107 resultados para blood pressure measurement


Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: We determined and compared urethral pressure measurements using air charged and microtip catheters in a prospective, single-blind, randomized trial. MATERIALS AND METHODS: A consecutive series of 64 women referred for urodynamic investigation underwent sequential urethral pressure measurements using an air charged and a microtip catheter in randomized order. Patients were blinded to the type and sequence of catheter used. Agreement between the 2 catheter systems was assessed using the Bland and Altman 95% limits of agreement method. RESULTS: Intraclass correlation coefficients of air charged and microtip catheters for maximum urethral closure pressure at rest were 0.97 and 0.93, and for functional profile length they were 0.9 and 0.78, respectively. Pearson's correlation coefficients and Lin's concordance coefficients of air charged and microtip catheters were r = 0.82 and rho = 0.79 for maximum urethral closure pressure at rest, and r = 0.73 and rho = 0.7 for functional profile length, respectively. When applying the Bland and Altman method, air charged catheters gave higher readings than microtip catheters for maximum urethral closure pressure at rest (mean difference 7.5 cm H(2)O) and functional profile length (mean difference 1.8 mm). There were wide 95% limits of agreement for differences in maximum urethral closure pressure at rest (-24.1 to 39 cm H(2)O) and functional profile length (-7.7 to 11.3 mm). CONCLUSIONS: For urethral pressure measurement the air charged catheter is at least as reliable as the microtip catheter and it generally gives higher readings. However, air charged and microtip catheters cannot be used interchangeably for clinical purposes because of insufficient agreement. Hence, clinicians should be aware that air charged and microtip catheters may yield completely different results, and these differences should be acknowledged during clinical decision making.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Transient elevation of arterial blood pressure (BP) is frequent in acute ischemic stroke and may help to increase perfusion of tissue jeopardized by ischemia. If this is true, recanalization may eliminate the need for this BP elevation. METHODS: We analyzed BP in 149 patients with acute ischemic stroke on admission to the hospital and 1 and 12 hours after intraarterial thrombolysis. BP values of patients with adequate recanalization were compared with BP values of patients with inadequate recanalization. Recanalization was determined on cerebral arteriography after thrombolysis using thrombolysis in myocardial infarction grades. RESULTS: Systolic, mean, and diastolic arterial BP decreased significantly from admission to 12 hours after thrombolysis in all patients (P<0.001). Before thrombolysis, patients with adequate and inadequate recanalization showed equal systolic (147.4 and 148.0 mm Hg), mean (102.1 and 104.1 mm Hg), and diastolic (79.5 and 82.1 mm Hg) BP values. Twelve hours after thrombolysis, patients with adequate recanalization had lower values than those with inadequate recanalization (systolic BP, 130 versus 139.9 mm Hg; mean BP, 86.8 versus 92.2 mm Hg; and diastolic, BP 65.2 versus 68.3 mm Hg). Two-way repeated ANOVA analysis showed a significant group x time interaction for systolic BP, indicating a larger systolic BP decrease when recanalization succeeded (P=0.019). CONCLUSIONS: The course of elevated systolic but not diastolic BP after acute ischemic stroke was found to be inversely associated with the degree of vessel recanalization. When recanalization failed, systolic BP remained elevated longer than when it succeeded.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the association between arterial blood pressure (ABP) during the first 24 h and mortality in sepsis. DESIGN: Retrospective cohort study. SETTING: Multidisciplinary intensive care unit (ICU). PATIENTS AND PARTICIPANTS: A total of 274 septic patients. INTERVENTIONS: None. MEASUREMENTS AND RESULTS: Hemodynamic, and laboratory parameters were extracted from a PDMS database. The hourly time integral of ABP drops below clinically relevant systolic arterial pressure (SAP), mean arterial pressure (MAP), and mean perfusion pressure (MPP = MAP - central venous pressure) levels was calculated for the first 24 h after ICU admission and compared with 28-day-mortality. Binary and linear regression models (adjusted for SAPS II as a measure of disease severity), and a receiver operating characteristic (ROC) analysis were applied. The areas under the ROC curve were largest for the hourly time integrals of ABP drops below MAP 60 mmHg (0.779 vs. 0.764 for ABP drops below MAP 55 mmHg; P < or = 0.01) and MPP 45 mmHg. No association between the hourly time integrals of ABP drops below certain SAP levels and mortality was detected. One or more episodes of MAP < 60 mmHg increased the risk of death by 2.96 (CI 95%, 1.06-10.36, P = 0.04). The area under the ROC curve to predict the need for renal replacement therapy was highest for the hourly time integral of ABP drops below MAP 75 mmHg. CONCLUSIONS: A MAP level > or = 60 mmHg may be as safe as higher MAP levels during the first 24 h of ICU therapy in septic patients. A higher MAP may be required to maintain kidney function.