313 resultados para neutron tomography
Resumo:
The vascular tissue reaction to acute incomplete stent apposition (ISA) is not well known. The aim of this study was to characterize the vascular response to acute ISA in vivo and to look for predictors of incomplete healing.
Resumo:
The purpose of this study was to determine the influence of iodinated contrast agents on the formation of DNA double-strand breaks in vitro in lymphocytes and to verify these results in patients undergoing diagnostic computed tomography examinations. Blood samples were irradiated in vitro in the presence of iodinated X-ray contrast agent. Controls were irradiated without contrast agent. Fourteen patients were investigated using contrast-enhanced computed tomography (CT), and 14 other patients with unenhanced CT. Blood samples were taken prior to and 5 min and 1, 2 and 24 h after the CT examination. In these blood samples the average number of γH2Ax-foci per lymphocyte was enumerated by fluorescence microscopy. Statistical differences between foci numbers developed in the presence and absence of contrast agent were tested using an independent sample t-test. In vitro foci numbers after irradiation were significantly higher when contrast agent was present during irradiation. In vivo, γH2Ax-foci levels were 58% higher in patients undergoing contrast-enhanced CT compared with those undergoing unenhanced CT. In the presence of iodinated contrast agents DNA, damage is increased and the radiation dose is not the only factor affecting the amount of DNA damage. Individual patient characteristics and biological dosimetry applications, e.g. the analysis of γH2Ax-foci, have to be considered.
Meta-analysis: diagnostic performance of low-radiation-dose coronary computed tomography angiography
Resumo:
A new radiation dose-saving technique for noninvasive coronary artery imaging with computed tomography (CT) is available.
Resumo:
Background/Aims: To evaluate the alterations of mean foveal thickness (MFT) and visual acuity (VA) outcomes after uncomplicated cataract surgery in different groups of patients. Methods: This study included eyes of consecutive patients who underwent cataract surgery between November 2007 and June 2009. The patients included in the study were divided into 4 groups, as follows: history-free patients, patients with diabetes mellitus without macular involvement at baseline, patients with glaucoma, and patients with epiretinal membrane (ERM). Preoperatively and at 1, 3 and 6 months postoperatively, patients were evaluated for MFT by optical coherence tomography at the central 1-mm macular zone and for logarithm of the minimum angle of resolution best spectacle-corrected VA (BSCVA). Results: A total of 202 eyes were included in the study. MFT values demonstrated a statistically significant increase (p < 0.01) after cataract surgery in all groups at the first and third postoperative month. The history-free (p = 0.09) and glaucoma (p = 0.19) groups did not demonstrate a statistically significant difference in MFT values between the preoperative and 6-month measurements. MFT values 6 months after cataract surgery in the diabetes and ERM groups remained significantly higher (p < 0.01). Despite these findings, VA increased significantly (p < 0.01) in all groups at all postoperative follow-ups. Conclusions: MFT values increased significantly in all groups at the first and third months after cataract surgery. At 6 months, MFT values returned to preoperative levels in the history-free and glaucoma patients, while they remained significantly higher in the diabetic and ERM patients. Despite these macular alterations, BSCVA improved significantly after cataract surgery in all groups at all postoperative follow-ups.
Resumo:
Introduction Electrical impedance tomography (EIT) has been shown to be able to distinguish both ventilation and perfusion. With adequate filtering the regional distributions of both ventilation and perfusion and their relationships could be analysed. Several methods of separation have been suggested previously, including breath holding, electrocardiograph (ECG) gating and frequency filtering. Many of these methods require interventions inappropriate in a clinical setting. This study therefore aims to extend a previously reported frequency filtering technique to a spontaneously breathing cohort and assess the regional distributions of ventilation and perfusion and their relationship. Methods Ten healthy adults were measured during a breath hold and while spontaneously breathing in supine, prone, left and right lateral positions. EIT data were analysed with and without filtering at the respiratory and heart rate. Profiles of ventilation, perfusion and ventilation/perfusion related impedance change were generated and regions of ventilation and pulmonary perfusion were identified and compared. Results Analysis of the filtration technique demonstrated its ability to separate the ventilation and cardiac related impedance signals without negative impact. It was, therefore, deemed suitable for use in this spontaneously breathing cohort. Regional distributions of ventilation, perfusion and the combined ΔZV/ΔZQ were calculated along the gravity axis and anatomically in each position. Along the gravity axis, gravity dependence was seen only in the lateral positions in ventilation distribution, with the dependent lung being better ventilated regardless of position. This gravity dependence was not seen in perfusion. When looking anatomically, differences were only apparent in the lateral positions. The lateral position ventilation distributions showed a difference in the left lung, with the right lung maintaining a similar distribution in both lateral positions. This is likely caused by more pronounced anatomical changes in the left lung when changing positions. Conclusions The modified filtration technique was demonstrated to be effective in separating the ventilation and perfusion signals in spontaneously breathing subjects. Gravity dependence was seen only in ventilation distribution in the left lung in lateral positions, suggesting gravity based shifts in anatomical structures. Gravity dependence was not seen in any perfusion distributions.
