64 resultados para PERMANENT PACEMAKER


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to compare the performance of the DIAGNOdent 2095 with visual examination for occlusal caries detection in permanent and primary molars. The sample comprised 148 permanent human molars and 179 primary human molars. The samples were measured and visually examined three times by two examiners. After measurement, the teeth were histologically prepared and assessed for caries extension. Sensitivity, specificity, accuracy and area under the receiver operating characteristics (ROC) curve were calculated. Intra-class correlation (ICC), unweighted kappa and the Bland and Altman method were used to assess inter- and intra-examiner reproducibility. DIAGNOdent showed higher specificity and lower sensitivity than did visual examination. The ICC values indicated an excellent agreement between the examinations. Kappa values varied from good to excellent for DIAGNOdent but from poor to good for visual examination. In conclusion, the DIAGNOdent may be a useful adjunct to conventional methods for occlusal caries detection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Inflammatory bowel disease can decrease the quality of life and induce work disability. We sought to (1) identify and quantify the predictors of disease-specific work disability in patients with inflammatory bowel disease and (2) assess the suitability of using cross-sectional data to predict future outcomes, using the Swiss Inflammatory Bowel Disease Cohort Study data. METHODS A total of 1187 patients were enrolled and followed up for an average of 13 months. Predictors included patient and disease characteristics and drug utilization. Potential predictors were identified through an expert panel and published literature. We estimated adjusted effect estimates with 95% confidence intervals using logistic and zero-inflated Poisson regression. RESULTS Overall, 699 (58.9%) experienced Crohn's disease and 488 (41.1%) had ulcerative colitis. Most important predictors for temporary work disability in patients with Crohn's disease included gender, disease duration, disease activity, C-reactive protein level, smoking, depressive symptoms, fistulas, extraintestinal manifestations, and the use of immunosuppressants/steroids. Temporary work disability in patients with ulcerative colitis was associated with age, disease duration, disease activity, and the use of steroids/antibiotics. In all patients, disease activity emerged as the only predictor of permanent work disability. Comparing data at enrollment versus follow-up yielded substantial differences regarding disability and predictors, with follow-up data showing greater predictor effects. CONCLUSIONS We identified predictors of work disability in patients with Crohn's disease and ulcerative colitis. Our findings can help in forecasting these disease courses and guide the choice of appropriate measures to prevent adverse outcomes. Comparing cross-sectional and longitudinal data showed that the conduction of cohort studies is inevitable for the examination of disability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Today’s medical devices are powered by batteries with a limited energy storage capacity. Depleted batteries have to be replaced, exposing the patients to the risk of adverse events. Thus, a method for harvesting energy inside the body is desirable since it would allow building devices without batteries. Methods: A miniaturized intravascular Tesla turbine was implanted as an arteriovenous shunt between the common carotid artery and external jugular vein of a pig. The harvested energy was used to power a custom-built temporary cardiac pacemaker. Results: At a flow rate of ~150 ml/min, an output power of 0.4 mW was measured. Successful ventricular pacing was performed. Conclusion: Harvesting energy from the circulation using an intravascular turbine is technically feasible and provides enough energy to power a cardiac pacemaker.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A compact adjustable focusing system for a 2 MeV H- RFQ Linac is designed, constructed and tested based on four permanent magnet quadrupoles (PMQ). A PMQ model is realised using finite element simulations, providing an integrated field gradient of 2.35 T with a maximal field gradient of 57 T/m. A prototype is constructed and the magnetic field is measured, demonstrating good agreement with the simulation. Particle track simulations provide initial values for the quadrupole positions. Accordingly, four PMQs are constructed and assembled on the beam line, their positions are then tuned to obtain a minimal beam spot size of (1.2 x 2.2) mm^2 on target. This paper describes an adjustable PMQ beam line for an external ion beam. The novel compact design based on commercially available NdFeB magnets allows high flexibility for ion beam applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 13-year-old male neutered domestic shorthaired cat had repeated