54 resultados para Lower level relaxation
Resumo:
Aims: The reported rate of stent thrombosis (ST) after drug-eluting stent (DES) implantation varies among registries. To investigate differences in baseline characteristics and clinical outcome in European and Japanese all-comers registries, we performed a pooled analysis of patient-level data. Methods and results: The j-Cypher registry (JC) is a multicentre observational study conducted in Japan, including 12,824 patients undergoing SES implantation. From the Bern-Rotterdam registry (BR) enrolled at two academic hospitals in Switzerland and the Netherlands, 3,823 patients with SES were included in the current analysis. Patients in BR were younger, more frequently smokers and presented more frequently with ST-elevation myocardial infarction (MI). Conversely, JC patients more frequently had diabetes and hypertension. At five years, the definite ST rate was significantly lower in JC than BR (JC 1.6% vs. BR 3.3%, p<0.001), while the unadjusted mortality tended to be lower in BR than in JC (BR 13.2% vs. JC 14.4%, log-rank p=0.052). After adjustment, the j-Cypher registry was associated with a significantly lower risk of all-cause mortality (HR 0.56, 95% CI: 0.49-0.64) as well as definite stent thrombosis (HR 0.46, 95% CI: 0.35-0.61). Conclusions: The baseline characteristics of the two large registries were different. After statistical adjustment, JC was associated with lower mortality and ST.
Resumo:
It has long been surmised that income inequality within a society negatively affects public health. However, more recent studies suggest there is no association, especially when analyzing small areas. This study aimed to evaluate the effect of income inequality on mortality in Switzerland using the Gini index on municipality level. The study population included all individuals >30 years at the 2000 Swiss census (N = 4,689,545) living in 2,740 municipalities with 35.5 million person-years of follow-up and 456,211 deaths over follow-up. Cox proportional hazard regression models were adjusted for age, gender, marital status, nationality, urbanization, and language region. Results were reported as hazard ratios (HR) with 95 % confidence intervals. The mean Gini index across all municipalities was 0.377 (standard deviation 0.062, range 0.202-0.785). Larger cities, high-income municipalities and tourist areas had higher Gini indices. Higher income inequality was consistently associated with lower mortality risk, except for death from external causes. Adjusting for sex, marital status, nationality, urbanization and language region only slightly attenuated effects. In fully adjusted models, hazards of all-cause mortality by increasing Gini index quintile were HR = 0.99 (0.98-1.00), HR = 0.98 (0.97-0.99), HR = 0.95 (0.94-0.96), HR = 0.91 (0.90-0.92) compared to the lowest quintile. The relationship of income inequality with mortality in Switzerland is contradictory to what has been found in other developed high-income countries. Our results challenge current beliefs about the effect of income inequality on mortality on small area level. Further investigation is required to expose the underlying relationship between income inequality and population health.
Resumo:
QUESTIONS UNDER STUDY: Patient characteristics and risk factors for death of Swiss trauma patients in the Trauma Audit and Research Network (TARN). METHODS: Descriptive analysis of trauma patients (≥16 years) admitted to a level I trauma centre in Switzerland (September 1, 2009 to August 31, 2010) and entered into TARN. Multivariable logistic regression analysis was used to identify predictors of 30-day mortality. RESULTS: Of 458 patients 71% were male. The median age was 50.5 years (inter-quartile range [IQR] 32.2-67.7), median Injury Severity Score (ISS) was 14 (IQR 9-20) and median Glasgow Coma Score (GCS) was 15 (IQR 14-15). The ISS was >15 for 47%, and 14% had an ISS >25. A total of 17 patients (3.7%) died within 30 days of trauma. All deaths were in patients with ISS >15. Most injuries were due to falls <2 m (35%) or road traffic accidents (29%). Injuries to the head (39%) were followed by injuries to the lower limbs (33%), spine (28%) and chest (27%). The time of admission peaked between 12:00 and 22:00, with a second peak between 00:00 and 02:00. A total of 64% of patients were admitted directly to our trauma centre. The median time to CT was 30 min (IQR 18-54 min). Using multivariable regression analysis, the predictors of mortality were older age, higher ISS and lower GCS. CONCLUSIONS: Characteristics of Swiss trauma patients derived from TARN were described for the first time, providing a detailed overview of the institutional trauma population. Based on these results, patient management and hospital resources (e.g. triage of patients, time to CT, staffing during night shifts) could be evaluated as a further step.
