51 resultados para Spearman, Clint
Resumo:
BACKGROUND The correlation between noninvasive markers with endoscopic activity according to the modified Baron Index in patients with ulcerative colitis (UC) is unknown. We aimed to evaluate the correlation between endoscopic activity and fecal calprotectin (FC), C-reactive protein (CRP), hemoglobin, platelets, blood leukocytes, and the Lichtiger Index (clinical score). METHODS UC patients undergoing complete colonoscopy were prospectively enrolled and scored clinically and endoscopically. Samples from feces and blood were analyzed in UC patients and controls. RESULTS We enrolled 228 UC patients and 52 healthy controls. Endoscopic disease activity correlated best with FC (Spearman's rank correlation coefficient r = 0.821), followed by the Lichtiger Index (r = 0.682), CRP (r = 0.556), platelets (r = 0.488), blood leukocytes (r = 0.401), and hemoglobin (r = -0.388). FC was the only marker that could discriminate between different grades of endoscopic activity (grade 0, 16 [10-30] μg/g; grade 1, 35 [25-48] μg/g; grade 2, 102 [44-159] μg/g; grade 3, 235 [176-319] μg/g; grade 4, 611 [406-868] μg/g; P < 0.001 for discriminating the different grades). FC with a cutoff of 57 μg/g had a sensitivity of 91% and a specificity of 90% to detect endoscopically active disease (modified Baron Index ≥ 2). CONCLUSIONS FC correlated better with endoscopic disease activity than clinical activity, CRP, platelets, hemoglobin, and blood leukocytes. The strong correlation with endoscopic disease activity suggests that FC represents a useful biomarker for noninvasive monitoring of disease activity in UC patients.
Resumo:
This study aimed to assess the performance of International Caries Detection and Assessment System (ICDAS), radiographic examination, and fluorescence-based methods for detecting occlusal caries in primary teeth. One occlusal site on each of 79 primary molars was assessed twice by two examiners using ICDAS, bitewing radiography (BW), DIAGNOdent 2095 (LF), DIAGNOdent 2190 (LFpen), and VistaProof fluorescence camera (FC). The teeth were histologically prepared and assessed for caries extent. Optimal cutoff limits were calculated for LF, LFpen, and FC. At the D (1) threshold (enamel and dentin lesions), ICDAS and FC presented higher sensitivity values (0.75 and 0.73, respectively), while BW showed higher specificity (1.00). At the D (2) threshold (inner enamel and dentin lesions), ICDAS presented higher sensitivity (0.83) and statistically significantly lower specificity (0.70). At the D(3) threshold (dentin lesions), LFpen and FC showed higher sensitivity (1.00 and 0.91, respectively), while higher specificity was presented by FC (0.95), ICDAS (0.94), BW (0.94), and LF (0.92). The area under the receiver operating characteristic (ROC) curve (Az) varied from 0.780 (BW) to 0.941 (LF). Spearman correlation coefficients with histology were 0.72 (ICDAS), 0.64 (BW), 0.71 (LF), 0.65 (LFpen), and 0.74 (FC). Inter- and intraexaminer intraclass correlation values varied from 0.772 to 0.963 and unweighted kappa values ranged from 0.462 to 0.750. In conclusion, ICDAS and FC exhibited better accuracy in detecting enamel and dentin caries lesions, whereas ICDAS, LF, LFpen, and FC were more appropriate for detecting dentin lesions on occlusal surfaces in primary teeth, with no statistically significant difference among them. All methods presented good to excellent reproducibility.
Resumo:
The purpose of this study was to compare the validity and output of the biaxial ActiGraph GT1M and the triaxial GT3X (ActiGraph, LLC, Pensacola, FL, USA)accelerometer in 5- to 9-year-old children. Thirty-two children wore the two monitors while their energy expenditure was measured with indirect calorimetry. They performed four locomotor and four play activities in an exercise laboratory and were further measured during 12 minutes of a sports lesson. Validity evidence in relation to indirect calorimetry was examined with linear regression equations applied to the laboratory data. During the sports lessons predicted energy expenditure according to the regression equations was compared to measured energy expenditure with the Wilcoxon-signed rank test and the Spearman correlation. To compare the output, agreement between counts of the two monitors during the laboratory activities was assessed with Bland-Altman plots. The evidence of validity was similar for both monitors. Agreement between the output of the two monitors was good for vertical counts (mean bias = −14 ± 22 counts) but not for horizontal counts (−17 ± 32 counts). The current results indicate that the two accelerometer models are able to estimate energy expenditure of a range of physical activities equally well in young children. However, they show output differences for movement in the horizontal direction.
