96 resultados para SCREW FIXATION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To describe the advantages and surgical technique of a trochanteric flip osteotomy in combination with a Kocher-Langenbeck approach for the treatment of selected acetabular fractures. DESIGN: Consecutive series, teaching hospital. METHODS: Through mobilization of the vastus lateralis muscle, a slice of the greater trochanter with the attached gluteus medius muscle can be flipped anteriorly. The gluteus minimus muscle can then be easily mobilized, giving free access to the posterosuperior and superior acetabular wall area. Damage to the abductor muscles by vigorous retraction can be avoided, potentially resulting in less ectopic ossification. Ten consecutive cases of acetabular fractures treated with this approach are reported. In eight cases, an anatomic reduction was achieved; in the remaining two cases with severe comminution, the reduction was within one to three millimeters. The trochanteric fragment was fixed with two 3.5-millimeter cortical screws. RESULTS: All osteotomies healed in anatomic position within six to eight weeks postoperatively. Abductor strength was symmetric in eight patients and mildly reduced in two patients. Heterotopic ossification was limited to Brooker classes 1 and 2 without functional impairment at an average follow-up of twenty months. No femoral head necrosis was observed. CONCLUSION: This technique allows better visualization, more accurate reduction, and easier fixation of cranial acetabular fragments. Cranial migration of the greater trochanter after fixation with two screws is unlikely to occur because of the distal pull of the vastus lateralis muscle, balancing the cranial pull of the gluteus medius muscle.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although loosening of cemented glenoid components is one of the major complications of total shoulder arthroplasty, there is little information about factors affecting initial fixation of these components in the scapular neck. This study was performed to assess the characteristics of structural fixation of pegged glenoid components, if inserted with two different recommended cementing techniques. Six fresh-frozen shoulder specimens and two types of glenoid components were used. The glenoids were prepared according to the instructions and with the instrumentation of the manufacturer. In 3 specimens, the bone cement was inserted into the peg receiving holes (n = 12) and applied to the back surface of the glenoid component with a syringe. In the other 3 specimens, the cement was inserted into the holes (n = 15) by use of pure finger pressure: no cement was applied on the backside of the component. Micro-computed tomography scans with a resolution of 36 microm showed an intact cement mantle around all 12 pegs (100%) when a syringe was used. An incomplete cement plug was found in 7 of 15 pegs (47%) when the finger-pressure technique was used. Cement penetration into the cancellous bone was deeper in osteopenic bone. Application of bone cement on the backside of the glenoid prosthesis improved seating by filling out small spaces between bone and polyethylene resulting from irregularities after reaming or local cement extrusion from a drill hole. The fixation of a pegged glenoid component is better if the holes are filled with cement under pressure by use of a syringe and if cement is applied to the back of the glenoid component than if cement is inserted with pure finger pressure and no cement is applied to the back surface of the component.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The aim of this follow-up study was to evaluate the clinical usefulness of a new type of 3-dimensional (3D) miniplate for open reduction and monocortical fixation of mandibular angle fractures. PATIENTS AND METHODS: In 20 consecutive patients, noncomminuted mandibular angle fractures were treated with open reduction and fixation using a 2 mm 3D miniplate system in a transoral approach. All patients were systematically monitored until 6 months postoperatively. Among the outcome parameters recorded were infection, hardware failure, wound dehiscence, and sensory disturbance of the inferior alveolar nerve. RESULTS: The mean operation time from incision to wound closure was 65 minutes. Two patients had a mucosal wound dehiscence with no consequences. None developed an infection requiring a plate removal. All but 2 patients had normal sensory function 3 months after surgery. Plate fracture occurred in one patient in whom a preceding surgical removal of the third molar had been the reason for the mandibular fracture. In the absence of clinical symptoms, the patient declined plate removal. On final follow-up, fracture healing was considered clinically complete in all patients. CONCLUSIONS: The 3D plating system described here is suitable for fixation of simple mandibular angle fractures and is an easy-to-use alternative to conventional miniplates. The system may be contraindicated in patients in whom insufficient interfragmentary bone contact causes minor stability of the fracture.