353 resultados para coronary reperfusion


Relevância:

20.00% 20.00%

Publicador:

Resumo:

As the population ages, recurrent ventricular tachycardia (VT) is increasingly encountered in elderly patients with ischemic heart disease. Radiofrequency catheter ablation is useful for reducing VT therapy in patients with an implantable defibrillator. The utility of radiofrequency catheter ablation in the elderly is not well defined.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The first generation of the bioresorbable everolimus drug-eluting vascular scaffold showed signs of shrinkage at 6 months, which largely contributed to late luminal loss. Nevertheless, late luminal loss was less than that observed with bare metal stents. To maintain the mechanical integrity of the device up to 6 months, the scaffold design and manufacturing process of its polymer were modified.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to assess the differences in terms of curvature and angulation of the treated vessel after the deployment of either a metallic stent or a polymeric scaffold device.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Implantation of a coronary stent results in a mechanical enlargement of the coronary lumen with stretching of the surrounding atherosclerotic plaque. Using intravascular ultrasound virtual-histology (IVUS-VH) we examined the temporal changes in composition of the plaque behind the struts (PBS) following the implantation of the everolimus eluting bioresorbable vascular scaffold (BVS). Using IVUS-VH and dedicated software, the composition of plaque was analyzed in all patients from the ABSORB B trial who were imaged with a commercially available IVUS-VH console (s5i system, Volcano Corporation, Rancho Cordova, CA, USA) post-treatment and at 6-month follow-up. This dedicated software enabled analysis of the PBS after subtraction of the VH signal generated by the struts. The presence of necrotic core (NC) in contact with the lumen was also evaluated at baseline and follow-up. IVUS-VH data, recorded with s5i system, were available at baseline and 6-month follow-up in 15 patients and demonstrated an increase in both the area of PBS (2.45 ± 1.93 mm(2) vs. 3.19 ± 2.48 mm(2), P = 0.005) and the external elastic membrane area (13.76 ± 4.07 mm(2) vs. 14.76 ± 4.56 mm(2), P = 0.006). Compared to baseline there was a significant progression in the NC (0.85 ± 0.70 mm(2) vs. 1.21 ± 0.92 mm(2), P = 0.010) and fibrous tissue area (0.88 ± 0.79 mm(2) vs. 1.15 ± 1.05 mm(2), P = 0.027) of the PBS. The NC in contact with the lumen in the treated segment did not increase with follow-up (7.33 vs. 6.36%, P = 0.2). Serial IVUS-VH analysis of BVS-treated lesions at 6-month demonstrated a progression in the NC and fibrous tissue content of PBS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Novolimus, a macrocyclic lactone with anti-proliferative properties, has a similar efficacy to currently available agents; however it requires a lower dose, and less polymer, and is therefore conceivably safer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

New-generation coronary stents that release zotarolimus or everolimus have been shown to reduce the risk of restenosis. However, it is unclear whether there are differences in efficacy and safety between the two types of stents on the basis of prospectively adjudicated end points endorsed by the Food and Drug Administration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recurrence of cardiovascular events and mortality remain high after acute coronary syndromes. A Swiss multicentric study, "Inflammation and acute coronary syndromes (ACS)--Novel strategies for prevention and clinical managements", is currently underway with the support of the Swiss National Science Foundation. The study includes a clinical research subproject of which the aim is to assess the impact of the ELIPS program (multi-dimEnsionaL prevention Program after acute coronary Syndrome) on the recurrence of cardiovascular events after an ACS. The basic research sub-projects aim to investigate novel cardiovascular risk biomarkers and genetic determinants of recurrence and to study the role of stem cells after an ACS. Another sub-project will evaluate intracoronary imaging techniques and the efficacy of different types of stents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coronary artery disease remains the leading cause of mortality in most industrialized countries, although age-standardized mortality related to coronary artery disease (CAD) has decreased by more than 40% during the last two decades. Coronary atherosclerosis may cause angina pectoris, myocardial infarction, heart failure, arrhythmia, and sudden death. Medical management of atherosclerosis and its manifestation aims at retardation of progression of plaque formation, prevention of plaque rupture, and subsequent events and treatment of symptoms, when these occur as well as treatment of the sequelae of the disease. Revascularization by either percutaneous coronary intervention (PCI) or coronary artery bypass surgery (CABG) is performed as treatment of flow-limiting coronary stenosis to reduce myocardial ischaemia. In high-risk patients with acute coronary syndromes (ACS), a routine invasive strategy with revascularization in most patients provides the best outcome with a significant reduction in death and myocardial infarction compared with an initial conservative strategy. Conversely, the benefit of revascularization among patients with chronic stable CAD has been called into question. This review will provide information that revascularization exerts favourable effects on symptoms, quality of life, exercise capacity, and survival, particularly in those with extensive CAD and documented moderate-to-severe ischaemia. Accordingly, CABG and PCI should be considered a valuable adjunct rather than an alternative to medical therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Misclassification of the electrocardiogram (ECG) contributes to treatment errors in patients with acute coronary syndrome. We hypothesized that cardiology ECG review could reduce these errors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cardiogoniometry (CGM), a spatiotemporal electrocardiologic 5-lead method with automated analysis, may be useful in primary healthcare for detecting coronary artery disease (CAD) at rest. Our aim was to systematically develop a stenosis-specific parameter set for global CAD detection. In 793 consecutively admitted patients with presumed non-acute CAD, CGM data were collected prior to elective coronary angiography and analyzed retrospectively. 658 patients fulfilled the inclusion criteria, 405 had CAD verified by coronary angiography; the 253 patients with normal coronary angiograms served as the non-CAD controls. Study patients--matched for age, BMI, and gender--were angiographically assigned to 8 stenosis-specific CAD categories or to the controls. One CGM parameter possessing significance (P < .05) and the best diagnostic accuracy was matched to one CAD category. The area under the ROC curve was .80 (global CAD versus controls). A set containing 8 stenosis-specific CGM parameters described variability of R vectors and R-T angles, spatial position and potential distribution of R/T vectors, and ST/T segment alterations. Our parameter set systematically combines CAD categories into an algorithm that detects CAD globally. Prospective validation in clinical studies is ongoing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coronary late stent thrombosis, a rare but devastating complication, remains an important concern in particular with the increasing use of drug-eluting stents. Notably, pathological studies have indicated that the proportion of uncovered coronary stent struts represents the best morphometric predictor of late stent thrombosis. Intracoronary optical frequency domain imaging (OFDI), a novel second-generation optical coherence tomography (OCT)-derived imaging method, may allow rapid imaging for the detection of coronary stent strut coverage with a markedly higher precision when compared with intravascular ultrasound, due to a microscopic resolution (axial approximately 10-20 microm), and at a substantially increased speed of image acquisition when compared with first-generation time-domain OCT. However, a histological validation of coronary OFDI for the evaluation of stent strut coverage in vivo is urgently needed. Hence, the present study was designed to evaluate the capacity of coronary OFDI by electron (SEM) and light microscopy (LM) analysis to detect and evaluate stent strut coverage in a porcine model.