118 resultados para stereotactic ablative radiotherapy
Resumo:
Retaining effective swallowing is a key element when optimising outcomes in the management of head and neck cancer. We report the functional swallowing outcomes for a cohort of 31 individuals with advanced oral and oropharyngeal cancer who underwent free or pedicled flap reconstruction of surgical defects. Swallowing was assessed pre and immediately post surgery and at four months post treatment. Swallowing assessments were related to site, size and volume of defect and composition of flap reconstruction. The effect of radiotherapy on swallowing was assessed among 17 of the 31 individuals who were submitted to radiotherapy after surgery. The proportion of patients on a total oral diet four months post treatment varied significantly by site of defect (Fishers exact test p=0.006), from 100% (7/7) of patients with a lateral defect to only 22% (2/9) of patients with a central defect. The proportion of patients on a total oral diet at the final assessment did not vary by flap reconstruction or radiotherapy.
Resumo:
BACKGROUND: Catheter ablation has evolved as a possible curative treatment modality for supraventricular tachycardias (SVT) in patients with univentricular heart. However, the long-term outcome of ablation procedures is unknown. We evaluated the procedural and long-term outcome of ablative therapy of late postoperative SVT in patients with univentricular heart. METHODS AND RESULTS: Patients with univentricular heart (n=19, 11 male; age, 29+/-9 years) referred for ablation of SVT were studied. Ablation was guided by 3D electroanatomic mapping in all but 2 procedures. A total of 41 SVT were diagnosed as intra-atrial reentrant tachycardia (n=30; cycle length, 310+/-68 ms), typical atrial flutter (n=4; cycle length, 288+/-42 ms), focal atrial tachycardia (n=6; cycle length, 400+/-60 ms), and atrial fibrillation (n=1). Ablation was successful in 73% of intra-atrial reentrant tachycardia, 75% of atrial flutter, and all focal atrial tachycardia and focal atrial fibrillation. During the follow-up period of 53+/-34 months, 2 patients were lost to follow-up, 3 died of heart failure, 2 underwent heart transplantation, and 1 underwent conduit replacement. Of the remaining group, 8 had sinus rhythm and 3 had SVT. CONCLUSIONS: Focal and reentrant mechanisms underlie postoperative SVT in patients with univentricular heart. Successive SVT developing over time may be caused by different mechanisms. Ablative therapy is potentially curative, with a procedural success rate of 78%. In patients who had multiple ablation procedures, the SVT originated from different atrial sites, suggesting that these new SVT were caused by progressive atrial disease. Despite recurrent SVT, sinus rhythm at the end of the follow-up period was achieved in 72%.
Resumo:
PURPOSE: The aim of this study was to assess the outcome of patients with primary spinal myxopapillary ependymoma (MPE). MATERIALS AND METHODS: Data from a series of 85 (35 females, 50 males) patients with spinal MPE were collected in this retrospective multicenter study. Thirty-eight (45%) underwent surgery only and 47 (55%) received postoperative radiotherapy (RT). Median administered radiation dose was 50.4 Gy (range, 22.2-59.4). Median follow-up of the surviving patients was 60.0 months (range, 0.2-316.6). RESULTS: The 5-year progression-free survival (PFS) was 50.4% and 74.8% for surgery only and surgery with postoperative low- (<50.4 Gy) or high-dose (>or=50.4 Gy) RT, respectively. Treatment failure was observed in 24 (28%) patients. Fifteen patients presented treatment failure at the primary site only, whereas 2 and 1 patients presented with brain and distant spinal failure only. Three and 2 patients with local failure presented with concomitant spinal distant seeding and brain failure, respectively. One patient failed simultaneously in the brain and spine. Age greater than 36 years (p = 0.01), absence of neurologic symptoms at diagnosis (p = 0.01), tumor size >or=25 mm (p = 0.04), and postoperative high-dose RT (p = 0.05) were variables predictive of improved PFS on univariate analysis. In multivariate analysis, only postoperative high-dose RT was independent predictors of PFS (p = 0.04). CONCLUSIONS: The observed pattern of failure was mainly local, but one fifth of the patients presented with a concomitant spinal or brain component. Postoperative high-dose RT appears to significantly reduce the rate of tumor progression.
Resumo:
BACKGROUND: Stage IIIB non-small-cell lung cancer (NSCLC) is usually thought to be unresectable, and is managed with chemotherapy with or without radiotherapy. However, selected patients might benefit from surgical resection after neoadjuvant chemotherapy and radiotherapy. The aim of this multicentre, phase II trial was to assess the efficacy and toxicity of a neoadjuvant chemotherapy and radiotherapy followed by surgery in patients with technically operable stage IIIB NSCLC. METHODS: Between September, 2001, and May, 2006, patients with pathologically proven and technically resectable stage IIIB NSCLC were sequentially treated with three cycles of neoadjuvant chemotherapy (cisplatin with docetaxel), immediately followed by accelerated concomitant boost radiotherapy (44 Gy in 22 fractions) and definitive surgery. The primary endpoint was event-free survival at 12 months. Efficacy analyses were done by intention to treat. This trial is registered with ClinicalTrials.gov, number NCT00030810. FINDINGS: 46 patients were enrolled, with a median age of 60 years (range 28-70). 13 (28%) patients had N3 disease, 36 (78%) had T4 disease. All patients received chemotherapy; 35 (76%) patients received radiotherapy. The main toxicities during chemotherapy were neutropenia (25 patients [54%] at grade 3 or 4) and febrile neutropenia (nine [20%]); the main toxicity after radiotherapy was oesophagitis (ten patients [29%]; nine grade 2, one grade 3). 35 patients (76%) underwent surgery, with pneumonectomy in 17 patients. A complete (R0) resection was achieved in 27 patients. Peri-operative complications occurred in 14 patients, including two deaths (30-day mortality 5.7%). Seven patients required a second surgical intervention. Pathological mediastinal downstaging was seen in 11 of the 28 patients who had lymph-node involvement at enrolment, a complete pathological response was seen in six patients. Event-free survival at 12 months was 54% (95% CI 39-67). After a median follow-up of 58 months, the median overall survival was 29 months (95% CI 16.1-NA), with survival at 1, 3, and 5 years of 67% (95% CI 52-79), 47% (32-61), and 40% (24-55). INTERPRETATION: A treatment strategy of neoadjuvant chemotherapy and radiotherapy followed by surgery is feasible in selected patients. Toxicity is considerable, but manageable. Survival compares favourably with historical results of combined treatment for less advanced stage IIIA disease. FUNDING: Swiss Group for Clinical Cancer Research (SAKK) and an unrestricted educational grant by Sanofi-Aventis (Switzerland).
