64 resultados para Thorax


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Few data exist on tuberculosis (TB) incidence according to time from HIV seroconversion in high-income countries and whether rates following initiation of a combination of antiretroviral treatments (cARTs) differ from those soon after seroconversion. Methods Data on individuals with well estimated dates of HIV seroconversion were used to analyse post-seroconversion TB rates, ending at the earliest of 1 January 1997, death or last clinic visit. TB rates were also estimated following cART initiation, ending at the earliest of death or last clinic visit. Poisson models were used to examine the effect of current and past level of immunosuppression on TB risk after cART initiation. Results Of 19 815 individuals at risk during 1982–1996, TB incidence increased from 5.89/1000 person-years (PY) (95% CI 3.77 to 8.76) in the first year after seroconversion to 10.56 (4.83 to 20.04, p=0.01) at 10 years. Among 11 178 TB-free individuals initiating cART, the TB rate in the first year after cART initiation was 4.23/1000 PY (3.07 to 5.71) and dropped thereafter, remaining constant from year 2 onwards averaging at 1.64/1000 PY (1.29 to 2.05). Current CD4 count was inversely associated with TB rates, while nadir CD4 count was not associated with TB rates after adjustment for current CD4 count, HIV-RNA at cART initiation. Conclusions TB risk increases with duration of HIV infection in the absence of cART. Following cART initiation, TB incidence rates were lower than levels immediately following seroconversion. Implementation of current recommendations to prevent TB in early HIV infection could be beneficial.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A planar-spiral antenna to be used in an ultrawideband (UWB) radar system for heart activity monitoring is presented. The antenna, named “twin,” is constituted by two spiral dipoles in a compact structure. The reflection coefficient at the feed point of the dipoles is lower than −8 dB over the 3–12 GHz band, while the two-dipoles coupling is about −20 dB. The radiated beam is perpendicular to the plane of the spiral, so the antenna is wearable and it may be an optimal radiator for a medical UWB radar for heart rate detection. The designed antenna has been also used to check some hypotheses about the UWB radar heart activity detection mechanism. The radiation impedance variation, caused by the thorax vibrations associated with heart activity, seems to be the most likely explanation of the UWB radar operation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIM To compare the computed tomography (CT) dose and image quality with the filtered back projection against the iterative reconstruction and CT with a minimal electronic noise detector. METHODS A lung phantom (Chest Phantom N1 by Kyoto Kagaku) was scanned with 3 different CT scanners: the Somatom Sensation, the Definition Flash and the Definition Edge (all from Siemens, Erlangen, Germany). The scan parameters were identical to the Siemens presetting for THORAX ROUTINE (scan length 35 cm and FOV 33 cm). Nine different exposition levels were examined (reference mAs/peek voltage): 100/120, 100/100, 100/80, 50/120, 50/100, 50/80, 25/120, 25/100 and 25 mAs/80 kVp. Images from the SOMATOM Sensation were reconstructed using classic filtered back projection. Iterative reconstruction (SAFIRE, level 3) was performed for the two other scanners. A Stellar detector was used with the Somatom Definition Edge. The CT doses were represented by the dose length products (DLPs) (mGycm) provided by the scanners. Signal, contrast, noise and subjective image quality were recorded by two different radiologists with 10 and 3 years of experience in chest CT radiology. To determine the average dose reduction between two scanners, the integral of the dose difference was calculated from the lowest to the highest noise level. RESULTS When using iterative reconstruction (IR) instead of filtered back projection (FBP), the average dose reduction was 30%, 52% and 80% for bone, soft tissue and air, respectively, for the same image quality (P < 0.0001). The recently introduced Stellar detector (Sd) lowered the radiation dose by an additional 27%, 54% and 70% for bone, soft tissue and air, respectively (P < 0.0001). The benefit of dose reduction was larger at lower dose levels. With the same radiation dose, an average of 34% (22%-37%) and 25% (13%-46%) more contrast to noise was achieved by changing from FBP to IR and from IR to Sd, respectively. For the same contrast to noise level, an average of 59% (46%-71%) and 51% (38%-68%) dose reduction was produced for IR and Sd, respectively. For the same subjective image quality, the dose could be reduced by 25% (2%-42%) and 44% (33%-54%) using IR and Sd, respectively. CONCLUSION This study showed an average dose reduction between 27% and 70% for the new Stellar detector, which is equivalent to using IR instead of FBP.