64 resultados para SIMULATION OF ELECTRONIC DEVICES


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We consider a large quantum system with spins 12 whose dynamics is driven entirely by measurements of the total spin of spin pairs. This gives rise to a dissipative coupling to the environment. When one averages over the measurement results, the corresponding real-time path integral does not suffer from a sign problem. Using an efficient cluster algorithm, we study the real-time evolution from an initial antiferromagnetic state of the two-dimensional Heisenberg model, which is driven to a disordered phase, not by a Hamiltonian, but by sporadic measurements or by continuous Lindblad evolution.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Phase-sensitive X-ray imaging shows a high sensitivity towards electron density variations, making it well suited for imaging of soft tissue matter. However, there are still open questions about the details of the image formation process. Here, a framework for numerical simulations of phase-sensitive X-ray imaging is presented, which takes both particle- and wave-like properties of X-rays into consideration. A split approach is presented where we combine a Monte Carlo method (MC) based sample part with a wave optics simulation based propagation part, leading to a framework that takes both particle- and wave-like properties into account. The framework can be adapted to different phase-sensitive imaging methods and has been validated through comparisons with experiments for grating interferometry and propagation-based imaging. The validation of the framework shows that the combination of wave optics and MC has been successfully implemented and yields good agreement between measurements and simulations. This demonstrates that the physical processes relevant for developing a deeper understanding of scattering in the context of phase-sensitive imaging are modelled in a sufficiently accurate manner. The framework can be used for the simulation of phase-sensitive X-ray imaging, for instance for the simulation of grating interferometry or propagation-based imaging.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE To analyze the transit time from various locations in the intestines of cows with cecal dilatation-dislocation (CDD), healthy control cows, and cows with left displacement of the abomasum (LDA). ANIMALS 15 cows with naturally occurring CDD (group 1), 14 healthy control cows (group 2), and 18 cows with LDA (group 3). PROCEDURES 5 electronic transmitters were encased in capsules and placed in the lumen of the ileum, cecum, proximal portion of the colon, and 2 locations in the spiral colon (colon 1 and colon 2) and used to measure the transit time (ie, time between placement in the lumen and excretion of the capsules from the rectum). Excretion time of the capsules from each intestinal segment was compared among groups. RESULTS Cows recovered well from surgery, except for 1 cow with relapse of CDD 4 days after surgery and 2 cows with incisional infection. High variability in capsule excretion times was observed for all examined intestinal segments in all groups. Significant differences were detected for the excretion time from the colon (greater in cows with CDD than in healthy control cows) and cecum (less in cows with LDA than in cows of the other 2 groups). CONCLUSIONS AND CLINICAL RELEVANCE The technique developed to measure excretion time of capsules from bovine intestines was safe and reliable; however, the large variability observed for all intestinal segments and all groups would appear to be a limitation for its use in assessment of intestinal transit time of cattle in future studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cloud Computing has evolved to become an enabler for delivering access to large scale distributed applications running on managed network-connected computing systems. This makes possible hosting Distributed Enterprise Information Systems (dEISs) in cloud environments, while enforcing strict performance and quality of service requirements, defined using Service Level Agreements (SLAs). {SLAs} define the performance boundaries of distributed applications, and are enforced by a cloud management system (CMS) dynamically allocating the available computing resources to the cloud services. We present two novel VM-scaling algorithms focused on dEIS systems, which optimally detect most appropriate scaling conditions using performance-models of distributed applications derived from constant-workload benchmarks, together with SLA-specified performance constraints. We simulate the VM-scaling algorithms in a cloud simulator and compare against trace-based performance models of dEISs. We compare a total of three SLA-based VM-scaling algorithms (one using prediction mechanisms) based on a real-world application scenario involving a large variable number of users. Our results show that it is beneficial to use autoregressive predictive SLA-driven scaling algorithms in cloud management systems for guaranteeing performance invariants of distributed cloud applications, as opposed to using only reactive SLA-based VM-scaling algorithms.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

