52 resultados para Reproducibility of serological tests


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report the detailed documented case of a 57-year-old homosexual HIV-positive man with bilateral cochleovestibular deficits as a first symptom of syphilis infection in early stage II disease. As a morphological substrate, a strong enhancement of both inner ears and vestibulocochlear nerves were found on gadolinium-enhanced MR scans. The serological tests identified an active infection with Treponema pallidum. After a high-dose treatment with penicillin G and prednisolone, the auditory and vestibular functions and the MR morphology of the vestibulocochlear nerves and inner ears on both sides returned to normal.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND In 2006, bluetongue virus serotype 8 (BTV-8) was detected for the first time in central Europe. Measures to control the infection in livestock were implemented in Switzerland but the question was raised whether free-ranging wildlife could be a maintenance host for BTV-8. Furthermore Toggenburg orbivirus (TOV), considered as a potential 25th BTV serotype, was detected in 2007 in domestic goats in Switzerland and wild ruminants were considered a potential source of infection. To assess prevalences of BTV-8 and TOV infections in wildlife, we conducted a serological and virological survey in red deer, roe deer, Alpine chamois and Alpine ibex between 2009 and 2011. Because samples originating from wildlife carcasses are often of poor quality, we also documented the influence of hemolysis on test results, and evaluated the usefulness of confirmatory tests. RESULTS Ten out of 1,898 animals (0.5%, 95% confidence interval 0.3-1.0%) had detectable antibodies against BTV-8 and BTV-8 RNA was found in two chamois and one roe deer (0.3%, 0.1-0.8%). Seroprevalence was highest among red deer, and the majority of positive wild animals were sampled close to areas where outbreaks had been reported in livestock. Most samples were hemolytic and the range of the optical density percentage values obtained in the screening test increased with increasing hemolysis. Confirmatory tests significantly increased specificity of the testing procedure and proved to be applicable even on poor quality samples. Nearly all samples confirmed as positive had an optical density percentage value greater than 50% in the ELISA screening. CONCLUSIONS Prevalence of BTV-8 infection was low, and none of the tested animals were positive for TOV. Currently, wild ruminants are apparently not a reservoir for these viruses in Switzerland. However, we report for the first time BTV-8 RNA in Alpine chamois. This animal was found at high altitude and far from a domestic outbreak, which suggests that the virus could spread into/through the Alps. Regarding testing procedures, hemolysis did not significantly affect test results but confirmatory tests proved to be necessary to obtain reliable prevalence estimates. The cut-off value recommended by the manufacturer for the screening test was applicable for wildlife samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Impairment of cognitive performance during and after high-altitude climbing has been described in numerous studies and has mostly been attributed to cerebral hypoxia and resulting functional and structural cerebral alterations. To investigate the hypothesis that high-altitude climbing leads to cognitive impairment, we used of neuropsychological tests and measurements of eye movement (EM) performance during different stimulus conditions. The study was conducted in 32 mountaineers participating in an expedition to Muztagh Ata (7,546 m). Neuropsychological tests comprised figural fluency, line bisection, letter and number cancellation, and a modified pegboard task. Saccadic performance was evaluated under three stimulus conditions with varying degrees of cortical involvement: visually guided pro- and anti-saccades, and visuo-visual interaction. Typical saccade parameters (latency, mean sequence, post-saccadic stability, and error rate) were computed off-line. Measurements were taken at a baseline level of 440 m and at altitudes of 4,497, 5,533, 6,265, and again at 440 m. All subjects reached 5,533 m, and 28 reached 6,265 m. The neuropsychological test results did not reveal any cognitive impairment. Complete eye movement recordings for all stimulus conditions were obtained in 24 subjects at baseline and at least two altitudes and in 10 subjects at baseline and all altitudes. Measurements of saccade performances showed no dependence on any altitude-related parameter and were well within normal limits. Our data indicates that acclimatized climbers do not seem to suffer from significant cognitive deficits during or after climbs to altitudes above 7,500 m. We demonstrated that investigation of EMs is feasible during high-altitude expeditions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Diagnostic tests based on cell-mediated immunity are used in programmes for eradication of bovine tuberculosis (Mycobacterium bovis). Serological assays could be applied as ancillary methods to detect infected animals. Our objective was to evaluate two serological techniques: M. bovis Ab Test (IDEXX, USA) and Enferplex™ TB assay (Enfer, Ireland) in animals tested