186 resultados para Swan Ganz catheter


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate a widely used nontunneled triple-lumen central venous catheter in order to determine whether the largest of the three lumina (16 gauge) can tolerate high flow rates, such as those required for computed tomographic angiography. MATERIALS AND METHODS: Forty-two catheters were tested in vitro, including 10 new and 32 used catheters (median indwelling time, 5 days). Injection pressures were continuously monitored at the site of the 16-gauge central venous catheter hub. Catheters were injected with 300 and 370 mg of iodine per milliliter of iopamidol by using a mechanical injector at increasing flow rates until the catheter failed. The infusion rate, hub pressure, and location were documented for each failure event. The catheter pressures generated during hand injection by five operators were also analyzed. Mean flow rates and pressures at failure were compared by means of two-tailed Student t test, with differences considered significant at P < .05. RESULTS: Injections of iopamidol with 370 mg of iodine per milliliter generate more pressure than injections of iopamidol with 300 mg of iodine per milliliter at the same injection rate. All catheters failed in the tubing external to the patient. The lowest flow rate at which catheter failure occurred was 9 mL/sec. The lowest hub pressure at failure was 262 pounds per square inch gauge (psig) for new and 213 psig for used catheters. Hand injection of iopamidol with 300 mg of iodine per milliliter generated peak hub pressures ranging from 35 to 72 psig, corresponding to flow rates ranging from 2.5 to 5.0 mL/sec. CONCLUSION: Indwelling use has an effect on catheter material property, but even for used catheters there is a substantial safety margin for power injection with the particular triple-lumen central venous catheter tested in this study, as the manufacturer's recommendation for maximum pressure is 15 psig.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aims to evaluate whether visualization and integration of the computed tomography (CT) scan of the left atrium (LA) and the esophagus into the three-dimensional (3D) electroanatomical map the day before ablation is accurate compared with integration of an esophagus tag into the electroanatomic LA map visualizing the anatomic relationship during the radiofrequency ablation or whether esophagus movement prohibits esophagus visualization the day before ablation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the case of a patient in whom successful radiofrequency catheter ablation of an idiopathic ventricular tachycardia (VT) originating in the main stem of the pulmonary artery was performed. After successful ablation of the index arrhythmia, which was an idiopathic right ventricular outflow tract VT, a second VT with a different QRS morphology was reproducibly induced. Mapping of the second VT revealed the presence of myocardium approximately 2 cm above the pulmonary valve. Application of radiofrequency energy at this site resulted in termination and noninducibility of this VT. After 6-month follow-up, the patient remained free from VT recurrences.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND -Cardiac tamponade is the most dramatic complication observed during atrial fibrillation (AF) ablation and the leading cause of procedure-related mortality. Female gender is a known risk factor for complications during AF ablation; however, it is unknown whether women have a higher risk of tamponade. METHODS AND RESULTS -A systematic Medline search was used to locate academic electrophysiologic (EP) centers that reported cases of tamponade occurring during AF ablation. Centers were asked to provide information on cases of acute tamponade according to gender and their mode of management including any case of related mortality. Nineteen EP centers provided information on 34,943 ablation procedures involving 25,261 (72%) males. Overall 289 (0.9%) cases of tamponade were reported: 120 (1.24%) in females and 169 (0.67%) in males (odds ratio 1.83, P<0.001). There was a reciprocal association between center volume and the occurrence of tamponade with substantial lower risk in high volume centers. Most cases of tamponade occurred during catheter manipulation or ablation; females tended to develop more tamponades during transseptal catheterization. No gender difference in the mode of management was observed. However, 16% cases of tamponade required surgery with lower rates in high volume centers. Three cases of tamponade (1%) culminated in death. CONCLUSIONS -Tamponade during AF ablation procedures is relatively rare. Women have an almost twofold higher risk for developing this complication. The risk of tamponade among women decreases substantially in high volume centers. Surgical back-up and acute management skills for treating tamponade are important in centers performing AF ablation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Antiarrhythmic drugs are used in at