57 resultados para Mini-plates
Resumo:
The aim of this study was to investigate potential occurrence of bacteremia in orthodontic patients after removal of miniscrews.The study group comprised 30 healthy subjects (17 males, 13 females) with a mean age of 24.1 years treated with self-ligating fixed appliances and mini-implant anchorage. Two 20 ml venous blood samples were obtained prior to and 30-60 seconds after miniscrew explantation following an aseptic technique. Blood culturing in aerobic and anaerobic conditions was carried out by means of the BACTEC blood culture analyzer. Microbiological analysis showed that none of the pre- and post-operative samples exhibited detectable bacteremia. Future research should be focused on determining the collective bacteremic effect of a sequence of orthodontic procedures including miniscrew placement or removal, typically performed during a single treatment session.
Resumo:
OBJECTIVES The generation of learning goals (LGs) that are aligned with learning needs (LNs) is one of the main purposes of formative workplace-based assessment. In this study, we aimed to analyse how often trainer–student pairs identified corresponding LNs in mini-clinical evaluation exercise (mini-CEX) encounters and to what degree these LNs aligned with recorded LGs, taking into account the social environment (e.g. clinic size) in which the mini-CEX was conducted. METHODS Retrospective analyses of adapted mini-CEX forms (trainers’ and students’ assessments) completed by all Year 4 medical students during clerkships were performed. Learning needs were defined by the lowest score(s) assigned to one or more of the mini-CEX domains. Learning goals were categorised qualitatively according to their correspondence with the six mini-CEX domains (e.g. history taking, professionalism). Following descriptive analyses of LNs and LGs, multi-level logistic regression models were used to predict LGs by identified LNs and social context variables. RESULTS A total of 512 trainers and 165 students conducted 1783 mini-CEXs (98% completion rate). Concordantly, trainer–student pairs most often identified LNs in the domains of ‘clinical reasoning’ (23% of 1167 complete forms), ‘organisation/efficiency’ (20%) and ‘physical examination’ (20%). At least one ‘defined’ LG was noted on 313 student forms (18% of 1710). Of the 446 LGs noted in total, the most frequently noted were ‘physical examination’ (49%) and ‘history taking’ (21%). Corresponding LNs as well as social context factors (e.g. clinic size) were found to be predictors of these LGs. CONCLUSIONS Although trainer–student pairs often agreed in the LNs they identified, many assessments did not result in aligned LGs. The sparseness of LGs, their dependency on social context and their partial non-alignment with students’ LNs raise questions about how the full potential of the mini-CEX as not only a ‘diagnostic’ but also an ‘educational’ tool can be exploited.
Resumo:
Background: Defining learning goals (LG) in alignment with learning needs (LN) is one of the key purposes of formative workplace-based assessment, but studies about this topic are scarce. Summary of Work: We analysed quantitatively and qualitatively how often trainer-student pairs identified the same LN during Mini Clinical Evaluation Exercises (Mini-CEX) in clerkships and to what degree those LNs were in line with the recorded LGs. Multilevel logistic regression models were used to predict LGs by identified LNs, controlling for context variables. Summary of Results: 512 trainers and 165 students conducted 1783 Mini-CEX (98% completion rate). Concordantly, trainer-student pairs most often identified LNs in the domains ‘clinical reasoning’ (23% of 1167 complete forms), ‘organisation / efficiency’ (20%) and ‘physical examination’ (20%). At least one ‘defined’ LG was noted on 313 student forms (18% of 1710), with a total of 446 LGs. Of these, the most frequent LGs were ‘physical examination’ (49% of 446 LGs) and ‘history taking’ (21%); corresponding LNs as well as context variables (e.g. clinic size) were found to be predictors of these LGs. Discussion and Conclusions: Although trainer-student pairs often agreed in their identified LNs, many assessments did not result in an aligned LG or a LG at all. Interventions are needed to enhance the proportion of (aligned) LGs in Mini-CEX in order to tap into its full potential not only as a ‘diagnostic’ but also as an ‘educational tool’. Take-home messages: The sparseness of LGs, their dependency on context variables and their partial non-alignment with students’ LNs raise the question of how the effectiveness of Mini-CEX can be further enhanced.