Resumo:
OBJECTIVES In Europe and elsewhere, health inequalities among HIV-positive individuals are of concern. We investigated late HIV diagnosis and late initiation of combination antiretroviral therapy (cART) by educational level, a proxy of socioeconomic position. DESIGN AND METHODS We used data from nine HIV cohorts within COHERE in Austria, France, Greece, Italy, Spain and Switzerland, collecting data on level of education in categories of the UNESCO/International Standard Classification of Education standard classification: non-completed basic, basic, secondary and tertiary education. We included individuals diagnosed with HIV between 1996 and 2011, aged at least 16 years, with known educational level and at least one CD4 cell count within 6 months of HIV diagnosis. We examined trends by education level in presentation with advanced HIV disease (AHD) (CD4 <200 cells/μl or AIDS within 6 months) using logistic regression, and distribution of CD4 cell count at cART initiation overall and among presenters without AHD using median regression. RESULTS Among 15 414 individuals, 52, 45,37, and 31% with uncompleted basic, basic, secondary and tertiary education, respectively, presented with AHD (P trend <0.001). Compared to patients with tertiary education, adjusted odds ratios of AHD were 1.72 (95% confidence interval 1.48-2.00) for uncompleted basic, 1.39 (1.24-1.56) for basic and 1.20 (1.08-1.34) for secondary education (P < 0.001). In unadjusted and adjusted analyses, median CD4 cell count at cART initiation was lower with poorer educational level. CONCLUSIONS Socioeconomic inequalities in delayed HIV diagnosis and initiation of cART are present in European countries with universal healthcare systems and individuals with lower educational level do not equally benefit from timely cART initiation.
Resumo:
The S0 → S1 vibronic spectrum and S1 state nonradiative relaxation of jet-cooled keto-amino 5-fluorocytosine (5FCyt) are investigated by two-color resonant two-photon ionization spectroscopy at 0.3 and 0.05 cm–1 resolution. The 000 rotational band contour is polarized in-plane, implying that the electronic transition is 1ππ*. The electronic transition dipole moment orientation and the changes of rotational constants agree closely with the SCS-CC2 calculated values for the 1ππ* (S1) transition of 5FCyt. The spectral region from 0 to 300 cm–1 is dominated by overtone and combination bands of the out-of-plane ν1′ (boat), ν2′ (butterfly), and ν3′ (HN–C6H twist) vibrations, implying that the pyrimidinone frame is distorted out-of-plane by the 1ππ* excitation, in agreement with SCS-CC2 calculations. The number of vibronic bands rises strongly around +350 cm–1; this is attributed to the 1ππ* state barrier to planarity that corresponds to the central maximum of the double-minimum out-of-plane vibrational potentials along the ν1′, ν2′, and ν3′ coordinates, which gives rise to a high density of vibronic excitations. At +1200 cm–1, rapid nonradiative relaxation (knr ≥ 1012 s–1) sets in, which we interpret as the height of the 1ππ* state barrier in front of the lowest S1/S0 conical intersection. This barrier in 5FCyt is 3 times higher than that in cytosine. The lifetimes of the ν′ = 0, 2ν1′, 2ν2′, 2ν1′ + 2ν2′, 4ν2′, and 2ν1′ + 4ν2′ levels are determined from Lorentzian widths fitted to the rotational band contours and are τ ≥ 75 ps for ν′ = 0, decreasing to τ ≥ 55 ps at the 2ν1′ + 4ν2′ level at +234 cm–1. These gas-phase lifetimes are twice those of S1 state cytosine and 10–100 times those of the other canonical nucleobases in the gas phase. On the other hand, the 5FCyt gas-phase lifetime is close to the 73 ps lifetime in room-temperature solvents. This lack of dependence on temperature and on the surrounding medium implies that the 5FCyt nonradiative relaxation from its S1 (1ππ*) state is essentially controlled by the same ∼1200 cm–1 barrier and conical intersection both in the gas phase and in solution.
Resumo:
The achievement rate of recommended low-density lipoprotein cholesterol (LDL-C) targets of < 1.8 mmol/l for secondary prevention in very high risk patients is difficult. Observational studies reported that loss of function mutation of the PCS9 was associated with LDL-C decrease level and reduction of cardiovascular events. Monoclonal antibodies to PCSK9 (REGN727 and AMG 145, PSCK9 inhibitors) have been tested in clinical studies of phase I and II and showed LDL-C level reduction of 60-70% compared to placebo. This approach appears safe and well-tolerated. The PCSK9 inhibitors are now tested in large phase III clinical studies to assess the long-term safety and efficacy of this new promising approach.
