52 resultados para Reliability


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND The abstraction of data from medical records is a widespread practice in epidemiological research. However, studies using this means of data collection rarely report reliability. Within the Transition after Childhood Cancer Study (TaCC) which is based on a medical record abstraction, we conducted a second independent abstraction of data with the aim to assess a) intra-rater reliability of one rater at two time points; b) the possible learning effects between these two time points compared to a gold-standard; and c) inter-rater reliability. METHOD Within the TaCC study we conducted a systematic medical record abstraction in the 9 Swiss clinics with pediatric oncology wards. In a second phase we selected a subsample of medical records in 3 clinics to conduct a second independent abstraction. We then assessed intra-rater reliability at two time points, the learning effect over time (comparing each rater at two time-points with a gold-standard) and the inter-rater reliability of a selected number of variables. We calculated percentage agreement and Cohen's kappa. FINDINGS For the assessment of the intra-rater reliability we included 154 records (80 for rater 1; 74 for rater 2). For the inter-rater reliability we could include 70 records. Intra-rater reliability was substantial to excellent (Cohen's kappa 0-6-0.8) with an observed percentage agreement of 75%-95%. In all variables learning effects were observed. Inter-rater reliability was substantial to excellent (Cohen's kappa 0.70-0.83) with high agreement ranging from 86% to 100%. CONCLUSIONS Our study showed that data abstracted from medical records are reliable. Investigating intra-rater and inter-rater reliability can give confidence to draw conclusions from the abstracted data and increase data quality by minimizing systematic errors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVES Reliability is an essential condition for using quantitative sensory tests (QSTs) in research and clinical practice, but information on reliability in patients with chronic pain is sparse. The aim of this study was to evaluate the reliability of different QST in patients with chronic low back pain. METHODS Eighty-nine patients with chronic low back pain participated in 2 identical experimental sessions, separated by at least 7 days. The following parameters were recorded: pressure pain detection and tolerance thresholds at the toe, electrical pain thresholds to single and repeated stimulation, heat pain detection and tolerance thresholds at the arm and leg, cold pain detection threshold at the arm and leg, and conditioned pain modulation using the cold pressor test.Reliability was analyzed using the coefficient of variation, the coefficient of repeatability, and the intraclass correlation coefficient. It was judged as acceptable or not based primarily on the analysis of the coefficient of repeatability. RESULTS The reliability of most tests was acceptable. Exceptions were cold pain detection thresholds at the leg and arm. CONCLUSIONS Most QST measurements have acceptable reliability in patients with chronic low back pain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To assess the reliability of the cervical vertebrae maturation method (CVM). BACKGROUND Skeletal maturity estimation can influence the manner and time of orthodontic treatment. The CVM method evaluates skeletal growth on the basis of the changes in the morphology of cervical vertebrae C2, C3, C4 during growth. These vertebrae are visible on a lateral cephalogram, so the method does not require an additional radiograph. METHODS In this website based study, 10 orthodontists with a long clinical practice (3 routinely using the method - "Routine user - RU" and 7 with less experience in the CVM method - "Non-Routine user - nonRU") rated twice cervical vertebrae maturation with the CVM method on 50 cropped scans of lateral cephalograms of children in circumpubertal age (for boys: 11.5 to 15.5 years; for girls: 10 to 14 years). Kappa statistics (with lower limits of 95% confidence intervals (CI)) and proportion of complete agreement on staging was used to evaluate intra- and inter-assessor agreement. RESULTS The mean weighted kappa for intra-assessor agreement was 0.44 (range: 0.30-0.64; range of lower limits of 95% CI: 0.12-0.48) and for inter-assessor agreement was 0.28 (range: -0.01-0.58; range of lower limits of 95% CI: -0.14-0.42). The mean proportion of identical scores assigned by the same assessor was 55.2 %(range: 44-74 %) and for different pairs of assessors was 42 % (range: 16-68 %). CONCLUSIONS The reliability of the CVM method is questionable and if orthodontic treatment should be initiated relative to the maximum growth, the use of additional biologic indicators should be considered (Tab. 4, Fig. 1, Ref. 24).