90 resultados para molar tooth
Resumo:
Indications for the most frequently used imaging modalities in implant dentistry are proposed based on clinical need and biologic risk for the patient. To calculate the biologic risk, the authors carried out dose measurements. They demonstrated that the risk from a periapical radiograph is 20% of that from a panoramic radiograph. A panoramic radiograph and a series of 4 conventional tomographs of a single-tooth gap in the molar region carry 5% and 13% of the risk from computed tomography of the maxilla, respectively. Panoramic radiography is considered the standard radiographic examination for treatment planning of implant patients, because it imparts a low dose while giving the best radiographic survey. Periapical radiographs are used to elucidate details or to complete the findings obtained from the panoramic radiograph. Other radiographic methods, such as conventional film tomography or computed tomography, are applied only in special circumstances, film tomography being preferred for smaller regions of interest and computed tomography being justified for the complete maxilla or mandible when methods for dose reduction are followed. During follow-up, intraoral radiography is considered the standard radiographic examination, particularly for implants in the anterior region of the maxilla or for scientific studies. In patients requiring more than 5 periapical images, panoramic radiography is preferred.
Resumo:
Radiation dose delivered from the SCANORA radiography unit during the cross-sectional mode for dentotangential projections was determined. With regard to oral implantology, patient situations of an edentulous maxilla and mandible as well as a single tooth gap in regions 16 and 46 were simulated. Radiation doses were measured between 0.2 and 22.5 mGy to organs and tissues in the head and neck region when the complete maxilla or mandible was examined. When examining a single tooth gap, only 8% to 40% of that radiation dose was generally observed. Based on these results, the mortality risk was estimated according to a calculation model recommended by the Committee on the Biological Effects of Ionizing Radiations. The mortality risk ranged from 31.4 x 10(-6) for 20-year-old men to 4.8 x 10(-6) for 65-year-old women when cross-sectional imaging of the complete maxilla was performed. The values decreased by 70% when a single tooth gap in the molar region of the maxilla was radiographed. The figures for the mortality risk for examinations of the complete mandible were similar to those for the complete maxilla, but the mortality risk decreased by 80% if only a single tooth gap in the molar region of the mandible was examined. Calculations according to the International Commission on Radiological Protection carried out for comparison did not reveal the decrease of the mortality risk with age and resulted in a higher risk value in comparison to the group of 35-year old individuals in calculations according to the Committee on the Biological Effects of Ionizing Radiations.
Resumo:
Early implant placement is one treatment option for implant therapy following single-tooth extraction in the anterior maxilla. The surgical technique presented here is characterized by tooth extraction without flap elevation, a 4- to 8-week soft tissue healing period, implant placement in a correct three-dimensional position, simultaneous contour augmentation on the facial aspect with guided bone regeneration using a bioabsorbable collagen membrane combined with autogenous bone chips and a low-substitution bone filler, and tension-free primary wound closure. The surgical step-by-step procedure is presented with a case report. In addition, the biologic rationale is discussed.
Resumo:
BACKGROUND: The concept of early implant placement is a treatment option in postextraction sites of single teeth in the anterior maxilla. Implant placement is performed after a soft tissue healing period of 4 to 8 weeks. Implant placement in a correct three-dimensional position is combined with a simultaneous guided bone regeneration procedure to rebuild esthetic facial hard and soft tissue contours. METHODS: In this retrospective, cross-sectional study, 45 patients with an implant-borne single crown in function for 2 to 4 years were recalled for examination. Clinical and radiologic parameters, routinely used in implant studies, were assessed. RESULTS: All 45 implants were clinically successful according to strict success criteria. The implants demonstrated ankylotic stability without signs of a peri-implant infection. The peri-implant soft tissues were clinically healthy as indicated by low mean plaque (0.42) and sulcus bleeding index (0.51) values. None of the implants revealed a mucosal recession on the facial aspect as confirmed by a clearly submucosal position of all implant shoulders. The mean distance from the mucosal margin to the implant shoulder was -1.93 mm on the facial aspect. The periapical radiographs showed stable peri-implant bone levels, with a mean distance between the implant shoulder and the first bone-implant contact of 2.18 mm. CONCLUSIONS: This retrospective study demonstrated successful treatment outcomes for all 45 implants examined. The mid-term follow-up of 2 to 4 years also showed that the risk for mucosal recession was low with this treatment concept. Prospective clinical studies are required to confirm these encouraging results.
