92 resultados para aménagement durable


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this analysis was to assess the effect of body mass index (BMI) on 1-year outcomes in patients enrolled in a contemporary percutaneous coronary intervention trial comparing a sirolimus-eluting stent with a durable polymer to a biolimus-eluting stent with a biodegradable polymer. A total of 1,707 patients who underwent percutaneous coronary intervention were randomized to treatment with either biolimus-eluting stents (n = 857) or sirolimus-eluting stents (n = 850). Patients were assigned to 1 of 3 groups according to BMI: normal (<25 kg/m(2)), overweight (25 to 30 kg/m(2)), or obese (>30 kg/m(2)). At 1 year, the incidence of the composite of cardiac death, myocardial infarction, and clinically justified target vessel revascularization was assessed. In addition, rates of clinically justified target lesion revascularization and stent thrombosis were assessed. Cox proportional-hazards analysis, adjusted for clinical differences, was used to develop models for 1-year mortality. Forty-five percent of the patients (n = 770) were overweight, 26% (n = 434) were obese, and 29% (n = 497) had normal BMIs. At 1-year follow-up, the cumulative rate of cardiac death, myocardial infarction, and clinically justified target vessel revascularization was significantly higher in the obese group (8.7% in normal-weight, 11.3% in overweight, and 14.5% in obese patients, p = 0.01). BMI (hazard ratio 1.47, 95% confidence interval 1.02 to 2.14, p = 0.04) was an independent predictor of stent thrombosis. Stent type had no impact on the composite of cardiac death, myocardial infarction, and clinically justified target vessel revascularization at 1 year in the 3 BMI groups (hazard ratio 1.08, 95% confidence interval 0.63 to 1.83, p = 0.73). In conclusion, BMI was an independent predictor of major adverse cardiac events at 1-year clinical follow-up. The higher incidence of stent thrombosis in the obese group may suggest the need for a weight-adjusted dose of clopidogrel.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

First-generation drug-eluting stents (DES) with controlled release of sirolimus or paclitaxel from durable polymers compared with bare-metal stents have been consistently shown to reduce the risk of repeat revascularization procedures due to restenosis. The superior efficacy was found across a wide range of patients and lesion subsets and persisted up to 5 years whereas similar outcomes have been observed in terms of death and myocardial infarction. Newer generation DES have been developed with the goal to further improve upon the safety profile of first-generation DES while maintaining efficacy. These platforms include DES with improved and more biocompatible durable polymers, DES using bioabsorbable polymers for drug release, DES with polymer-free drug release, and fully bioabsorbable DES. Newer generation DES with durable polymers such as zotarolimus-eluting or everolimus-eluting XIENCE V stents have been directly compared with first-generation DES. Most recent results of large scale clinical trials are encouraging in terms of similar or increased efficacy while improving safety by reducing the rates of myocardial infarctions and stent thrombosis. DES using biodegradable polymers for drug release represent the next technological modification and preliminary results are favorable and demonstrate similar angiographic and clinical efficacy as first-generation DES, but only longer term follow-up and investigation in larger patient cohorts will determine whether their use is associated with improved long-term safety. Fully bioabsorbable stents represent another innovative approach. Whether this innovative concept will enter into clinical routine remains yet to be determined.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This publication is a collation and summary of the major achievements of the Agricultural Research Station of Cinzana (SRAC) and the Capacity Building for Sustainable Agriculture Project (PRECAD). Both projects, created in 1983 and 2006, respectively, have been developed through close collaboration between the Rural Economy Institute (IER) responsible for agricultural research in Mali and the Syngenta Foundation for Sustainable Agriculture (SFSA), formerly the Ciba-Geigy Foundation. The publication covers the period from 1979 to 2009 and includes, where available, some key information for the year 2010. It is aimed at a wide audience and provides an overview of the work carried out in Mali by an agricultural research station and an extension project. It highlights the obstacles and opportunities encountered by the SRAC and PRECAD, as well as the successes and difficulties arising from their work.