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We simulated a meta-population with random dispersal among demes but local mating within demes to investigate conditions under which a dominant female-determining gene W, with no individual selection advantage, can invade and become fixed in females, changing the population from male to female heterogamety. Starting with one mutant W in a single deme, the interaction of sex ratio selection and random genetic drift causes W to be fixed among females more often than a comparable neutral mutation with no influence on sex determination, even when YY males have slightly reduced viability. Meta-population structure and interdeme selection can also favour the fixation of W. The reverse transition from female to male heterogamety can also occur with higher probability than for a comparable neutral mutation. These results help to explain the involvement of sex-determining genes in the evolution of sex chromosomes and in sexual selection and speciation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The purpose of this systematic review was to evaluate relapse and its causes in bilateral sagittal split setback osteotomy with rigid internal fixation. MATERIALS AND METHODS: Literature research was done in databases such as PubMed, Ovid, the Cochrane Library, and Google Scholar Beta. From the original 488 articles identified, 14 articles were finally included. Only 5 studies were prospective and 9 retrospective. The range of postoperative study records was from 6 weeks to 12.7 years. RESULTS: The horizontal short-term relapse was between 9.9% and 62.1% at point B and between 15.7% and 91.3% at pogonion. Long-term relapse was between 14.9% and 28.0% at point B and between 11.5% and 25.4% at pogonion. CONCLUSIONS: Neither large increase nor decrease of relapse was seen when short-term values were compared with long-term. Bilateral sagittal split osteotomy for mandibular setback in combination with orthodontics is an effective treatment of skeletal Class III and a stable procedure in the short- and long-term. The etiology of relapse is multifactorial: the proper seating of the condyles, the amount of setback, the soft tissue and muscles, remaining growth and remodeling, and gender were identified. Age did not show any correlations. To obtain reliable scientific evidence, further short- and long-term research of bilateral sagittal split osteotomy setback with rigid internal fixation should exclude additional surgery, ie, genioplasty or maxillary surgery, and include correlation statistics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Percutaneous Kirschner wire fixation represents the classic treatment for displaced supracondylar humeral fractures in childhood. This type of treatment first requires satisfactory reduction of the fracture. Failure to achieve a satisfactory reduction or inadequate stabilization can result in instability of the fracture fragments, which can result in either an unsatisfactory cosmetic or functional outcome. In our experience, these problems can be overcome with the use of a small lateral external fixator. METHODS: Between 1999 and 2005, thirty-one of 170 Gartland type-III supracondylar humeral fractures were treated with a lateral external fixator. The outcome of treatment was analyzed with regard to limb alignment, elbow movement, cosmetic appearance, and patient satisfaction. RESULTS: In twenty-eight of the thirty-one patients, a satisfactory reduction was achieved with closed methods. All children except one had a normal or good range of movement. The cosmetic result was excellent in all cases. All of the children and their parents stated that they would choose this treatment again. CONCLUSIONS: The use of a small lateral external fixator seems to be a safe alternative for the treatment of displaced supracondylar fractures of the humerus when a closed reduction appears to be unattainable by means of manipulation alone or when sufficient stability is not achieved with standard methods of Kirschner wire fixation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The main indication for sacrospinous ligament suspension is to correct either total procidentia, a posthysterectomy vaginal vault prolapse with an associated weak cardinal uterosacral ligament complex, or a posthysterectomy enterocele. This study aimed to evaluate sexual function and anatomic outcome for patients after sacrospinous ligament suspension. METHODS: For this study, 52 patients who had undergone sacrospinous ligament fixation during the preceding 5 years were asked to complete the Female Sexual Function Index (FSFI) questionnaire. The patients were vaginally examined using the ICS POP score, and the results were compared with their preoperative status. For statistical analysis, GraphPad for Windows, version 4.0, was used. RESULTS: The 52 patients were examined during a follow-up period of 38 months. No major