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE To determine the image quality of an iterative reconstruction (IR) technique in low-dose MDCT (LDCT) of the chest of immunocompromised patients in an intraindividual comparison to filtered back projection (FBP) and to evaluate the dose reduction capability. MATERIALS AND METHODS 30 chest LDCT scans were performed in immunocompromised patients (Brilliance iCT; 20-40 mAs; mean CTDIvol: 1.7 mGy). The raw data were reconstructed using FBP and the IR technique (iDose4™, Philips, Best, The Netherlands) set to seven iteration levels. 30 routine-dose MDCT (RDCT) reconstructed with FBP served as controls (mean exposure: 116 mAs; mean CDTIvol: 7.6 mGy). Three blinded radiologists scored subjective image quality and lesion conspicuity. Quantitative parameters including CT attenuation and objective image noise (OIN) were determined. RESULTS In LDCT high iDose4™ levels lead to a significant decrease in OIN (FBP vs. iDose7: subscapular muscle 139.4 vs. 40.6 HU). The high iDose4™ levels provided significant improvements in image quality and artifact and noise reduction compared to LDCT FBP images. The conspicuity of subtle lesions was limited in LDCT FBP images. It significantly improved with high iDose4™ levels (> iDose4). LDCT with iDose4™ level 6 was determined to be of equivalent image quality as RDCT with FBP. CONCLUSION iDose4™ substantially improves image quality and lesion conspicuity and reduces noise in low-dose chest CT. Compared to RDCT, high iDose4™ levels provide equivalent image quality in LDCT, hence suggesting a potential dose reduction of almost 80%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to elaborate on the advantages and limits of computed tomography (CT) in the differentiation of thoracic lesions, in particular neoplasias. In the course of the investigation CT-scans of the thorax of 31 dogs with lesions in the area of the lungs or mediastinum were evaluated. The lesions were rated by morphology, distribution pattern, attenuation values and contrast-enhancement. Biopsies or the whole body underwent a pathohistological examination. Of the 31 dogs 17 had neoplastic and 14 had inflammatory lesions in the thoracic region. With help of the CT, the exact localisations of the different lesions was possible in most cases. Due to their characteristic morphologies, distribution patterns and attenuation values the differentiation between inflammatory and neoplastic lesions was possible in most cases (n=25/31) on the basis of the CT-scans. Mean non-enhanced CT attenuation values of the neoplastic lesions ranged between 31 and 50 HU, of the inflammatory lesions between -251 and 9 HU. Both neoplastic and inflammatory lesions showed contrast enhancement (between 14 and 38 HU and between 2 and 95 HU respectively). The mediastinal abcesses enhanced mainly on the periphery of the lesion. A differentiation of the various types of neoplastic lesions based on the non-enhanced attenuation values was not successful. Only metastasis could be differentiated because of their distribution pattern.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE A beamlet based direct aperture optimization (DAO) for modulated electron radiotherapy (MERT) using photon multileaf collimator (pMLC) shaped electron fields is developed and investigated. METHODS The Swiss Monte Carlo Plan (SMCP) allows the calculation of dose distributions for pMLC shaped electron beams. SMCP is interfaced with the Eclipse TPS (Varian Medical Systems, Palo Alto, CA) which can thus be included into the inverse treatment planning process for MERT. This process starts with the import of a CT-scan into Eclipse, the contouring of the target and the organs at risk (OARs), and the choice of the initial electron beam directions. For each electron beam, the number of apertures, their energy, and initial shape are defined. Furthermore, the DAO requires dose-volume constraints for the structures contoured. In order to carry out the DAO efficiently, the initial electron beams are divided into a grid of beamlets. For each of those, the dose distribution is precalculated using a modified electron beam model, resulting in a dose list for each beamlet and energy. Then the DAO is carried out, leading to a set of optimal apertures and corresponding weights. These optimal apertures are now converted into pMLC shaped segments and the dose calculation for each segment is performed. For these dose distributions, a weight optimization process is launched in order to minimize the differences between the dose distribution using