228 resultados para Randomized controlled clinical trial


Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND/AIMS Several countries are working to adapt clinical trial regulations to align the approval process to the level of risk for trial participants. The optimal framework to categorize clinical trials according to risk remains unclear, however. Switzerland is the first European country to adopt a risk-based categorization procedure in January 2014. We assessed how accurately and consistently clinical trials are categorized using two different approaches: an approach using criteria set forth in the new law (concept) or an intuitive approach (ad hoc). METHODS This was a randomized controlled trial with a method-comparison study nested in each arm. We used clinical trial protocols from eight Swiss ethics committees approved between 2010 and 2011. Protocols were randomly assigned to be categorized in one of three risk categories using the concept or the ad hoc approach. Each protocol was independently categorized by the trial's sponsor, a group of experts and the approving ethics committee. The primary outcome was the difference in categorization agreement between the expert group and sponsors across arms. Linear weighted kappa was used to quantify agreements, with the difference between kappas being the primary effect measure. RESULTS We included 142 of 231 protocols in the final analysis (concept = 78; ad hoc = 64). Raw agreement between the expert group and sponsors was 0.74 in the concept and 0.78 in the ad hoc arm. Chance-corrected agreement was higher in the ad hoc (kappa: 0.34 (95% confidence interval = 0.10-0.58)) than in the concept arm (0.27 (0.06-0.50)), but the difference was not significant (p = 0.67). LIMITATIONS The main limitation was the large number of protocols excluded from the analysis mostly because they did not fit with the clinical trial definition of the new law. CONCLUSION A structured risk categorization approach was not better than an ad hoc approach. Laws introducing risk-based approaches should provide guidelines, examples and templates to ensure correct application.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The single-use supraglottic airway device i-gel™ has been described in several case reports as a conduit for intubation, but no prospective data about success rates of blind intubation are available. Therefore, we performed this prospective randomized controlled trial to compare the success rate of blind tracheal intubation with a Magill PVC tube through the i-gel™ with intubation using an sILMA™ PVC tube through the single-use intubating laryngeal mask airway (sILMA™).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Sedation prior to performance of diagnostic esophagogastroduodenoscopy (EGDE) is widespread and increases patient comfort. But 98% of all serious adverse events during EGDEs are ascribed to sedation. The S3 guideline for sedation procedures in gastrointestinal endoscopy published in 2008 in Germany increases patient safety by standardization. These new regulations increase costs because of the need for more personnel and a prolonged discharge procedure after examinations with sedation. Many patients have difficulties to meet the discharge criteria regulated by the S3 guideline, e.g. the call for a second person to escort them home, to resign from driving and working for the rest of the day, resulting in a refusal of sedation. Therefore, we would like to examine if an acupuncture during elective, diagnostic EGDEs could increase the comfort of patients refusing systemic sedation. Methods/Design A single-center, double blinded, placebo controlled superiority trial to compare the success rates of elective, diagnostic EGDEs with real and placebo acupuncture. All patients aged 18 years or older scheduled for elective, diagnostic EGDE who refuse a systemic sedation are eligible. 354 patients will be randomized. The primary endpoint is the rate of successful EGDEs with the randomized technique. Intervention: Real or placebo acupuncture before and during EGDE. Duration of study: Approximately 24 months. Discussion Organisation/Responsibility The ACUPEND - Trial will be conducted in accordance with the protocol and in compliance with the moral, ethical, and scientific principles governing clinical research as set out in the Declaration of Helsinki (1989) and Good Clinical Practice (GCP). The Interdisciplinary Endoscopy Center (IEZ) of the University Hospital Heidelberg is responsible for design and conduct of the trial, including randomization and documentation of patients' data. Data management and statistical analysis will be performed by the independent Institute for Medical Biometry and Informatics (IMBI) and the Center of Clinical Trials (KSC) at the Department of General, Visceral and Transplantation Surgery, University of Heidelberg.