218 resultados para Malpositioned implant


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 39-year-old female with elevated serum cobalt levels from her bilateral hip prostheses presented with a 3-week history of blurred vision in her left eye. Optical coherence tomography revealed patchy degeneration of the photoreceptor-retinal pigment epithelium (RPE) complex. The lesions were hypofluorescent on indocyanine green angiography. We postulate that this is a case of implant-related chorio-retinal cobalt toxicity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this systematic review was to assess the optimal number of implants for removable reconstructions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To assess the 5-year survival rates and incidences of complications of cemented and screw-retained implant reconstructions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Unfavorable immediate or delayed results after transcatheter aortic valve implantation (TAVI) may be a consequence of bioprosthesis malfunctioning, malpositioning, embolization, or degeneration. Deployment of a second valve within the first one implanted (TAVI-in-TAV) may be a potentially helpful therapeutic strategy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: This article describes reconstruction of the severely atrophic mandible using calvarial bone grafts for implant-supported prosthetic oral rehabilitation. The study aim was to evaluate the efficacy of the treatment by determining implant survival and complication rates, and the extent of the postoperative graft resorption. STUDY DESIGN: Ten patients who underwent the treatment were followed clinically and radiologically using panoramic radiographs and CT scans during a mean postoperative period of 30 months. RESULTS: Good bone healing was observable 6 months postoperatively. The height reduction measured on panoramic radiographs was insignificant (mean 0.68 mm). Only minor complications occurred. Implant survival was 95%. Prosthodontic treatment was successfully performed in all cases, resulting in an improvement of oral function. Histological analysis of 1 bone biopsy showed minimal resorptive changes in otherwise very dense bone. CONCLUSION: Augmentation using calvarial grafts is a promising treatment alternative for the severely atrophic mandible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Microrough titanium (Ti) surfaces of dental implants have demonstrated more rapid and greater bone apposition when compared with machined Ti surfaces. However, further enhancement of osteoblastic activity and bone apposition by bio-functionalizing the implant surface with a monomolecular adsorbed layer of a co-polymer - i.e., poly(L-lysine)-graft-poly(ethylene glycol) (PLL-g-PEG) and its derivatives (PLL-g-PEG/PEG-peptide) - has never been investigated. The aim of the present study was to examine early bone apposition to a modified sandblasted and acid-etched (SLA) surface coated with an Arg-Gly-Asp (RGD)-peptide-modified polymer (PLL-g-PEG/PEG-RGD) in the maxillae of miniature pigs, and to compare it with the standard SLA surface. Test and control implants had the same microrough topography (SLA), but differed in their surface chemistry (polymer coatings). The following surfaces were examined histomorphometrically: (i) control - SLA without coating; (ii) (PLL-g-PEG); (iii) (PLL-g-PEG/PEG-RDG) (RDG, Arg-Asp-Gly); and (iv) (PLL-g-PEG/PEG-RGD). At 2 weeks, RGD-coated implants demonstrated significantly higher percentages of bone-to-implant contact as compared with controls (61.68% vs. 43.62%; P < 0.001). It can be concluded that the (PLL-g-PEG/PEG-RGD) coatings may promote enhanced bone apposition during the early stages of bone regeneration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: (I) To compare the oral microflora at implant and tooth sites in subjects participating in a periodontal recall program, (II) to test whether the microflora at implant and tooth sites differ as an effect of gingival bleeding (bleeding on probing (BOP)), or pocket probing depth (PPD), and (III) to test whether smoking and gender had an impact on the microflora. MATERIAL AND METHODS: Data were collected from 127 implants and all teeth in 56 subjects. Microbiological data were identified by the DNA-DNA checkerboard hybridization. RESULTS: PPD> or =4 mm were found in 16.9% of tooth, and at 26.6% of implant sites (P<0.01). Tooth sites with PPD> or =4 mm had a 3.1-fold higher bacterial load than implant sites (mean difference: 66%, 95% confidence interval (CI): 40.7-91.3, P<0.001). No differences were found for the red, orange, green, and yellow complexes. A higher total bacterial load was found at implant sites with PPD> or =4 mm (mean difference 35.7 x 10(5), 95% CI: 5.2 (10(5)) to 66.1 (10(5)), P<0.02 with equal variance not assumed). At implant sites, BOP had no impact on bacterial load but influenced the load at tooth sites (P<0.01). CONCLUSION: BOP, and smoking had no impact on bacteria at implant sites but influenced the bacterial load at tooth sites. Tooth sites harbored more bacteria than implant sites with comparable PPD. The 4 mm PPD cutoff level influenced the distribution and amounts of bacterial loads. The subject factor is explanatory to bacterial load at both tooth and implant sites.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Studies have shown similarities in the microflora between titanium implants or tooth sites when samples are taken by gingival crevicular fluid (GCF) sampling methods. The purpose of the present study was to study the microflora from curette and GCF samples using the checkerboard DNA-DNA hybridization method to assess the microflora of patients who had at least one oral osseo-integrated implant and who were otherwise dentate. Plaque samples were taken from tooth/implant surfaces and from sulcular gingival surfaces with curettes, and from gingival fluid using filter papers. A total of 28 subjects (11 females) were enrolled in the study. The mean age of the subjects was 64.1 years (SD+/-4.7). On average, the implants studied had been in function for 3.7 years (SD+/-2.9). The proportion of Streptococcus oralis (P<0.02) and Fusobacterium periodonticum (P<0.02) was significantly higher at tooth sites (curette samples). The GCF samples yielded higher proportions for 28/40 species studies (P-values varying between 0.05 