53 resultados para ultra-high strenth steel


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ground based radial velocity (RV) searches continue to discover exoplanets below Neptune mass down to Earth mass. Furthermore, ground- based transit searches now reach milli-mag photometric precision and can dis- cover Neptune size planets around bright stars. These searches will find exo- planets around bright stars anywhere on the sky, their discoveries representing prime science targets for further study due to the proximity and brightness of their host stars. A mission for transit follow-up measurements of these prime targets is currently lacking. The first ESA S-class mission CHEOPS (CHarac- terizing ExoPlanet Satellite) will fill this gap. It will perform ultra-high preci- sion photometric monitoring of selected bright target stars almost anywhere on the sky with sufficient precision to detect Earth-sized transits. It will be able to detect transits of RV-planets by photometric monitoring if the geometric con- figuration results in a transit. For Hot Neptunes discovered from the ground, CHEOPS will be able to improve the transit light curve so that the radius can be determined precisely. Because of the host stars’ brightness, high precision RV measurements will be possible for all targets. All planets observed in tran- sit by CHEOPS will be validated and their masses will be known. This will provide valuable data for constraining the mass-radius relation of exoplanets, especially in the Neptune-mass regime. During the planned 3.5 year mission, about 500 targets will be observed. There will be 20% of open time available for the community to develop new science programmes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: Selective retina therapy (SRT) is a novel treatment for retinal pathologies, solely targeting the retinal pigment epithelium (RPE). During SRT, the detection of an immediate tissue reaction is challenging as tissue effects remain limited to intracellular RPE photodisruption. Time-resolved ultra-high axial resolution optical coherence tomography (OCT) is thus evaluated for the monitoring of dynamic optical changes at and around the RPE during SRT. Methods: An experimental OCT system with an ultra-high axial resolution of 1.78 µm was combined with an SRT system and time-resolved OCT M-scans of the target area were recorded from four patients undergoing SRT. OCT scans were analyzed and OCT morphology was correlated with findings in fluorescein angiography, fundus photography and cross-sectional OCT. Results: In cases where the irradiation caused RPE damage proven by fluorescein angiography, the lesions were well discernible in time-resolved OCT images but remained invisible in fundus photography and cross-sectional OCT acquired after treatment. If RPE damage was introduced, all applied SRT pulses led to detectable signal changes in the time-resolved OCT images. The extent of optical signal variation seen in the OCT data appeared to scale with the applied SRT pulse energy. Conclusion: The first clinical results proved that successful SRT irradiation induces detectable changes in the OCT M-scan signal while it remains invisible in conventional ophthalmoscopic imaging. Thus, real-time high-resolution OCT is a promising modality to monitor and analyze tissue effects introduced by selective retina therapy and may be used to guide SRT in an automatic feedback mode.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Psychosen zählen zu den kostenträchtigsten Erkrankungen mit gravierenden Behinderungsfolgen, insbesondere bei Erstmanifestation im Kindes- und Jugendalter und verzögerter Behandlungsaufnahme. Seit den 1990er Jahren wurden daher Anstrengungen unternommen, die Behandlung frühzeitiger zu initiieren, wenn möglich vor der Erstmanifestation. Für die symptomatische Früherkennung wurden zwei alternative Ansätze verfolgt: der "ultra-high risk" (UHR) Ansatz, der Hauptsächlich auf abgeschwächten psychotischen und schizotyischen Symptomen beruht und der Basissymptom-Ansatz, der vorwiegend auf feinen selbst wahrgenommenen Störungen in Denkprozessen basiert. Basierend auf den in den letzten 20 Jahren gesammelten Befunden wurde im Februar 2015 im Rahmen des "Guidance" Projekts der EPA nun erstmals detaillierte klinische Empfehlungen für die Früherkennung und die Frühbehandlung (pharmakologisch und psychotherapeutisch) von Psychosen vorgelegt, die auch entwicklungsspezifischen Besonderheiten Rechnung tragen.