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives This study sought to compare the efficacy of passive stent coating with titanium-nitride-oxide (TiNO) with drug-eluting stents releasing zotarolimus (ZES) (Endeavor, Medtronic, Minneapolis, Minnesota). Background Stent coating with TiNO has been shown to reduce restenosis compared with bare-metal stents in experimental and clinical studies. Methods In an assessor-blind noninferiority study, 302 patients undergoing percutaneous coronary intervention were randomized to treatment with TiNO or ZES. The primary endpoint was in-stent late loss at 6 to 8 months, and analysis was by intention to treat. Results Both groups were well balanced with respect to baseline clinical and angiographic characteristics. The TiNO group failed to reach the pre-specified noninferiority margin for the primary endpoint (in-stent late loss: 0.64 ± 0.61 mm vs. 0.47 ± 0.48 mm, difference: 0.16, upper 1-sided 95% confidence interval [CI]: 0.26; pnoninferiority = 0.54), and subsequent superiority testing was in favor of ZES (psuperiority = 0.02). In-segment binary restenosis was lower with ZES (11.1%) than with TiNO (20.5%; psuperiority = 0.04). A stratified analysis of the primary endpoint found particularly pronounced differences between stents among diabetic versus nondiabetic patients (0.90 ± 0.69 mm vs. 0.39 ± 0.38 mm; pinteraction = 0.04). Clinical outcomes showed a similar rate of death (0.7% vs. 0.7%; p = 1.00), myocardial infarction (5.3% vs. 6.7%; p = 0.60), and major adverse cardiac events (21.1% vs. 18.0%, hazard ratio: 1.19, 95% CI: 0.71 to 2.00; p = 0.50) at 1 year. There were no differences in rates of definite or probable stent thrombosis (0.7% vs. 0%; p = 0.51) at 1 year. Conclusions Compared with TiNO, ZES was superior with regard to late loss and binary restenosis. The concept of passive stent coating with TiNO remains inferior to drug-eluting stent technology in reducing restenosis. ([TIDE] Randomized Trial Comparing Titan Stent With Zotarolimus-Eluting Stent: NCT00492908)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hypertension is a powerful treatable risk factor for stroke. Reports of randomized controlled trials (RCTs) of antihypertensive drugs rightly concentrate on clinical outcomes, but control of blood pressure (BP) during follow-up is also important, particularly given that inconsistent control is associated with a high risk of stroke and that antihypertensive drug classes differ in this regard.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Retention of overdentures is important for patients' satisfaction. The study tested whether the clinical performance of retentive clips made of poly-ether-ether-ketone (PEEK) is superior to those made of poly-oxy-methylene (POM).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this study, we aimed to investigate whether studies published in orthodontic journals and titled as randomized clinical trials are truly randomized clinical trials. A second objective was to explore the association of journal type and other publication characteristics on correct classification.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The use of endosseous dental implants has become common practice for the rehabilitation of edentulous patients, and a two-implant overdenture has been recommended as the standard of care. The use of small-diameter implants may extend treatment options and reduce the necessity for bone augmentation. However, the mechanical strength of titanium is limited, so titanium alloys with greater tensile and fatigue strength may be preferable. Purpose: This randomized, controlled, double-blind, multicenter study investigated in a split-mouth model whether small-diameter implants made from Titanium-13Zirconium alloy (TiZr, Roxolid™) perform at least as well as Titanium Grade IV implants. Methods and Materials: Patients with an edentulous mandible received one TiZr and one Ti Grade IV small-diameter bone level implant (3.3 mm, SLActive®) in the interforaminal region. The site distribution was randomized and double-blinded. Outcome measures included change in radiological peri-implant bone level from surgery to 12 months post-insertion (primary), implant survival, success, soft tissue conditions, and safety (secondary). Results: Of 91 treated