73 resultados para ultra-high-vacuum magneto-optical trap


Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIMS In this work, we provide novel insight into the morphology of dissecting abdominal aortic aneurysms in angiotensin II-infused mice. We demonstrate why they exhibit a large variation in shape and, unlike their human counterparts, are located suprarenally rather than infrarenally. METHODS AND RESULTS We combined synchrotron-based, ultra-high resolution ex vivo imaging (phase contrast X-Ray tomographic microscopy) with in vivo imaging (high-frequency ultrasound and contrast-enhanced micro-CT) and image-guided histology. In all mice, we observed a tear in the tunica media of the abdominal aorta near the ostium of the celiac artery. Independently we found that, unlike the gradual luminal expansion typical for human aneurysms, the outer diameter increase of angiotensin II-induced dissecting aneurysms in mice was related to one or several intramural haematomas. These were caused by ruptures of the tunica media near the ostium of small suprarenal side branches, which had never been detected by the established small animal imaging techniques. The tear near the celiac artery led to apparent luminal dilatation, while the intramural haematoma led to a dissection of the tunica adventitia on the left suprarenal side of the aorta. The number of ruptured branches was higher in those aneurysms that extended into the thoracic aorta, which explained the observed variability in aneurysm shape. CONCLUSION Our results are the first to describe apparent luminal dilatation, suprarenal branch ruptures, and intramural haematoma formation in dissecting abdominal aortic aneurysms in mice. Moreover, we validate and demonstrate the vast potential of phase contrast X-ray tomographic microscopy in cardiovascular small animal applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Plants respond to herbivory by reprogramming their metabolism. Most research in this context has focused on locally induced compounds that function as toxins or feeding deterrents. We developed an ultra-high-pressure liquid chromatography time-of-flight mass spectrometry (UHPLC-TOF-MS)-based metabolomics approach to evaluate local and systemic herbivore-induced changes in maize leaves, sap, roots and root exudates without any prior assumptions about their function. Thirty-two differentially regulated compounds were identified from Spodoptera littoralis-infested maize seedlings and isolated for structure assignment by microflow nuclear magnetic resonance (CapNMR). Nine compounds were quantified by a high throughput direct nano-infusion tandem mass spectrometry/mass spectrometry (MS/MS) method. Leaf infestation led to a marked local increase of 1,3-benzoxazin-4-ones, phospholipids, N-hydroxycinnamoyltyramines, azealic acid and tryptophan. Only few changes were found in the root metabolome, but 1,3-benzoxazin-4-ones increased in the vascular sap and root exudates. The role of N-hydroxycinnamoyltyramines in plant–herbivore interactions is unknown, and we therefore tested the effect of the dominating p-coumaroyltyramine on S. littoralis. Unexpectedly, p-coumaroyltyramine was metabolized by the larvae and increased larval growth, possibly by providing additional nitrogen to the insect. Taken together, this study illustrates that herbivore attack leads to the induction of metabolites that can have contrasting effects on herbivore resistance in the leaves and roots.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ground based radial velocity (RV) searches continue to discover exoplanets below Neptune mass down to Earth mass. Furthermore, ground- based transit searches now reach milli-mag photometric precision and can dis- cover Neptune size planets around bright stars. These searches will find exo- planets around bright stars anywhere on the sky, their discoveries representing prime science targets for further study due to the proximity and brightness of their host stars. A mission for transit follow-up measurements of these prime targets is currently lacking. The first ESA S-class mission CHEOPS (CHarac- terizing ExoPlanet Satellite) will fill this gap. It will perform ultra-high preci- sion photometric monitoring of selected bright target stars almost anywhere on the sky with sufficient precision to detect Earth-sized transits. It will be able to detect transits of RV-planets by photometric monitoring if the geometric con- figuration results in a transit. For Hot Neptunes discovered from the ground, CHEOPS will be able to improve the transit light curve so that the radius can be determined precisely. Because of the host stars’ brightness, high precision RV measurements will be possible for all targets. All planets observed in tran- sit by CHEOPS will be validated and their masses will be known. This will provide valuable data for constraining the mass-radius relation of exoplanets, especially in the Neptune-mass regime. During the planned 3.5 year mission, about 500 targets will be observed. There will be 20% of open time available for the community to develop new science programmes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

