118 resultados para balloon catheter


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Current concepts of catheter ablation for atrial fibrillation (AF) commonly use three-dimensional (3D) reconstructions of the left atrium (LA) for orientation, catheter navigation, and ablation line placement. OBJECTIVES: The purpose of this study was to compare the 3D electroanatomic reconstruction (Carto) of the LA, pulmonary veins (PVs), and esophagus with the true anatomy displayed on multislice computed tomography (CT). METHODS: In this prospective study, 100 patients undergoing AF catheter ablation underwent contrast-enhanced spiral CT scan with barium swallow and subsequent multiplanar and 3D reconstructions. Using Carto, circumferential plus linear LA lesions were placed. The esophagus was tagged and integrated into the Carto map. RESULTS: Compared with the true anatomy on CT, the electroanatomic reconstruction accurately displayed the true distance between the lower PVs; the distances between left upper PV, left lower PV, right lower PV, and center of the esophagus; the longitudinal diameter of the encircling line around the funnel of the left PVs; and the length of the mitral isthmus line. Only the distances between the upper PVs, the distance between the right upper PV and esophagus, and the diameter of the right encircling line were significantly shorter on the electroanatomic reconstructions. Furthermore, electroanatomic tagging of the esophagus reliably visualized the true anatomic relationship to the LA. On multiple tagging and repeated CT scans, the LA and esophagus showed a stable anatomic relationship, without relevant sideward shifting of the esophagus. CONCLUSION: Electroanatomic reconstruction can display with high accuracy the true 3D anatomy of the LA and PVs in most of the regions of interest for AF catheter ablation. In addition, Carto was able to visualize the true anatomic relationship between the esophagus and LA. Both structures showed a stable anatomic relationship on Carto and CT without relevant sideward shifting of the esophagus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

After 75 years of invasive and over 50 years of interventional cardiology, cardiac catheter-based procedures have become the most frequently used interventions of modern medicine. Patients undergoing a percutaneous coronary intervention (PCI) outnumber those with coronary artery bypass surgery by a factor of 2 to 4. The default approach to PCI is the implantation of a (drug-eluting) stent, in spite of the fact that it improves the results of balloon angioplasty only in about 25% of cases. The dominance of stenting over conservative therapy or balloon angioplasty on one hand and bypass surgery on the other hand is a flagrant example of how medical research is digested an applied in real life. Apart from electrophysiological interventions, closure ot the patent foramen ovale and percutaneous replacement of the aortic valve in the elderly have the potential of becoming daily routine procedures in catheterization laboratories around the world. Stem cell regeneration of vessels or heart muscle, on the other hand, may remain a dream never to come true.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Central venous catheters are established as vascular access in hemodialysis therapy. Vascular catheter misdirection may occur and is a well known problem. We present a rare catheter malposition in a young dialysis patient with consequent dilatation of the azygos vein system, simulating the appearance of an azygos continuation syndrome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Triple A syndrome is a rare autosomal recessive inherited disorder which is characterized by alacrima, adrenal insufficiency, and achalasia. We report on a 14-year old girl with dysphagia, regurgitation, and vomiting since 5 years. At the age of five years an Addison crisis was diagnosed and cortisone substitution was initiated. In addition, the patient had episodes of conjunctivitis. Severe esophagitis and candida infection were diagnosed by esophago-gastro-duodenoscopy and treated with omeprazole and fluconazole. The esophageal barium swallow was typical for achalasia. Medical treatment of achalasia with oral nifedipine resulted only in a partial and temporal improvement. But after seven balloon dilatations dysphagia and nocturnal coughing improved clearly and a remarkable gain of weight could be seen. Direct sequencing showed a homozygous nonsense mutation in exon 11 of the AAAS gene leading to truncation at position 342 of the 546 amino acid protein. CONCLUSION: Triple A syndrome has to be considered in patients with dysphagia. In our patient, the absence of tears since birth followed by adrenal insufficiency were early signs of the triple A syndrome. Balloon dilatation of the esophago-gastric junction is an effective treatment, which can avoid surgical interventions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Early catheter-related infection is a serious complication in cancer treatment, although risk factors for its occurrence are not well established. The authors conducted a prospective study to identify the risk factors for developing early catheter-related infection. METHODS: All consecutive patients with cancer who underwent insertion of a central venous catheter were enrolled and were followed prospectively during 1 month. The study endpoint was occurrence of early catheter-related infection. RESULTS: Over 10,392 catheter-days of follow-up, 14 of 371 patients had early catheter-related infections (14 patients in 10,392 catheter-days or 1.34 per 1000 catheter-days). The causative pathogens were gram positive in 11 of 14 patients. In univariate analysis, the risk factors for early catheter-related infection were aged <10 years (P = .0001), difficulties during insertion (P < 10(-6)), blood product administration (P < 10(-3)), parenteral nutrition (P < 10(-4)), and use >2 days (P < 10(-6)). In multivariate analysis, 3 variables remained significantly associated with the risk of early catheter-related infection: age <10 years (odds ratio [OR], 18.4; 95% confidence interval [95% CI], 1.9-106.7), difficulties during insertion procedure (OR, 25.6; 95% CI, 4.2-106), and parenteral nutrition (OR, 28.5; 95% CI, 4.2-200). CONCLUSIONS: On the day of insertion, 2 variables were identified that were associated with a high risk of developing an early catheter-related infection: young age and difficulties during insertion. The results from