patients, 87 were available for the 12-month follow-up. Peri-implant bone level change (-0.3 ± 0.5 mm vs -0.3 ± 0.6 mm), plaque, and sulcus bleeding indices were not significantly different between TiZr and Ti Grade IV implants. Implant survival rates were 98.9 percent and 97.8 percent, success rates were 96.6 percent and 94.4 percent, respectively. Nineteen minor and no serious adverse events were related to the study devices. Conclusion: This study confirms that TiZr small-diameter bone level implants provide at least the same outcomes after 12 months as Ti Grade IV bone level implants. The improved mechanical properties of TiZr implants may extend implant therapy to more challenging clinical situations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Screening of peripheral atherosclerosis is increasingly used, but few trials have examined its clinical impact. We aimed to assess whether carotid plaque screening helps smokers to improve their health behaviors and cardiovascular risk factors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In cirrhosis, hepatic endothelial dysfunction as a result of oxidative stress contributes to the postprandial increase in hepatic venous pressure gradient (HVPG).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

CONTEXT: Compared with bare metal stents, sirolimus-eluting and paclitaxel-eluting stents have been shown to markedly improve angiographic and clinical outcomes after percutaneous coronary revascularization, but their performance in the treatment of de novo coronary lesions has not been compared in a prospective multicenter study. OBJECTIVE: To compare the safety and efficacy of sirolimus-eluting vs paclitaxel-eluting coronary stents. DESIGN: Prospective, randomized comparative trial (the REALITY trial) conducted between August 2003 and February 2004, with angiographic follow-up at 8 months and clinical follow-up at 12 months. SETTING: Ninety hospitals in Europe, Latin America, and Asia. PATIENTS: A total of 1386 patients (mean age, 62.6 years; 73.1% men; 28.0% with diabetes) with angina pectoris and 1 or 2 de novo lesions (2.25-3.00 mm in diameter) in native coronary arteries. INTERVENTION: Patients were randomly assigned in a 1:1 ratio to receive a sirolimus-eluting stent (n = 701) or a paclitaxel-eluting stent (n = 685). MAIN OUTCOME MEASURES: The primary end point was in-lesion binary restenosis (presence of a more than 50% luminal-diameter stenosis) at 8 months. Secondary end points included 1-year rates of target lesion and vessel revascularization and a composite end point of cardiac death, Q-wave or non-Q-wave myocardial infarction, coronary artery bypass graft surgery, or repeat target lesion revascularization. RESULTS: In-lesion binary restenosis at 8 months occurred in 86 patients (9.6%) with a sirolimus-eluting stent vs 95 (11.1%) with a paclitaxel-eluting stent (relative risk [RR], 0.84; 95% confidence interval [CI], 0.61-1.17; P = .31). For sirolimus- vs paclitaxel-eluting stents, respectively, the mean (SD) in-stent late loss was 0.09 (0.43) mm vs 0.31 (0.44) mm (difference, -0.22 mm; 95% CI, -0.26 to -0.18 mm; P<.001), mean (SD) in-stent diameter stenosis was 23.1% (16.6%) vs 26.7% (15.8%) (difference, -3.60%; 95% CI, -5.12% to -2.08%; P<.001), and the number of major adverse cardiac events at 1 year was 73 (10.7%) vs 76 (11.4%) (RR, 0.94; 95% CI, 0.69-1.27; P = .73). CONCLUSION: In this trial comparing sirolimus- and paclitaxel-eluting coronary stents, there were no differences in the rates of binary restenosis or major adverse cardiac events. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT00235092.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the effects of a single preoperative dose of steroid on thyroidectomy outcomes. BACKGROUND: Nausea, pain, and voice alteration frequently occur after thyroidectomy. Because steroids effectively reduce nausea and inflammation, a preoperative administration of steroids could improve these thyroidectomy outcomes. METHODS: Seventy-two patients (men = 20, women = 52) undergoing thyroidectomy for benign disease were included in this randomized, controlled, 2 armed (group D: 8 mg dexamethasone, n = 37; group C: 0.9% NaCl, n = 35), double-blinded study (clinical trial number NCT00619086). Anesthesia, surgical procedures, antiemetics, and analgesic treatments were standardized. Nausea (0-3), pain (visual analog scale), antiemetic and analgesic requirements, and digital voice recording were documented before and 4, 8, 16, 24, 36, and 48 hours after surgery. Patients were followed-up 30 days after hospital