59 resultados para Robotic Arm


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Task-oriented, repetitive and intensive arm training can enhance arm rehabilitation in patients with paralyzed upper extremities due to lesions of the central nervous system. There is evidence that the training duration is a key factor for the therapy progress. Robot-supported therapy can improve the rehabilitation allowing more intensive training. This paper presents the kinematics, the control and the therapy modes of the arm therapy robot ARMin. It is a haptic display with semi-exoskeleton kinematics with four active and two passive degrees of freedom. Equipped with position, force and torque sensors the device can deliver patient-cooperative arm therapy taking into account the activity of the patient and supporting him/her only as much as needed. The haptic display is combined with an audiovisual display that is used to present the movement and the movement task to the patient. It is assumed that the patient-cooperative therapy approach combined with a multimodal display can increase the patient's motivation and activity and, therefore, the therapeutic progress.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE Mechanical thrombectomy using stent retriever devices have been advocated to increase revascularization in intracranial vessel occlusion. We present the results of a large prospective study on the use of the Solitaire Flow Restoration in patients with acute ischemic stroke. METHODS Solitaire Flow Restoration Thrombectomy for Acute Revascularization was an international, multicenter, prospective, single-arm study of Solitaire Flow Restoration thrombectomy in patients with large vessel anterior circulation strokes treated within 8 hours of symptom onset. Strict criteria for site selection were applied. The primary end point was the revascularization rate (thrombolysis in cerebral infarction ≥2b) of the occluded vessel as determined by an independent core laboratory. The secondary end point was the rate of good functional outcome (defined as 90-day modified Rankin scale, 0-2). RESULTS A total of 202 patients were enrolled across 14 comprehensive stroke centers in Europe, Canada, and Australia. The median age was 72 years, 60% were female patients. The median National Institute of Health Stroke Scale was 17. Most proximal intracranial occlusion was the internal carotid artery in 18%, and the middle cerebral artery in 82%. Successful revascularization was achieved in 79.2% of patients. Device and procedure-related severe adverse events were found in 7.4%. Favorable neurological outcome was found in 57.9%. The mortality rate was 6.9%. Any intracranial hemorrhagic transformation was found in 18.8% of patients, 1.5% were symptomatic. CONCLUSIONS In this single-arm study, treatment with the Solitaire Flow Restoration device in intracranial anterior circulation occlusions results in high rates of revascularization, low risk of clinically relevant procedural complications, and good clinical outcomes in combination with low mortality at 90 days. CLINICAL TRIAL REGISTRATION URL http://www.clinicaltrials.gov. Unique identifier: NCT01327989.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Laminin self-assembles into a basement membrane polymer through specific low-affinity interactions. Recently, it was shown that the terminal short-arm domain (domains VI and V) of the B1 chain (fragment E4) possesses one of the laminin self-interaction sites [Schittny, J.C. & Yurchenco, P.D. (1990) J. Cell Biol. 110, 825-832], but that the binding partner(s) of this domain is unknown. Using affinity retardation chromatography we now investigate the domain(s) fragment E4 binds to. The elution of E4 was clearly retarded on immobilized laminin and fragment E1' (three-chain short-arm complex excluding the distal part of the B1 chain), but not on immobilized E4 in calcium containing buffer and at 37 degrees C. Under the same conditions, E1' strongly interacts with immobilized E4. In addition, E1' is able to non-covalently cross-link soluble E4 to immobilized E4. No further interaction of laminin and E4 with additional fragments (P1', A, B2 and B1 chain short-arm complex without B1-domains VI-IV and without globules; E8, distal long arm and G1-3; E3, long-arm G subdomains 4 and 5) could be demonstrated. These data are interpreted as evidence that (a) the primary laminin-laminin bonds are formed between the short arms of laminin, that (b) the terminal B1 short-arm domain (E4) can interact with the short arm(s) of the A and/or B2 chain(s) (domain E1'), but does not self-interact, and that (c) due to at least three self-binding sites, laminin polymerization behaves co-operatively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Laminin self-assembles into large polymers by a cooperative two-step calcium-dependent mechanism (Yurchenco, P. D., E. C. Tsilibary, A. S. Charonis, and H. Furthmayr. 1985. J. Biol. Chem. 260:7636-7644). The domain specificity of this process was investigated using defined proteolytically generated fragments corresponding to the NH2-terminal globule and adjacent stem of the short arm of the B1 chain (E4), a complex of the two short arms of the A and B2 chains attached to the proximal stem of a third short arm (E1'), a similar complex lacking the globular domains (P1'), and the distal half of the long arm attached to the adjacent portion of the large globule (E8). Polymerization, followed by an increase of turbidity at 360 nm in neutral isotonic TBS containing CaCl2 at 35 degrees C, was quantitatively inhibited in a concentration-dependent manner with laminin fragments E4 and E1' but not with fragments E8 and P1'. Affinity retardation chromatography was used for further characterization of the binding of laminin domains. The migration of fragment E4, but not of fragments E8 and P1', was retarded in a temperature- and calcium-dependent fashion on a laminin affinity column but not on a similar BSA