syncopal episodes over a 6 month period, which had variable duration and continued to increase in frequency. Intermittent ventricular asystole, due to complete heart block, and hyperthyroidism were documented. As the syncopal episodes did not respond to a 4-week medical treatment and symptoms became severe, a transvenous ventricular demand pacemaker system (VVIM) was implanted via the external jugular vein. The unipolar lead was tunneled subcutaneously and connected with the generator in a preformed ventral abdominal muscle pocket. During follow up of 18-months there were no recurrences of the syncopal episodes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To evaluate the effects of salivary contamination and decontamination on bond strength of two one-step adhesives to primary and permanent dentin. Methods: Dentin specimens were prepared from extracted primary and permanent molars (210 of each) and were distributed to seven groups (n=15/group/molar type) for each adhesive (Xeno V+ and Scotchbond Universal): no saliva contamination (control); saliva contamination before or after light-curing of the adhesives followed either by air-drying, by rinsing with water and air-drying, or by rinsing with water, air-drying and reapplication of the adhesives. Resin composite was applied and the specimens were stored for 24h (37°C, 100% humidity). Then, shear bond strength (SBS) was measured and data analyzed with nonparametric ANOVA and Wilcoxon rank sum tests. Results: Saliva contamination reduced SBS of Xeno V+, the reduction being more pronounced when contamination occurred before light-curing than after. In both situations, decontamination involving reapplication of the adhesive restored SBS. Saliva contamination had no significant effect on Scotchbond Universal. There were no differences in SBS between primary and permanent teeth. Conclusion: Saliva contamination reduced SBS of Xeno V+, but not of Scotchbond Universal. SBS was restored when contaminated dentin was rinsed with water and air-dried followed by reapplication of the adhesive.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the effects of human saliva contamination and two decontamination procedures at different stages of the bonding procedure on the bond strength of two one-step self-etching adhesives to primary and permanent dentin. Materials and Methods: Extracted human primary and permanent molars (210 of each) were ground to mid-coronal dentin. The dentin specimens were randomly divided into 7 groups (n = 15/group/molar type) for each adhesive (Xeno V+ and Scotchbond Universal): no saliva contamination (control); saliva contamination before or after light curing of the adhesives followed by air drying, rinsing with water spray/air drying, or by rinsing with water spray/air drying/reapplication of the adhesives. Resin composite (Filtek Z250) was applied on the treated dentin surfaces. The specimens were stored at 37°C and 100% humidity for 24 h. After storage, shear bond strength (SBS) was measured and data analyzed with nonparametric ANOVA followed by exact Wilcoxon rank sum tests. Results: Xeno V+ generated significantly higher SBS than Scotchbond Universal when no saliva contamination occurred. Saliva contamination reduced SBS of Xeno V+, with the reduction being more pronounced when contamination occurred before light curing than after. In both situations, decontamination involving reapplication of the adhesive restored SBS. Saliva contamination had no significant effect on Scotchbond Universal. There were no differences in SBS between primary and permanent teeth. Conclusion: Rinsing with water and air drying followed by reapplication of the adhesive restored bond strength to saliva-contaminated dentin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS Today's cardiac pacemakers are powered by batteries with limited energy capacity. As the battery's lifetime ends, the pacemaker needs to be replaced. This surgical re-intervention is costly and bears the risk of complications. Thus, a pacemaker without primary batteries is desirable. The goal of this study was to test whether transcutaneous solar light could power a pacemaker. METHODS AND RESULTS We used a three-step approach to investigate the feasibility of sunlight-powered cardiac pacing. First, the harvestable power was estimated. Theoretically, a subcutaneously implanted 1 cm(2) solar module may harvest ∼2500 µW from sunlight (3 mm implantation depth). Secondly, ex vivo measurements were performed with solar cells placed under pig skin flaps exposed to a solar simulator and real sunlight. Ex vivo measurements under real sunlight resulted in a median output power of 4941 µW/cm(2) [interquartile range (IQR) 3767-5598 µW/cm(2), median skin flap thickness 3.0 mm (IQR 2.7-3.3 mm)]. The output power strongly depended on implantation depth (ρSpearman = -0.86, P < 0.001). Finally, a batteryless single-chamber pacemaker powered by a 3.24 cm(2) solar module was implanted in vivo in a pig to measure output