate pain management are nurses' and physicians' knowledge and the challenges of collaborative decision-making. Few studies describe the differing perceptions of procedural pain intensity among nurses and physicians in NICUs which could complicate common decision-making. This study set out to explore the factors influencing pain intensity assessment and to gain insight into a possible pain intensity classification of routine procedures in the NICU. METHOD: A survey was conducted among 431 neonatal health care professionals from 4 tertiary level NICUs. Each routine procedure was assessed on a 10-point visual analogue scale (VAS) assuming absence of analgesia. RESULTS: Multiple ANCOVA models showed that nurses rated 19 of the 27 procedures as significantly more painful than did physicians (p<0.05). We found no differences in pain assessment based on professional experience, gender or age. Of the 27 procedures listed, 70% were rated as painful and 44% were judged very painful. Ranking and classification of the pain intensity of routine procedures were drawn up. The general ranking of the median across all procedures shows that "insertion of a thoracic drain" is assessed as the most painful procedure. CONCLUSIONS: The majority of routine procedures in an NICU are considered to be painful. Nurses generally rate procedures as more painful than do physicians. This difference in assessment deserves exploration in regard to its impact on collaborative decision-making in neonate pain management.
Resumo:
AIM: To explore the variability in pain response in preterm infants across time who received sucrose during routine heel stick. METHOD: Single group, exploratory repeated measures design. SETTING: Two tertiary level neonatal intensive care units (NICU) in Switzerland. SUBJECTS: Nine preterm infants born between 28 2/7 and 31 4/7 weeks of gestation during their first 14 days of life. MEASUREMENTS: Pain was assessed by the Bernese Pain Scale for Neonates (BPSN), the Premature Infant Pain Profile (PIPP) and the Visual Analogue Scale (VAS). Salivary cortisol was analysed. RESULTS: 72-94% of the variability was within-subject variability, indicating inconsistency of pain responses across the 5 heel sticks. Interrater agreement was highest during heel sticks 1-3 and decreased during heel stick 4 and 5, indicating a possible alteration of pain patterns. No significant differences in the amount of cortisol could be detected before and after the heel sticks (p = 0.55), indicating no stress-induced peak after the painful intervention. However, a general gradual decrease of cortisol levels across time could be detected. CONCLUSION: A high variability in pain response among preterm neonates across time could be described. Consistency of cortisol levels before and after the heel sticks could indicate the effectiveness of sucrose across time.
Resumo:
BACKGROUND: Low back pain (LBP) is by far the most prevalent and costly musculoskeletal problem in our society today. Following the recommendations of the Multinational Musculoskeletal Inception Cohort Study (MMICS) Statement, our study aims to define outcome assessment tools for patients with acute LBP and the time point at which chronic LBP becomes manifest and to identify patient characteristics which increase the risk of chronicity. METHODS: Patients with acute LBP will be recruited from clinics of general practitioners (GPs) in New Zealand (NZ) and Switzerland (CH). They will be assessed by postal survey at baseline and at 3, 6, 12 weeks and 6 months follow-up. Primary outcome will be disability as measured by the Oswestry Disability Index (ODI); key secondary endpoints will be general health as measured by the acute SF-12 and pain as measured on the Visual Analogue Scale (VAS). A subgroup analysis of different assessment instruments and baseline characteristics will be performed using multiple linear regression models. This study aims to examine: 1. Which biomedical, psychological, social, and occupational outcome assessment tools are identifiers for the transition from acute to chronic LBP and at which time point this transition becomes manifest. 2. Which psychosocial and occupational baseline characteristics like work status and period of work absenteeism influence the course from acute to chronic LBP. 3. Differences in outcome assessment tools and baseline characteristics of patients in NZ compared with CH. DISCUSSION: This study will develop a screening tool for patients with acute LBP to be used in GP clinics to access the risk of developing chronic LBP. In addition, biomedical, psychological, social, and occupational patient characteristics which influence the course from acute to chronic LBP will be identified. Furthermore, an appropriate time point for follow-ups will be given to detect this transition. The generalizability of our findings will be enhanced by the international perspective of this study. TRIAL REGISTRATION: [Clinical Trial Registration Number, ACTRN12608000520336].
Resumo:
OBJECTIVE: To evaluate quality of life and patients' satisfaction in transsexual patients (TS) after sex reassignment operation compared with healthy controls. DESIGN: A case-control study. SETTING: A tertiary referral center. PATIENT(S): Patients after sex reassignment operation were compared with a similar group of healthy controls in respect to quality of life and general satisfaction. INTERVENTION(S): For quality of life we used the King's Health Questionnaire, which was distributed to the patients and to the control group. Visual analogue scale was used for the determination of satisfaction. MAIN OUTCOME MEASURE(S): Main outcome measures were quality of life and satisfaction. RESULT(S): Fifty-five transsexuals participated in this study. Fifty-two were male-to-female and 3 female-to-male. Quality of life as determined by the King's Health Questionnaire was significantly lower in general health, personal, physical and role limitations. Patients' satisfaction was significantly lower compared with controls. Emotions, sleep, and incontinence impact as well as symptom severity is similar to controls. Overall satisfaction was statistically significant lower in TS compared with controls. CONCLUSION(S): Fifteen years after sex reassignment operation quality of life is lower in the domains general health, role limitation, physical limitation, and personal limitation.
Resumo:
INTRODUCTION: Impact on sexual function has received little attention in the medical literature for a long time. Because of the site of insertion of permanent tension free vaginal tape (TVT) the G spot might be affected or the tape might interfere with arousal and sensory stimulation. Recent studies have reported varying degrees of sexual impairment after TVT insertion ranging from 0% to 15% including dyspareunia. AIM: The aim of this study was to evaluate sexual function before and after suburethral sling removal due to postoperative female de novo dyspareunia. As a secondary outcome, general patients' satisfaction with their overall continence situation was assessed. PATIENTS AND METHODS: Between December 2005 and December 2007, we included 18 female patients who complained of de novo dyspareunia after suburethral sling insertion for urinary stress incontinence. All patients filled in an FSFI questionnaire prior to sling removal and at 3 months postoperatively. Additionally, all women were asked to estimate their general satisfaction regarding their continence situation using a Visual Analogue Scale (VAS) from 0 to 10, with 0 being the least satisfying situation and 10 being the most satisfying situation. All patients underwent gynaecological examination including ICS-pelvic organ prolapse staging (ICS-POP score). RESULTS: Of the 18 slings, ten were transobturator tapes (6 x TVT-O, 2 x Monarch, 2 x unknown) and eight were retropubic tapes (7 x TVT, 1 x SPARC). Desire, arousal, lubrication, satisfaction, and pain improved statistically significant. Orgasm scores were low with median scoring of 1.5 scores before and 1.0 scores after sling removal, and they did not change significantly after sling removal. The satisfaction rate deteriorated from a median of 7 (95% confidence interval [CI] 6.3-7.7) to a median of 4 (95% CI 3.7-5.1; p=0.99) but not statistically significant. CONCLUSIONS: Sexual function in patients with de novo dyspareunia is likely to improve after sling removal but not in all domains. Bladder function may deteriorate.