discharge. RESULTS: Baseline characteristics were similar among the 2 treatment groups. Nausea was pronounced in the first 16 hours postoperatively (scores were <0.3 and 0.8-1.0 for group D and C, respectively (P = 0.005)), and was significantly lower in group D compared with group C during the observation period (P = 0.001). Pain diminished within 48 hours after surgery (visual analog scale 20 and 35 in group D and C, respectively (P = 0.009)). Antiemetic and analgesic requirements were also significantly diminished. Changes in voice mean frequency were less prominent in the dexamethasone group compared with the placebo group (P = 0.015). No steroid-related complications occurred. CONCLUSION: A preoperative single dose of steroid significantly reduced nausea, vomiting, and pain, and improved postoperative voice function within the first 48 hours (most pronounced within 16 hours) after thyroid resection; this strategy should be routinely applied in thyroidectomies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

STATEMENT OF PROBLEM: A tapered implant with continuously changing threads purported to provide stable tissue support and allow immediate function has been developed. Treatment success and stabilization of supporting tissues over time require documentation. PURPOSE: The purpose of this prospective, randomized, controlled, multicenter study was to evaluate changes in bone level and soft tissue behavior between the novel implant (NobelActive/NA) and a standard tapered implant (NobelReplace Tapered Groovy/NR) with regard to immediate function. MATERIAL AND METHODS: A total of 177 patients randomly allocated to 3 treatment groups (2 different test implant groups: NA Internal (n=117; internal connection) and External (n=82), and 1 standard treatment group, NR (n=126)) received 325 implants. Implants were placed into healed sites, and all but 6 implants were immediately nonocclusally loaded. Clinical and radiographic evaluations of treatment success, crestal bone levels, and soft tissue changes were performed at the time of placement and after 3, 6, and 12 months. Log-Rank test was used to analyze the differences in survival rate. Marginal bone level was compared using the Kruskal-Wallis test and Mann-Whitney U-test (alpha=.05). RESULTS: One-year cumulative survival rates were comparable (96.6% for NA Internal; 96.3% for NA External; 97.6% for NR; P=.852; Log-Rank). Mean (SD) change in bone level was -0.95 mm (1.37) for NA Internal, -0.64 mm (0.97) for NA External, and -0.63 mm (1.18) for NR (P=.589; Kruskal-Wallis). Stable soft tissues and significantly increased papilla scores (P<.001; Wilcoxon signed-rank) were observed for all implant types. CONCLUSIONS: The novel implants showed high survival rates as well as stable bone and soft tissue levels after 1 year, and may be recommended for clinical use, even under immediate function.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIMS The aim of this single-site, randomized, controlled, double-blind, 3-arm parallel study was to determine the effectiveness of a prophylaxis paste containing 15% calcium sodium phosphosilicate (CSPS; NovaMin(®) ) with and without fluoride in reducing dentine hypersensitivity immediately after a single application and 28 days following dental scaling and root planing. MATERIALS & METHODS Overall, 151 subjects were enrolled in this study. All subjects received a scaling and root planing procedure followed by a final prophylaxis step using one of three different prophylaxis pastes: Test-A (15% NovaMin(®) and NaF), Test-B (15% NovaMin(®) ) and a control. Dentine hypersensitivity was assessed by tactile stimulus (Yeaple Probe(®) ) and by air blast (Schiff scale) at baseline, immediately after and 28 days after a prophylaxis procedure. One hundred and forty-nine subjects completed the study. RESULTS Subjects having received the test prophylaxis pastes showed statistically lower (anova, p < 0.05) dentine hypersensitivity compared with the control group immediately after the prophylaxis procedure (Yeaple Probe(®) : Test-A = 20.9 ± 12.6, Test-B = 22.7 ± 12.9, Control=11.2 ± 3.1; Schiff score: Test-A = 1.1 ± 0.6, Test-B = 1.1 ± 0.6, Control = 2.0 ± 0.7) and after 28 days (Yeaple probe: Test-A = 21.5 ± 11.9, Test-B = 20.6 ± 11.3, Control = 11.8 ± 6.0; Schiff score: Test-A = 1.0 ± 0.6, Test-B = 1.0 ± 0.6, Control = 2.0 ± 0.7). CONCLUSIONS In conclusion, the single application of both fluoridated and non-fluoridated prophylaxis pastes containing 15% CSPS (NovaMin(®) ) provided a significant reduction of dentine hypersensitivity up to at least 28 days.