Resumo:
Procurement of fresh tissue of prostate cancer is critical for biobanking and generation of xenograft models as an important preclinical step towards new therapeutic strategies in advanced prostate cancer. However, handling of fresh radical prostatectomy specimens has been notoriously challenging given the distinctive physical properties of prostate tissue and the difficulty to identify cancer foci on gross examination. Here, we have developed a novel approach using ceramic foam plates for processing freshly cut whole mount sections from radical prostatectomy specimens without compromising further diagnostic assessment. Forty-nine radical prostatectomy specimens were processed and sectioned from the apex to the base in whole mount slices. Putative carcinoma foci were morphologically verified by frozen section analysis. The fresh whole mount slices were then laid between two ceramic foam plates and fixed overnight. To test tissue preservation after this procedure, formalin-fixed and paraffin-embedded whole mount sections were stained with hematoxylin and eosin (H&E) and analyzed by immunohistochemistry, fluorescence, and silver in situ hybridization (FISH and SISH, respectively). There were no morphological artifacts on H&E stained whole mount sections from slices that had been fixed between two plates of ceramic foam, and the histological architecture was fully retained. The quality of immunohistochemistry, FISH, and SISH was excellent. Fixing whole mount tissue slices between ceramic foam plates after frozen section examination is an excellent method for processing fresh radical prostatectomy specimens, allowing for a precise identification and collection of fresh tumor tissue without compromising further diagnostic analysis.
Resumo:
The important task to observe the global coverage of middle atmospheric trace gases like water vapor or ozone usually is accomplished by satellites. Climate and atmospheric studies rely upon the knowledge of trace gas distributions throughout the stratosphere and mesosphere. Many of these gases are currently measured from satellites, but it is not clear whether this capability will be maintained in the future. This could lead to a significant knowledge gap of the state of the atmosphere. We explore the possibilities of mapping middle atmospheric water vapor in the Northern Hemisphere by using Lagrangian trajectory calculations and water vapor profile data from a small network of five ground-based microwave radiometers. Four of them are operated within the frame of NDACC (Network for the Detection of Atmospheric Composition Change). Keeping in mind that the instruments are based on different hardware and calibration setups, a height-dependent bias of the retrieved water vapor profiles has to be expected among the microwave radiometers. In order to correct and harmonize the different data sets, the Microwave Limb Sounder (MLS) on the Aura satellite is used to serve as a kind of traveling standard. A domain-averaging TM (trajectory mapping) method is applied which simplifies the subsequent validation of the quality of the trajectory-mapped water vapor distribution towards direct satellite observations. Trajectories are calculated forwards and backwards in time for up to 10 days using 6 hourly meteorological wind analysis fields. Overall, a total of four case studies of trajectory mapping in different meteorological regimes are discussed. One of the case studies takes place during a major sudden stratospheric warming (SSW) accompanied by the polar vortex breakdown; a second takes place after the reformation of stable circulation system. TM cases close to the fall equinox and June solstice event from the year 2012 complete the study, showing the high potential of a network of ground-based remote sensing instruments to synthesize hemispheric maps of water vapor.
Resumo:
Background Locking compression plates are used in various configurations with lack of detailed information on consequent bone healing. Study design In this in vivo study in sheep 5 different applications of locking compression plate (LCP) were tested using a 45° oblique osteotomy simulating simple fracture pattern. 60 Swiss Alpine sheep where assigned to 5 different groups with 12 sheep each (Group 1: interfragmentary lag screw and an LCP fixed with standard cortex screws as neutralisation plate; Group 2: interfragmentary lag screw and LCP with locking head screws; Group 3: compression plate technique (hybrid construct); Group 4: internal fixator without fracture gap; Group 5: internal fixator with 3 mm gap at the osteotomy site). One half of each group (6 sheep) was monitored for 6 weeks, and the other half (6 sheep) where followed for 12 weeks. Methods X-rays at 3, 6, 9 and 12 weeks were performed to monitor the healing process. After sacrifice operated tibiae were tested biomechanically for nondestructive torsion and compared to the tibia of the healthy opposite side. After testing specimens were processed for microradiography, histology, histomorphometry and assessment of calcium deposition by fluorescence microscopy. Results In all groups bone healing occurred without complications. Stiffness in biomechanical testing showed a tendency for higher values in G2 but results were not statistically significant. Values for G5 were significantly lower after 6 weeks, but after 12 weeks values had improved to comparable results. For all groups, except G3, stiffness values improved between 6 and 12 weeks. Histomorphometrical data demonstrate endosteal callus to be more marked in G2 at 6 weeks. Discussion and conclusion All five configurations resulted in undisturbed bone healing and are considered safe for clinical application.