Resumo:
We prospectively investigated the potential of positron emission tomography (PET) using the somatostatin receptor (SSTR) analogue ⁶⁸Ga-DOTATATE and 2-deoxy-2[¹⁸F]fluoro-D-glucose (¹⁸F-FDG) in diffuse parenchymal lung disease (DPLD). Twenty-six patients (mean age 68.9 ± 11.0 years) with DPLD were recruited for ⁶⁸Ga-DOTATATE and ¹⁸F-FDG combined PET/high-resolution computed tomography (HRCT) studies. Ten patients had idiopathic pulmonary fibrosis (IPF), 12 patients had nonspecific interstitial pneumonia (NSIP), and 4 patients had other forms of DPLD. Using PET, the pulmonary tracer uptake (maximum standardized uptake value [SUV(max)]) was calculated. The distribution of PET tracer was compared to the distribution of lung parenchymal changes on HRCT. All patients demonstrated increased pulmonary PET signal with ⁶⁸Ga-DOTATATE and ¹⁸F-FDG. The distribution of parenchymal uptake was similar, with both tracers corresponding to the distribution of HRCT changes. The mean SUV(max) was 2.2 ± 0.7 for ⁶⁸Ga-DOTATATE and 2.8 ± 1.0 (t-test, p = .018) for ¹⁸F-FDG. The mean ⁶⁸Ga-DOTATATE SUV(max) in IPF patients was 2.5 ± 0.9, whereas it was 2.0 ± 0.7 (p = .235) in NSIP patients. The correlation between ⁶⁸Ga-DOTATATE SUV(max) and gas transfer (transfer factor of the lung for carbon monoxide [TLCO]) was r = -.34 (p = .127) and r = -.49 (p = .028) between ¹⁸F-FDG SUV(max) and TLCO. We provide noninvasive in vivo evidence in humans showing that SSTRs may be detected in the lungs of patients with DPLD in a similar distribution to sites of increased uptake of ¹⁸F-FDG on PET.
Resumo:
The low-energy β− emitter 161Tb is very similar to 177Lu with respect to half-life, beta energy and chemical properties. However, 161Tb also emits a significant amount of conversion and Auger electrons. Greater therapeutic effect can therefore be expected in comparison to 177Lu. It also emits low-energy photons that are useful for gamma camera imaging. The 160Gd(n,γ)161Gd→161Tb production route was used to produce 161Tb by neutron irradiation of massive 160Gd targets (up to 40 mg) in nuclear reactors. A semiautomated procedure based on cation exchange chromatography was developed and applied to isolate no carrier added (n.c.a.) 161Tb from the bulk of the 160Gd target and from its stable decay product 161Dy. 161Tb was used for radiolabeling DOTA-Tyr3-octreotate; the radiolabeling profile was compared to the commercially available n.c.a. 177Lu. A 161Tb Derenzo phantom was imaged using a small-animal single-photon emission computed tomography camera. Up to 15 GBq of 161Tb was produced by long-term irradiation of Gd targets. Using a cation exchange resin, we obtained 80%–90% of the available 161Tb with high specific activity, radionuclide and chemical purity and in quantities sufficient for therapeutic applications. The 161Tb obtained was of the quality required to prepare 161Tb–DOTA-Tyr3-octreotate. We were able to produce 161Tb in n.c.a. form by irradiating highly enriched 160Gd targets; it can be obtained in the quantity and quality required for the preparation of 161Tb-labeled therapeutic agents.
Resumo:
A custom-made 228Th source of several MBq activity was produced for the Borexino experiment for studying the external background of the detector. The aim was to reduce the unwanted neutron emission produced via (alpha,n) reactions in ceramics used typically for commercial 228Th sources. For this purpose a ThCl4 solution was converted chemically into ThO2 and embedded into a gold foil. The paper describes the production and the characterization of the custom-made source by means of gamma-activity, dose rate and neutron source strength measurements. From gamma-spectroscopic measurements it was deduced that the activity transfer from the initial solution to the final source was >91% (at 68% C.L.) and the final activity was (5.41+-0.30) MBq. The dose rate was measured by two dosimeters yielding 12.1 mSv/h and 14.3 mSv/h in 1 cm distance. The neutron source strength of the 5.41 MBq 228Th source was determined as (6.59+-0.85)/sec.
Conceptual Design, Neutronic and Radioprotection Study of a Fast Neutron Irradiation Station at SINQ
Resumo:
The determination of root canal length is a significant outcome predictor for endodontic treatments. The aim of this prospective, controlled clinical study was to analyze endodontic working length measurements in preexisting cone-beam computed tomography (CBCT) scans and to compare them with clinical root canal length determination by using an electronic apex locator (EAL).
Resumo:
Foreign bodies are common findings in the maxillofacial region, most commonly the result of accidents and physical aggression. Among the objects frequently found in the orofacial tissues are fragments of metal, plastic, wood, and glass. Visualization and exact identification of the location of these objects can be challenging but is of major importance prior to surgical removal. The present case report describes the use of cone beam computed tomography to locate, visualize, and surgically remove glass particles in the oral cavity.
Resumo:
The purpose of the present study was to compare conventional intraoral periapical radiographs (PA) with limited cone beam computed tomography (CBCT) for evaluation of mandibular molars prior to apical surgery. The apical extent and homogeneity of the root canal fillings (RCF) as well as the number of root canals were examined.