As the number of space debris is increasing in the geostationary ring, it becomes mandatory for any satellite operator to avoid any collisions. Space debris in geosynchronous orbits may be observed with optical telescopes. Other than radar, that requires very large dishes and transmission powers for sensing high-altitude objects, optical observations do not depend on active illumination from ground and may be performed with notably smaller apertures. The detection size of an object depends on the aperture of the telescope, sky background and exposure time. With a telescope of 50 cm aperture, objects down to approximately 50 cm may be observed. This size is regarded as a threshold for the identification of hazardous objects and the prevention of potentially catastrophic collisions in geostationary orbits. In collaboration with the Astronomical Institute of the University of Bern (AIUB), the German Space Operations Center (GSOC) is building a small aperture telescope to demonstrate the feasibility of optical surveillance of the geostationary ring. The telescope will be located in the southern hemisphere and complement an existing telescope in the northern hemisphere already operated by AIUB. These two telescopes provide an optimum coverage of European GEO satellites and enable a continuous monitoring independent of seasonal limitations. The telescope will be operated completely automatically. The automated operations should be demonstrated covering the full range of activities including scheduling of observations, telescope and camera control as well as data processing.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Psychosen zählen zu den kostenträchtigsten Erkrankungen mit gravierenden Behinderungsfolgen, insbesondere bei Erstmanifestation im Kindes- und Jugendalter und verzögerter Behandlungsaufnahme. Seit den 1990er Jahren wurden daher Anstrengungen unternommen, die Behandlung frühzeitiger zu initiieren, wenn möglich vor der Erstmanifestation. Für die symptomatische Früherkennung wurden zwei alternative Ansätze verfolgt: der "ultra-high risk" (UHR) Ansatz, der Hauptsächlich auf abgeschwächten psychotischen und schizotyischen Symptomen beruht und der Basissymptom-Ansatz, der vorwiegend auf feinen selbst wahrgenommenen Störungen in Denkprozessen basiert. Basierend auf den in den letzten 20 Jahren gesammelten Befunden wurde im Februar 2015 im Rahmen des "Guidance" Projekts der EPA nun erstmals detaillierte klinische Empfehlungen für die Früherkennung und die Frühbehandlung (pharmakologisch und psychotherapeutisch) von Psychosen vorgelegt, die auch entwicklungsspezifischen Besonderheiten Rechnung tragen.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE Arthroscopy is "the gold standard" for the diagnosis of knee cartilage lesions. However, it is invasive and expensive, and displays all the potential complications of an open surgical procedure. Ultra-high-field MRI now offers good opportunities for the indirect assessment of the integrity and structural changes of joint cartilage of the knee. The goal of the present study is to determine the site of early cartilaginous lesions in adults with non-traumatic knee pain. METHODS 3-T MRI examinations of 200 asymptomatic knees with standard and three-dimensional double-echo steady-state (3D-DESS) cartilage-specific sequences were prospectively studied for early degenerative lesions of the tibiofemoral joint. Lesions were classified and mapped using the modified Outerbridge and modified International Cartilage Repair Society classifications. RESULTS A total of 1437 lesions were detected: 56.1% grade I, 33.5% grade II, 7.2% grade III and 3.3% grade IV. Cartographically, grade I lesions were most common in the anteromedial tibial areas; grade II lesions in the anteromedial L5 femoral areas; and grade III in the centromedial M2 femoral areas. CONCLUSION 3-T MRI with standard and 3D-DESS cartilage-specific sequences demonstrated that areas predisposed to early osteoarthritis are the central, lateral and ventromedial tibial plateau, as well as the central and medial femoral condyle. ADVANCES IN KNOWLEDGE In contrast with previous studies reporting early cartilaginous lesions in the medial tibial compartment and/or in the medial femoral condyle, this study demonstrates that, regardless of grade, lesions preferentially occur at the L5 and M4 tibial and L5 and L2 femoral areas of the knee joint.