138 resultados para Perceptual closure


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two young women with angiographically normal coronary arteries suffered an acute myocardial infarction. Both were found to have a patent foramen ovale (PFO), the likely pathway of a paradoxical embolus causing the infarction. The PFOs were diagnosed and closed percutaneously with an Amplatzer PFO Occluder during the emergency coronary angiography.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The effectiveness of various appendiceal stump closure methods has not been evaluated systematically. The aim of this study was to compare the morbidity of stump closure by stapling or use of endoloops. METHODS: A non-concurrent cohort study of prospectively acquired data was performed. The primary outcome variable was the rate of intra-abdominal surgical-site infection. Secondary outcome measures were complications, duration of intervention, hospital stay, rate of readmission to hospital and the difference in direct costs of the operation. RESULTS: Staples were used in 60.5 per cent and endoloops in 39.5 per cent of 6486 patients operated on for suspected appendicitis between January 1995 and December 2003. Among 4489 patients with acute appendicitis the rate of intra-abdominal surgical-site infection was 0.7 per cent in the stapler group and 1.7 per cent in the endoloop group (P = 0.004). The rate of readmission to hospital was 0.9 and 2.1 per cent respectively (P = 0.001). CONCLUSION: Application of a stapler for transection and closure of the appendiceal stump in patients with acute appendicitis lowered the risk of postoperative intra-abdominal surgical-site infection and the need for readmission to hospital.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Aim of the study was to correlate urethral retro resistance pressure with the maximum urethral closure pressure (MUCP) and functional urethral length (FUL) in patients with urinary incontinence and healthy individuals. STUDY DESIGN: Two hundred and twenty patients with the complaint of urinary incontinence had a urodynamic examination including urethral pressure profiles and URP. Additionally, 15 healthy individuals without the complaint of any incontinence had their URP and urethral pressure profiles measured. The correlation of MUCP, FUL and URP were calculated using Graph Pad Instat 4.0 for windows. RESULTS: URP correlates well with the diagnosis of urodynamic stress incontinence. Correlation coefficient between URP and MUCP is 0.9262. Healthy individuals have significantly higher values for URP and MUCP. CONCLUSION: URP is a valuable less invasive test than conventional urethral function tests for the diagnosis of urodynamic incontinence with an excellent correlation of MUCP and URP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The presence of irreversible pulmonary hypertension in patients with atrial septal defect (ASD) is thought to preclude shunt closure. We report the case of a woman with plexiform pulmonary arteriopathy secondary to an ostium secundum ASD who was able to successfully undergo percutaneous shunt closure following therapy with chronic intravenous prostacyclin (Flolan). One year after closure, the patient was weaned off Flolan over a period of 7 months following the institution of oral Bosentan therapy. Our case illustrates how aggressive vasodilator therapy with prostaglandins may be capable of reducing pulmonary artery pressure and permitting shunt closure in a patient once considered to have "inoperable" pulmonary arteriopathy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The primary visual cortex (V1) is pre-wired to facilitate the extraction of behaviorally important visual features. Collinear edge detectors in V1, for instance, mutually enhance each other to improve the perception of lines against a noisy background. The same pre-wiring that facilitates line extraction, however, is detrimental when subjects have to discriminate the brightness of different line segments. How is it possible to improve in one task by unsupervised practicing, without getting worse in the other task? The classical view of perceptual learning is that practicing modulates the feedforward input stream through synaptic modifications onto or within V1. However, any rewiring of V1 would deteriorate other perceptual abilities different from the trained one. We propose a general neuronal model showing that perceptual learning can modulate top-down input to V1 in a task-specific way while feedforward and lateral pathways remain intact. Consistent with biological data, the model explains how context-dependent brightness discrimination is improved by a top-down recruitment of recurrent inhibition and a top-down induced increase of the neuronal gain within V1. Both the top-down modulation of inhibition and of neuronal gain are suggested to be universal features of cortical microcircuits which enable perceptual learning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To carry out long-term follow-up after percutaneous closure of patent foramen ovale (PFO) in patients with cryptogenic stroke. DESIGN: Prospective cohort study. SETTING: Single tertiary care centre. PARTICIPANTS: 525 consecutive patients (mean (SD) age 51 (12) years; 56% male). INTERVENTIONS: Percutaneous PFO closure without intraprocedural echocardiography. MAIN OUTCOME MEASURES: Freedom from recurrent embolic events. RESULTS: A mean (SD) of 1.7 (1.0) clinically apparent