least 50% of patients who received an implantable cardioverter defibrillator (ICD). The potential indications for antiarrhythmic drug treatments in patients with an ICD are generally the following: reduction of the number of ventricular tachycardias (VTs) or episodes of ventricular fibrillation and therefore reduction of the number of ICD therapies, most importantly, the number of disabling ICD shocks. Accordingly, the quality of life should be improved and the battery life of the ICD extended. Moreover, antiarrhythmic drugs have the potential to increase the tachycardia cycle length to allow termination of VTs by antitachycardia pacing and reduction of the number of syncopes. In addition, supraventricular arrhythmias can be prevented or their rate controlled. Recently published or reported trials have shown the efficacy of amiodarone, sotalol and azimilide to significantly reduce the number of appropriate and inappropriate ICD shocks in patients with structural heart disease. However, the use of antiarrhythmic drugs may also have adverse effects: an increase in the defibrillation threshold, an excessive increase in the VT cycle length leading to detection failure. In this situation and when antiarrhythmic drugs are ineffective or have to be stopped because of serious side effects, catheter ablation of both monomorphic stable and pleomorphic and/or unstable VTs using modern electroanatomic mapping systems should be considered. The choice of antiarrhythmic drug treatment and the need for catheter ablation in ICD patients with frequent VTs should be individually tailored to specific clinical and electrophysiological features including the frequency, the rate, and the clinical presentation of the ventricular arrhythmia. Although VT mapping and ablation is becoming increasingly practical and efficacious, ablation of VT is mostly done as an adjunctive therapy in patients with structural heart disease and ICD experiencing multiple shocks, because the recurrence and especially the occurrence of "new" VTs after primarily successful ablation with time and disease progression have precluded a widespread use of catheter ablation as primary treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND The objective of this study was to assess the incidence and impact of asymptomatic arrhythmia in patients with highly symptomatic atrial fibrillation (AF) who qualified for radiofrequency (RF) catheter ablation. METHODS AND RESULTS In this prospective study, 114 patients with at least 3 documented AF episodes together with corresponding symptoms and an ineffective trial of at least 1 antiarrhythmic drug were selected for RF ablation. With the use of CARTO, circumferential lesions around the pulmonary veins and linear lesions at the roof of the left atrium and along the left atrial isthmus were placed. A continuous, 7-day, Holter session was recorded before ablation, right after ablation, and after 3, 6, and 12 months of follow-up. During each 7-day Holter monitoring, the patients recorded quality and duration of any complaints by using a detailed symptom log. More than 70,000 hours of ECG recording were analyzed. In the 7-day Holter records before ablation, 92 of 114 patients (81%) had documented AF episodes. All episodes were symptomatic in 35 patients (38%). In 52 patients (57%), both symptomatic and asymptomatic episodes were recorded, whereas in 5 patients (5%), all documented AF episodes were asymptomatic. After ablation, the percentage of patients with only asymptomatic AF recurrences increased to 37% (P<0.05) at the 6-month follow-up. An analysis of patient characteristics and arrhythmia patterns failed to identify a specific subset who were at high risk for the development of asymptomatic AF. CONCLUSIONS Even in patients presenting with highly symptomatic AF, asymptomatic episodes may occur and significantly increase after catheter ablation. A symptom-only-based follow-up would substantially overestimate the success rate. Objective measures such as long-term Holter monitoring are needed to identify asymptomatic AF recurrences after ablation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES The aim of this study was to evaluate irrigated-tip catheter for ablation of intraatrial reentrant tachycardias late after surgical repair of congenital heart disease. BACKGROUND In congenital heart disease patients, the right atrium can be markedly enlarged with areas of low blood flow. Radiofrequency (RF) lesion creation may be hampered by insufficient electrode cooling at sites with low blood flow. METHODS Thirty-six consecutive patients with intraatrial reentrant tachycardia refractory to antiarrhythmic therapy from two centers were included in the study. Entrainment pacing and electroanatomic mapping (CARTO) were used to delineate reentrant circuits and critical isthmus sites. RF ablation was performed using an irrigated-tip catheter (Navistar Thermocool). RESULTS Fifty-two intraatrial reentrant tachycardia circuits were identified, and 48 were targeted with RF ablation. RF