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Parylenes are poly(p-xylylene) polymers that are widely used as moisture barriers and in biomedicine because of their good biocompatibility. We have investigated MeV ion beam lithography using 16O+ ions for writing defined patterns in Parylene-C, which is evaluated as a coating material for the Cochlear Implant (CI) electrode array, a neuroprosthesis to treat some forms of deafness. Parylene-C and -F on silicon and glass substrates as well as 50 μm thick PTFE were irradiated to different fluences (1×1013-1×10161×1013-1×1016 1 MeV 16O+ ions cm−2) through aperture masks under high vacuum and a low pressure (<10−3 mbar) oxygen atmosphere. Biocompatibility of the irradiated and unirradiated surfaces was tested by cell-counting to determine the proliferation of murine spiral ganglion cells. The results reveal that an oxygen ion beam can be used to pattern Parylene-C and -F without using a liquid solvent developer in a similar manner to PTFE but with a ∼25× smaller removal rate. Biocompatibility tests showed no difference in cell adhesion between irradiated and unirradiated areas or ion fluence dependence. Coating the Parylene surface with an adhesion-promoting protein mixture had a much greater effect on cell proliferation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The majority of first-episode psychoses are preceded by a prodromal phase that is several years on average, frequently leads to some decline in psychosocial functioning and offers the opportunity for early detection within the framework of an indicated prevention. To this, two approaches are currently mainly followed. The ultra-high-risk (UHR) criteria were explicitly developed to predict first-episode psychosis within 12 months, and indeed the majority of conversions in clinical UHR samples seem to occur within the first 12 months of initial assessment. Their main criterion, the attenuated psychotic symptoms criterion, captures symptoms that resemble positive symptoms of psychosis (i.e. delusions, hallucinations and formal thought disorders) with the exception that some level of insight is still maintained, and these frequently compromise functioning already. In contrast, the basic symptom criteria try to catch patients at increased risk of psychoses at the earliest possible time, i.e. ideally when only the first subtle disturbances in information processing have developed that are experienced with full insight and do not yet overload the person's coping abilities, and thus have not yet resulted in any functional decline. First results from prospective studies not only support this view, but indicate that the combination of both approaches might be a more favorable way to increase sensitivity and detect risk earlier, as well as to establish a change-sensitive risk stratification approach.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES The objective was to evaluate homeopathic basic research studies that use plant-based bioassays. With this in view, a compilation was made of the findings of three systematic literature reviews covering plant-based bioassays in the three fields of healthy, abiotically, or biotically stressed plants. This compilation focused on investigations using advanced experimental methods and detailed descriptions, also with the aim of supporting the design of future experiments. METHODS Publications included had to report on studies into the effects of homeopathic preparations on whole plants, seeds, plant parts and cells. Outcomes had to be measured by established procedures and statistically evaluated. A Manuscript Information Score (MIS) was applied using predefined criteria to identify publications with sufficient information for adequate interpretation (MIS ≥ 5). Additional evaluation focused on the use of adequate controls to investigate specific effects of homeopathic preparations, and on the use of systematic negative control (SNC) experiments to ensure the stability of the bioassay. Only a fraction of the studies reported here were performed with 'ultra high' dilutions, whereas other studies were performed with moderate or high dilutions. RESULTS A total of 157 publications were identified, describing a total of 167 experimental studies. 84 studies included statistics and 48 had a MIS ≥ 5, thus allowing adequate interpretation. 29 studies had adequate controls to identify specific effects of homeopathic preparations, and reported significant effects of decimal and centesimal homeopathic potencies, including dilution levels beyond Avogadro's number. 10 studies reported use of SNC experiments, yielding evidence for the stability of the experimental set-up. CONCLUSION Plant models appear to be a useful approach for investigating basic research questions relating to homeopathic preparations, but more independent replication trials are needed in order to verify the results found in single experiments. Adequate controls and SNC experiments should be implemented on a routine basis to exclude false-positive results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE The aim of this study was to compare quantitative and semiquantitative parameters (signal-to-noise ratio [SNR], contrast-to-noise ratio [CNR], image quality, diagnostic confidence) from a standard brain magnetic resonance imaging examination encompassing common neurological