90 resultados para ULTRASOUND-GUIDED BIOPSY
Resumo:
When conservative treatment modalities provide inadequate relief, interventional techniques play an important role in the management of chronic pain patients. They are performed in diagnostic or therapeutic intention (or both) and either directly target the pain generating anatomic structure (e.g. intraarticular joint injections) or the neural structures which are thought to mediate the experience of pain (e.g. facet joint nerve blocks, spinal cord stimulation). In order to enhance precision and patient safety, these interventions are performed with image guidance; of which fluoroscopy is the most commonly used technique. CT- or Ultrasound-guided techniques are also performed. This article is an overview of the indications and results of the most commonly performed interventional techniques used in chronic pain treatment with focus on spinal interventional procedures.
Resumo:
For the past 10 years, medical imaging techniques have been increasingly applied to forensic investigations. To obtain histological and toxicological information, tissue and liquid samples are required. In this article, we describe the development of a low-cost, secure, and reliable approach for a telematic add-on for remotely planning biopsies on the Virtobot robotic system. Data sets are encrypted and submitted over the Internet. A plugin for the OsiriX medical image viewer allows for remote planning of needle trajectories that are used for needle placement. The application of teleradiological methods to image-guided biopsy in the forensic setting has the potential to reduce costs and, in conjunction with a mobile computer tomographic scanner, allows for tissue sampling in a mass casualty situation involving nuclear, biological, or chemical agents, in a manner that minimizes the risk to involved staff.
Resumo:
There are conflicting results with regard to the use of catheter-based techniques for continuous paravertebral block. Local anaesthetic spread within the paravertebral space is limited and the clinical effect is often variable. Discrepancies between needle tip position and final catheter position can also be problematic. The aim of this proof-of-concept study was to assess the reliability of placing a newly developed coiled catheter in human cadavers. Sixty Tuohy needles and coiled catheters were placed under ultrasound guidance, three on each side of the thoracic vertebral column in 10 human cadavers. Computed tomography was used to assess needle tip and catheter tip locations. No catheter was misplaced into the epidural, pleural or prevertebral spaces. The mean (SD) distance between catheter tips and needle tips was 8.2 (4.9) mm. The median (IQR [range]) caudo-cephalad spread of contrast dye injectate through a subset of 20 catheters was 4 (4-5[3-8]) thoracic segments. All catheters were removed without incident. Precise paravertebral catheter placement can be achieved using ultrasound-guided placement of a coiled catheter.
Resumo:
The aim of this prospective clinical study was to evaluate the location of paravertebral catheters that were placed using the classical landmark puncture technique and to correlate the distribution of contrast dye injected through the catheters with the extent of somatic block. Paravertebral catheter placement was attempted in 31 patients after video-assisted thoracic surgery. In one patient, an ultrasound-guided approach was chosen after failed catheter placement using the landmark method. A fluoroscopic examination in two planes using contrast dye was followed by injection of local anaesthetic and subsequent clinical testing of the extent of the anaesthetised area. In nine patients (29%), spread of contrast dye was not seen within the paravertebral space as intended. Misplaced catheters were in the epidural space (three patients), in the erector spinae musculature (five patients), and in the pleural space (one patient). There was also a discrepancy between the radiological findings and the observed distribution of loss of sensation. We have demonstrated an unacceptably high misplacement rate of paravertebral catheters using the landmark method. Additional research is required to compare the efficacy and safety of continuous paravertebral block using ultrasound-guided techniques or surgical inserted catheters.
Resumo:
Early prenatal diagnosis and in utero therapy of certain fetal diseases have the potential to reduce fetal morbidity and mortality. The intrauterine transplantation of stem cells provides in some instances a therapeutic option before definitive organ failure occurs. Clinical experiences show that certain diseases, such as immune deficiencies or inborn errors of metabolism, can be successfully treated using stem cells derived from bone marrow. However, a remaining problem is the low level of engraftment that can be achieved. Efforts are made in animal models to optimise the graft and study the recipient's microenvironment to increase long-term engraftment levels. Our experiments in mice show similar early homing of allogeneic and xenogeneic stem cells and reasonable early engraftment of allogeneic murine fetal liver cells (17.1% donor cells in peripheral blood 4 weeks after transplantation), whereas xenogeneic HSC are rapidly diminished due to missing self-renewal and low differentiation capacities in the host's microenvironment. Allogeneic murine fetal liver cells have very good long-term engraftment (49.9% donor cells in peripheral blood 16 weeks after transplantation). Compared to the rodents, the sheep model has the advantage of body size and gestation comparable to the human fetus. Here, ultrasound-guided injection techniques significantly decreased fetal loss rates. In contrast to the murine in utero model, the repopulation capacities of allogeneic ovine fetal liver cells are lower (0.112% donor cells in peripheral blood 3 weeks after transplantation). The effect of MHC on engraftment levels seems to be marginal, since no differences could be observed between autologous and allogeneic transplantation (0.117% donor cells vs 0.112% donor cells in peripheral blood 1 to 2 weeks after transplantation). Further research is needed to study optimal timing and graft composition as well as immunological aspects of in utero transplantation.