intraoperative complications were noted. Recurrence of symptomatic apical descent was noted in 6% of the patients and de novo prolapse in 13.5%. Only one patient was symptomatic. Three patients experienced de novo dyspareunia, which resolved in two cases after stitch removal. Sexual function was good, rating higher than three points for each of the domains including satisfaction, lubrication, desire, orgasm, and pain. CONCLUSION: Sacrospinous ligament fixation still is a valuable option for the treatment of vaginal vault prolapse. Sexual function is satisfactory, with few cases of de novo dyspareunia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigates the results of a technique using an extensor carpi radialis longus (ECRL) tenodesis for symptomatic scapholunate instability. Symptomatic scapholunate instability has been corrected so far either by limited wrist fusion or by various techniques of soft tissue repair. Limited wrist fusion greatly reduces wrist motion and increases the probability of osteoarthritis in the remaining mobile wrist segments. On the other hand, most types of soft tissue repair are technically difficult to perform and have disappointing results due to the inherent laxity. The presented dynamic approach was used in 20 wrists of 19 patients with static scapholunate instability. Preoperative evaluation included in all patients clinical examination, radiologic evaluation, and arthroscopy for establishing the diagnosis of static scapholunate instability. The technique involves the fixation of the ECRL tendon on the dorsal aspect of the scaphoid by means of a cancellous screw and a special washer. Dynamic ECRL tenodesis of the scaphoid is a safe and simple procedure that enhances the extension forces on the scaphoid in all wrist positions. The results of this preliminary report in 20 wrists showed dynamic ECRL tenodesis to be an effective treatment option for treating symptomatic static scapholunate instability.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Secondary intraocular lens (IOL) implantation is exposed to an increased risk of complications, including endophthalmitis and retinal detachment. The present analysis compares the outcomes and complications experienced in our own series of patients. PATIENTS AND METHODS: We retrospectively reviewed a consecutive series of secondary posterior chamber IOL implantations performed in a single centre, two surgeon setting over a period of 8 years and with a follow up-time of at least 4 months. RESULTS: Between 1997 and 2005, 75 patients received a sulcus-supported secondary IOL without suture fixation, whereas suture fixation was required in 137 instances. Visual acuity improved in both groups (group 1: from 0.36 +/- 0.39 (0.01-1.2) to 0.73 +/- 0.33 (0.02-1.0; p = 0.18); group 2: from 0.33 +/- 0.34 (0.02-1.0) to 0.46 +/- 0.33 (0.01-1.0; p = 0.006), but more pronounced in eyes not requiring suture fixation (p = 0.012). IOL placement was more likely to be combined with endophacoemulsification in the not suture-fixed IOLs (12.7 vs. 5.3 %). In contrast, retinal tears (10.6 vs. 8.6 %, respectively) and retinal detachment (5.3 vs. 2.2 %, respectively) were equally distributed. In the early postoperative phase, IOP was lower in suture-fixed eyes, which showed a higher incidence of minor intraocular haemorrhages and cystoid macular edema (5.3 vs. 8.0 %); late complications up to 5 years postoperatively were equally distributed. CONCLUSION: A preoperatively less complicated anterior segment situation and a lower incidence of postoperative macular edema may account for a better visual outcome after placement of a sulcus supported IOLs without suturing. If required, suture fixation may be performed without exposing the eye to an increased risk of late postoperative complications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: To present a novel, minimally invasive strabismus surgery (MISS) technique for rectus muscle posterior fixation. METHODS: This study reports the results of 32 consecutive MISS rectus muscle posterior fixation surgeries performed on 19 patients by applying only two small L-shaped openings where the two retroequatorial scleromuscular sutures were placed. RESULTS: On the first postoperative day, in primary position, redness was hardly visible in 16 eyes (50%) and only moderate redness was visible in 6 eyes (19%). No serious complication occurred. Preoperative visual acuity and refraction remained unchanged at 6 months (p > 0.1). The preoperative convergence excess (n = 13) decreased from 10.3 +/- 4.1 to 5.2 +/- 4.0 degrees at 6 months (p < 0.005). In all patients operated on for gaze incomitance (n = 6) improvement was achieved at 6 months. CONCLUSIONS: This study shows that keyhole minimal-dissection rectus muscle posterior fixation surgery is feasible and effective to improve ocular alignment. The MISS technique seems to be superior in the direct postoperative period since only minimal conjunctival swelling and no corneal complications were observed.