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: It is unclear to which level mean arterial blood pressure (MAP) should be increased during septic shock in order to improve outcome. In this study we investigated the association between MAP values of 70 mmHg or higher, vasopressor load, 28-day mortality and disease-related events in septic shock. METHODS: This is a post hoc analysis of data of the control group of a multicenter trial and includes 290 septic shock patients in whom a mean MAP > or = 70 mmHg could be maintained during shock. Demographic and clinical data, MAP, vasopressor requirements during the shock period, disease-related events and 28-day mortality were documented. Logistic regression models adjusted for the geographic region of the study center, age, presence of chronic arterial hypertension, simplified acute physiology score (SAPS) II and the mean vasopressor load during the shock period was calculated to investigate the association between MAP or MAP quartiles > or = 70 mmHg and mortality or the frequency and occurrence of disease-related events. RESULTS: There was no association between MAP or MAP quartiles and mortality or the occurrence of disease-related events. These associations were not influenced by age or pre-existent arterial hypertension (all P > 0.05). The mean vasopressor load was associated with mortality (relative risk (RR), 1.83; confidence interval (CI) 95%, 1.4-2.38; P < 0.001), the number of disease-related events (P < 0.001) and the occurrence of acute circulatory failure (RR, 1.64; CI 95%, 1.28-2.11; P < 0.001), metabolic acidosis (RR, 1.79; CI 95%, 1.38-2.32; P < 0.001), renal failure (RR, 1.49; CI 95%, 1.17-1.89; P = 0.001) and thrombocytopenia (RR, 1.33; CI 95%, 1.06-1.68; P = 0.01). CONCLUSIONS: MAP levels of 70 mmHg or higher do not appear to be associated with improved survival in septic shock. Elevating MAP >70 mmHg by augmenting vasopressor dosages may increase mortality. Future trials are needed to identify the lowest acceptable MAP level to ensure tissue perfusion and avoid unnecessary high catecholamine infusions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We examined the magnitude of 20-min moderate exercise-induced platelet activation in 50 volunteers with normal (n=31) or elevated blood pressure (EBP; n=19). Blood was drawn before, immediately after, and 25 min after exercise. Antibody-staining for platelet activation markers, P-selectin, and fibrinogen receptors was done with and without adenosine diphosphate (ADP) stimulation in whole blood for flow cytometric analyses. Exercise led to increases in percent aggregated platelets and percent platelets expressing P-selectin or PAC-1 binding (ps< or =.001). This increase in percent platelets expressing P-selectin continued even after a 25-min rest only in the EBP group (p< or =.01) accompanied by an increase in percent of aggregated platelets (p< or =.05). Although ADP stimulation led to increased platelet activation at rest, it was attenuated following exercise, even among EBP individuals. A moderate exercise challenge induced prolonged platelet activation in individuals with EBP but attenuation in activation to further stimulation by an agonist. Findings suggest that a recovery period after physical stress appears critical in individuals with high BP regarding platelet activation and aggregation, which can lead to an acute coronary syndrome in vulnerable individuals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION Low systolic blood pressure (SBP) is an important secondary insult following traumatic brain injury (TBI), but its exact relationship with outcome is not well characterised. Although a SBP of <90mmHg represents the threshold for hypotension in consensus TBI treatment guidelines, recent studies suggest redefining hypotension at higher levels. This study therefore aimed to fully characterise the association between admission SBP and mortality to further inform resuscitation endpoints. METHODS We conducted a multicentre cohort study using data from the largest European trauma registry. Consecutive adult patients with AIS head scores >2 admitted directly to specialist neuroscience centres between 2005 and July 2012 were studied. Multilevel logistic regression models were developed to examine the association between admission SBP and 30 day inpatient mortality. Models were adjusted for confounders including age, severity of injury, and to account for differential quality of hospital care. RESULTS 5057 patients were included in complete case analyses. Admission SBP demonstrated a smooth u-shaped association with outcome in a bivariate analysis, with increasing mortality at both lower and higher values, and no evidence of any threshold effect. Adjusting for confounding slightly attenuated the association between mortality and SBP at levels <120mmHg, and abolished the relationship for higher SBP values. Case-mix adjusted odds of death were 1.5 times greater at <120mmHg, doubled at <100mmHg, tripled at <90mmHg, and six times greater at SBP<70mmHg, p<0.01. CONCLUSIONS These findings indicate that TBI studies should model SBP as a continuous variable and may suggest that current TBI treatment guidelines, using a cut-off for hypotension at SBP<90mmHg, should be reconsidered.