this study may be used to identify patients who are at high risk of infection who may be candidates for preventive strategies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: The purpose of the study was to compare efficacy and potential complications of 2 commercially available devices for mechanical thromboembolectomy. METHODS: Devices were tested in an established animal model allowing the use of routine angiography catheters and thrombectomy devices. Radio-opaque thrombi were used for visualization of thrombus-device interaction during angiography. The Merci Retrieval System and the Catch Thromboembolectomy System were assessed each in 10 vessel occlusions. For every occluded vessel up to 5 retrieval attempts were performed. RESULTS: Sufficient recanalization was achieved with the Merci Retriever in 90% of occlusions, and with the Catch device recanalization was achieved in 70% of occlusions. Recanalization at the first attempt occurred significantly more often with the Merci Retriever compared to the Catch device (OR, 21; 95% CI, 1.78-248.11). Consequently, significantly more attempts (P=0.02) had to be performed with the Catch device; therefore, time to recanalization was longer. Thrombus fragmentations during retrieval were caused more often by the Catch device compared to the Merci Retriever (OR, 15.6; 95% CI, 1.73-140.84), resulting in a higher distal embolization rate. During retrieval both devices lost thrombotic material at the tip of the guide catheter, which was then aspirated in most cases. CONCLUSIONS: Both distal devices are effective for thromboembolectomy. To avoid loss of thrombotic material and distal embolization, the use of large luminal balloon guide catheters and aspiration during retrieval seems to be mandatory. The design of the Merci Retriever appears to be more efficient during thrombus mobilization and retrieval with less fragmentation compared to the Catch Thromboembolectomy System.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: The use of vascular plug devices for the occlusion of high-flow lesions is a relatively new and successful procedure in peripheral and cardiopulmonary interventions. We report on the use and efficiency of the Amplatzer vascular plug in a small clinical series and discuss its potential for occlusion of large vessels and high-flow lesions in neurointerventions. METHODS: Between 2005 and 2007 four patients (mean age 38.5 years, range 16-62 years) were treated with the device, in three patients to achieve parent artery occlusion of the internal carotid artery, in one patient to occlude a high-flow arteriovenous fistula of the neck. The application, time to occlusion, and angiographic and clinical results and the follow-up were evaluated. RESULTS: Navigation, positioning and detachment of the device were satisfactory in all cases. No flow-related migration of the plug was seen. The cessation of flow was delayed by a mean of 10.5 min after deployment of the first device. In the procedures involving vessel sacrifice, two devices had to be deployed to achieve total occlusion. No patient experienced new neurological deficits; the 3-month follow-up revealed stable results. CONCLUSION: The Amplatzer vascular plug can be adapted for the treatment of high-flow lesions and parent artery occlusions in the head and neck. In this small series the use of the devices was uncomplicated and safe. The rigid and large delivery device and the delayed cessation of flow currently limit the device's use in neurointerventions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acute ischemic stroke is a major cause of morbidity and mortality in industrialized nations. The sequel of stroke ranges from mild to severe disability and even death. Since the impairment may be permanent, the costs to society from work incapacity and the need for long-term care can be high. Additionally, the burden of suffering associated with the disease may have devastating effects on individuals and families.Following the occlusion of a cerebral vessel, the full extent of the infarction may not become clinically and radiologically apparent until days after. By then, the surrounding watershed zone, or penumbra, either survives or succumbs to necrosis over time. The natural history of this "tissue at risk" is determined by two factors: the collateralization from other vascular territories and the possible occurrence of spontaneous recanalization of the occluded vessel. The current treatment options for acute ischemic stroke are aiming at an early and sustained restoration of flow to the penumbra. The effect of the treatment is therefore time-dependent and the neurologic outcome is a function of the time span between onset of symptoms and recanalization therapy as well as of the recanalization rate associated with a specific treatment.This report summarizes the results of the major trials on catheter-based interventions, either using thrombolytic drugs or novel mechanical approaches being developed to treat patients with acute ischemic stroke.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The technique of transseptal puncture for catheter ablation of atrial fibrillation after percutaneous closure of a foramen ovale with the Amplatzer Occluder is demonstrated based on 2 representative cases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To clarify the role of the pulmonary artery catheter in the intensive care unit. DATA SOURCES: Recent and relevant literature from MEDLINE and authors' personal databases. STUDY SELECTION: Studies on pulmonary artery catheter use and use of other monitoring devices in critically ill patients. DATA EXTRACTION: Based largely on clinical experience and assessment of the relevant published literature and in response to recent articles attacking the pulmonary artery catheter, we propose that the pulmonary artery catheter is still a valuable tool for the hemodynamic monitoring of patients with complex disease processes in whom the information obtained from the pulmonary artery catheter may influence management. We suggest that there is a need to revisit the basics of hemodynamic management and reassess the way in which the pulmonary artery catheter is used, applying three key principles: correct measurement, correct data interpretation, and correct application. CONCLUSION: The pulmonary artery catheter is still a valuable tool for hemodynamic monitoring when used in selected patients and by physicians adequately trained to correctly interpret and apply the data provided.