74 resultados para Simplified procedure
Resumo:
Abstract Radiation metabolomics employing mass spectral technologies represents a plausible means of high-throughput minimally invasive radiation biodosimetry. A simplified metabolomics protocol is described that employs ubiquitous gas chromatography-mass spectrometry and open source software including random forests machine learning algorithm to uncover latent biomarkers of 3 Gy gamma radiation in rats. Urine was collected from six male Wistar rats and six sham-irradiated controls for 7 days, 4 prior to irradiation and 3 after irradiation. Water and food consumption, urine volume, body weight, and sodium, potassium, calcium, chloride, phosphate and urea excretion showed major effects from exposure to gamma radiation. The metabolomics protocol uncovered several urinary metabolites that were significantly up-regulated (glyoxylate, threonate, thymine, uracil, p-cresol) and down-regulated (citrate, 2-oxoglutarate, adipate, pimelate, suberate, azelaate) as a result of radiation exposure. Thymine and uracil were shown to derive largely from thymidine and 2'-deoxyuridine, which are known radiation biomarkers in the mouse. The radiation metabolomic phenotype in rats appeared to derive from oxidative stress and effects on kidney function. Gas chromatography-mass spectrometry is a promising platform on which to develop the field of radiation metabolomics further and to assist in the design of instrumentation for use in detecting biological consequences of environmental radiation release.
Resumo:
BACKGROUND: Phaeochromocytomas and paragangliomas are neuro-endocrine tumours that occur sporadically and in several hereditary tumour syndromes, including the phaeochromocytoma-paraganglioma syndrome. This syndrome is caused by germline mutations in succinate dehydrogenase B (SDHB), C (SDHC), or D (SDHD) genes. Clinically, the phaeochromocytoma-paraganglioma syndrome is often unrecognised, although 10-30% of apparently sporadic phaeochromocytomas and paragangliomas harbour germline SDH-gene mutations. Despite these figures, the screening of phaeochromocytomas and paragangliomas for mutations in the SDH genes to detect phaeochromocytoma-paraganglioma syndrome is rarely done because of time and financial constraints. We investigated whether SDHB immunohistochemistry could effectively discriminate between SDH-related and non-SDH-related phaeochromocytomas and paragangliomas in large retrospective and prospective tumour series. METHODS: Immunohistochemistry for SDHB was done on 220 tumours. Two retrospective series of 175 phaeochromocytomas and paragangliomas with known germline mutation status for phaeochromocytoma-susceptibility or paraganglioma-susceptibility genes were investigated. Additionally, a prospective series of 45 phaeochromocytomas and paragangliomas was investigated for SDHB immunostaining followed by SDHB, SDHC, and SDHD mutation testing. FINDINGS: SDHB protein expression was absent in all 102 phaeochromocytomas and paragangliomas with an SDHB, SDHC, or SDHD mutation, but was present in all 65 paraganglionic tumours related to multiple endocrine neoplasia type 2, von Hippel-Lindau disease, and neurofibromatosis type 1. 47 (89%) of the 53 phaeochromocytomas and paragangliomas with no syndromic germline mutation showed SDHB expression. The sensitivity and specificity of the SDHB immunohistochemistry to detect the presence of an SDH mutation in the prospective series were 100% (95% CI 87-100) and 84% (60-97), respectively. INTERPRETATION: Phaeochromocytoma-paraganglioma syndrome can be diagnosed reliably by an immunohistochemical procedure. SDHB, SDHC, and SDHD germline mutation testing is indicated only in patients with SDHB-negative tumours. SDHB immunohistochemistry on phaeochromocytomas and paragangliomas could improve the diagnosis of phaeochromocytoma-paraganglioma syndrome. FUNDING: The Netherlands Organisation for Scientific Research, Dutch Cancer Society, Vanderes Foundation, Association pour la Recherche contre le Cancer, Institut National de la Santé et de la Recherche Médicale, and a PHRC grant COMETE 3 for the COMETE network.
Resumo:
Transcatheter aortic valve replacement (TAVR) constitutes a relatively new treatment option for the patients with severe symptomatic aortic stenosis. Evidence from registries and randomized control trials has underscored the value of this treatment in inoperable and high risk populations, while new developments in valve technology and TAVR enabling devices have reduced the risk of complications, simplified the procedure, and broadened the applications of this therapy. The initial promising clinical results and the potential of an effective less invasive treatment of aortic stenosis has not only created high expectations but also the need to address the pitfalls of TAVR technology. The evolving knowledge concerning the groups of patients who would benefit from this treatment, the limited long term follow-up data, the concerns about devices' long term durability, and the severity of complications remain important caveats which restrict the widespread clinical adoption of TAVR. The aim of this review article is to present the recent advances, highlight the limitations of TAVR technology, and discuss the future perspectives in this rapidly evolving field.