Resumo:
PURPOSE The ironman (IM) triathlon is a popular ultraendurance competition, consisting of 3.8 km of swimming, 180.2 km of cycling, and 42.2 km of running. The aim of this study was to investigate the predictors of IM race time, comparing echocardiographic findings, anthropometric measures, and training characteristics. METHODS Amateur IM athletes (ATHL) participating in the Zurich IM race in 2010 were included. Participants were examined the day before the race by a comprehensive echocardiographic examination. Moreover, anthropometric measurements were obtained the same day. During the 3 months before the race, each IM-ATHL maintained a detailed training diary. Recorded data were related to total IM race time. RESULTS Thirty-eight IM finishers (mean ± SD age = 38 ± 9 yr, 32 men [84%]) were evaluated. Total race time was 684 ± 89 min (mean ± SD). For right ventricular fractional area change (45% ± 7%, Spearman ρ = -0.33, P = 0.05), a weak correlation with race time was observed. Race performance exhibited stronger associations with percent body fat (15.2 ± 5.6%, ρ = 0.56, P = 0.001), speed in running training (11.7 ± 1.2 km · h(-1), ρ = -0.52, P = 0.002), and left ventricular myocardial mass index (98 ± 24 g · m(-2), ρ = -0.42, P = 0.009). The strongest association was found between race time and right ventricular end-diastolic area (22 ± 4 cm2, ρ = -0.64, P < 0.0001). In multivariate analysis, right ventricular end-diastolic area (β = -16.7, 95% confidence interval = -27.3 to -6.1, P = 0.003) and percent body fat (β = 6.8, 95% confidence interval = 1.1-12.6, P = 0.02) were independently predictive of IM race time. CONCLUSIONS In amateur IM-ATHL, RV end-diastolic area and percent body fat were independently related to race performance. RV end-diastolic area was the strongest predictor of race time. The role of the RV in endurance exercise may thus be more important than previously thought and needs to be further studied.
Resumo:
BACKGROUND Vigorous sporting activity during the growth years is associated with an increased risk of having a cam-type deformity develop. The underlying cause of this osseous deformity is unclear. One may speculate whether this is caused by reactive bone apposition in the region of the anterosuperior head-neck junction or whether sports activity alters the shape of and growth in the growth plate. If the latter is true, then one would expect athletes to show an abnormal shape of the capital growth plate (specifically, the epiphyseal extension) before and/or after physeal closure. QUESTIONS/PURPOSES We therefore raised three questions: (1) Do adolescent basketball players show abnormal epiphyseal extension? (2) Does the epiphyseal extension differ before and after physeal closure? (3) Is abnormal epiphyseal extension associated with high alpha angles? METHODS We performed a case-control comparative analysis of young (age range, 9-22 years) male elite basketball athletes with age-matched nonathletes, substratified by whether they had open or closed physes. We measured epiphyseal extension on radial-sequence MRI cuts throughout the cranial hemisphere from 9 o'clock (posterior) to 3 o'clock (anterior). Epiphyseal extension was correlated to alpha angle measurements at the same points. RESULTS Epiphyseal extension was increased in all positions in the athletes compared with the control group. On average, athletes showed epiphyseal extension of 0.67 to 0.83 versus 0.53 to 0.71 in control subjects. In the control group epiphyseal extension was increased at all measurement points in hips after physeal closure compared with before physeal closure. In contrast, the subgroup of athletes with a closed growth plate only had increased epiphyseal extension at the 3 o'clock position compared with the athletes with an open [corrected] growth plate (0.64-0.70). We observed a correlation between an alpha angle greater than 55° and greater epiphyseal extension in the anterosuperior femoral head quadrant: the corresponding Spearman r values were 0.387 (all hips) and 0.285 (alpha angle>55°) for the aggregate anterosuperior quadrant. CONCLUSIONS These findings suggest that a cam-type abnormality in athletes is a consequence of an alteration of the growth plate rather than reactive bone formation. High-level sports activity during growth may be a new and distinct risk factor for a cam-type deformity.
Resumo:
This study aimed to evaluate whether equine serum amyloid A (SAA) concentrations could be reliably measured in plasma with a turbidimetric immunoassay previously validated for equine SAA concentrations in serum. Paired serum and lithium-heparin samples obtained from 40 horses were evaluated. No difference was found in SAA concentrations between serum and plasma using a paired t test (P=0.48). The correlation between paired samples was 0.97 (Spearman's rank P<0.0001; 95% confidence interval 0.95-0.99). Passing-Bablok regression analyses revealed no differences between paired samples. Bland-Altman plots revealed a positive bias in plasma compared to serum but the difference was not considered clinically significant. The results indicate that lithium-heparin plasma samples are suitable for measurement of equine SAA using this method. Use of either serum or plasma allows for greater flexibility when it comes to sample collection although care should be taken when comparing data between measurements from different sample types.