232 resultados para aorta valve regurgitation


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Transcatheter aortic valve replacement (TAVR) has been established as a less invasive alternative to open-heart surgery in inoperable or high-risk patients presenting with symptomatic severe aortic valve stenosis. The feasibility and efficacy of valve-in-valve implantation in degenerated surgical aortic bioprostheses have also been described and can currently be considered a valuable treatment option in patients deemed unsuitable for repeat cardiac surgery. However, the clinical use of TAVR devices is not limited to the treatment of the tricuspid stenotic aortic valve. Several additional indications including treatment of the bicuspid stenotic aortic valve, aortic regurgitation, and valve-in-valve or valve-in-ring implantation in the mitral or tricuspid position as well as treatment of pure mitral, tricuspid, or pulmonary regurgitation have been described. The purpose of the present review is to summarize the available evidence concerning the emerging off-label use of TAVR devices in current clinical practice. Case examples have been selected to highlight the main procedural steps of each particular intervention.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIMS Transcatheter mitral valve replacement (TMVR) is an emerging technology with the potential to treat patients with severe mitral regurgitation at excessive risk for surgical mitral valve surgery. Multimodal imaging of the mitral valvular complex and surrounding structures will be an important component for patient selection for TMVR. Our aim was to describe and evaluate a systematic multi-slice computed tomography (MSCT) image analysis methodology that provides measurements relevant for transcatheter mitral valve replacement. METHODS AND RESULTS A systematic step-by-step measurement methodology is described for structures of the mitral valvular complex including: the mitral valve annulus, left ventricle, left atrium, papillary muscles and left ventricular outflow tract. To evaluate reproducibility, two observers applied this methodology to a retrospective series of 49 cardiac MSCT scans in patients with heart failure and significant mitral regurgitation. For each of 25 geometrical metrics, we evaluated inter-observer difference and intra-class correlation. The inter-observer difference was below 10% and the intra-class correlation was above 0.81 for measurements of critical importance in the sizing of TMVR devices: the mitral valve annulus diameters, area, perimeter, the inter-trigone distance, and the aorto-mitral angle. CONCLUSIONS MSCT can provide measurements that are important for patient selection and sizing of TMVR devices. These measurements have excellent inter-observer reproducibility in patients with functional mitral regurgitation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The instantaneous three-dimensional velocity field past a bioprosthetic heart valve was measured using tomographic particle image velocimetry (PIV). Two digital cameras were used together with a mirror setup to record PIV images from four different angles. Measurements were conducted in a transparent silicone phantom with a simplified geometry of the aortic root. The refraction indices of the silicone phantom and the working fluid were matched to minimize optical distortion from the flow field to the cameras. The silicone phantom of the aorta was integrated in a flow loop driven by a piston pump. Measurements were conducted for steady and pulsatile flow conditions. Results of the instantaneous, ensemble and phase averaged flow field are presented. The three-dimensional velocity field reveals a flow topology, which can be related to features of the aortic valve prosthesis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The tricuspid valve is frequently affected in adults with congenital heart disease (CHD). Disease of this valve can occur primarily or develop secondary to changes in the right ventricle caused by other defects. Quantitative echocardiographic assessment of tricuspid regurgitation is essential to assess its cause and prognosis. Treatment options vary depending on the underlying defect and right ventricular function. Surgical management of tricuspid valve disease is complex and evolving.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Left ventricular hypertrophy (LVH) is due to pressure overload or mechanical stretch and is thought to be associated with remodeling of gap-junctions. We investigated whether the expression of connexin 43 (Cx43) is altered in humans in response to different degrees of LVH. The expression of Cx43 was analyzed by quantitative polymerase chain reaction, Western blot analysis and immunohistochemistry on left ventricular biopsies from patients undergoing aortic or mitral valve replacement. Three groups were analyzed: patients with aortic stenosis with severe LVH (n=9) versus only mild LVH (n=7), and patients with LVH caused by mitral regurgitation (n=5). Cx43 mRNA expression and protein expression were similar in the three groups studied. Furthermore, immunohistochemistry revealed no change in Cx43 distribution. We can conclude that when compared with mild LVH or with LVH due to volume overload, severe LVH due to chronic pressure overload is not accompanied by detectable changes of Cx43 expression or spatial distribution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of the present analysis was to identify predictors of procedural success of percutaneous transcatheter aortic valve implantation (TAVI).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors present the case of an 81-year-old patient with severe aortic stenosis who experienced left ventricular embolization of an aortic bioprosthesis during transapical aortic valve implantation. The authors discuss reasons for prosthesis embolization and reinforce the attention to technical details and the widespread use of multimodality imaging techniques. In this context, transesophageal echocardiography appears indispensable in the detection and management of procedure-related complications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Atrioventricular (AV) conduction impairment is well described after surgical aortic valve replacement, but little is known in patients undergoing transcatheter aortic valve implantation (TAVI). We assessed AV conduction and need for a permanent pacemaker in patients undergoing TAVI with the Medtronic CoreValve Revalving System (MCRS) or the Edwards Sapien Valve (ESV). Sixty-seven patients without pre-existing permanent pacemaker were included in the study. Forty-one patients (61%) and 26 patients (39%) underwent successful TAVI with the MCRS and ESV, respectively. Complete AV block occurred in 15 patients (22%), second-degree AV block in 4 (6%), and new left bundle branch block in 15 (22%), respectively. A permanent pacemaker was implanted in 23 patients (34%). Overall PR interval and QRS width increased significantly after the procedure (p <0.001 for the 2 comparisons). Implantation of the MCRS compared to the ESV resulted in a trend toward a higher rate of new left bundle branch block and complete AV block (29% vs 12%, p = 0.09 for the 2 comparisons). During follow-up, complete AV block resolved in 64% of patients. In multivariable regression analysis pre-existing right bundle branch block was the only independent predictor of complete AV block after TAVI (relative risk 7.3, 95% confidence interval 2.4 to 22.2). In conclusion, TAVI is associated with impairment of AV conduction in a considerable portion of patients, patients with pre-existing right bundle branch block are at increased risk of complete AV block, and complete AV block resolves over time in most patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Valvuloplasty of the aortic valve is currently used in selected patients for severe calcified aortic valve disease, but clinical effectiveness is low and complication rate remains high. In this study, the total particle load after valvuloplasty and the embolization risk of calcific debris into the coronary arteries was analyzed in an in vitro model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The conventional surgical aortic bioprostheses used for treatment of aortic stenosis (AS) are inherently stenotic in nature. The more favorable mechanical profile of the Medtronic CoreValve bioprosthesis may translate into a better hemodynamic and neurohormonal response.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 91-year-old female patient presented with worsening exertional dyspnea 1 month after transfemoral aortic valve implantation using an Edwards Sapien valve. She was found to have a paraprosthetic sinus of Valsalva rupture with a left-to-right shunt into the right ventricular cavity. The patient underwent coil closure of the defect with successful shunt elimination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aberrant origin of a pulmonary artery from the ascending aorta is an uncommon congenital vascular malformation with poor survival without surgery. In this case report, we describe the unusual late diagnosis of this congenital malformation in an otherwise asymptomatic young man presenting with mild hemoptysis. We review the natural and modified history of this defect and the relevant aspects of follow-up in adult life.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To date, transapical aortic valve implantation has required a balloon-expandable stented valve prosthesis. More recently, a novel self-expanding sutureless stented bovine pericardial prosthesis has been developed which allows rapid aortic valve replacement via an open transaortic approach in humans. The aim of this animal study was to develop a reliable protocol to facilitate the transapical implantation of this self-expanding valve in a porcine model.