Resumo:
The estimation of possible intra- and postoperative complications for surgical removal of third molars in the mandible poses a frequent dilemma in oral surgery. In the present study, the influence of the patient's age and gender, a reduced mouth opening, and the anatomical position of the tooth in the mandible on intra- and postoperative complications were evaluated. In a total of 120 surgically removed third molars, 9.2% intraoperative complications occurred, mainly bleeding. Factors influencing the risk for intraoperative complications were a male patient, a reduced mouth opening, and distally angulated teeth. Postoperative complications were encountered in 6.7%, mainly dry sockets. For this group, a female gender, a higher age, and distally angulated teeth were identified as risk parameters. As most of the patient- and anatomy-related factors are set parameters when evaluating possible risk factors for third molar surgery, only the timepoint of surgery can be influenced by the surgeon. Regarding the increase in intra- and postoperative complications for third molar removal in higher age groups, the prophylactic third molar surgery between the age of 18 and 25 seems justified.
Resumo:
BACKGROUND: Limited evidence exists on the significance of residual probing pocket depth (PPD) as a predictive parameter for periodontal disease progression and tooth loss. AIM: The aim of this study was to investigate the influence of residual PPD >or=5 mm and bleeding on probing (BOP) after active periodontal therapy (APT) on the progression of periodontitis and tooth loss. MATERIAL AND METHODS: In this retrospective cohort, 172 patients were examined after APT and supportive periodontal therapy (SPT) for 3-27 years (mean 11.3 years). Analyses were conducted using information at site, tooth and patient levels. The association of risk factors with tooth loss and progression of periodontitis was investigated using multilevel logistic regression analysis. RESULTS: The number of residual PPD increased during SPT. Compared with PPD
Resumo:
Background: The goal of this study was to determine whether site-specific differences in the subgingival microbiota could be detected by the checkerboard method in subjects with periodontitis. Methods: Subjects with at least six periodontal pockets with a probing depth (PD) between 5 and 7 mm were enrolled in the study. Subgingival plaque samples were collected with sterile curets by a single-stroke procedure at six selected periodontal sites from 161 subjects (966 subgingival sites). Subgingival bacterial samples were assayed with the checkerboard DNA-DNA hybridization method identifying 37 species. Results: Probing depths of 5, 6, and 7 mm were found at 50% (n = 483), 34% (n = 328), and 16% (n = 155) of sites, respectively. Statistical analysis failed to demonstrate differences in the sum of bacterial counts by tooth type (P = 0.18) or specific location of the sample (P = 0.78). With the exceptions of Campylobacter gracilis (P <0.001) and Actinomyces naeslundii (P <0.001), analysis by general linear model multivariate regression failed to identify subject or sample location factors as explanatory to microbiologic results. A trend of difference in bacterial load by tooth type was found for Prevotella nigrescens (P <0.01). At a cutoff level of >/=1.0 x 10(5), Porphyromonas gingivalis and Tannerella forsythia (previously T. forsythensis) were present at 48.0% to 56.3% and 46.0% to 51.2% of sampled sites, respectively. Conclusions: Given the similarities in the clinical evidence of periodontitis, the presence and levels of 37 species commonly studied in periodontitis are similar, with no differences between molar, premolar, and incisor/cuspid subgingival sites. This may facilitate microbiologic sampling strategies in subjects during periodontal therapy.
Resumo:
AIM: To assess the clinical and radiographic outcomes of immediate transmucosal placement of implants into molar extraction sockets. STUDY DESIGN: Twelve-month multicenter prospective cohort study. MATERIAL AND METHODS: Following molar extraction, tapered implants with an endosseous diameter of 4.8 mm and a shoulder diameter of 6.5 mm were immediately placed into the sockets. Molars with evidence of acute periapical pathology were excluded. After implant placement and achievement of primary stability, flaps were repositioned and sutured allowing a non-submerged, transmucosal healing. Peri-implant marginal defects were treated according to the principles of guided bone regeneration (GBR) by means of deproteinized bovine bone mineral particles in conjunction with a bioresrobable collagen membrane. Standardized radiographs were obtained at baseline and 12 months thereafter. Changes in depth and width of the distance from the implant shoulder (IS) and from the alveolar crest (AC) to the bottom of the defect (BD) were assessed. RESULTS: Eighty-two patients (42 males and 40 females) were enrolled and followed for 12 months. They contributed with 82 tapered implants. Extraction sites displayed sufficient residual bone volume to allow primary stability of all implants. Sixty-four percent of the implants were placed in the areas of 36 and 46. GBR was used in conjunction with the placement of all implants. No post-surgical complications were observed. All implants healed uneventfully yielding a survival rate of 100% and healthy soft tissue conditions after 12 months. Radiographically, statistically significant changes (P<0.0001) in mesial and distal crestal bone levels were observed from baseline to the 12-month follow-up. CONCLUSIONS: The findings of this 12-month prospective cohort study showed that immediate transmucosal implant placement represented a predictable treatment option for the replacement of mandibular and maxillary molars lost due to reasons other than periodontitis including vertical root fractures, endodontic failures and caries.