the optimal apertures and the pMLC segments. Finally, a deliverable dose distribution for the MERT plan is obtained and loaded back into Eclipse for evaluation. For an idealized water phantom geometry, a MERT treatment plan is created and compared to the plan obtained using a previously developed forward planning strategy. Further, MERT treatment plans for three clinical situations (breast, chest wall, and parotid metastasis of a squamous cell skin carcinoma) are created using the developed inverse planning strategy. The MERT plans are compared to clinical standard treatment plans using photon beams and the differences between the optimal and the deliverable dose distributions are determined. RESULTS For the idealized water phantom geometry, the inversely optimized MERT plan is able to obtain the same PTV coverage, but with an improved OAR sparing compared to the forwardly optimized plan. Regarding the right-sided breast case, the MERT plan is able to reduce the lung volume receiving more than 30% of the prescribed dose and the mean lung dose compared to the standard plan. However, the standard plan leads to a better homogeneity within the CTV. The results for the left-sided thorax wall are similar but also the dose to the heart is reduced comparing MERT to the standard treatment plan. For the parotid case, MERT leads to lower doses for almost all OARs but to a less homogeneous dose distribution for the PTV when compared to a standard plan. For all cases, the weight optimization successfully minimized the differences between the optimal and the deliverable dose distribution. CONCLUSIONS A beamlet based DAO using multiple beam angles is implemented and successfully tested for an idealized water phantom geometry and clinical situations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND In patients with acute pulmonary embolism (PE), rapid and accurate risk assessment is paramount in selecting the appropriate treatment strategy. The prognostic value of right ventricular dysfunction (RVD) assessed by multidetector CT (MDCT) in normotensive patients with PE has lacked adequate validation. METHODS The study defined MDCT-assessed RVD as a ratio of the RV to the left ventricle short axis diameter greater than 0.9. Outcomes assessed through 30 days after the diagnosis of PE included all-cause mortality and 'complicated course', which consisted of death from any cause, haemodynamic collapse or recurrent PE. RESULTS MDCT detected RVD in 533 (63%) of the 848 enrolled patients. Those with RVD on MDCT more frequently had echocardiographic RVD (31%) than those without RVD on MDCT (9.2%) (p<0.001). Patients with RVD on MDCT had significantly higher brain natriuretic peptide (269±447 vs 180±457 pg/ml, p<0.001) and troponin (0.10±0.43 vs 0.03±0.24 ng/ml, p=0.001) levels in comparison with those without RVD on MDCT. During follow-up, death occurred in 25 patients with and in 13 patients without RVD on MDCT (4.7% vs 4.3%; p=0.93). Those with and those without RVD on MDCT had a similar frequency of complicated course (3.9% vs 2.3%; p=0.30). CONCLUSIONS The PROgnosTic valuE of CT study showed a relationship between RVD assessed by MDCT and other markers of cardiac dysfunction around the time of PE diagnosis, but did not demonstrate an association between MDCT-RVD and prognosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The perioperative management of patients with mediastinal masses is a special clinical challenge in our field. Even though regional anaesthesia is normally the first choice, in some cases it is not feasible due to the method of operation. In these cases general anaesthesia is the second option but can lead to respiratory and haemodynamic decompensation due to tumor-associated compression syndrome (mediastinal mass syndrome). The appropriate treatment begins with the preoperative risk classification on the basis of clinical and radiological findings. In addition to anamnesis, chest radiograph, and CT, dynamical methods (e.g. pneumotachography and echocardiography) should be applied to verify possible intraoperative compression syndromes. The induction of general anaesthesia is to be realized in awake-fiberoptic intubation with introduction of the tube via nasal route while maintaining the spontaneous breathing of the patient. The anaesthesia continues with short effective agents applied inhalative or iv. If possible from the point of operation, agents of muscle relaxation are not to be applied. If the anaesthesia risk is classified as uncertain or unsafe, depending on the location of tumor compression (tracheobronchial tree, pulmonary artery, superior vena cava), alternative techniques of securing the respiratory tract (different tubes, rigid bronchoscope) and cardiopulmonary bypass with extracorporal