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was the evaluation of a predictive genetic marker for nephropathy and hypertension in patients with type-I-diabetes mellitus (IDDM). The study was performed on 247 pediatric patients with IDDM. The mean age was 15.5 years (range 3.1-29.3), the mean duration of diabetes was 7.6 years (range 0.1-25.7). Age-related blood pressure and nocturnal albumin excretion rate were compared with the insertion/deletion-(I/D) polymorphism of the angiotensin-I converting enzyme gene. The genotype distribution did not differ significantly between IDDM patients (ID 48%, D 28%, I 24%) and the control group (ID 44%, D 37%, I 19%). Neither in the entire group, nor in patients with IDDM for more than 5 years, was a correlation found bet-ween allele distribution and albumin excretion rate. No correlation was found between genotype and blood pressure. When patients with a chronological age above 12 years were analysed separately, the genotype distribution between the groups with normal and elevated blood pressure showed no significant difference. The previously reported association of the I/D-polymorphism with nephropathy could not be confirmed in this study. The development of microalbuminuria, nephropathy and hypertension will be followed in our pediatric patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ubiquitylation plays an important role in the control of Na⁺ homeostasis by the kidney. It is well established that the epithelial Na⁺ channel ENaC is regulated by the ubiquitin-protein ligase NEDD4-2, limiting ENaC cell surface expression and activity. Ubiquitylation can be reversed by the action of deubiquitylating enzymes (DUBs). One such DUB, USP2-45, was identified previously as an aldosterone-induced protein in the kidney and is also a circadian output gene. In heterologous expression systems, USP2-45 binds to ENaC, deubiquitylates it, and enhances channel density and activity at the cell surface. Because the role of USP2-45 in renal Na⁺ transport had not been studied in vivo, we investigated here the effect of Usp2 gene inactivation in this process. We demonstrate first that USP2-45 protein has a rhythmic expression with a peak at ZT12. Usp2-KO mice did not show any differences from wild-type littermates with respect to the diurnal control of Na⁺ or K⁺ urinary excretion and plasma levels either on a standard diet or after acute and chronic changes to low- and high-Na⁺ diets, respectively. Moreover, they had similar aldosterone levels on either a low- or high-Na⁺ diet. Blood pressure measurements using telemetry did not reveal variations compared with control mice. Usp2-KO mice did not display alterations in expression of genes involved in sodium homeostasis or the ubiquitin system, as evidenced by transcriptome analysis in the kidney. Our data suggest that USP2 does not play a primary role in the control of Na⁺ balance or blood pressure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Body weight (BW) and blood pressure (BP) have a close relationship, which has been accounted for by hormonal changes. No previous study has evaluated the effect of wearing an external weight vest on BP to determine whether there is a simple mechanism between BW and BP. Seventeen healthy volunteers underwent weight reduction (WR) through caloric restriction. Before and after WR, BW, body fat percentage and BP at rest and during exercise were measured. Before and after WR, exercise testing was performed twice with the random allocation of a weight vest (10 kg) during one of the tests. Linear regression was used to detect independent associations between BP and the weight vest, BW and body fat percentage. BW decreased from 89.4 ± 15.4 kg to 79.1 ± 14.0 kg following WR (P<0.001). WR led to significant decreases in BP at rest (from 130.0/85.9 mm Hg to 112.5/77.8 mm Hg, P<0.001 for systolic and diastolic BPs) and during exercise. The weight vest significantly increased BP at rest (to 136.1/90.7 mm Hg before and 125.8/84.6 mm Hg after WR) and during exercise. Linear regression analysis identified an independent association between the weight vest and BP (P=0.006 for systolic BP and P=0.009 for diastolic BP at rest). This study demonstrates that wearing an external weight vest has immediate effects on BP at rest and during exercise independent of BW or body fat. More research is needed to understand the physiological mechanisms between weight and BP.