simultaneously with the single and comparative intradermal tests and the interferon-gamma assay. This work was performed at two stages. First, a preliminary panel of samples collected prior to intradermal tests from tuberculosis-free (n=60) and M. bovis-infected herds (n=78) was assayed, obtaining high specificity: 100% (M. bovis Ab Test) and 98.3% (Enferplex TB assay) but low sensitivity (detection of M. bovis infected animals): 23.9% (M. bovis Ab Test) and 32.6% (Enferplex TB assay). Subsequently, the use of serological techniques was further studied in two herds with M. bovis infection (n=77) using samples collected prior to, and 72 h and 15 days after PPD inoculation. The highest level of detection of infected animals for serology was achieved at 15 days post-intradermal tests taking advantage of the anamnestic effect: 70.4% and 85.2% in herd A, and 66.7% and 83.3% in herd B, using M. bovis Ab Test and Enferplex TB assay, respectively. Quantitative results (average values obtained with M. bovis Ab Test ELISA and degree of positivity obtained with Enferplex TB assay) were higher in animals showing lesions compatible with tuberculosis. No significant differences were observed in the number of confirmed infected animals detected with either serological technique.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bovine besnoitiosis has been diagnosed in neighboring countries but not in Switzerland so far. This disease occurs endemically in France and focal outbreaks have been reported in Germany and Italy. To determine if Besnoitia besnoiti is introduced into Switzerland through the import of breeding cattle from France, a systematic serological survey was performed. A total of 412 breeding cattle (from 114 farms) imported from France into Switzerland between 2005 and 2011, were serologically examined for antibodies against B. besnoiti using a commercial ELISA kit (PrioCHECK© Besnoitia Ab 2.0, Prionics AG, Zurich, Switzerland). Sixty-four (15.5 %) animals reacted positive in ELISA. The serologic diagnosis was confirmed by an indirect immunfluorescence test (IFAT) and a Western blot (WB) in only 2 Limousin cows imported from France on a farm in Eastern Switzerland. Subsequently, this whole herd (n = 16) was examined clinically and serologically and 2 additional Limousin cows imported from Germany also reacted positive in the three serological tests. One of these cows presented B. besnoiti tissue cysts in the scleral conjunctiva and typical skin lesions in the head region. The infection was further confirmed cytologically, histopathologically and by PCR. It can be concluded that the parasite is most likely being introduced into Switzerland through the import of infected animals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have previously isolated anti-FcepsilonRIalpha autoantibodies from phage libraries of healthy donors and urticaria patients. Strikingly, the same antibody, LTMalpha15, was isolated from both libraries. Sequence analysis revealed a germline configuration of the LTMalpha15 variable heavy (V(H)) chain with a slightly mutated variable light (V(L)) chain supporting its classification as a natural autoantibody. Distribution analysis of anti-FcepsilonRIalpha autoantibodies by functional or serological tests delivered conflicting data. For this reason we have developed a new real-time PCR to analyse the distribution of LTMalpha15V(H) in healthy donors and urticaria patients. Our new bioinformatic program permitted the design of a minor groove binder (MGB) TaqMan probe that specifically detected the LTMalpha15V(H). We were able to demonstrate a broad range of rearranged V(H) gene copy number without any correlation to the state of health. Monitoring LTMalpha15V(H) gene copy number in a single donor over a period of 70 days revealed a time-related fluctuation of circulating B cells carrying LTMalpha15V(H). We propose that our real-time PCR may serve as a model for the quantification of natural antibody sequences at a monoclonal level.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVES Reliability is an essential condition for using quantitative sensory tests (QSTs) in research and clinical practice, but information on reliability in patients with chronic pain is sparse. The aim of this study was to evaluate the reliability of different QST in patients with chronic low back pain. METHODS Eighty-nine patients with chronic low back pain participated in 2 identical experimental sessions, separated by at least 7 days. The following parameters were recorded: pressure pain detection and tolerance thresholds at the toe, electrical pain thresholds to single and repeated stimulation, heat pain detection and tolerance thresholds at the arm and leg, cold pain detection threshold at the arm and leg, and conditioned pain modulation using the cold pressor test.Reliability was analyzed using the coefficient of variation, the coefficient of repeatability, and the intraclass correlation coefficient. It was judged as acceptable or not based primarily on the analysis of the coefficient of repeatability. RESULTS The reliability of most tests was acceptable. Exceptions were cold pain detection thresholds at the leg and arm. CONCLUSIONS Most QST measurements have acceptable reliability in patients with chronic low back pain.