SUMMARY There is interest in the potential of companion animal surveillance to provide data to improve pet health and to provide early warning of environmental hazards to people. We implemented a companion animal surveillance system in Calgary, Alberta and the surrounding communities. Informatics technologies automatically extracted electronic medical records from participating veterinary practices and identified cases of enteric syndrome in the warehoused records. The data were analysed using time-series analyses and a retrospective space-time permutation scan statistic. We identified a seasonal pattern of reports of occurrences of enteric syndromes in companion animals and four statistically significant clusters of enteric syndrome cases. The cases within each cluster were examined and information about the animals involved (species, age, sex), their vaccination history, possible exposure or risk behaviour history, information about disease severity, and the aetiological diagnosis was collected. We then assessed whether the cases within the cluster were unusual and if they represented an animal or public health threat. There was often insufficient information recorded in the medical record to characterize the clusters by aetiology or exposures. Space-time analysis of companion animal enteric syndrome cases found evidence of clustering. Collection of more epidemiologically relevant data would enhance the utility of practice-based companion animal surveillance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Web surveys are becoming increasingly popular in survey research. Compared with face-to-face, telephone and mail surveys, web surveys may contain a different and new source of measurement error and bias: the type of device that respondents use to answer the survey questions. To the best of our knowledge, this is the first study that tests whether the use of mobile devices affects survey characteristics and stated preferences in a web-based choice experiment. The web survey was carried out in Germany with 3,400 respondents, of which 12 per cent used a mobile device (i.e. tablet or smartphone), and comprised a stated choice experiment on externalities of renewable energy production using wind, solar and biomass. Our main finding is that survey characteristics such as interview length and acquiescence tendency are affected by the device used. In contrast to what might be expected, we find that, compared with respondents using desktop computers and laptops, mobile device users spent more time to answer the survey and are less likely to be prone to acquiescence bias. In the choice experiment, mobile device users tended to be more consistent in their stated choices, and there are differences in willingness to pay between both subsamples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

One-dimensional dynamic computer simulation was employed to investigate the separation and migration order change of ketoconazole enantiomers at low pH in presence of increasing amounts of (2-hydroxypropyl)-β-cyclodextrin (OHP-β-CD). The 1:1 interaction of ketoconazole with the neutral cyclodextrin was simulated under real experimental conditions and by varying input parameters for complex mobilities and complexation constants. Simulation results obtained with experimentally determined apparent ionic mobilities, complex mobilities, and complexation constants were found to compare well with the calculated separation selectivity and experimental data. Simulation data revealed that the migration order of the ketoconazole enantiomers at low (OHP-β-CD) concentrations (i.e. below migration order inversion) is essentially determined by the difference in complexation constants and at high (OHP-β-CD) concentrations (i.e. above migration order inversion) by the difference in complex mobilities. Furthermore, simulations with complex mobilities set to zero provided data that mimic migration order and separation with the chiral selector being immobilized. For the studied CEC configuration, no migration order inversion is predicted and separations are shown to be quicker and electrophoretic transport reduced in comparison to migration in free solution. The presented data illustrate that dynamic computer simulation is a valuable tool to study electrokinetic migration and separations of enantiomers in presence of a complexing agent.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose. For accurate resection of nonpalpable malignant breast lesions with a tumor-free resection rim, an exact and stable wire localization is essential. We tested the resistance towards traction force of different localization devices used in our clinic for breast lesions in two types of tissue. Materials and Methods. Eight different commercially available hook-wire devices were examined for resistance towards traction force using an analogue spring scale. Results. Most systems showed a high level of movement already under small traction force. Retractable systems with round hooks such as the Bard DuaLok , the Fil d'Ariane, and the RPLN Breast Localization Device withstood less traction force than the other systems. However, the Bard DuaLok system was very resistant towards a small traction force of 50 g when compared to the other systems. The Ultrawire Breast Localization Device withstood the most traction force in softer tissue and Kopans Breast Lesion Localization Needle withstood the most force in harder tissue. Conclusion. The Ultrawire Breast Localization Device and Kopans Breast Lesion Localization Needle withstood the most traction force. In general retractable systems withstand less traction force than nonretractable systems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