Resumo:
We aimed to examine different intratumoral changes after single-dose and fractionated radiotherapy, using diffusion-weighted (DW) and dynamic contrast-enhanced (DCE) MRI in a rat rhabdomyosarcoma model. Four WAG/Rij rats with rhabdomyosarcomas in the flanks received single-dose radiotherapy of 8 Gy, and four others underwent fractionated radiotherapy (five times 3 Gy). In rats receiving single-dose radiotherapy, a significant perfusion decrease was found in the first 2 days post-treatment, with slow recuperation afterwards. No substantial diffusion changes could be seen; tumor growth delay was 12 days. The rats undergoing fractionated radiotherapy showed a similar perfusion decrease early after the treatment. However, a very strong increase in apparent diffusion coefficient occurred in the first 10 days; growth delay was 18 days. DW-MRI and DCE-MRI can be used to show early tumoral changes induced by radiotherapy. Single-dose and fractionated radiotherapy induce an immediate perfusion effect, while the latter induces more intratumoral necrosis.
Resumo:
BACKGROUND Neuronavigation has become an intrinsic part of preoperative surgical planning and surgical procedures. However, many surgeons have the impression that accuracy decreases during surgery. OBJECTIVE To quantify the decrease of neuronavigation accuracy and identify possible origins, we performed a retrospective quality-control study. METHODS Between April and July 2011, a neuronavigation system was used in conjunction with a specially prepared head holder in 55 consecutive patients. Two different neuronavigation systems were investigated separately. Coregistration was performed with laser-surface matching, paired-point matching using skin fiducials, anatomic landmarks, or bone screws. The initial target registration error (TRE1) was measured using the nasion as the anatomic landmark. Then, after draping and during surgery, the accuracy was checked at predefined procedural landmark steps (Mayfield measurement point and bone measurement point), and deviations were recorded. RESULTS After initial coregistration, the mean (SD) TRE1 was 2.9 (3.3) mm. The TRE1 was significantly dependent on patient positioning, lesion localization, type of neuroimaging, and coregistration method. The following procedures decreased neuronavigation accuracy: attachment of surgical drapes (DTRE2 = 2.7 [1.7] mm), skin retractor attachment (DTRE3 = 1.2 [1.0] mm), craniotomy (DTRE3 = 1.0 [1.4] mm), and Halo ring installation (DTRE3 = 0.5 [0.5] mm). Surgery duration was a significant factor also; the overall DTRE was 1.3 [1.5] mm after 30 minutes and increased to 4.4 [1.8] mm after 5.5 hours of surgery. CONCLUSION After registration, there is an ongoing loss of neuronavigation accuracy. The major factors were draping, attachment of skin retractors, and duration of surgery. Surgeons should be aware of this silent loss of accuracy when using neuronavigation.
Resumo:
Purpose: To investigate the dosimetric properties of an electronic portal imaging device (EPID) for electron beam detection and to evaluate its potential for quality assurance (QA) of modulated electron radiotherapy (MERT). Methods: A commercially available EPID was used to detect electron beams shaped by a photon multileaf collimator (MLC) at a source-surface distance of 70 cm. The fundamental dosimetric properties such as reproducibility, dose linearity, field size response, energy response, and saturation were investigated for electron beams. A new method to acquire the flood-field for the EPID calibration was tested. For validation purpose, profiles of open fields and various MLC fields (square and irregular) were measured with a diode in water and compared to the EPID measurements. Finally, in order to use the EPID for QA of MERT delivery, a method was developed to reconstruct EPID two-dimensional (2D) dose distributions in a water-equivalent depth of 1.5 cm. Comparisons were performed with film measurement for static and dynamic monoenergy fields as well as for multienergy fields composed by several segments of different electron energies. Results: The advantageous EPID dosimetric properties already known for photons as reproducibility, linearity with dose, and dose rate were found to be identical for electron detection. The flood-field calibration method was proven to be effective and the EPID was capable to accurately reproduce the dose measured in water at 1.0 cm depth for 6 MeV, 1.3 cm for 9 MeV, and 1.5 cm for 12, 15, and 18 MeV. The deviations between the output factors measured with EPID and in water at these depths were within ±1.2% for all the energies with a mean deviation of 0.1%. The average gamma pass rate (criteria: 1.5%, 1.5 mm) for profile comparison between EPID and measurements in water was better than 99% for all the energies considered in this study. When comparing the reconstructed EPID 2D dose distributions at 1.5 cm depth to film measurements, the gamma pass rate (criteria: 2%, 2 mm) was better than 97% for all the tested cases. Conclusions: This study demonstrates the high potential of the EPID for electron dosimetry, and in particular, confirms the possibility to use it as an efficient verification tool for MERT delivery.