Resumo:
The important task to observe the global coverage of middle atmospheric trace gases like water vapor or ozone usually is accomplished by satellites. Climate and atmospheric studies rely upon the knowledge of trace gas distributions throughout the stratosphere and mesosphere. Many of these gases are currently measured from satellites, but it is not clear whether this capability will be maintained in the future. This could lead to a significant knowledge gap of the state of the atmosphere. We explore the possibilities of mapping middle atmospheric water vapor in the Northern Hemisphere by using Lagrangian trajectory calculations and water vapor profile data from a small network of five ground-based microwave radiometers. Four of them are operated within the frame of NDACC (Network for the Detection of Atmospheric Composition Change). Keeping in mind that the instruments are based on different hardware and calibration setups, a height-dependent bias of the retrieved water vapor profiles has to be expected among the microwave radiometers. In order to correct and harmonize the different data sets, the Microwave Limb Sounder (MLS) on the Aura satellite is used to serve as a kind of traveling standard. A domain-averaging TM (trajectory mapping) method is applied which simplifies the subsequent validation of the quality of the trajectory-mapped water vapor distribution towards direct satellite observations. Trajectories are calculated forwards and backwards in time for up to 10 days using 6 hourly meteorological wind analysis fields. Overall, a total of four case studies of trajectory mapping in different meteorological regimes are discussed. One of the case studies takes place during a major sudden stratospheric warming (SSW) accompanied by the polar vortex breakdown; a second takes place after the reformation of stable circulation system. TM cases close to the fall equinox and June solstice event from the year 2012 complete the study, showing the high potential of a network of ground-based remote sensing instruments to synthesize hemispheric maps of water vapor.
Resumo:
BACKGROUND In contrast to objective structured clinical examinations (OSCEs), mini-clinical evaluation exercises (mini-CEXs) take place at the clinical workplace. As both mini-CEXs and OSCEs assess clinical skills, but within different contexts, this study aims at analyzing to which degree students' mini-CEX scores can be predicted by their recent OSCE scores and/or context characteristics. METHODS Medical students participated in an end of Year 3 OSCE and in 11 mini-CEXs during 5 different clerkships of Year 4. The students' mean scores of 9 clinical skills OSCE stations and mean 'overall' and 'domain' mini-CEX scores, averaged over all mini-CEXs of each student were computed. Linear regression analyses including random effects were used to predict mini-CEX scores by OSCE performance and characteristics of clinics, trainers, students and assessments. RESULTS A total of 512 trainers in 45 clinics provided 1783 mini-CEX ratings for 165 students; OSCE results were available for 144 students (87 %). Most influential for the prediction of 'overall' mini-CEX scores was the trainers' clinical position with a regression coefficient of 0.55 (95 %-CI: 0.26-0.84; p < .001) for residents compared to heads of department. Highly complex tasks and assessments taking place in large clinics significantly enhanced 'overall' mini-CEX scores, too. In contrast, high OSCE performance did not significantly increase 'overall' mini-CEX scores. CONCLUSION In our study, Mini-CEX scores depended rather on context characteristics than on students' clinical skills as demonstrated in an OSCE. Ways are discussed which focus on either to enhance the scores' validity or to use narrative comments only.
Resumo:
High-energy e(-) and pi(-) were measured by the multichannel plate (MCP) detector at the PiM1 beam line of the High Intensity Proton Accelerator Facilities located at the Paul Scherrer Institute, Villigen, Switzerland. The measurements provide the absolute detection efficiencies for these particles: 5.8% +/- 0.5% for electrons in the beam momenta range 17.5-300 MeV/c and 6.0% +/- 1.3% for pions in the beam momenta range 172-345 MeV/c. The pulse height distribution determined from the measurements is close to an exponential function with negative exponent, indicating that the particles penetrated the MCP material before producing the signal somewhere inside the channel. Low charge extraction and nominal gains of the MCP detector observed in this study are consistent with the proposed mechanism of the signal formation by penetrating radiation. A very similar MCP ion detector will be used in the Neutral Ion Mass (NIM) spectrometer designed for the JUICE mission of European Space Agency (ESA) to the Jupiter system, to perform measurements of the chemical composition of the Galilean moon exospheres. The detection efficiency for penetrating radiation determined in the present studies is important for the optimisation of the radiation shielding of the NIM detector against the high-rate and high-energy electrons trapped in Jupiter's magnetic field. Furthermore, the current studies indicate that MCP detectors can be useful to measure high-energy particle beams at high temporal resolution. (C) 2015 AIP Publishing LLC.