364 resultados para Surgical flap grafts
Resumo:
Major efforts have been undertaken to reduce donor-site morbidity after abdominal flaps, which eventually culminated in the introduction of the deep inferior epigastric perforator (DIEP) flap. However, due to anatomical variations (absence of dominant perforators) and the risk of ischaemic complications, the selection of patients qualifying for a DIEP flap is limited. Furthermore, DIEP flaps can only be used as free flaps. We present our long-term experience with a dissection technique of rectus abdominis myocutaneous (RAM) flaps that was developed to circumvent these drawbacks. The dissection is characterised by preventing to sacrifice any perforators nourishing the flap and by fully preserving the anterior rectus sheath, but not the muscle. The study comprises a consecutive series of prospectively assessed patients, treated between February 2000 and April 2008. A total of 100 fascia-sparing RAM flaps were operated on 97 patients (age 22-84 years, median 64 years). Free flaps were mainly used for breast reconstruction (47 flaps/24 patients), and cranially (34) or caudally (19) pedicled flaps for soft-tissue coverage after sternectomy, urogenital tumour resection or rectum amputation. Eighty patients had a total of 213 risk factors, such as cardiovascular diseases, obesity, hyperlipidaemia, diabetes mellitus, smoking or steroid medication. Partial tissue loss (skin or fat necrosis) occurred in 13 flaps, out of which seven required surgical revision. The ischaemic complications were evenly distributed between the patient subsets. At a follow-up of 2-89 months (median 20 months), one patient showed a flap harvest-related abdominal bulge after bilateral-free transverse rectus abdominis myocutaneous (TRAM) flap. We conclude that the present dissection technique provides maximal perforator-related perfusion and minimal donor-site morbidity even in pedicled flaps and high-risk patients. In free flaps, it may, therefore, be recommended as an alternative to the DIEP flap.
Resumo:
The authors present the long-term results in a series of 44 cases with post-traumatic bone defects solved with muscle-rib flaps, between March 1997 and December 2007. In these cases, we performed 21 serratus anterior-rib flaps (SA-R), 10 latissimus dorsi-rib flaps (LD-R), and 13 LD-SA-R. The flaps were used in upper limb in 18 cases and in lower limb in 26 cases. With an overall immediate success rate of 95.4% (42 of 44 cases) and a primary bone union rate of 97.7% (43 of 44 cases), and despite the few partisans of this method, we consider that this procedure still remains very usefully for small and medium bone defects accompanied by large soft tissue defects.
Resumo:
To present the auditory implant manipulator, a navigation-controlled mechanical and electronic system which enables minimally invasive ('keyhole') transmastoid access to the tympanic cavity.
Resumo:
The closing sounds of mechanical heart valves can be disturbing for patients and their closest relatives. Although some investigations into mechanical heart valve sounds have been performed, the particularities of the valve sound when it is attached to a vascular prosthesis to replace the aortic root and the ascending aorta has not been studied to date. The study aim was to compare the closing sounds of three various mechanical composite graft prostheses, and to analyze the impact of such sounds on the patients' quality of life.
Resumo:
Approximately 20% of leg ulcers remain unresponsive to the best conservative standard of care. So far, these patients could either receive conventional skin grafts or had to accept their intractable wound. Skin substitutes from cell culture may represent a promising alternative to heal a major part of these patients on a non-surgical, potentially more cost-effective basis.
Resumo:
The incidence of ischemia might be increased in the surgical repair of atherosclerotic unruptured aneurysms compared to non-atherosclerotic aneurysms. The atherosclerotic wall might increase the occurrence of thrombembolic events or its rigidity might endanger the occlusion of perforators within the aneurysm vicinity.
Resumo:
The aim of this study is to review the results and clinical outcome of patients with surgically treated lesions within the trigone of the lateral ventricle. This is a retrospective case series of 20 (eight male, 12 female) patients with lesions of the trigone of the lateral ventricle operated between 1998 and 2008. All lesions were removed via the transcortical temporal and transcortical parietal route. Surgical complications and outcome were assessed using the modified Rankin Scale (mRS). There were four children and 16 adults with a mean age of 42?±?22 years (min?=?1, max?=?74). Eight (40%) lesions grew within the trigone of the dominant hemisphere. In 17 cases, the lesion was purely intraventricular, and in three cases, a slight paraventricular extension was seen. The mean size was 4.5 cm of maximal diameter. Surgical removal was achieved via the transcortical parietal route in 13 cases (65%) and the transcortical temporal route in seven cases (35%). In all cases, complete resection was possible. According to the mRS, 13 patients improved, five remained the same, and two were lost to follow-up. One patient had an increased visual field deficit postoperatively and new hemiparesis and aphasia, but returned to the preoperative level within a few weeks. In one patient, an acute myocardial infarction occurred due to previous cardiac stent placement and in-stent stenosis. Even large trigonal lesions can be resected with low morbidity using a transcortical approach depending on the peritrigonal extension of the tumor.
Resumo:
The spine is a complex structure that provides motion in three directions: flexion and extension, lateral bending and axial rotation. So far, the investigation of the mechanical and kinematic behavior of the basic unit of the spine, a motion segment, is predominantly a domain of in vitro experiments on spinal loading simulators. Most existing approaches to measure spinal stiffness intraoperatively in an in vivo environment use a distractor. However, these concepts usually assume a planar loading and motion. The objective of our study was to develop and validate an apparatus, that allows to perform intraoperative in vivo measurements to determine both the applied force and the resulting motion in three dimensional space. The proposed setup combines force measurement with an instrumented distractor and motion tracking with an optoelectronic system. As the orientation of the applied force and the three dimensional motion is known, not only force-displacement, but also moment-angle relations could be determined. The validation was performed using three cadaveric lumbar ovine spines. The lateral bending stiffness of two motion segments per specimen was determined with the proposed concept and compared with the stiffness acquired on a spinal loading simulator which was considered to be gold standard. The mean values of the stiffness computed with the proposed concept were within a range of ±15% compared to data obtained with the spinal loading simulator under applied loads of less than 5 Nm.
Resumo:
Endovascular stent grafting represents a novel concept for type B aortic dissection both in the acute and subacute/chronic setting, with an unknown effect on outcomes.