oxygen supply are prepared. For patients with severe clinical symptoms and extensive mediastinal mass, the preoperative cannulation of femoral vessels is also recommended. In addition to fulfilling technical and personnel requirements, an interdisciplinary cooperation of participating fields is the most important prerequisite for the optimal treatment of patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Herzchirurgische Eingriffe sind nicht selten mit neurologischen Komplikationen verbunden. Die Ziele des Neuromonitorings in der Kardioanästhesie liegen in der Vermeidung derartiger Komplikationen, zum Beispiel durch die Detektion zerebraler Ischämien, die Erkennung einer inadäquaten Narkosetiefe oder die Überwachung von neuroprotektiven Maßnahmen. DGAI, DGTHG und SGAR empfehlen für die Herzchirurgie den Einsatz eines prozessierten EEGs bei totalintravenöser Anästhesie, bei tiefem hypothermem Kreislaufstillstand sowie bei Risikopatienten für Awareness. Bei Karotis-Thrombendartektomien wird die Ableitung von somatosensiblen Potenzialen (SSEP) als Verfahren der ersten Wahl angeraten. Falls ein SSEP-Gerät nicht zur Verfügung steht, wird die Anwendung der Nahinfrarotspektroskopie (NIRS) als Verfahren der zweiten Wahl empfohlen, wobei keine allgemein akzeptierten Grenzwerte für eine Shunt-Einlage vorliegen. Motorisch evozierte Potenziale sollten bei Operationen an der thorakalen Aorta descendens abgeleitet werden. Die beteiligten Gesellschaften sprechen sich für den Einsatz von NIRS zur Erkennung einer fehlerhaften Kanülenlage bei der Korrektur angeborener Herzfehler im Kindesalter sowie bei Operationen am Aortenbogen bei Kindern und Erwachsenen aus. Im Sinne einer Expertenmeinung wird die Anwendung von NIRS empfohlen bei Patienten mit stattgehabtem Apoplex, schwerer arterieller Hypertonie, hochgradigen Karotisstenosen sowie bei Herz- oder Lungentransplantationen.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE The aim of the present study was to evaluate a dose reduction in contrast-enhanced chest computed tomography (CT) by comparing the three latest generations of Siemens CT scanners used in clinical practice. We analyzed the amount of radiation used with filtered back projection (FBP) and an iterative reconstruction (IR) algorithm to yield the same image quality. Furthermore, the influence on the radiation dose of the most recent integrated circuit detector (ICD; Stellar detector, Siemens Healthcare, Erlangen, Germany) was investigated. MATERIALS AND METHODS 136 Patients were included. Scan parameters were set to a thorax routine: SOMATOM Sensation 64 (FBP), SOMATOM Definition Flash (IR), and SOMATOM Definition Edge (ICD and IR). Tube current was set constantly to the reference level of 100 mA automated tube current modulation using reference milliamperes. Care kV was used on the Flash and Edge scanner, while tube potential was individually selected between 100 and 140 kVp by the medical technologists at the SOMATOM Sensation. Quality assessment was performed on soft-tissue kernel reconstruction. Dose was represented by the dose length product. RESULTS Dose-length product (DLP) with FBP for the average chest CT was 308 mGy*cm ± 99.6. In contrast, the DLP for the chest CT with IR algorithm was 196.8 mGy*cm ± 68.8 (P = 0.0001). Further decline in dose can be noted with IR and the ICD: DLP: 166.4 mGy*cm ± 54.5 (P = 0.033). The dose reduction compared to FBP was 36.1% with IR and 45.6% with IR/ICD. Signal-to-noise ratio (SNR) was favorable in the aorta, bone, and soft tissue for IR/ICD in combination compared to FBP (the P values ranged from 0.003 to 0.048). Overall contrast-to-noise ratio (CNR) improved with declining DLP. CONCLUSION The most recent technical developments, namely IR in combination with integrated circuit detectors, can significantly lower radiation dose in chest CT examinations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Scoring schemes for clinical, ultrasonographic and radiographic findings in pigs were developed based upon a standardized animal model for Actinobacillus pleuropneumoniae infection.The results of these methods were compared to each other as well as with the corresponding pathomorphological findings during necropsy. Altogether 69 pigs of different breeding lines (Hampshire, Pietrain and German Landrace were examined. Positive correlations were found between the results of all three methods as well as with the necropsy scores (p <0.0001). Different pathomorphological findings were detected either by radiographic or by ultrasonographic examination dependent upon the type of lung tissue alterations: Alterations of the pleura as well as sequestration of lung tissue on the lung surface could be clearly identified during the ultrasonographic examination while deep tissue alterations with no contact to the lung surface could be detected reliably by radiographic examination. Both methods complement each other, and the application of a combined ultrasonographic and radiographic examination of the thorax allows a comprehensive inspection of the lung condition. Particularly during the acute phase of the disease the extent of lung tissue damage can be estimated more precisely than by clinical examination alone.