48 resultados para parametric and nonparametric test


Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE Stress urinary incontinence (SUI) affects women of all ages including young athletes, especially those involved in high-impact sports. To date, hardly any studies are available testing pelvic floor muscles (PFM) during sports activities. The aim of this study was the description and reliability test of six PFM electromyography (EMG) variables during three different running speeds. The secondary objective was to evaluate whether there was a speed-dependent difference between the PFM activity variables. METHODS This trial was designed as an exploratory and reliability study including ten young healthy female subjects to characterize PFM pre-activity and reflex activity during running at 7, 9 and 11 km/h. Six variables for each running speed, averaged over ten steps per subject, were presented descriptively, tested regarding their reliability (Friedman, ICC, SEM, MD) and speed difference (Friedman). RESULTS PFM EMG variables varied between 67.6 and 106.1 %EMG, showed no systematic error and were low for SEM and MD using the single value model. Applying the average model over ten steps, ICC (3,k) were >0.75 and SEM and MD about 50 % lower than for the single value model. Activity was found to be highest in 11 km/h. CONCLUSION EMG variables showed excellent ICC and very low SEM and MD. Further studies should investigate inter-session reliability and PFM reactivity patterns of SUI patients using the average over ten steps for each variable as it showed very high ICC and very low SEM and MD. Subsequently, longer running distances and other high-impact sports disciplines could be studied.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The isotope composition of selenium (Se) can provide important constraints on biological, geochemical, and cosmochemical processes taking place in different reservoirs on Earth and during planet formation. To provide precise qualitative and quantitative information on these processes, accurate and highly precise isotope data need to be obtained. The currently applied ICP-MS methods for Se isotope measurements are compromised by the necessity to perform a large number of interference corrections. Differences in these correction methods can lead to discrepancies in published Se isotope values of rock standards which are significantly higher than the acclaimed precision. An independent analytical approach applying a double spike (DS) and state-of-the-art TIMS may yield better precision due to its smaller number of interferences and could test the accuracy of data obtained by ICP-MS approaches. This study shows that the precision of Se isotope measurements performed with two different Thermo Scientific™ Triton™ Plus TIMS is distinctly deteriorated by about ±1‰ (2 s.d.) due to δ80/78Se by a memory Se signal of up to several millivolts and additional minor residual mass bias which could not be corrected for with the common isotope fractionation laws. This memory Se has a variable isotope composition with a DS fraction of up to 20% and accumulates with increasing number of measurements. Thus it represents an accumulation of Se from previous Se measurements with a potential addition from a sample or machine blank. Several cleaning techniques of the MS parts were tried to decrease the memory signal, but were not sufficient to perform precise Se isotope analysis. If these serious memory problems can be overcome in the future, the precision and accuracy of Se isotope analysis with TIMS should be significantly better than those of the current ICP-MS approaches.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE The aim of this study was to compare crestal bone-level changes, soft tissue parameters and implant success and survival between small-diameter implants made of titanium/zirconium (TiZr) alloy or of Grade IV titanium (Ti) in edentulous mandibles restored with removable overdentures. MATERIALS AND METHODS This was a randomized, controlled, double-blind, split-mouth multicenter clinical trial. Patients with edentulous mandibles received two Straumann bone-level implants (diameter 3.3 mm), one of Ti Grade IV (control) and one of TiZr (test), in the interforaminal region. Implants were loaded after 6-8 weeks and removable Locator-retained overdentures were placed within 2 weeks of loading. Modified plaque and sulcus bleeding indices, radiographic bone level, and implant survival and success were evaluated up to 36 months. RESULTS Of 91 treated patients, 75 completed the three-year follow-up. Three implants were lost (two control and one test implant). The survival rates were 98.7% and 97.3%, and the mean marginal bone level change was -0.78 ± 0.75 and -0.60 ± 0.71 mm for TiZr and Ti Grade IV implants. Most patients had a plaque score of 0 or 1 (54% for test and 51.7% for control), and a sulcus bleeding score of 0 (46.1% for test and 44.9% for control). No significant differences were found between the two implant types for bone-level change, soft tissue parameters, survival and success. CONCLUSIONS After 36 months, similar outcomes were found between Ti Grade IV and TiZr implants. The results confirm that the results seen at 12 months continue over time.