Resumo:
To minimize the risk of intraoperative complications, a comprehensive radiological diagnostic work-up should be a routine procedure in oral surgery. This is especially true concerning possible damage to the inferior alveolar nerve during surgical removal of the third molars. The course and location of the nerve are best assessed when evaluating panoramic view images or cone beam CTs. The following case report demonstrates and discusses the importance of a thorough radiological evaluation before surgery, the problems raised by an interradicular course of the inferior alveolar nerve, and the finding of a monostotic fibrous dyplasia in the same patient.
Resumo:
BACKGROUND: Early implant placement is one of the treatment options in postextraction sites in the anterior maxilla. Implant placement is performed after a soft tissue healing period of 4 to 8 weeks. Implant placement is combined with a simultaneous guided bone regeneration (GBR) procedure to rebuild esthetic facial hard and soft tissue contours. METHODS: In this prospective case-series study, 20 consecutive patients treated with an implant-borne single crown were prospectively followed for 12 months. Clinical, radiologic, and esthetic parameters were recorded to assess treatment outcomes. RESULTS: At the 12-month examination, all 20 implants were successfully integrated, demonstrating ankylotic stability and healthy peri-implant soft tissues as documented by standard parameters. The esthetic outcomes assessed by a pink esthetic score (PES) and a white esthetic score (WES) demonstrated pleasing results overall. The WES values were slightly superior to the PES values. The periapical radiographs showed minimal crestal bone loss around the used bone level implants, with mean bone loss of 0.18 mm at 12 months. Only one implant showed >0.5 mm bone loss, combined with minor mucosal recession of 0.5 to 1.0 mm. CONCLUSIONS: This prospective case series study evaluating the concept of early implant placement demonstrated successful tissue integration for all 20 implants. The short-term follow-up of 12 months revealed pleasing esthetic outcomes overall, as assessed by objective parameters. The risk for mucosal recession was low; only one patient showed minor recession of the facial mucosa. These encouraging results need to be confirmed with 3- and 5-year follow-up examinations.
Resumo:
BACKGROUND: To validate the concept of early implant placement for use in the esthetically sensitive anterior maxilla, clinical trials should ideally include objective esthetic criteria when assessing outcome parameters. METHODS: In this cross-sectional, retrospective 2- to 4-year study involving 45 patients treated with maxillary anterior single-tooth implants according to the concept of early implant placement, a novel comprehensive index, comprising pink esthetic score and white esthetic score (PES/WES; the highest possible combined score is 20), was applied for the objective esthetic outcome assessment of anterior single-tooth implants. RESULTS: All 45 anterior maxillary single-tooth implants fulfilled strict success criteria for dental implants with regard to osseointegration, including the absence of peri-implant radiolucency, implant mobility, suppuration, and pain. The mean total PES/WES was 14.7 +/- 1.18 (range: 11 to 18). The mean total PES of 7.8 +/- 0.88 (range: 6 to 9) documents favorable overall peri-implant soft tissue conditions. The two PES variables facial mucosa curvature (1.9 +/- 0.29) and facial mucosa level (1.8 +/- 0.42) had the highest mean values, whereas the combination variable root convexity/soft tissue color and texture (1.2 +/- 0.53) proved to be the most difficult to fully satisfy. Mean scores were 1.6 +/- 0.5 for the mesial papilla and 1.3 +/- 0.5 for the distal papilla. A mean value of 6.9 +/- 1.47 (range: 4 to 10) was calculated for WES. CONCLUSIONS: This study demonstrated that anterior maxillary single-tooth replacement, according to the concept of early implant placement, is a successful and predictable treatment modality, in general, and from an esthetic point of view, in particular. The suitability of the PES/WES index for the objective outcome assessment of the esthetic dimension of anterior single-tooth implants was confirmed. However, prospective clinical trials are needed to further validate and refine this index.