power and to pace. In vivo measurements showed a median output power of >3500 µW/cm(2) (skin flap thickness 2.8-3.84 mm). Successful batteryless VVI pacing using a subcutaneously implanted solar module was performed. CONCLUSION Based on our results, we estimate that a few minutes of direct sunlight (irradiating an implanted solar module) allow powering a pacemaker for 24 h using a suitable energy storage. Thus, powering a pacemaker by sunlight is feasible and may be an alternative energy supply for tomorrow's pacemakers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM To evaluate the performance of a pen‑type laser fluorescence device (DIAGNOdent 2190; LFpen, KaVo, Germany) and bitewing radiographs (BW) for approximal caries detection in permanent and primary teeth. MATERIALS AND METHODS A total of 246 anterior approximal surfaces (102 permanent and 144 primary) were selected. Contact points were simulated using sound teeth. Two examiners assessed all approximal surfaces using LFpen and BW. The teeth were histologically assessed for the reference standard. Optimal cut‑off limits were calculated for LFpen for primary and permanent teeth. Sensitivity, specificity, accuracy and area under the receiver operating characteristic curve (Az) were calculated for D1 (enamel and dentin lesions) and D3 (dentin lesions) thresholds. The reproducibility was assessed by intraclass correlation coefficient (ICC) and Cohen's weighted kappa values. RESULTS For permanent teeth, the LFpen cut‑off were 0- 27 (sound), 28- 33 (enamel caries) and >33 (dentin caries). For primary teeth, the LFpen cut‑off were 0- 7 (sound), 8- 32 (enamelcaries) and >32 (dentin caries). The LFpen presented higher sensitivity values than BW for primary teeth (0.58 vs. 0.32 at D1 and 0.80 vs. 0.47 at D3) and permanent teeth (0.80 vs. 0.57 at D1 and 0.94 vs. 0.51 at D3). Specificity did not show a significant difference between the methods. Rank correlations with histology were 0.59 and 0.83 (LFpen) and 0.36 and 0.70 (BW) for primary and permanent teeth, respectively, considering all lesions. ICC values for LFpen were 0.71 (inter) and 0.86 (intra) for permanent teeth and 0.94 (inter) and 0.90/0.99 for primary teeth. Kappa values for BW were 0.69 (inter) and 0.68/0.90 (intra) for permanent teeth and 0.64 (inter) and 0.89/0.89 for primary teeth. CONCLUSION LFpen presented better reproducibility for primary and permanent teeth and higher accuracy in detecting caries lesions at D1 threshold than BW for permanent teeth. LFpen should be used as an adjunct method for approximal caries detection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Contemporary pacemakers (PMs) are powered by primary batteries with a limited energy-storing capacity. PM replacements because of battery depletion are common and unpleasant and bear the risk of complications. Batteryless PMs that harvest energy inside the body may overcome these limitations. OBJECTIVE: The goal of this study was to develop a batteryless PM powered by a solar module that converts transcutaneous light into electrical energy. METHODS: Ex vivo measurements were performed with solar modules placed under pig skin flaps exposed to different irradiation scenarios (direct sunlight, shade outdoors, and indoors). Subsequently, 2 sunlight-powered PMs featuring a 4.6-cm2 solar module were implanted in vivo in a pig. One prototype, equipped with an energy buffer, was run in darkness for several weeks to simulate a worst-case scenario. RESULTS: Ex vivo, median output power of the solar module was 1963 μW/cm2 (interquartile range [IQR] 1940-2107 μW/cm2) under direct sunlight exposure outdoors, 206 μW/cm2 (IQR 194-233 μW/cm2) in shade outdoors, and 4 μW/cm2 (IQR 3.6-4.3 μW/cm2) indoors (current PMs use approximately 10-20 μW). Median skin flap thickness was 4.8 mm. In vivo, prolonged SOO pacing was performed even with short irradiation periods. Our PM was able to pace continuously at a rate of 125 bpm (3.7 V at 0.6 ms) for 1½ months in darkness. CONCLUSION: Tomorrow's PMs might be batteryless and powered by sunlight. Because of the good skin penetrance of infrared light, a significant amount of energy can be harvested by a subcutaneous solar module even indoors. The use of an energy buffer allows periods of darkness to be overcome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La forêt primaire de la région de Mandraka a été classée par le gouvernement en station forestière pour être conservée et restaurée. Suite à cette décision, tous prélèvements y sont interdits. Pourtant, aucune étude n’a évalué sa viabilité depuis cette restriction. Ce mémoire a ainsi comme objectif l’estimation de cette viabilité par le suivi permanent de l’état actuel de la forêt comprenant la végétation, la biodiversité et les pressions. La collecte de données y afférentes a eu recours à une étude bibliographique, à des enquêtes socio-économiques, à un inventaire des pressions, à un inventaire forestier et à une distance sampling. L’état a été évalué