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE Arthroscopy is "the gold standard" for the diagnosis of knee cartilage lesions. However, it is invasive and expensive, and displays all the potential complications of an open surgical procedure. Ultra-high-field MRI now offers good opportunities for the indirect assessment of the integrity and structural changes of joint cartilage of the knee. The goal of the present study is to determine the site of early cartilaginous lesions in adults with non-traumatic knee pain. METHODS 3-T MRI examinations of 200 asymptomatic knees with standard and three-dimensional double-echo steady-state (3D-DESS) cartilage-specific sequences were prospectively studied for early degenerative lesions of the tibiofemoral joint. Lesions were classified and mapped using the modified Outerbridge and modified International Cartilage Repair Society classifications. RESULTS A total of 1437 lesions were detected: 56.1% grade I, 33.5% grade II, 7.2% grade III and 3.3% grade IV. Cartographically, grade I lesions were most common in the anteromedial tibial areas; grade II lesions in the anteromedial L5 femoral areas; and grade III in the centromedial M2 femoral areas. CONCLUSION 3-T MRI with standard and 3D-DESS cartilage-specific sequences demonstrated that areas predisposed to early osteoarthritis are the central, lateral and ventromedial tibial plateau, as well as the central and medial femoral condyle. ADVANCES IN KNOWLEDGE In contrast with previous studies reporting early cartilaginous lesions in the medial tibial compartment and/or in the medial femoral condyle, this study demonstrates that, regardless of grade, lesions preferentially occur at the L5 and M4 tibial and L5 and L2 femoral areas of the knee joint.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The majority of first-episode psychoses are preceded by a prodromal phase that is several years on average, frequently leads to some decline in psychosocial functioning and offers the opportunity for early detection within the framework of an indicated prevention. To this, two approaches are currently mainly followed. The ultra-high-risk (UHR) criteria were explicitly developed to predict first-episode psychosis within 12 months, and indeed the majority of conversions in clinical UHR samples seem to occur within the first 12 months of initial assessment. Their main criterion, the attenuated psychotic symptoms criterion, captures symptoms that resemble positive symptoms of psychosis (i.e. delusions, hallucinations and formal thought disorders) with the exception that some level of insight is still maintained, and these frequently compromise functioning already. In contrast, the basic symptom criteria try to catch patients at increased risk of psychoses at the earliest possible time, i.e. ideally when only the first subtle disturbances in information processing have developed that are experienced with full insight and do not yet overload the person's coping abilities, and thus have not yet resulted in any functional decline. First results from prospective studies not only support this view, but indicate that the combination of both approaches might be a more favorable way to increase sensitivity and detect risk earlier, as well as to establish a change-sensitive risk stratification approach.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES The objective was to evaluate homeopathic basic research studies that use plant-based bioassays. With this in view, a compilation was made of the findings of three systematic literature reviews covering plant-based bioassays in the three fields of healthy, abiotically, or biotically stressed plants. This compilation focused on investigations using advanced experimental methods and detailed descriptions, also with the aim of supporting the design of future experiments. METHODS Publications included had to report on studies into the effects of homeopathic preparations on whole plants, seeds, plant parts and cells. Outcomes had to be measured by established procedures and statistically evaluated. A Manuscript Information Score (MIS) was applied using predefined criteria to identify publications with sufficient information for adequate interpretation (MIS ≥ 5). Additional evaluation focused on the use of adequate controls to investigate specific effects of homeopathic preparations, and on the use of systematic negative control (SNC) experiments to ensure the stability of the bioassay. Only a fraction of the studies reported here were performed with 'ultra high' dilutions, whereas other studies were performed with moderate or high dilutions. RESULTS A total of 157 publications were identified, describing a total of 167 experimental studies. 84 studies included statistics and 48 had a MIS ≥ 5, thus allowing adequate interpretation. 29 studies had adequate controls to identify specific effects of homeopathic preparations, and reported significant effects of decimal and centesimal homeopathic potencies, including dilution levels beyond Avogadro's number. 