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Steamer accidents, through contact with the bucket wheel, are very seldom today. No publication of such a kind of fatal accident could be found in literature. We present the case of a fatal steamer accident, in which the findings of a blunt traumatization of a person by the ship was completely documented by post-mortem combined multi-slice computed tomography (MSCT) and magnetic resonance imaging (MRI) examinations. A rupture of the aorta was detected using both radiological methods without use of radiopaque material. Radiological examination revealed a comminuted fracture of the thorax vertebrae at the same level as the aortic rupture. Injuries of the soft tissues of the back, caused by the bucket wheel of the steamer, were also diagnosed. In addition to the signs of blunt force trauma the findings of drowning such as an over inflation of the lungs, fluid in the stomach and duodenum were revealed. Furthermore, algological analysis detected diatoms in the lung tissue and blood from the left heart. Therefore, the cause of death was considered being a combination of fatal hemorrhage, caused by the aortic rupture, and drowning. We conclude that virtual autopsy using combined post-mortem MSCT and MRI is a useful tool for documentation, visualisation and analysis of the findings of blunt force trauma and drowning with a large potential in forensic medicine.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Venous air embolism (VAE) is an often occurring forensic finding in cases of injury to the head and neck. Whenever found, it has to be appraised in its relation to the cause of death. While visualization and quantification is difficult at traditional autopsy, Magnetic Resonance Imaging (MRI) and Computed Tomography (CT) offer a new potential in the diagnosis of VAE. This paper reports the findings of VAE in four cases of massive head injury examined postmortem by Multislice Computed Tomography (MSCT) prior to autopsy. MSCT data of the thorax were processed using 3D air structure reconstruction software to visualize air embolism within the vascular system. Quantification of VAE was done by multiplying air containing areas on axial 2D images by their reconstruction intervals and then by summarizing the air volumes. Excellent 3D visualization of the air within the vascular system was obtained in all cases, and the intravascular gas volume was quantified.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION For ultrasonographic diagnosis of a fetal trisomy so-called "soft markers" (=ultrasonographically detectable morphological variants) are used. Detection of a certain number of them increases the diagnostic certainty of a fetal trisomy. Up to now there are very few diagnostically accepted osseous soft markers for trisomy. Hence potential osseous soft markers applicable for first and second trimester ultrasound screening for trisomy 21, 18 or 13 were studied. METHODS Postmortal fetal X-rays (ap, lateral) of 358 fetuses (trisomy 21: n = 109, trisomy 18: n = 46; trisomy 13: n = 38, control group: n = 165). RESULTS Not yet described but with trisomy 21 statistically associated soft markers were un-timely os sternale ossification, delayed os sacrum ossification, shortened os maxillare, reduced os maxillare-jaw-corner distance, augmented orbita height, premature os calcaneus ossification, bell-shaped thorax, coronal clefts, trend to wider binocular as well as wider intraocular distances; for trisomy 18: elevated clavicula slope, reduced number of ribs, bell-shaped thorax, coronal clefts, reduced os maxillare-jaw-corner distance, shortened ramus mandibulare, shortened os metacarpale IV and V, augmented ratio between biparietal diameter and (osseus and soft-tissue) shoulder width; for trisomy 13: longer os nasale, elevated clavicula slope, premature sternum, delayed os sacrum ossification, delayed/premature cranium ossification, reduced number of ribs, coronal clefts, reduced os maxillare-jaw-corner distance, shortened ramus mandibulare, augmented orbita height, shortened os metacarpale V and a tendency for a shortened os metacarpale IV. CONCLUSION We found several not yet published osseous soft markers statistically associated with trisomy 21, 18 and 13, which can help to ensure sonographically these aneuploidy diagnoses.