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Die chronisch-kritische Beinischämie (CLI) ist die schwerste Form der peripher-arteriellen Verschlusskrankheit und geht mit einem erhöhten Risiko für letale kardiovaskuläre Ereignisse einher. Die meisten Patienten überleben aber die ersten Jahre nach Diagnosestellung und sind für den Erhalt ihrer Selbständigkeit auf eine nachhaltige Verbesserung der Beindurchblutung angewiesen. Dieser CME-Artikel fasst die chirurgischen und endovaskulären Optionen zur Revaskularisierung zusammen und geht auf deren Nachhaltigkeit bei CLI ein. Grenzen der verfügbaren Evidenz werden aufgezeigt. Sie beruhen vor allem auf dem Fehlen einer einheitlichen Definition des Behandlungserfolges. Ein klinisch orientierter Lösungsvorschlag wird diskutiert, der helfen könnte, die verschiedenen Behandlungsindikationen zu schärfen. Da sich aber nur die wenigsten Patienten gleich gut für verschiedene Verfahren eignen, werden CLI-Patienten auch in Zukunft am besten in einem interdisziplinär arbeitenden Team betreut sein.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Biolimus-eluting stents (BESs) with a biodegradable polymer in abluminal coating achieve more complete coverage at 9 months compared with sirolimus-eluting stents (SESs) with a durable polymer, as assessed by optical coherence tomography (OCT). Whether this advantage persists or augments after complete resorption of the polymer (>12 months) is unknown.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Compared with bare metal stents (BMS), early generation drug-eluting stents (DES) reduce the risk of revascularisation in patients with ST-elevation myocardial infarction (STEMI) at the expense of an increased risk of very late stent thrombosis (ST). Durable polymer coatings for controlled drug release have been identified as a potential trigger for these late adverse events and this has led to the development of newer generation DES with durable and biodegradable polymer surface coatings with improved biocompatibility. In a recent all-comers trial, biolimus-eluting stents with a biodegradable polymer surface coating were found to reduce the risk of very late ST by 80% compared with sirolimus-eluting stents with durable polymer, which also translated into a lower risk of cardiac death and myocardial infarction (MI) beyond one year.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The efficacy of durable polymer drug-eluting stents (DES) is delivered at the expense of delayed healing of the stented vessel. Biodegradable polymer DES aim to avoid this shortcoming and may potentially improve long-term clinical outcomes, with benefit expected to accrue over time. We sought to compare long-term outcomes in patients treated with biodegradable polymer DES vs. durable polymer sirolimus-eluting stents (SES).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Preliminary evidence suggests that the multikinase inhibitor sorafenib has clinical activity in FLT3-ITD-positive (FLT3-ITD) acute myeloid leukemia (AML). However, the quality and sustainability of achievable remissions and clinical variables that influence the outcome of sorafenib monotherapy are largely undefined. To address these questions, we evaluated sorafenib monotherapy in 65 FLT3-ITD AML patients treated at 23 centers. All but two patients had relapsed or were chemotherapy-refractory after a median of three prior chemotherapy cycles. Twenty-nine patients (45%) had undergone prior allogeneic stem cell transplantation (allo-SCT). The documented best responses were: hematological remission in 24 patients (37%), bone marrow remission in 5 patients (8%), complete remission (with and without normalization of peripheral blood counts) in 15 patients (23%) and molecular remission with undetectable FLT3-ITD mRNA in 10 patients (15%), respectively. Seventeen of the patients without prior allo-SCT (47%) developed sorafenib resistance after a median treatment duration of 136 days (range, 56-270 days). In contrast, allo-SCT patients developed sorafenib resistance less frequently (38%) and significantly later (197 days, range 38-225 days; P=0.03). Sustained remissions were seen exclusively in the allo-SCT cohort. Thus, sorafenib monotherapy has significant activity in FLT3-ITD AML and may synergize with allogeneic immune effects to induce durable remissions.Leukemia advance online publication, 8 May 2012; doi:10.1038/leu.2012.105.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Spinal muscular atrophy (SMA) is a lethal hereditary disease caused by homozygous deletion/inactivation of the survival of motoneuron 1 (SMN1) gene. The nearby SMN2 gene, despite its identical coding capacity, is only an incomplete substitute, because a single nucleotide difference impairs the inclusion of its seventh exon in the messenger RNA (mRNA). This splicing defect can be corrected (transiently) by specially designed oligonucleotides. Here we have developed a more permanent correction strategy based on bifunctional U7 small nuclear RNAs (snRNAs). These carry both an antisense sequence that allows specific binding to exon 7 and a splicing enhancer sequence that will improve the recognition of the targeted exon. When expression cassettes for these RNAs are stably introduced into cells, the U7 snRNAs become incorporated into small nuclear ribonucleoprotein (snRNP) particles that will induce a durable splicing correction. We have optimized this strategy to the point that virtually all SMN2 pre-mRNA becomes correctly spliced. In fibroblasts from an SMA patient, this approach induces a prolonged restoration of SMN protein and ensures its correct localization to discrete nuclear foci (gems).