Resumo:
OBJECTIVE: The purpose of this study was to assess the feasibility of autologous stem cell transplantation in fetal sheep and to compare short-term engraftment of allogeneic and autologous fetal liver stem cells in an immunocompetent large animal model. STUDY DESIGN: Fetal liver stem cells were collected from preimmune sheep fetuses with an open or ultrasound-guided technique. After being labeled with PKH26, the cells were transplanted intraperitoneally into allogeneic and autologous fetal recipients at 48 to 64 days of gestation. Engraftment was determined by flow cytometry and real-time polymerase chain reaction 1 to 2 weeks after transplantation. RESULTS: Fetal loss rate was 29% (allogeneic transplantation) and 73% (autologous transplantation). Engraftment of donor cells was found in all fetuses, with a level of < or =4.7% in fetal liver, spleen, bone marrow, blood and thymus. Overall, there was no difference between allogeneic and autologous grafts. CONCLUSION: Autologous in utero transplantation of fetal liver stem cells in fetal sheep is feasible, but yields a high loss rate. Differences in the major histocompatibility complex between donor and recipient seems not to have a major impact on stem cell engraftment early in gestation; major histocompatibility complex-independent donor/host competition might be responsible for low engraftment in immunocompetent recipients.
Resumo:
OBJECTIVES: To map the primary prostatic lymphatic landing sites using a multimodality technique. METHODS: Thirty-four patients with organ-confined prostate cancer (cT1-cT2; cN0) underwent single-photon emission computed tomography fused with data from computed tomography (SPECT/CT) (n=33) or magnetic resonance imaging (SPECT/MRI) (n=1) 1h after ultrasound-guided intraprostatic injection of technecium (Tc-99m) nanocolloid. The presence of lymph nodes (LNs) containing Tc-99m was confirmed intraoperatively with a gamma probe. A backup extended pelvic lymphadenectomy (PLND) was performed to preclude missed primary lymphatic landing sites. The SPECT/CT/MRI data sets were used to generate a three-dimensional projection of each LN site. RESULTS: A total of 317 LNs (median, 10 per patient; range, 3-19) were detected by SPECT/CT/MRI, 314 of which were confirmed by gamma probe. With an "extended" PLND, two thirds of all primary prostatic lymphatic landing sites are resected compared with only one third with a "limited" PLND. CONCLUSIONS: The multimodality technique presented here enables precise mapping of the primary prostatic lymphatic landing sites. PLND for prostate cancer should include not only the external and obturator regions as well as the portions medial and lateral to the internal iliac vessels, but also the common iliac LNs at least up to the ureteric crossing, thus removing approximately 75% of all nodes potentially harbouring metastasis.
Resumo:
BACKGROUND: Arterial puncture closure devices (APCD) are frequently used after cardiac catheterization. Here, the diagnosis and therapy of femoral artery complications after the use of the Angio-Seal APCD is reported. PATIENTS AND METHODS: The Angio-Seal APCD was deployed in 1600 patients undergoing transfemoral catheterization. RESULTS: In 7 of 1600 cases (0.4%) vascular complications occurred following Angio-Seal deployment. Diagnosis was made by duplex sonography. Intraoperative findings consisted of a complete occlusion with dissection of the femoral artery in all patients. In 6 cases, the femoral bifurcation had to be reconstructed after endarterectomy. Follow-up is complete with a mean of 6 months. CONCLUSION: The Angio-Seal device should not be used for closure of the superficial femoral artery and in patients with severe arteriosclerosis. The application of arteriography as well as the use of ultrasound-guided puncture is advisable. In all cases, surgical intervention was successful and an adequate therapy for management of complications.
Resumo:
Cystic adventitial degeneration is a rare non-atherosclerotic cause of peripheral arterial occlusive disease, mainly seen in young men without other evidence of vascular disease. Diagnosis will be established by clinical findings and by ultrasound or angiography and can be treated by excision or enucleation of the affected arterial segment or by percutaneous ultrasound-guided aspiration. However, the etiology of adventitial cysts remains unknown. We report a case of cystic adventitial degeneration showing a connection between the joint capsule and the adventitial cyst, supporting the theory that cystic adventitial degeneration may represent ectopic ganglia from adjacent joint capsules.