par l’analyse de ces composants. Cette recherche a fait ressortir que la forêt est soumise à des pressions anthropiques et biologiques : coupes illicites, collecte de Dioscorea sp., feux de forêt, envahissement des lianes. Ces pressions ont réduit la superficie de la forêt, modifié sa structure et celle de la faune : les régénérations naturelles sont abondantes, les arbres émergents et de diamètre supérieur à 40 cm sont rares, certaines essences floristiques et les lémuriens risquent de disparaître. Puis, les lianes remplacent successivement la forêt. Malgré ces pressions, la forêt a pu conserver certaines caractéristiques de son état originel : l’abondance élevée des tiges et la réduction de leur taille sur les crêtes, l’allure exponentielle de la structure totale, la présence des genres Tambourissa et Weinmannia. En outre, la forêt est encore riche en avifaune. Après analyse de viabilité, elle est classée comme un écosystème viable. Mais ces potentialités sont insuffisantes : il faut réduire les pressions et reconstituer la forêt pour une meilleure conservation de l’écosystème. A cet effet, la présente étude suggère l’aménagement, en premier lieu de la forêt par des interventions sylvicoles favorisant les régénérations comme l’enrichissement en placeaux, le délianage et en second lieu, celui de ses environs par des vulgarisations d’activités génératrices de revenu autres que l’exploitation des forêts naturelles telles l’agroforesterie, le reboisement, l’apiculture. Des patrouilles fréquentes et une délimitation de la station forestière s’avèrent aussi nécessaires.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mandraka possède de nombreux écosystèmes, dominés surtout par les forêts. Cette zone est située sur la première falaise orientale malgache et affiche des reliefs accidentés (pentes supérieures à 60%). Elle est exposée à un régime climatique à forte influence orientale se traduisant par une humidité permanente et un régime cyclonique fréquent. Les paramètres stationnels sont ainsi rudes, or ils sont écologiquement très importants car plusieurs caractéristiques physionomiques et comportementales des espèces forestières en dépendent. Cette étude s'intéresse à la station forestière de Mandraka, particulièrement à l'arboretum. Ce dernier fût créé dans les années cinquante et est actuellement géré par le Département des Eaux et Forêts. Ce site est actuellement à vocation pédagogique et écotouristique. Son état écologique est inconnu jusqu'à maintenant, et depuis sa création, aucun système n'a été mis en place pour mesurer et suivre sa viabilité. D'où, l'intitulé de ce travail de mémoire : « Définition d'un état zéro et mise en place d'un système de suivi écologique permanent de l'arboretum de la station forestière de Mandraka ». Les objectifs étant de collecter des données concernant l'état écologique actuel du site, d'identifier des indicateurs de suivi pour mesurer sa viabilité, et d'inclure un système de suivi écologique permanent dans une proposition de plan d'aménagement pour l'arboretum. Le suivi est en effet un outil très important pour l'analyse des ressources forestières. Il permet de cadrer toutes les interventions. Les diverses analyses menées lors de cette étude ont révélé une viabilité moyenne de l'arboretum. Cela est induit par une qualité de peuplement moyennement stable, une mortalité élevée (plus de 14%), et un potentiel d'avenir très faible, voire inexistant (taux de régénération à 0%). L'envahissement de la forêt artificielle par les espèces autochtones constitue la pression la plus importante de cet arboretum vu qu'il se trouve au milieu des forêts naturelles. L'analyse sylvicole effectuée sur les deux types dendrologiques révèle que les peuplements de conifères présentent des caractéristiques sylvicoles plus favorables que les feuillus. Ce niveau moyen de viabilité de l'arboretum implique ainsi la proposition d'un plan d'aménagement pour l'améliorer; le suivi est une activité primordiale, d'où la proposition d'un plan de suivi permanent pour l'arboretum. A noter que malgré la considération du critère de représentativité pour l'échantillonnage, toutes les questions ne pourront être répondues du fait que plusieurs mosaïques de peuplements artificiels de différentes espèces constituent l'arboretum, et que chacune de ces espèces plantées ont leurs propres caractéristiques. La mise en place des plots permanents d'observation ne servira ainsi que de référence (Etat zéro), mais on propose de prévoir un suivi intégral ainsi que diverses interventions pour l'arboretum en général. Ce travail constitue ainsi une base de données pour l'arboretum et pour la station forestière de Mandraka, mais il ne représente qu'une des facettes à prendre en considération dans une finalité d'amélioration de la viabilité. L'élaboration de cartes thématiques et d'évolution spatio-temporelle à l'issue de SIG (Système d'Information Géographique) permettra d'enrichir les informations établies et admettra un suivi plus précis.