embolic events occurred for each patient, and 186 patients (35%) had >1 event. An atrial septal aneurysm was associated with the PFO in 161 patients (31%). All patients were followed up prospectively for up to 11 years. The implantation procedure failed in two patients (0.4%). There were 13 procedural complications (2.5%) without any long-term sequelae. Contrast transoesophageal echocardiography at 6 months showed complete closure in 86% of patients, and a minimal, moderate or large residual shunt in 9%, 3% and 2%, respectively. Patients with small occluders (<30 mm; n = 429) had fewer residual shunts (small 11% vs large 27%; p<0.001). During a mean (SD) follow-up of 2.9 (2.2) years (median 2.3 years; total 1534 patient-years), six ischaemic strokes, nine transient ischaemic attacks (TIAs) and two peripheral emboli occurred. Freedom from recurrent stroke, TIA, or peripheral embolism was 98% at 1 year, 97% at 2 years and 96% at 5 and 10 years, respectively. A residual shunt (hazard ratio = 3.4; 95% CI 1.3 to 9.2) was a risk factor for recurrence. CONCLUSIONS: This study attests to the long-term safety and efficacy of percutaneous PFO closure guided by fluoroscopy only for secondary prevention of paradoxical embolism in a large cohort of consecutive patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The value of incidental coronary angiography during percutaneous shunt closure to screen for asymptomatic coronary artery disease (CAD) is unknown. METHODS: On the occasion of percutaneous closure of patent foramen ovale (PFO), incidental coronary angiography routinely offered to men >40 and women >50 years, or younger patients with particular risk patterns, was performed in 575 patients (64% men, mean age 55 +/- 10 years, mean 1.5 +/- 1.1 cardiovascular risk factors) without overt history, signs, or symptoms of CAD. RESULTS: CAD was found in 164 patients (29%); 53 (9%) had >or=50% diameter stenoses. Thirty patients (5%) had one-vessel, 13 (2%) two-vessel, and 10 (2%) three-vessel disease. Patients with CAD (n = 164) were older (60 +/- 9 vs. 53 +/- 10 years; P < 0.0001), more frequently male (76% vs. 59%; P = 0.0002), and had a higher body mass index (26.5 +/- 4.0 vs. 25.4 +/- 4.6; P = 0.006) and more cardiovascular risk factors (2.0 +/- 1.1 vs. 1.2 +/- 1.0; P < 0.0001). There were six procedural complications (1%). Two were unequivocally related to coronary angiography: one minor stroke (diplopia), and one iatrogenic dissection of the right coronary ostium requiring stenting. Furthermore, four arteriovenous fistulae at the puncture site requiring elective surgical closure were possibly related to coronary angiography. Forty-five patients (8% of total) underwent percutaneous (n = 43) or surgical (n = 2) revascularization. CONCLUSIONS: In selected asymptomatic patients referred for percutaneous PFO closure, incidental coronary angiography discloses a rather high prevalence of clinically unsuspected CAD. These findings are relevant not only for timely revascularization but also for maintenance of long-term antiplatelet therapy beyond the few months recommended after PFO closure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Migraine is a recurrent disabling disorder predominantly affecting middle-aged women. Migraine occurs with or without aura symptoms. Several studies have shown an increased prevalence of right-to-left shunts (RLSs) in migraine with aura. The overwhelming majority of these shunts were due to a patent foramen ovale (PFO). Furthermore, migraine with aura is more prevalent in clinical entities associated with a RLS, e.g. cryptogenic stroke, decompression illness in divers, or in patients with hereditary hemorrhagic teleangiectasia and pulmonary arteriovenous fistulas. Retrospective studies have consistently shown that shunt closure was associated with a significant reduction in migraine frequency. Its beneficial effect seemed to exceed the efficacy of conventional migraine therapy. Several randomized clinical trials to prospectively assess the benefit of shunt closure in migraine patients have been initiated. The only one completed, the MIST trial (Migraine Intervention with STARFLEX Technology), showed a significant reduction of migraine with aura after device implantation, compared with controls. However, the benefit of PFO closure was more modest than expected. This review recapitulates the current data regarding PFO closure and migraine with aura and summarizes in brief the current knowledge regarding migraine pathophysiology and the link to a RLS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In four experiments we investigated whether incidental task sequence learning occurs when no instructional task cues are available (i.e. with univalent stimuli). We manipulated task sequence by presenting three simple binary-choice tasks (colour, form or letter case decisions) in regular repeated or random order. Participants were required to use the same two response keys for each of the tasks. We manipulated response sequence by ordering the stimuli so as to produce either a regular or a random order of left versus right-hand key presses. When sequencing in both, or either, separate stream (i.e. task sequence and/or response sequence) was changed to random, only those participants who had processed both sequences together showed evidence of sequence learning in terms of significant response time disruption (Experiments 1-3). This effect disappeared when the sequences were