Resumo:
Objective In order to benefit from the obvious advantages of minimally invasive liver surgery there is a need to develop high precision tools for intraoperative anatomical orientation, navigation and safety control. In a pilot study we adapted a newly developed system for computer-assisted liver surgery (CALS) in terms of accuracy and technical feasibility to the specific requirements of laparoscopy. Here, we present practical aspects related to laparoscopic computer assisted liver surgery (LCALS). Methods Our video relates to a patient presenting with 3 colorectal liver metastases in Seg. II, III and IVa who was selected in an appropriate oncological setting for LCALS using the CAScination system combined with 3D MEVIS reconstruction. After minimal laparoscopic mobilization of the liver, a 4- landmark registration method was applied to enable navigation. Placement of microwave needles was performed using the targeting module of the navigation system and correct needle positioning was confirmed by intraoperative sonography. Ablation of each lesion was carried out by application of microwave energy at 100 Watts for 1 minute. Results To acquire an accurate (less 0.5 cm) registration, 4 registration cycles were necessary. In total, seven minutes were required to accomplish precise registration. Successful ablation with complete response in all treated areas was assessed by intraoperative sonography and confirmed by postoperative CT scan. Conclusions This teaching video demonstrates the theoretical and practical key points of LCALS with a special emphasis on preoperative planning, intraoperative registration and accuracy testing by laparoscopic methodology. In contrast to mere ultrasound-guided ablation of liver lesions, LCALS offers a more dimensional targeting and higher safety control. This is currently also in routine use to treat vanishing lesions and other difficult to target focal lesions within the liver.
Resumo:
Endoscopic ultrasound was developed initially in humans to overcome limitations of conventional ultrasound in examining certain internal organs due to intervening bone or air-filled structures. Endoscopic ultrasound has been used most widely in investigation of the gastrointestinal tract in humans, but many intrathoracic applications as well as endoscopic ultrasound-guided techniques have recently been described. Mediastinal and pulmonary structures can be examined with endoscopic ultrasound since a high frequency ultrasound probe can be brought into close contact with the areas of interest via a transesophageal approach. The purpose of this report is to describe the application of endoscopic ultrasound as an aid in the diagnosis of intrathoracic disease in the dog. Two dogs, one with a history of prior esophageal foreign body extraction, the other with apathy, weakness and dyspnea were referred for further investigation. Both dogs had caudal intrathoracic soft tissue opacities diagnosed radiographically, but their origin and nature were difficult to determine. Conventional ultrasound was limiting in both dogs due to their location and superimposition of gas-filled structures. With endosonography lesions were characterized more completely. We have found endoscopic ultrasound to be an elegant diagnostic tool for the investigation of radiographically detected intrathoracic lesions in the dog whose origins are difficult to determine or do not lend themselves to investigation by conventional ultrasound. Endoscopic ultrasound provides valuable diagnostic information complementary to that provided radiographically which aids in therapeutic planning. Endoscopic ultrasound was also more sensitive for detecting mediastinal lymphadenomegaly than radiography in one of the dogs. An additional advantage of endoscopic ultrasound is the fact that US-guided tissue sampling can be performed during the examination.
Resumo:
OBJECTIVES The intensity of post-egg retrieval pain is underestimated, with few studies examining post-procedural pain and predictors to identify women at risk for severe pain. We evaluated the influence of pre-procedural hormonal levels, ovarian factors, as well as mechanical temporal summation (mTS) as predictors for post-egg retrieval pain in women undergoing in vitro fertilization (IVF). METHODS Eighteen women scheduled for ultrasound-guided egg retrieval under standardized anesthesia and post-procedural analgesia were enrolled. Pre-procedural mTS, questionnaires, clinical data related to anesthesia and the procedure itself, post-procedural pain scores and pain medication for breakthrough pain were recorded. Statistical analysis included Pearson product moment correlations, Mann-Whitney U tests and multiple linear regressions. RESULTS Average peak post-egg retrieval pain during the first 24 hours was 5.0±1.6 on an NRS scale (0=no pain, 10=worst pain imaginable). Peak post-egg retrieval pain was correlated with basal antimullerian hormone (AMH) (r=0.549, P=0.018), pre-procedural peak estradiol (r=0.582, P=0.011), total number of follicles (r=0.517, P=0.028) and number of retrieved eggs (r=0.510, P=0.031). Ovarian hyperstimulation syndrome (OHSS) (n=4) was associated with higher basal AMH (P=0.004), higher peak pain scores (P=0.049), but not with peak estradiol (P=0.13). The mTS did not correlate with peak post-procedural pain (r=0.266, P=0.286), or peak estradiol level (r=0.090, P=0.899). DISCUSSION Peak post-egg retrieval pain intensity was higher than anticipated. Our results suggest that post-egg retrieval pain can be predicted by baseline AMH, high peak estradiol, and OHSS. Further studies to evaluate intra- and post-procedural pain in this population are needed, as well as clinical trials to assess post-procedural analgesia in women presenting with high hormonal levels.
Resumo:
Sentinel lymph node biopsy (SLNB) for cutaneous malignancies usually carried out with radioactive nanocolloids (Tc-99m). The SLNE is controversially discussed internationally. This is especially given to the high false-negative rate up to 44 %. An alternative could be the fluorescent dye indocyanine green (ICG).