Resumo:
Visual perception is not identical in the upper and lower visual hemifields. The mechanisms behind this difference can be found at the retinal, cortical, or higher attentional level. In this study, a new visual test battery, that involves real-time comparisons of complex visual stimuli, such as shape of objects, and speed of moving dot patterns, in the upper and lower visual hemifields, is presented. This study represents, to our knowledge, the first to implement such a visual test battery in an immersive environment composed of a hemisphere, in order to present visual stimuli in precise regions of the visual field. Ten healthy volunteers were tested in this pilot study. The results showed a higher accuracy in the image matching when the visual test was performed in the lower visual hemifield.
Resumo:
OBJECTIVES The purpose of this study was to compare the 2-year safety and effectiveness of new- versus early-generation drug-eluting stents (DES) according to the severity of coronary artery disease (CAD) as assessed by the SYNTAX (Synergy between Percutaneous Coronary Intervention with Taxus and Cardiac Surgery) score. BACKGROUND New-generation DES are considered the standard-of-care in patients with CAD undergoing percutaneous coronary intervention. However, there are few data investigating the effects of new- over early-generation DES according to the anatomic complexity of CAD. METHODS Patient-level data from 4 contemporary, all-comers trials were pooled. The primary device-oriented clinical endpoint was the composite of cardiac death, myocardial infarction, or ischemia-driven target-lesion revascularization (TLR). The principal effectiveness and safety endpoints were TLR and definite stent thrombosis (ST), respectively. Adjusted hazard ratios (HRs) with 95% confidence intervals (CIs) were calculated at 2 years for overall comparisons, as well as stratified for patients with lower (SYNTAX score ≤11) and higher complexity (SYNTAX score >11). RESULTS A total of 6,081 patients were included in the study. New-generation DES (n = 4,554) compared with early-generation DES (n = 1,527) reduced the primary endpoint (HR: 0.75 [95% CI: 0.63 to 0.89]; p = 0.001) without interaction (p = 0.219) between patients with lower (HR: 0.86 [95% CI: 0.64 to 1.16]; p = 0.322) versus higher CAD complexity (HR: 0.68 [95% CI: 0.54 to 0.85]; p = 0.001). In patients with SYNTAX score >11, new-generation DES significantly reduced TLR (HR: 0.36 [95% CI: 0.26 to 0.51]; p < 0.001) and definite ST (HR: 0.28 [95% CI: 0.15 to 0.55]; p < 0.001) to a greater extent than in the low-complexity group (TLR pint = 0.059; ST pint = 0.013). New-generation DES decreased the risk of cardiac mortality in patients with SYNTAX score >11 (HR: 0.45 [95% CI: 0.27 to 0.76]; p = 0.003) but not in patients with SYNTAX score ≤11 (pint = 0.042). CONCLUSIONS New-generation DES improve clinical outcomes compared with early-generation DES, with a greater safety and effectiveness in patients with SYNTAX score >11.
Resumo:
BACKGROUND The safety and efficacy of new-generation drug-eluting stents (DES) in women with multiple atherothrombotic risk (ATR) factors is unclear. METHODS AND RESULTS We pooled patient-level data for women enrolled in 26 randomized trials. Study population was categorized based on the presence or absence of high ATR, which was defined as having history of diabetes mellitus, prior percutaneous or surgical coronary revascularization, or prior myocardial infarction. The primary end point was major adverse cardiovascular events defined as a composite of all-cause mortality, myocardial infarction, or target lesion revascularization at 3 years of follow-up. Out of 10 449 women included in the pooled database, 5333 (51%) were at high ATR. Compared with women not at high ATR, those at high ATR had significantly higher risk of major adverse cardiovascular events (15.8% versus 10.6%; adjusted hazard ratio: 1.53; 95% confidence interval: 1.34-1.75; P=0.006) and all-cause mortality. In high-ATR risk women, the use of new-generation DES was associated with significantly lower risk of 3-year major adverse cardiovascular events (adjusted hazard ratio: 0.69; 95% confidence interval: 0.52-0.92) compared with early-generation DES. The benefit of new-generation DES on major adverse cardiovascular events was uniform between high-ATR and non-high-ATR women, without evidence of interaction (Pinteraction=0.14). At landmark analysis, in high-ATR women, stent thrombosis rates were comparable between DES generations in the first year, whereas between 1 and 3 years, stent thrombosis risk was lower with new-generation devices. CONCLUSIONS Use of new-generation DES even in women at high ATR is associated with a benefit consistent over 3 years of follow-up and a substantial improvement in very-late thrombotic safety.