uncorrelated (Experiment 4). The results indicate that only the correlated integration of task sequence and response sequence produced a reliable incidental learning effect. As this effect depends on the predictable ordering of stimulus categories, it suggests that task sequence learning is perceptual rather than conceptual in nature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A patent foramen ovale (PFO) is a common finding present in 25% of the population. A relationship between PFO and several clinical conditions such as stroke, migraine, platypnea-orthodeoxia syndrome, neurological decompression illness in divers, high altitude pulmonary edema, sleep apnea, and economy class syndrome have been documented. Observational non-randomized studies have shown percutaneous PFO closure more effective than medical treatment for stroke prevention, in particular in patients with complete closure as well as in patients with more than one cerebrovascular event at baseline. In the case of migraine, PFO closure has been shown to result in a marked reduction in migraine burden or migraine days. PFO anatomy, epidemiological data on associated clinical conditions, comparison between percutaneous closure and medical treatment, as well as the technical aspect of the procedure are described in this review.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several divergent cortical mechanisms generating multistability in visual perception have been suggested. Here, we investigated the neurophysiologic time pattern of multistable perceptual changes by means of a simultaneous recording with electroencephalography (EEG) and functional magnetic resonance imaging (fMRI). Volunteers responded to the subjective perception of a sudden change between stable patterns of illusionary motion (multistable transition) during a stroboscopic paradigm. We found a global deceleration of the EEG frequency prior to a transition and an occipital-accentuated acceleration after a transition, as obtained by low-resolution electromagnetic tomography analysis (LORETA) analysis. A decrease in BOLD response was found in the prefrontal cortex before, and an increase after the transitions was observed in the right anterior insula, the MT/V5 regions and the SMA. The thalamus and left superior temporal gyrus showed a pattern of decrease before and increase after transitions. No such temporal course was found in the control condition. The multimodal approach of data acquisition allows us to argue that the top-down control of illusionary visual perception depends on selective attention, and that a diminution of vigilance reduces selective attention. These are necessary conditions to allow for the occurrence of a perception discontinuity in absence of a physical change of the stimulus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This EEG study was performed to clarify the time course of brain electrical events and possible vigilance changes associated with perceptual flips during multistable perception. 13 healthy subjects (28.5 3.8 years) were recorded with a 21-channel digital EEG during a stroboscopic alternative motion paradigm implying illusionary motion with ambiguous direction. Perceptual flips were preceded by a significant decrease of EEG frequencies, and followed by a significant frequency increase with a trend to overshoot. EEG slowing is a reliable sign of vigilance decrease and can be related to thalamic deactivation. This is consistent with a recent fMRI study, which showed thalamic deactivation associated with perceptual flips. The study added important chronological information about this phenomenon and allows the conclusion that reduced vigilance facilitates perceptual discontinuities during multistable perception.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This randomized trial compared procedural complications and 30-day clinical outcomes of 3 patent foramen ovale (PFO) closure devices (Amplatzer, Helex, and CardioSEAL-STARflex). It examined 660 patients (361 men, 299 women, mean age 49.3+/-1.9 years), with 220 patients per group. All patients had a history of paradoxical embolism. All PFO closures were successful technically. Exchange of devices for others was most frequently required for the Helex occluder (7 of 220) and 2 of 220 in either of the other groups. Three device embolizations in the Helex group were retrieved and replaced successfully. One patient with a Helex occluder developed a transient ischemic attack and recovered without treatment. A hemopericardium in that group was punctured without affecting the device. One tamponade in the Amplatzer group required surgical device explantation. In 8 of 660 patients in the CardioSEAL-STARflex group, thrombi resolved after anticoagulation. Sixteen patients (11 in the CardioSEAL-STARflex group, 3 in the Amplatzer group, and 2 in the Helex group) had episodes of atrial fibrillation. PFOs were closed completely in 143 of 220 patients (65%) in the Amplatzer group, 116 of 220 patients (52.7%) in the Helex group, and 137 of 220 patients (62.3%) in the CardioSEAL-STARflex group at 30 days with significant differences between the Helex and Amplatzer occluders (p=0.0005) and the Helex and CardioSEAL-STARflex occluders (p=0.0003). PFO closure can be performed safely with each device. In conclusion, the Helex occluder embolized more frequently. Device thrombus formation and paroxysmal atrial fibrillation were more common with the CardioSEAL-STARflex occluder.