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE Stress urinary incontinence (SUI) affects women of all ages including young athletes, especially those involved in high-impact sports. To date, hardly any studies are available testing pelvic floor muscles (PFM) during sports activities. The aim of this study was the description and reliability test of six PFM electromyography (EMG) variables during three different running speeds. The secondary objective was to evaluate whether there was a speed-dependent difference between the PFM activity variables. METHODS This trial was designed as an exploratory and reliability study including ten young healthy female subjects to characterize PFM pre-activity and reflex activity during running at 7, 9 and 11 km/h. Six variables for each running speed, averaged over ten steps per subject, were presented descriptively, tested regarding their reliability (Friedman, ICC, SEM, MD) and speed difference (Friedman). RESULTS PFM EMG variables varied between 67.6 and 106.1 %EMG, showed no systematic error and were low for SEM and MD using the single value model. Applying the average model over ten steps, ICC (3,k) were >0.75 and SEM and MD about 50 % lower than for the single value model. Activity was found to be highest in 11 km/h. CONCLUSION EMG variables showed excellent ICC and very low SEM and MD. Further studies should investigate inter-session reliability and PFM reactivity patterns of SUI patients using the average over ten steps for each variable as it showed very high ICC and very low SEM and MD. Subsequently, longer running distances and other high-impact sports disciplines could be studied.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Glycogen is a major substrate in energy metabolism and particularly important to prevent hypoglycemia in pathologies of glucose homeostasis such as type 1 diabetes mellitus (T1DM). (13) C-MRS is increasingly used to determine glycogen in skeletal muscle and liver non-invasively; however, the low signal-to-noise ratio leads to long acquisition times, particularly when glycogen levels are determined before and after interventions. In order to ease the requirements for the subjects and to avoid systematic effects of the lengthy examination, we evaluated if a standardized preparation period would allow us to shift the baseline (pre-intervention) experiments to a preceding day. Based on natural abundance (13) C-MRS on a clinical 3 T MR system the present study investigated the test-retest reliability of glycogen measurements in patients with T1DM and matched controls (n = 10 each group) in quadriceps muscle and liver. Prior to the MR examination, participants followed a standardized diet and avoided strenuous exercise for two days. The average coefficient of variation (CV) of myocellular glycogen levels was 9.7% in patients with T1DM compared with 6.6% in controls after a 2 week period, while hepatic glycogen variability was 13.3% in patients with T1DM and 14.6% in controls. For comparison, a single-session test-retest variability in four healthy volunteers resulted in 9.5% for skeletal muscle and 14.3% for liver. Glycogen levels in muscle and liver were not statistically different between test and retest, except for hepatic glycogen, which decreased in T1DM patients in the retest examination, but without an increase of the group distribution. Since the CVs of glycogen levels determined in a "single session" versus "within weeks" are comparable, we conclude that the major source of uncertainty is the methodological error and that physiological variations can be minimized by a pre-study standardization. For hepatic glycogen examinations, familiarization sessions (MR and potentially strenuous interventions) are recommended. Copyright © 2016 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Measuring the ratio of heterophils and lymphocytes (H/L) in response to different stressors is a standard tool for assessing long-term stress in laying hens but detailed information on the reliability of measurements, measurement techniques and methods, and absolute cell counts is often lacking. Laying hens offered different sites of the nest boxes at different ages were compared in a two-treatment crossover experiment to provide detailed information on the procedure for measuring and the difficulties in the interpretation of H/L ratios in commercial conditions. H/L ratios were pen-specific and depended on the age and aviary system. There was no effect for the position of the nest. Heterophiles and lymphocytes were not correlated within individuals. Absolute cell counts differed in the number of heterophiles and lymphocytes and H/L ratios, whereas absolute leucocyte counts between individuals were similar. The reliability of the method using relative cell counts was good, yielding a correlation coefficient between double counts of r > 0.9. It was concluded that population-based reference values may not be sensitive enough to detect individual stress reactions and that the H/L ratio as an indicator of stress under commercial conditions may not be useful because of confounding factors and that other, non-invasive, measurements should be adopted.