274 resultados para Valve tricuspide
Resumo:
Symptomatic overdrainage in children with shunt-treated hydrocephalus represents one of the more difficult shunt-related diseases and may require repeated surgery. Gravity-assisted valve design has become a standard device to avoid overdrainage in many European pediatric hydrocephalus centers. However, the use of a gravitational valve for relieving symptoms associated with overdrainage has not yet been addressed. The goal of this study was to evaluate the effectiveness of a gravitational valve in the treatment of symptomatic overdrainage in children with shunts.
Resumo:
AimsTranscatheter aortic valve implantation (TAVI) is an established treatment alternative to surgical aortic valve replacement in high-risk and inoperable patients and outcomes among patients with estimated low or intermediate risk remain to be determined. The aim of this study was to assess clinical outcomes among patients with estimated low or intermediate surgical risk undergoing TAVI.Methods and resultsBetween August 2007 and October 2011, 389 consecutive patients underwent TAVI and were categorized according to the Society of Thoracic Surgeons (STS) score into low (STS < 3%; n = 41, 10.5%), intermediate (STS ≥3% and ≤8%, n = 254, 65.3%), and high-risk (STS > 8%; n = 94, 24.2%) groups for the purpose of this study. Significant differences were found between the groups (low risk vs. intermediate risk vs. high risk) for age (78.2 ± 6.7 vs. 82.7 ± 5.7 vs. 83.7 ± 4.9, P < 0.001), body mass index (28.1 ± 6.1 vs. 26.5 ± 4.9 vs. 24.4 ± 4.6, P < 0.001), chronic renal failure (34 vs. 67 vs. 90%, P < 0.001), all-cause mortality at 30 days (2.4 vs. 3.9 vs. 14.9%, P = 0.001), and all-cause mortality at 1 year (10.1 vs. 16.1 vs. 34.5%, P = 0.0003). No differences were observed with regards to cerebrovascular accidents and myocardial infarction during 1-year follow-up.ConclusionIn contemporary practice, TAVI is not limited to inoperable or STS-defined high-risk patients and should be guided by the decision of an interdisciplinary Heart Team. Compared with patients at calculated high risk, well-selected patients with STS-defined intermediate or low risk appear to have favourable clinical outcomes.
Resumo:
Atrial fibrillation (AF) is an important risk factor for stroke and is common among elderly patients undergoing transcatheter aortic valve implantation. The aim of this study was to assess the impact of AF on clinical outcomes among patients undergoing transcatheter aortic valve implantation.
Resumo:
Unfavorable immediate or delayed results after transcatheter aortic valve implantation (TAVI) may be a consequence of bioprosthesis malfunctioning, malpositioning, embolization, or degeneration. Deployment of a second valve within the first one implanted (TAVI-in-TAV) may be a potentially helpful therapeutic strategy.
Improvement of physical and mental health after transfemoral transcatheter aortic valve implantation
Resumo:
Transcatheter aortic valve implantation (TAVI) has emerged as a treatment alternative to surgical aortic valve replacement in elderly high-risk patients with symptomatic severe aortic stenosis. In this patient population, rapid improvement or restoration of quality of life (QoL) is at least as important as improved clinical outcomes. The purpose of the present study was to assess changes in QoL in response to TAVI.
Resumo:
Previous reports prove the safety and efficacy of cardiac pacing employing a guidewire in the left ventricle as unipolar pacing electrode. We describe the use of left ventricular guidewire pacing as an alternative to conventional transvenous temporary right ventricular pacing in the context of transcatheter aortic valve implantation. © 2012 Wiley Periodicals, Inc.
Resumo:
This study sought to report on the pathology of transcatheter aortic valves explanted at early and late time points after transcatheter aortic valve implantation.
Resumo:
Assessment of elderly patients with severe aortic stenosis and decisions in terms of management strategy (conservative with or without balloon aortic valvuloplasty, transcatheter aortic valve implantation (TAVI) or surgical aortic valve replacement) are complex and warrant a multidisciplinary approach involving collaboration between experienced cardiac surgeons, interventional cardiologists, cardiac imaging specialists, anaesthesiologists, geriatricians and a specialised nursing staff. Patient history, comorbid conditions, perioperative risk stratification as well as anatomical and procedural considerations require careful review on an individual, case-by-case basis and have a major impact on treatment allocation. The aims of this article are to provide insights into the fundamental role of appropriate patient screening and selection, and to review the nature, management and prevention of the most important procedural complications associated with the TAVI procedure.
Resumo:
Transcatheter aortic valve implantation (TAVI) for the treatment of symptomatic severe aortic stenosis has emerged as an effective treatment for high risk patients. In 2002 TAVI was performed for the first time in a human by Alain Cribier, using an antegrade access approach via the femoral vein, crossing the intra-atrial septum after puncture and passing the native aortic valve in the direction of blood flow. This technically demanding approach was subsequently replaced by retrograde transfemoral arterial access. For patients with severe peripheral vascular disease or inadequately sized femoral arteries, the transapical route provides an alternative route with antegrade access to the aortic valve via puncture of the anterolateral wall of the left ventricle. The transsubclavian access approach using most frequently the left subclavian artery and direct transaortic access have been introduced more recently and attest to the versatility of TAVI in terms of access site. This article will focus on the different access site options available to operators, provide a step-by-step guide through the procedure, and a detailed description of the technological evolution of transcatheter heart valve systems.
Resumo:
The aim of the current Valve Academic Research Consortium (VARC)-2 initiative was to revisit the selection and definitions of transcatheter aortic valve implantation (TAVI) clinical endpoints to make them more suitable to the present and future needs of clinical trials. In addition, this document is intended to expand the understanding of patient risk stratification and case selection.
Resumo:
The aim of the current Valve Academic Research Consortium (VARC)-2 initiative was to revisit the selection and definitions of transcatheter aortic valve implantation (TAVI) clinical endpoints to make them more suitable to the present and future needs of clinical trials. In addition, this document is intended to expand the understanding of patient risk stratification and case selection.
Resumo:
The aim of the current Valve Academic Research Consortium (VARC)-2 initiative was to revisit the selection and definitions of transcatheter aortic valve implantation (TAVI)clinical endpoints to make them more suitable to the present and future needs of clinical trials. In addition, this document is intended to expand the understanding of patient risk stratification and case selection.
Resumo:
The aim of the current Valvular Academic Research Consortium (VARC)-2 initiative was to revisit the selection and definitions of transcatheter aortic valve implantation (TAVI)- clinical endpoints to make them more suitable to the present and future needs of clinical trials. In addition, this document is intended to expand understanding of patient risk stratification and case selection.
Resumo:
In this study, we show the use of three-dimensional printing models for preoperative planning of transcatheter valve replacement in a patient with an extreme porcelain aorta. A 70-year-old man with severe aortic stenosis and a porcelain aorta was referred to our center for transcatheter aortic valve replacement. Unfortunately, the patient died after the procedure because of a potential ischemic event. Therefore, we decided to fabricate three-dimensional models to evaluate the potential effects of these constructs for previous surgical planning and simulation of the transcatheter valve replacement.