disorders such as demyelinating disease, gliomas, cerebrovascular disease, and epilepsy, with comparable sequence protocols and acquisition times at 3 T and at 7 T. MATERIALS AND METHODS Ten healthy volunteers and 4 subgroups of 40 patients in total underwent comparable magnetic resonance protocols with standard diffusion-weighted imaging, 2D and 3D turbo spin echo, 2D and 3D gradient echo and susceptibility-weighted imaging of the brain (10 sequences) at 3 T and 7 T. The subgroups comprised patients with either lesional (n = 5) or nonlesional (n = 4) epilepsy, intracerebral tumors (n = 11), demyelinating disease (n = 11) (relapsing-remitting multiple sclerosis [MS, n = 9], secondary progressive MS [n = 1], demyelinating disease not further specified [n = 1]), or chronic cerebrovascular disorders [n = 9]). For quantitative analysis, SNR and CNR were determined. For a semiquantitative assessment of the diagnostic confidence, a 10-point scale diagnostic confidence score (DCS) was applied. Two experienced radiologists with additional qualification in neuroradiology independently assessed, blinded to the field strength, 3 pathology-specific imaging criteria in each of the 4 disease groups and rated their diagnostic confidence. The overall image quality was semiquantitatively assessed using a 4-point scale taking into account whether diagnostic decision making was hampered by artifacts or not. RESULTS Without correction for spatial resolution, SNR was higher at 3 T except in the T2 SPACE 3D, DWI single shot, and DIR SPACE 3D sequences. The SNR corrected by the ratio of 3 T/7 T voxel sizes was higher at 7 T than at 3 T in 10 of 11 sequences (all except for T1 MP2RAGE 3D).In CNR, there was a wide variation between sequences and patient cohorts, but average CNR values were broadly similar at 3 T and 7 T.DCS values for all 4 pathologic entities were higher at 7 T than at 3 T. The DCS was significantly higher at 7 T for diagnosis and exclusion of cortical lesions in vascular disease. A tendency to higher DCS at 7 T for cortical lesions in MS was observed, and for the depiction of a central vein and iron deposits within MS lesions. Despite motion artifacts, DCS values were higher at 7 T for the diagnosis and exclusion of hippocampal sclerosis in mesial temporal lobe epilepsy (improved detection of the hippocampal subunits). Interrater agreement was 69.7% at 3 T and 93.3% at 7 T. There was no significant difference in the overall image quality score between 3 T and 7 T taking into account whether diagnostic decision making was hampered by artifacts or not. CONCLUSIONS Ultra-high-field magnetic resonance imaging at 7 T compared with 3 T yielded an improved diagnostic confidence in the most frequently encountered neurologic disorders. Higher spatial resolution and contrast were identified as the main contributory factors.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

To study the effects of a milking system that partially compensates for milk flow-dependent vacuum loss compared with a standard (high-line) milking unit in a tie-stall barn, milk flow and vacuum patterns were recorded in 10 cows during machine milking with 2 milking systems in a crossover design for 7 d each. Before and after each treatment period postmilking teat condition was recorded by ultrasound cross-sectioning. Additionally, 2 methods to measure teat tissue condition were compared: longitudinal teat ultrasound cross-sectioning and teat tissue density measurements with the spring-loaded caliper (cutimeter method). The partial compensation of milk flow-dependent vacuum loss caused an elevation of the peak flow rate (4.74+/-0.08 vs. 4.29+/-0.07 kg/min) and a shorter duration of plateau (1.57+/-0.06 vs. 1.96+/-0.07 min) compared with the standard milking system. Total milk yield, duration of incline and decline of milk flow, average milk flow, time until peak flow rate, main milking time, and total milking time did not differ between treatments (overall means: 13.75+/-0.17 kg; 0.65+/-0.01 min; 2.88+/-0.09 min; 2.82+/-0.05 kg/min; 1.65+/-0.03 min; 5.23+/-0.09 min, and 5.30+/-0.10 min, respectively). The vacuum drop in the short milk tube during periods of high milk flow was less in the compensating vacuum than in the standard milking system (11+/-1.1 vs. 15+/-0.7 kPa). Teat measures as determined by ultrasound remained unchanged over the entire experimental period with both milking systems. Postmilking teat tissue measures including their recovery within 20 min after the end of milking show a correlation (0.85 and 0.71, respectively) between the methods used (ultrasound and cutimeter method). In conclusion, a more constant vacuum at the teat tip (within the short milk tube) during periods of high milk flow affected milk flow patterns, mainly increasing peak flow rate. However, the reduced vacuum loss did not increase the overall speed of milking. In addition, effects of higher vacuum stability on teat condition and udder health were not obvious.