Resumo:
PURPOSE To evaluate the bonding of simplified adhesive systems to sound and caries-affected dentin of primary teeth with microtensile (µTBS) and nanoleakage (NL) tests. MATERIALS AND METHODS Occlusal cavities were prepared in 36 sound second primary molars. Half of the specimens were submitted to pH cycling to simulate caries-affected dentin. Teeth were randomly restored with one of three materials: the etch-and-rinse adhesive system Adper Single Bond 2 (SB), the two-step self-etching adhesive system Adper SE Plus (SE), and the one-step self-etching adhesive system Adper Easy One (EASY). After storage for 24 h, specimens with cross-sectional areas of 0.8 mm2 were prepared for microtensile testing (1 mm/min). One stick from each tooth was immersed in silver nitrate solution (24 h) and allowed to develop for 8 h in order to score the nano leakage with SEM. The fracture pattern was evaluated using a stereomicroscope (400X). The µTBS means were analyzed by two-way ANOVA and Tukey's post-hoc test. For NL, the Kruskal- Wallis and Mann-Whitney tests were used (α < 0.05). RESULTS SB (35.5 ± 3.5) showed the highest µTBS value to sound dentin, followed by EASY (26.3 ± 1.9) and SE (18.2 ± 6.5) (p < 0.05). No difference among materials was observed for caries-affected dentin (SB: 17.8 ± 4.2; SE: 13.9 ± 3.2; EASY: 14.4 ± 4.2, p > 0.05). For all groups, adhesive/mixed fracture prevailed. Caries affected dentin promoted silver nitrate uptake into the adhesive interface; however, with SE, the nano leakage was more pronounced than in the other adhesive systems, even in sound dentin. CONCLUSION Caries-affected dentin negatively influences the bond strength and nano leakage of the two-step etch-and-rinse and one-step self-etching adhesive systems tested in primary teeth.
Resumo:
The issuance of the Swiss Federal Act on Collective Investment Schemes (CISA) in the year 2007 and the revision thereof in 2013 expanded the possibilities for restructuring of collective investment schemes and simplified the procedures. For instance, in article 95 the CISA contains a provision that deals in a non-conclusive way with the restructuring of open-ended collective investment schemes. As a novelty regulation, this provision allows for mergers not only of contractual funds but also of investment companies with variable capital (SICAV). Additionally, the transformation of an open-ended collective investment into another CISA legal form was also included into the catalogue of possible restructuring processes. Further, a SICAV still maintains the possibility for asset transfer according to article 69 ff. of the Federal Act on Merger, Demerger, Transformation and Transfer of Assets (MerA). However, not all open questions have been clarified. As long as the CISA does not contain restructuring provisions, as is the case with closed-ended collective investment schemes, generally the MerA and/or the Swiss Code of Obligations (CO) apply. The interplay of diverse, partly overlapping legislative bases leads to the emergence of unwanted gaps. Moreover, the partial revision of the CISA was not completely implemented at the ordinance level. Among others, the following issues have not been conclusively or clearly regulated: the permitted combinations of mergers, the merger procedure of the SICAV, the permitted restructurings, the transformation procedure as well as the application scope of the asset transfer for collective investment schemes according to the relevant merger regulations. Although these questions will be clarified in the following article through a systematic and teleological analysis of the relevant regulations, it is to be hoped that the gaps will be closed within the next CISA revision in order to guarantee comprehensive legal certainty.
Resumo:
Transcatheter aortic valve implantation (TAVI) is a novel therapy, which has transformed the management of inoperable patients presenting with symptomatic severe aortic stenosis (AS). It is also a proven and less invasive alternative therapeutic option for high-risk symptomatic patients presenting with severe AS who are otherwise eligible for surgical aortic valve replacement. Patient age is not strictly a limitation for TAVI but since this procedure is currently restricted to high-risk and inoperable patients, it follows that most patients selected for TAVI are at an advanced age. Patient frailty and co-morbidities need to be assessed and a clinical judgment made on whether the patient will gain a measureable improvement in their quality of life. Risk stratification has assumed a central role in selecting suitable patients and surgical risk algorithms have proven helpful in this regard. However, limitations exist with these risk models, which must be understood in the context of TAVI. When making final treatment decisions, it is essential that a collaborative multidisciplinary "heart team" be involved and this is stressed in the most recent guidelines of the European Society of Cardiology. Choosing the best procedure is contingent upon anatomical feasibility, and multimodality imaging has emerged as an integral component of the pre-interventional screening process in this regard. The transfemoral route is now considered the default approach although vascular complications remain a concern. A minimal vessel diameter of 6 mm is required for currently commercial available vascular introducer sheaths. Several alternative access routes are available to choose from when confronted with difficult iliofemoral anatomy such as severe peripheral vascular disease or diffuse circumferential vessel calcification. The degree of aortic valve leaflet and annular calcification also needs to be assessed as the latter is a risk factor for post-procedural paravalvular aortic regurgitation. The ultimate goal of patient selection is to achieve the highest procedural success rate while minimizing complications and to choose patients most likely to derive tangible benefit from this procedure.