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: To assess perioperative outcomes and blood pressure (BP) responses to an implantable carotid sinus baroreflex activating system being investigated for the treatment of resistant hypertension. METHODS: We report on the first seventeen patients enrolled in a multicenter study. Bilateral perivascular carotid sinus electrodes (CSL) and a pulse generator (IPG) are permanently implanted. Optimal placement of the CSL is determined by intraoperative BP responses to test activations. Acute BP responses were tested postoperatively and during the first four months of follow-up. RESULTS: Prior to implant, BP was 189.6+/-27.5/110.7+/-15.3 mmHg despite stable therapy (5.2+/-1.8 antihypertensive drugs). The mean procedure time was 202+/-43 minutes. No perioperative strokes or deaths occurred. System tests performed 1 or up to 3 days postoperatively resulted in significant (all p < or = 0.0001) mean maximum reduction, with standard deviations and 95% confidence limits for systolic BP, diastolic BP and heart rate of 28+/-22 (17, 39) mmHg, 16+/-11 (10, 22) mmHg and 8+/-4 (6, 11) BPM, respectively. Repeated testing during 3 months of therapeutic electrical activation demonstrated a durable response. CONCLUSIONS: These preliminary data suggest an acceptable safety of the procedure with a low rate of adverse events and support further clinical development of baroreflex activation as a new concept to treat resistant hypertension.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Despite the success of drug-eluting stents (DES) in reducing restenosis and the need for target vessel revascularization, several deficiencies have been unraveled since their first clinical application including the risk of stent thrombosis, undesired effects due to the stent polymer as well as the stent itself, and incomplete inhibition of restenosis (especially in complex lesions). Several novel stent systems are being investigated in order to address these issues. In second-generation DES, the rapamycin analogues zotarolimus and everolimus (and more recently biolimus) have been most extensively studied. Furthermore, special stent-coatings to actively promote endothelial healing (in order to reduce the risk of stent thrombosis) and to further reduce restenosis have been employed. To avoid undesirable effects of currently applied (durable) polymers, biocompatible and bioabsorbable polymers as well as DES delivery systems without the need for a polymer have been developed. Bioabsorbable stents, both polymeric and metallic, were developed to decrease potential late complications after stent implantation. Although most of these innovative novel principles intuitively seem appealing and demonstrate good results in initial clinical evaluations, long-term large-scale studies are necessary in order to reliably assess whether these novel systems are truly superior to first-generation DES with respect to safety and efficacy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: At a mean follow-up of 3.1 years, twenty-seven consecutive repairs of massive rotator cuff tears yielded good and excellent clinical results despite a retear rate of 37%. Patients with a retear had improvement over the preoperative state, but those with a structurally intact repair had a substantially better result. The purpose of this study was to reassess the same patients to determine the long-term functional and structural results. METHODS: At a mean follow-up interval of 9.9 years, twenty-three of the twenty-seven patients returned for a review and were examined clinically, radiographically, and with magnetic resonance imaging with use of a methodology identical to that used at 3.1 years. RESULTS: Twenty-two of the twenty-three patients remained very satisfied or satisfied with the result. The mean subjective shoulder value was 82% (compared with 80% at 3.1 years). The mean relative Constant score was 85% (compared with 83% at 3.1 years). The retear rate was 57% at 9.9 years (compared with 37% at 3.1 years; p = 0.168). Patients with an intact repair had a better result than those with a failed reconstruction with respect to the mean absolute Constant score (81 compared with 64 points, respectively; p = 0.015), mean relative Constant score (95% and 77%; p = 0.002), and mean strength of abduction (5.5 and 2.6 kg; p = 0.007). The mean retear size had increased from 882 to 1164 mm(2) (p = 0.016). Supraspinatus and infraspinatus muscle fatty infiltration had increased (p = 0.004 and 0.008, respectively). Muscles with torn tendons preoperatively showed more fatty infiltration than muscles with intact tendons preoperatively, regardless of repair integrity. Shoulders with a retear had a significantly higher mean acromion index than those without retear (0.75 and 0.65, respectively; p = 0.004). CONCLUSIONS: Open repair of massive rotator cuff tears yielded clinically durable, excellent results with high patient satisfaction at a mean of almost ten years postoperatively. Conversely, fatty muscle infiltration of the supraspinatus and infraspinatus progressed, and the retear size increased over time. The preoperative integrity of the tendon appeared to be protective against muscle deterioration. A wide lateral extension of the acromion was identified as a previously unknown risk factor for retearing.