XENON is a dark matter direct detection project, consisting of a time projection chamber (TPC) filled with liquid xenon as detection medium. The construction of the next generation detector, XENON1T, is presently taking place at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy. It aims at a sensitivity to spin-independent cross sections of 2 10-47 c 2 for WIMP masses around 50 GeV2, which requires a background reduction by two orders of magnitude compared to XENON100, the current generation detector. An active system that is able to tag muons and muon-induced backgrounds is critical for this goal. A water Cherenkov detector of ~ 10 m height and diameter has been therefore developed, equipped with 8 inch photomultipliers and cladded by a reflective foil. We present the design and optimization study for this detector, which has been carried out with a series of Monte Carlo simulations. The muon veto will reach very high detection efficiencies for muons (>99.5%) and showers of secondary particles from muon interactions in the rock (>70%). Similar efficiencies will be obtained for XENONnT, the upgrade of XENON1T, which will later improve the WIMP sensitivity by another order of magnitude. With the Cherenkov water shield studied here, the background from muon-induced neutrons in XENON1T is negligible.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A benchmark problem set consisting of four problem levels was developed for the simulation of Cr isotope fractionation in 1D and 2D domains. The benchmark is based on a recent field study where Cr(VI) reduction and accompanying Cr isotope fractionation occurs abiotically by an aqueous reaction with dissolved Fe 2+ (Wanner et al., 2012., Appl. Geochem., 27, 644–662). The problem set includes simulation of the major processes affecting the Cr isotopic composition such as the dissolution of various Cr(VI) bearing minerals, fractionation during abiotic aqueous Cr(VI) reduction, and non-fractionating precipitation of Cr(III) as sparingly soluble Cr-hydroxide. Accuracy of the presented solutions was ensured by running the problems with four well-established reactive transport modeling codes: TOUGHREACT, MIN3P, CRUNCHFLOW, and FLOTRAN. Results were also compared with an analytical Rayleigh-type fractionation model. An additional constraint on the correctness of the results was obtained by comparing output from the problem levels simulating Cr isotope fractionation with the corresponding ones only simulating bulk concentrations. For all problem levels, model to model comparisons showed excellent agreement, suggesting that for the tested geochemical processes any code is capable of accurately simulating the fate of individual Cr isotopes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Using quantum Monte Carlo, we study the nonequilibrium transport of magnetization in large open strongly correlated quantum spin-12 systems driven by purely dissipative processes that conserve the uniform or staggered magnetization, disregarding unitary Hamiltonian dynamics. We prepare both a low-temperature Heisenberg ferromagnet and an antiferromagnet in two parts of the system that are initially isolated from each other. We then bring the two subsystems in contact and study their real-time dissipative dynamics for different geometries. The flow of the uniform or staggered magnetization from one part of the system to the other is described by a diffusion equation that can be derived analytically.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The cometary coma is a unique phenomenon in the solar system being a planetary atmosphere influenced by little or no gravity. As a comet approaches the sun, the water vapor with some fraction of other gases sublimate, generating a cloud of gas, ice and other refractory materials (rocky and organic dust) ejected from the surface of the nucleus. Sublimating gas molecules undergo frequent collisions and photochemical processes in the near‐nucleus region. Owing to its negligible gravity, comets produce a large and highly variable extensive dusty coma with a size much larger than the characteristic size of the cometary nucleus. The Rosetta spacecraft is en route to comet 67P/Churyumov‐Gerasimenko for a rendezvous, landing, and extensive orbital phase beginning in 2014. Both, interpretation of measurements and safety consideration of the spacecraft require modeling of the comet’s dusty gas environment. In this work we present results of a numerical study of multispecies gaseous and electrically charged dust environment of comet Chyuryumov‐Gerasimenko. Both, gas and dust phases of the coma are simulated kinetically. Photolytic reactions are taken into account. Parameters of the ambient plasma as well as the distribution of electric/magnetic fields are obtained from an MHD simulation [1] of the coma connected to the solar wind. Trajectories of ions and electrically charged dust grains are simulated by accounting for the Lorentz force and the nucleus gravity.