ablation was performed using a mean of 13 +/- 11 irrigated RF applications per tachycardia isthmus with a mean power of 36 +/- 8 W. In a historical control group of congenital heart disease patients managed with conventional catheter ablation, the number of lesions per isthmus was higher (23 +/- 11) and mean power was lower (27 +/- 14 W). Acute success was achieved in 45 intraatrial reentrant tachycardias (94% of targeted tachycardias and 87% of all tachycardias). After a mean follow-up of 17 +/- 7 months, 33 (92%) of 36 patients were free of recurrence. Five patients (14%) developed paroxysmal atrial fibrillation. CONCLUSIONS The combination of modern techniques including electroanatomic mapping and catheter irrigation allows safe and highly effective ablation of intraatrial reentrant tachycardia in patients with surgically repaired congenital heart disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electroanatomic mapping system Carto((R)) with its combination of anatomic and electrophysiologic information has substantially improved our understanding of arrhythmia mechanisms and substrates in patients with ventricular tachycardia (VT) and structural heart disease. Identification of the individual arrhythmogenic substrate and successful ablation guided by the combination of sinus rhythm voltage mapping and conventional electrophysiologic techniques like pace and activation/entrainment mapping are best described for patients with recurrent VT in remote myocardial infarction. In about 75-90% of the patients, the target VT can be ablated with acute success and the patients remain free of any VT recurrence in up to 75%. First results of electroanatomically guided ablation in patients with arrhythmogenic right ventricular dysplasia are promising. Data on ablation of VT in other structural heart diseases are very limited, since the arrhythmogenic substrate is very diffuse, e. g., in dilated cardiomyopathy, or there are only small patient numbers, e. g., for cardiac sarcoidosis or monomorphic VT after repair of congenital heart disease. In this article, the current status of electroanatomically guided endocardial mapping and ablation of VT in patients with structural heart disease is described.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION Catheter ablation for idiopathic ventricular arrhythmia is well established but epicardial origin, proximity to coronary arteries, and limited accessibility may complicate ablation from the venous system in particular from the great cardiac vein (GCV). METHODS Between April 2009 and October 2010 14 patients (56 ± 15 years; 9 male) out of a total group of 117 patients with idiopathic outflow tract tachycardias were included undergoing ablation for idiopathic VT or premature ventricular contractions (PVC) originating from GCV. All patients in whom the PVC arose from the GCV were subject to the study. In these patients angiography of the left coronary system was performed with the ablation catheter at the site of earliest activation. RESULTS Successful ablation was performed in 6/14 (43%) and long-term success was achieved in 5/14 (36%) patients. In 4/14 patients (28.6%) ablation was not performed. In another 4 patients (26.7%), ablation did not abolish the PVC/VT. In the majority, the anatomical proximity to the left coronary system prohibited effective RF application. In 3 patients RF application resulted in a coronary spasm with complete regression as revealed in repeat coronary angiography. CONCLUSION A relevant proportion idiopathic VT/PVC can safely be ablated from the GCV without significant permanent coronary artery stenosis after RF application. Our data furthermore demonstrate that damage to the coronary artery system is likely to be transient.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Catheter ablation for paroxysmal atrial fibrillation is a meanwhile established therapy option, which is most frequently performed using radiofrequency ablation. Mid-term success rate of 70 % are achievable with a single ablation procedure. However, the mechanistics of persistent atrial fibrillation are less well understood and catheter ablation is a far more challenging procedure. Different ablation approaches are being performed to treat persistent atrial fibrillation ranging from sole pulmonary vein isolation to additional ablation of fractionated electrograms aiming for termination of atrial fibrillation. Thus far, it has not been investigated which strategy is most successful in treating persistent atrial fibrillation. After extended ablation of atrial fibrillation, occurrence of organized atrial arrhythmias is not uncommon and can be successfully ablated. These consecutive arrhythmias can be considered as a next step towards stable sinus rhythm after repeat ablation. Improvement of mapping methods as well as a better understanding of mechanisms of atrial fibrillation may increase success rate of catheter ablation of persistent atrial fibrillation and may also help to improve success rate of these complex procedures.