column. These data are evidence that laminin fragments E4 and E1' possess essential terminal binding domains for the self-aggregation of laminin, while fragments E8 and P1' do not. Furthermore, the individual domain-specific interactions that contribute to assembly are calcium dependent and of low affinity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In spite of its different cantonal jurisdictions and traditions, the development of religious education in Switzerland over the past decade has taken a common direction: the state has assumed a more active role in the field of religious education in public (state-run) schools. In this article, we ask the question: How do key social actors interpret these reforms and how do these interpretations relate to the social structure of religion in Switzerland, in particular with respect to the majority category of the so-called distanced Christians? Drawing on qualitative interviews with members of the schools’ teaching staff, school administrators, and church representatives, the article highlights a dominant interpretative pattern that frames the socially accepted representation of religion in public schools. Thus, rather than addressing the pedagogical dimension of religious education, we discuss the significance of this pattern for the debate on the public presence of religion in Switzerland and Europe.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Prostate cancer (PCa) is the second most common disease among men worldwide. It is important to know survival outcomes and prognostic factors for this disease. Recruitment for the largest therapeutic randomised controlled trial in PCa-the Systemic Therapy in Advancing or Metastatic Prostate Cancer: Evaluation of Drug Efficacy: A Multi-Stage Multi-Arm Randomised Controlled Trial (STAMPEDE)-includes men with newly diagnosed metastatic PCa who are commencing long-term androgen deprivation therapy (ADT); the control arm provides valuable data for a prospective cohort. OBJECTIVE Describe survival outcomes, along with current treatment standards and factors associated with prognosis, to inform future trial design in this patient group. DESIGN, SETTING, AND PARTICIPANTS STAMPEDE trial control arm comprising men newly diagnosed with M1 disease who were recruited between October 2005 and January 2014. OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS Overall survival (OS) and failure-free survival (FFS) were reported by primary disease characteristics using Kaplan-Meier methods. Hazard ratios and 95% confidence intervals (CIs) were derived from multivariate Cox models. RESULTS AND LIMITATIONS A cohort of 917 men with newly diagnosed M1 disease was recruited to the control arm in the specified interval. Median follow-up was 20 mo. Median age at randomisation was 66 yr (interquartile range [IQR]: 61-71), and median prostate-specific antigen level was 112 ng/ml (IQR: 34-373). Most men (n=574; 62%) had bone-only metastases, whereas 237 (26%) had both bone and soft tissue metastases; soft tissue metastasis was found mainly in distant lymph nodes. There were 238 deaths, 202 (85%) from PCa. Median FFS was 11 mo; 2-yr FFS was 29% (95% CI, 25-33). Median OS was 42 mo; 2-yr OS was 72% (95% CI, 68-76). Survival time was influenced by performance status, age, Gleason score, and metastases distribution. Median survival after FFS event was 22 mo. Trial eligibility criteria meant men were younger and fitter than general PCa population. CONCLUSIONS Survival remains disappointing in men presenting with M1 disease who are started on only long-term ADT, despite active treatments being available at first failure of ADT. Importantly, men with M1 disease now spend the majority of their remaining life in a state of castration-resistant relapse. PATIENT SUMMARY Results from this control arm cohort found survival is relatively short and highly influenced by patient age, fitness, and where prostate cancer has spread in the body.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The robotic approach in thoracic surgery has rapidly gained popularity in recent years. As with the introduction of any new technology, this warrants not only adaptation of the operative technique itself, but also the evolution of appropriate troubleshooting strategies. A selected number of helpful tips and technical procedural manoeuvres have been compiled to prevent intraoperative problems, as well as to overcome challenging situations that can arise during robotic lobectomies. In robotic surgery, as opposed to open surgery or video-assisted thoracic surgery, these tips serve an important purpose for the operating surgeon, as well as the entire surgical team involved in the procedure. All the assembled recommendations have proved their effectiveness and have been successfully used by the authors in many procedures. Furthermore, these manoeuvres have been found to be of great importance in the training and proctoring of thoracic surgeons, fellows and residents (bed-side assistants). This guide of clearly arranged tips and troubleshooting strategies offers surgeons a useful tool to overcome difficult situations in robotic lobectomy and preferably improve the reproducibility and safety of their procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we propose a new method for stitching multiple fluoroscopic images taken by a C-arm instrument. We employ an X-ray radiolucent ruler with numbered graduations while acquiring the images, and the image stitching is based on detecting and matching ruler parts in the images to the corresponding parts of a virtual ruler. To achieve this goal, we first detect the regular spaced graduations on the ruler and the numbers. After graduation labeling, for each image, we have the location and the associated number for every graduation on the ruler. Then, we initialize the panoramic X-ray image with the virtual ruler, and we “paste” each image by aligning the detected ruler part on the original image, to the