and 0.001). The proportions of Tannerella forsythia (T. forsythensis), and Treponema denticola were both higher in GCF samples (P<0.02 and P<0.05, respectively) than in curette samples (implant sites). The microbial composition in gingival fluid from samples taken at implant sites differed partly from that of curette samples taken from implant surfaces or from sulcular soft tissues, providing higher counts for most bacteria studied at implant surfaces, but with the exception of Porphyromonas gingivalis. A combination of GCF and curette sampling methods might be the most representative sample method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An implant-abutment interface at the alveolar bone crest is associated with sustained peri-implant inflammation; however, whether magnitude of inflammation is proportionally dependent upon interface position remains unknown. This study compared the distribution and density of inflammatory cells surrounding implants with a supracrestal, crestal, or subcrestal implant-abutment interface. All implants developed a similar pattern of peri-implant inflammation: neutrophilic polymorphonuclear leukocytes (neutrophils) maximally accumulated at or immediately coronal to the interface. However, peri-implant neutrophil accrual increased progressively as the implant-abutment interface depth increased, i.e., subcrestal interfaces promoted a significantly greater maximum density of neutrophils than did supracrestal interfaces (10,512 +/- 691 vs. 2398 +/- 1077 neutrophils/mm(2)). Moreover, inflammatory cell accumulation below the original bone crest was significantly correlated with bone loss. Thus, the implant-abutment interface dictates the intensity and location of peri-implant inflammatory cell accumulation, a potential contributing component in the extent of implant-associated alveolar bone loss.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To monitor resonance frequency analysis (RFA) in relation to the jawbone characteristics and during the early phases of healing and incorporation of Straumann dental implants with an SLA surface. MATERIAL AND METHODS: 17 Straumann 4.1 mm implants (10 mm) and 7 Straumann 4.8 mm implants (10 mm) were installed and ISQ determined at baseline and after 1, 2, 3, 4, 5, 6, 8 and 12 weeks. Central bone cores were analyzed from the 4.1 mm implants using micro CT for bone volume density (BVD) and bone trabecular connectivity (BTC). RESULTS: Pocket probing depths ranged from 2-4 mm and bleeding on probing from 5-20%. At baseline, BVD varied between 24% and 65% and BTC between 4.9 and 25.4 for the 4.1 mm implants. Baseline ISQ varied between 55 and 74 with a mean of 61.4. No significant correlations were found between BVD or BTC and ISQ Values. For the 4.8 mm diameter implants baseline ISQ values ranged from 57-70 with a mean of 63.3. Over the healing period ISQ values increased at 1 week and decreased after 2-3 weeks. After 4 weeks ISQ values, again increased slightly, no significant differences were noted over time. One implant (4.1 mm) lost stability at 3 weeks. Its ISQ value had dropped from 68 to 45. However the latter value was determined after the clinical diagnosis of instability. CONCLUSION: ISQ values of 57-70 represented homeostasis and implant stability. However no predictive value for loosing implant stability can be attributed to RFA since the decrease occurred after the fact.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This third part of a series of publications from the Swiss task force "Smoking--Intervention in the private dental office" on the topic "tobacco use and dental medicine" describes the clinical and radiographic changes of the periodontium within smokers as well as the consequences of tobacco use on periodontal and implant therapy. With increased use of tobacco, patients show higher periodontal probing depths, increased clinical attachment loss, more alveolar bone resorption, a higher prevalence of gingival recessions, and a higher risk for tooth loss. In contrast to this, with smokers, the clinical characteristics of gingival inflammation or bleeding on periodontal probing are less established. Smokers show less positive results after conventional, surgical and regenerative periodontal therapy. The benefits of mucogingval surgery are reduced and less successful in smokers. Moreover, smoking impairs the osseointegration of oral implants and is at least partly responsible for a majority of biological complications in implant dentistry, such as periimplantitis. Based on the present understanding of periodontal diseases, the clinical findings, and the specific therapeutic outcomes with smokers, it appears to be reasonable, next to the current classification of periodontal diseases, to use the term "smokers periodontitis".

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this paper was to review the clinical literature on the Resonance frequency analysis (RFA) and Periotest techniques in order to assess the validity and prognostic value of each technique to detect implants at risk for failure. Material and methods: A search was made using the PubMed database to find clinical studies using the RFA and/or Periotest techniques. Results: A limited number of clinical reports were found. No randomized-controlled clinical trials or prospective cohort studies could be found for validity testing of the techniques. Consequently, only a narrative review was prepared to cover general aspects of the techniques, factors influencing measurements and the clinical relevance of the techniques. Conclusions: Factors such as bone density, upper or lower jaw, abutment length and supracrestal implant length seem to influence both RFA and Periotest measurements. Data suggest that high RFA and low Periotest values indicate successfully integrated implants and that low/decreasing RFA and high/increasing Periotest values may be signs of ongoing disintegration and/or marginal bone loss. However, single readings using any of the techniques are of limited clinical value. The prognostic value of the RFA and Periotest techniques in predicting loss of implant stability has yet to be established in prospective clinical studies. To cite this article: Aparicio C, Lang N P, Rangert B. Validity and clinical significance of biomechanical testing of implant/bone interface. Clin. Oral Imp. Res., 17 (Suppl. 2), 2006; 2-7.