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The clinical demand for a device to monitor Blood Pressure (BP) in ambulatory scenarios with minimal use of inflation cuffs is increasing. Based on the so-called Pulse Wave Velocity (PWV) principle, this paper introduces and evaluates a novel concept of BP monitor that can be fully integrated within a chest sensor. After a preliminary calibration, the sensor provides non-occlusive beat-by-beat estimations of Mean Arterial Pressure (MAP) by measuring the Pulse Transit Time (PTT) of arterial pressure pulses travelling from the ascending aorta towards the subcutaneous vasculature of the chest. In a cohort of 15 healthy male subjects, a total of 462 simultaneous readings consisting of reference MAP and chest PTT were acquired. Each subject was recorded at three different days: D, D+3 and D+14. Overall, the implemented protocol induced MAP values to range from 80 ± 6 mmHg in baseline, to 107 ± 9 mmHg during isometric handgrip maneuvers. Agreement between reference and chest-sensor MAP values was tested by using intraclass correlation coefficient (ICC = 0.78) and Bland-Altman analysis (mean error = 0.7 mmHg, standard deviation = 5.1 mmHg). The cumulative percentage of MAP values provided by the chest sensor falling within a range of ±5 mmHg compared to reference MAP readings was of 70%, within ±10 mmHg was of 91%, and within ±15mmHg was of 98%. These results point at the fact that the chest sensor complies with the British Hypertension Society (BHS) requirements of Grade A BP monitors, when applied to MAP readings. Grade A performance was maintained even two weeks after having performed the initial subject-dependent calibration. In conclusion, this paper introduces a sensor and a calibration strategy to perform MAP measurements at the chest. The encouraging performance of the presented technique paves the way towards an ambulatory-compliant, continuous and non-occlusive BP monitoring system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND It is often assumed that blood pressure increases acutely after major stroke, resulting in so-called post-stroke hypertension. In view of evidence that the risks and benefits of blood pressure-lowering treatment in acute stroke might differ between patients with major ischaemic stroke and those with primary intracerebral haemorrhage, we compared acute-phase and premorbid blood pressure levels in these two disorders. METHODS In a population-based study in Oxfordshire, UK, we recruited all patients presenting with stroke between April 1, 2002, and March 31, 2012. We compared all acute-phase post-event blood pressure readings with premorbid readings from 10-year primary care records in all patients with acute major ischaemic stroke (National Institutes of Health Stroke Scale >3) versus those with acute intracerebral haemorrhage. FINDINGS Of 653 consecutive eligible patients, premorbid and acute-phase blood pressure readings were available for 636 (97%) individuals. Premorbid blood pressure (total readings 13,244) had been measured on a median of 17 separate occasions per patient (IQR 8-31). In patients with ischaemic stroke, the first acute-phase systolic blood pressure was much lower than after intracerebral haemorrhage (158·5 mm Hg [SD 30·1] vs 189·8 mm Hg [38·5], p<0·0001; for patients not on antihypertensive treatment 159·2 mm Hg [27·8] vs 193·4 mm Hg [37·4], p<0·0001), was little higher than premorbid levels (increase of 10·6 mm Hg vs 10-year mean premorbid level), and decreased only slightly during the first 24 h (mean decrease from <90 min to 24 h 13·6 mm Hg). By contrast with findings in ischaemic stroke, the mean first systolic blood pressure after intracerebral haemorrhage was substantially higher than premorbid levels (mean increase of 40·7 mm Hg, p<0·0001) and fell substantially in the first 24 h (mean decrease of 41·1 mm Hg; p=0·0007 for difference from decrease in ischaemic stroke). Mean systolic blood pressure also increased steeply in the days and weeks before intracerebral haemorrhage (regression p<0·0001) but not before ischaemic stroke. Consequently, the first acute-phase blood pressure reading after primary intracerebral haemorrhage was more likely than after ischaemic stroke to be the highest ever recorded (OR 3·4, 95% CI 2·3-5·2, p<0·0001). In patients with intracerebral haemorrhage seen within 90 min, the highest systolic blood pressure within 3 h of onset was 50 mm Hg higher, on average, than the maximum premorbid level whereas that after ischaemic stroke was 5·2 mm Hg lower (p<0·0001). INTERPRETATION Our findings suggest that systolic blood pressure is substantially raised compared with usual premorbid levels after intracerebral haemorrhage, whereas acute-phase systolic blood pressure after major ischaemic stroke is much closer to the accustomed long-term premorbid level, providing a potential explanation for why the risks and benefits of lowering blood pressure acutely after stroke might be expected to differ. FUNDING Wellcome Trust, Wolfson Foundation, UK Medical Research Council, Stroke Association, British Heart Foundation, National Institute for Health Research.