corresponding part of the virtual ruler on the panoramic image. Our method is based on ruler matching but without the requirement of matching similar feature points in pairwise images, and thus, we do not necessarily require overlap between the images. We tested our method on eight different datasets of X-ray images, including long bones and a complete spine. Qualitative and quantitative experiments show that our method achieves good results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Surgical robots have been proposed ex vivo to drill precise holes in the temporal bone for minimally invasive cochlear implantation. The main risk of the procedure is damage of the facial nerve due to mechanical interaction or due to temperature elevation during the drilling process. To evaluate the thermal risk of the drilling process, a simplified model is proposed which aims to enable an assessment of risk posed to the facial nerve for a given set of constant process parameters for different mastoid bone densities. The model uses the bone density distribution along the drilling trajectory in the mastoid bone to calculate a time dependent heat production function at the tip of the drill bit. Using a time dependent moving point source Green's function, the heat equation can be solved at a certain point in space so that the resulting temperatures can be calculated over time. The model was calibrated and initially verified with in vivo temperature data. The data was collected in minimally invasive robotic drilling of 12 holes in four different sheep. The sheep were anesthetized and the temperature elevations were measured with a thermocouple which was inserted in a previously drilled hole next to the planned drilling trajectory. Bone density distributions were extracted from pre-operative CT data by averaging Hounsfield values over the drill bit diameter. Post-operative [Formula: see text]CT data was used to verify the drilling accuracy of the trajectories. The comparison of measured and calculated temperatures shows a very good match for both heating and cooling phases. The average prediction error of the maximum temperature was less than 0.7 °C and the average root mean square error was approximately 0.5 °C. To analyze potential thermal damage, the model was used to calculate temperature profiles and cumulative equivalent minutes at 43 °C at a minimal distance to the facial nerve. For the selected drilling parameters, temperature elevation profiles and cumulative equivalent minutes suggest that thermal elevation of this minimally invasive cochlear implantation surgery may pose a risk to the facial nerve, especially in sclerotic or high density mastoid bones. Optimized drilling parameters need to be evaluated and the model could be used for future risk evaluation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

HYPOTHESIS A multielectrode probe in combination with an optimized stimulation protocol could provide sufficient sensitivity and specificity to act as an effective safety mechanism for preservation of the facial nerve in case of an unsafe drill distance during image-guided cochlear implantation. BACKGROUND A minimally invasive cochlear implantation is enabled by image-guided and robotic-assisted drilling of an access tunnel to the middle ear cavity. The approach requires the drill to pass at distances below 1 mm from the facial nerve and thus safety mechanisms for protecting this critical structure are required. Neuromonitoring is currently used to determine facial nerve proximity in mastoidectomy but lacks sensitivity and specificity necessaries to effectively distinguish the close distance ranges experienced in the minimally invasive approach, possibly because of current shunting of uninsulated stimulating drilling tools in the drill tunnel and because of nonoptimized stimulation parameters. To this end, we propose an advanced neuromonitoring approach using varying levels of stimulation parameters together with an integrated bipolar and monopolar stimulating probe. MATERIALS AND METHODS An in vivo study (sheep model) was conducted in which measurements at specifically planned and navigated lateral distances from the facial nerve were performed to determine if specific sets of stimulation parameters in combination with the proposed neuromonitoring system could reliably detect an imminent collision with the facial nerve. For the accurate positioning of the neuromonitoring probe, a dedicated robotic system for image-guided cochlear implantation was used and drilling accuracy was corrected on postoperative microcomputed tomographic images. RESULTS From 29 trajectories analyzed in five different subjects, a correlation between stimulus threshold and drill-to-facial nerve distance was found in trajectories colliding with the facial nerve (distance <0.1 mm). The shortest pulse duration that provided the highest linear correlation between stimulation intensity and drill-to-facial nerve distance was 250 μs. Only at low stimulus intensity values (≤0.3 mA) and with the bipolar configurations of the probe did the neuromonitoring system enable sufficient lateral specificity (>95%) at distances to the facial nerve below 0.5 mm. However, reduction in stimulus threshold to 0.3 mA or lower resulted in a decrease of facial nerve distance detection range below 0.1 mm (>95% sensitivity). Subsequent histopathology follow-up of three representative cases where the neuromonitoring system could reliably detect a collision with the facial nerve (distance <0.1 mm) revealed either mild or inexistent damage to the nerve fascicles. CONCLUSION Our findings suggest that although no general correlation between facial nerve distance and stimulation threshold existed, possibly because of variances in patient-specific anatomy, correlations at very close distances to the facial nerve and high levels of specificity would enable a binary response warning system to be developed using the proposed probe at low stimulation currents.