10 studies reported use of SNC experiments, yielding evidence for the stability of the experimental set-up. CONCLUSION Plant models appear to be a useful approach for investigating basic research questions relating to homeopathic preparations, but more independent replication trials are needed in order to verify the results found in single experiments. Adequate controls and SNC experiments should be implemented on a routine basis to exclude false-positive results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE The aim of this study was to compare quantitative and semiquantitative parameters (signal-to-noise ratio [SNR], contrast-to-noise ratio [CNR], image quality, diagnostic confidence) from a standard brain magnetic resonance imaging examination encompassing common neurological disorders such as demyelinating disease, gliomas, cerebrovascular disease, and epilepsy, with comparable sequence protocols and acquisition times at 3 T and at 7 T. MATERIALS AND METHODS Ten healthy volunteers and 4 subgroups of 40 patients in total underwent comparable magnetic resonance protocols with standard diffusion-weighted imaging, 2D and 3D turbo spin echo, 2D and 3D gradient echo and susceptibility-weighted imaging of the brain (10 sequences) at 3 T and 7 T. The subgroups comprised patients with either lesional (n = 5) or nonlesional (n = 4) epilepsy, intracerebral tumors (n = 11), demyelinating disease (n = 11) (relapsing-remitting multiple sclerosis [MS, n = 9], secondary progressive MS [n = 1], demyelinating disease not further specified [n = 1]), or chronic cerebrovascular disorders [n = 9]). For quantitative analysis, SNR and CNR were determined. For a semiquantitative assessment of the diagnostic confidence, a 10-point scale diagnostic confidence score (DCS) was applied. Two experienced radiologists with additional qualification in neuroradiology independently assessed, blinded to the field strength, 3 pathology-specific imaging criteria in each of the 4 disease groups and rated their diagnostic confidence. The overall image quality was semiquantitatively assessed using a 4-point scale taking into account whether diagnostic decision making was hampered by artifacts or not. RESULTS Without correction for spatial resolution, SNR was higher at 3 T except in the T2 SPACE 3D, DWI single shot, and DIR SPACE 3D sequences. The SNR corrected by the ratio of 3 T/7 T voxel sizes was higher at 7 T than at 3 T in 10 of 11 sequences (all except for T1 MP2RAGE 3D).In CNR, there was a wide variation between sequences and patient cohorts, but average CNR values were broadly similar at 3 T and 7 T.DCS values for all 4 pathologic entities were higher at 7 T than at 3 T. The DCS was significantly higher at 7 T for diagnosis and exclusion of cortical lesions in vascular disease. A tendency to higher DCS at 7 T for cortical lesions in MS was observed, and for the depiction of a central vein and iron deposits within MS lesions. Despite motion artifacts, DCS values were higher at 7 T for the diagnosis and exclusion of hippocampal sclerosis in mesial temporal lobe epilepsy (improved detection of the hippocampal subunits). Interrater agreement was 69.7% at 3 T and 93.3% at 7 T. There was no significant difference in the overall image quality score between 3 T and 7 T taking into account whether diagnostic decision making was hampered by artifacts or not. CONCLUSIONS Ultra-high-field magnetic resonance imaging at 7 T compared with 3 T yielded an improved diagnostic confidence in the most frequently encountered neurologic disorders. Higher spatial resolution and contrast were identified as the main contributory factors.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE To evaluate the role of an ultra-low-dose dual-source CT coronary angiography (CTCA) scan with high pitch for delimiting the range of the subsequent standard CTCA scan. METHODS 30 patients with an indication for CTCA were prospectively examined using a two-scan dual-source CTCA protocol (2.0 × 64.0 × 0.6 mm; pitch, 3.4; rotation time of 280 ms; 100 kV): Scan 1 was acquired with one-fifth of the tube current suggested by the automatic exposure control software [CareDose 4D™ (Siemens Healthcare, Erlangen, Germany) using 100 kV and 370 mAs as a reference] with the scan length from the tracheal bifurcation to the diaphragmatic border. Scan 2 was acquired with standard tube current extending with reduced scan length based on Scan 1. Nine central coronary artery segments were analysed qualitatively on both scans. RESULTS Scan 2 (105.1 ± 10.1 mm) was significantly shorter than Scan 1 (127.0 ± 8.7 mm). Image quality scores were significantly better for Scan 2. However, in 5 of 6 (83%) patients with stenotic coronary artery disease, a stenosis was already detected in Scan 1 and in 13 of 24 (54%) patients with non-stenotic coronary arteries, a stenosis was already excluded by Scan 1. Using Scan 2 as reference, the positive- and negative-predictive value of Scan 1 was 83% (5 of 6 patients) and 100% (13 of 13 patients), respectively. CONCLUSION An ultra-low-dose CTCA planning scan enables a reliable scan length reduction of the following standard CTCA scan and allows for correct diagnosis in a substantial proportion of patients. ADVANCES IN KNOWLEDGE Further dose reductions are possible owing to a change in the individual patient's imaging strategy as a prior ultra-low-dose CTCA scan may already rule out the presence of a stenosis or may lead to a direct transferal to an invasive catheter procedure.