Resumo:
PURPOSE: This systematic review sought to determine the long-term clinical survival rates of single-tooth restorations fabricated with computer-aided design/computer-assisted manufacture (CAD/CAM) technology, as well as the frequency of failures depending on the CAD/CAM system, the type of restoration, the selected material, and the luting agent. MATERIALS AND METHODS: An electronic search from 1985 to 2007 was performed using two databases: Medline/PubMed and Embase. Selected keywords and well-defined inclusion and exclusion criteria guided the search. All articles were first reviewed by title, then by abstract, and subsequently by a full text reading. Data were assessed and extracted by two independent examiners. The pooled results were statistically analyzed and the overall failure rate was calculated by assuming a Poisson-distributed number of events. In addition, reported failures were analyzed by CAD/CAM system, type of restoration, restorative material, and luting agent. RESULTS: From a total of 1,957 single-tooth restorations with a mean exposure time of 7.9 years and 170 failures, the failure rate was 1.75% per year, estimated per 100 restoration years (95% CI: 1.22% to 2.52%). The estimated total survival rate after 5 years of 91.6% (95% CI: 88.2% to 94.1%) was based on random-effects Poisson regression analysis. CONCLUSIONS: Long-term survival rates for CAD/CAM single-tooth Cerec 1, Cerec 2, and Celay restorations appear to be similar to conventional ones. No clinical studies or randomized clinical trials reporting on other CAD/CAM systems currently used in clinical practice and with follow-up reports of 3 or more years were found at the time of the search.
Resumo:
AIM: To assess dimensional ridge alterations following immediate implant placement in molar extraction sites. MATERIAL AND METHODS: Twelve subjects received 12 immediate transmucosal implants in molar extraction sites. Peri-implant defects were treated according to the principles of Guided Bone Regeneration by means of a deproteinized bone substitute and a bioresorbable collagen membrane. Changes in vertical (IS-BD, CREST-BD) and horizontal distances (EC-I, IC-I) of alveolar bony walls to the bottom of the defects (BD) and to the implant surfaces (I) were compared between implant placement and surgical re-entry at 6 months. RESULTS: The implant survival rate at 6 months was 100%. Statistically significant differences (P<0.01) were observed in the mean changes in vertical distances IS-BD and CREST-BD between baseline and re-entry. At re-entry, all peri-implant marginal defects assessed from the internal socket wall to the implant surface (IC-I) were healed. The residual combined thickness of the buccal wall with the newly formed peri-implant bone at sites with an initial thickness of 1 mm was statistically significantly smaller (P<0.05) compared with that of sites with an initial buccal thickness of 2 mm (2.50 +/- 0.76 vs. 4+/-0 mm). CONCLUSIONS: The marginal defects around immediate implants placed in molar extraction sites were completely filled after 6 months of healing through de novo bone formation. Bone resorption was observed from the external aspects of the buccal and oral socket walls. Dimensional changes of the external socket walls were mostly pronounced at the buccal aspects.
Resumo:
PURPOSE: This retrospective study reports the clinical outcome following placement of extraoral implants in severely resorbed posterior ridges to support distal-extension removable dentures. MATERIAL AND METHODS: Consecutively treated patients with partially or completely edentulous ridges, with available bone height in the posterior region of 6 mm or less, were included in the study. Implants originally intended for extraoral use (Straumann) were placed in second molar regions and allowed to heal for 4 to 6 months before abutment connection. At recall appointments, the peri-implant hard and soft tissues were evaluated. Complications with implant components, as well as mechanical and structural failures of the prostheses, were recorded. Two-year survival rates were calculated and life table analyses undertaken. RESULTS: Twenty-nine patients (19 women and 10 men; average age 61.2 years, range, 44 to 75 years) were included in the study. Forty-seven extraoral implants in 26 patients were placed in the second molar site of the mandible. Two extraoral implants in 2 patients failed during the osseointegration phase, yielding an 8-year cumulative success rate of 91.8%. The mean distance from the extraoral implants to the most distal tooth/implant was 28.1 mm (range, 16.7 to 39.2 mm). Twenty-three extraoral implants were restored with magnets, 18 with ball anchors, and 4 with conical cylinders. Replacement of abutments and retention elements was necessary in 2 patients. Four abutments in 2 patients were disconnected from the restorations. CONCLUSIONS: Within the limits of the employed research design, extraoral implants may be used successfully to provide support for distal-extension removable dentures in severely resorbed posterior alveolar ridges.
Resumo:
Purpose: The aim of this trial was to evaluate telescopic-retained prostheses on teeth and implants. Materials and Methods: Ten patients with a mean of 2.8 teeth received strategic implants to achieve triangular/quadrangular support. Survival and complication rates were estimated for telescopic abutments and prostheses. Results: After a mean observation period of > 2 years, no abutment was lost and all prostheses were in function. Complication rates were low, and maintenance services were limited to minor interventions. Conclusions: Combined tooth-implant-retained telescopic prostheses improve prosthetic support and offer successful function over a midterm period in patients with a severely reduced dentition.