67 resultados para Loss Determination in Microsphere Resonators
Resumo:
OBJECTIVE To compare speech understanding of the BAHA BP110 and BAHA Intenso sound processors. STUDY DESIGN Prospective experimental study. SETTING Tertiary referral center. PATIENTS Twenty experienced user of osseointegrated auditory implants with conductive or mixed hearing loss. INTERVENTIONS In a first session, half of the participants were fitted with an Intenso, the other half with a BP110. After 1 month of use, aided speech understanding in quiet and in noise was measured, and the other test processor was fitted. One month later, speech understanding with the second sound processor was assessed. MAIN OUTCOME MEASURES Speech understanding in quiet and in noise, with noise arriving either from the front, the rear, or the side of the user with the osseointegrated bone conductor. RESULTS Significant improvements were found for both processors for speech understanding in quiet (+9.6 to +34.8 percent points; p = 0.02 to 0.001) and in noise (+6.2 to +13.8 dB, p < 0.001). No significant differences were found between the 2 devices for speech in quiet. For noise from the rear, subjects were able to understand speech at signal-to-noise ratios which were lower (less favorable) by -5.1 dB (p < 0.001) when compared with the Intenso. CONCLUSION Speech understanding is substantially improved by both devices, with no significant differences between the sound processors in quiet. In noise, speech understanding is significantly better with the BP110 when compared to the Intenso for noise from the rear.
Resumo:
The time variable Earth’s gravity field provides the information about mass transport within the system Earth, i.e., the relationship of mass transport between atmosphere, oceans, and land hydrology. We recover the low-degree parameters of the time variable gravity field using microwave observations from GPS and GLONASS satellites and from SLR data to five geodetic satellites, namely LAGEOS-1/2, Starlette, Stella, and AJISAI. GPS satellites are particularly sensitive to specific coefficients of the Earth's gravity field, because of the deep 2:1 orbital resonance with Earth rotation (two revolutions of the GPS satellites per sidereal day). The resonant coefficients cause, among other, a “secular” drift (actually periodic variations of very long periods) of the semi-major axes of up to 5.3 m/day of GPS satellites. We processed 10 years of GPS and GLONASS data using the standard orbit models from the Center of Orbit Determination in Europe (CODE) with a simultaneous estimation of the Earth gravity field coefficients and other parameters, e.g., satellite orbit parameters, station coordinates, Earth rotation parameters, troposphere delays, etc. The weekly GNSS gravity solutions up to degree and order 4/4 are compared to the weekly SLR gravity field solutions. The SLR-derived geopotential coefficients are compared to monthly GRACE and CHAMP results.
Resumo:
Bone Anchored Hearing Implants (BAHI) are routinely used in patients with conductive or mixed hearing loss, e.g. if conventional air conduction hearing aids cannot be used. New sound processors and new fitting software now allow the adjustment of parameters such as loudness compression ratios or maximum power output separately. Today it is unclear, how the choice of these parameters influences aided speech understanding in BAHI users. In this prospective experimental study, the effect of varying the compression ratio and lowering the maximum power output in a BAHI were investigated. Twelve experienced adult subjects with a mixed hearing loss participated in this study. Four different compression ratios (1.0; 1.3; 1.6; 2.0) were tested along with two different maximum power output settings, resulting in a total of eight different programs. Each participant tested each program during two weeks. A blinded Latin square design was used to minimize bias. For each of the eight programs, speech understanding in quiet and in noise was assessed. For speech in quiet, the Freiburg number test and the Freiburg monosyllabic word test at 50, 65, and 80 dB SPL were used. For speech in noise, the Oldenburg sentence test was administered. Speech understanding in quiet and in noise was improved significantly in the aided condition in any program, when compared to the unaided condition. However, no significant differences were found between any of the eight programs. In contrast, on a subjective level there was a significant preference for medium compression ratios of 1.3 to 1.6 and higher maximum power output.
Resumo:
A reliable and robust routing service for Flying Ad-Hoc Networks (FANETs) must be able to adapt to topology changes. User experience on watching live video sequences must also be satisfactory even in scenarios with buffer overflow and high packet loss ratio. In this paper, we introduce a Cross-layer Link quality and Geographical-aware beaconless opportunistic routing protocol (XLinGO). It enhances the transmission of simultaneous multiple video flows over FANETs by creating and keeping reliable persistent multi-hop routes. XLinGO considers a set of cross-layer and human-related information for routing decisions, as performance metrics and Quality of Experience (QoE). Performance evaluation shows that XLinGO achieves multimedia dissemination with QoE support and robustness in a multi-hop, multi-flow, and mobile network environments.
Resumo:
This paper presents a novel extraction device for water and noble gases from speleothem samples for noble gas paleotemperature determination. The “combined vacuum crushing and sieving (CVCS) system” was designed to reduce the atmospheric noble gas contents from air inclusions in speleothem samples by up to 2 orders of magnitude without adsorbing atmospheric noble gases onto the freshly produced grain surfaces, a process that had often hampered noble gas temperature (NGT) determination in the past. We also present the results from first performance tests of the CVCS system processing stalagmite samples grown at a known temperature. This temperature is reliably reproduced by the NGTs derived from Ar, Kr, and Xe extracted from the samples. The CVCS system is, therefore, suitable for routine determinations of accurate NGTs. In combination with stalagmite dating, these NGTs will allow reconstructing past regional temperature evolutions, and also support the interpretation of the often complex stable isotope records preserved in the stalagmites' calcite.
Resumo:
BACKGROUND
Renal impairment (RI) is associated with impaired prognosis in patients with coronary artery disease. Clinical and angiographic outcomes of patients undergoing percutaneous coronary intervention (PCI) with the use of drug-eluting stents (DES) in this patient population are not well established.
METHODS
We pooled individual data for 5,011 patients from 3 trials with the exclusive and unrestricted use of DES (SIRTAX - N = 1,012, LEADERS - N = 1,707, RESOLUTE AC - N = 2,292). Angiographic follow-up was available for 1,544 lesions. Outcomes through 2 years were stratified according to glomerular filtration rate (normal renal function: GFR≥90 ml/min; mild RI: 90
Resumo:
The user experience on watching live video se- quences transmitted over a Flying Ad-Hoc Networks (FANETs) must be considered to drop packets in overloaded queues, in scenarios with high buffer overflow and packet loss rate. In this paper, we introduce a context-aware adaptation mechanism to manage overloaded buffers. More specifically, we propose a utility function to compute the dropping probability of each packet in overloaded queues based on video context information, such as frame importance, packet deadline, and sensing relevance. In this way, the proposed mechanism drops the packet that adds the minimum video distortion. Simulation evaluation shows that the proposed adaptation mechanism provides real-time multimedia dissemination with QoE support in a multi-hop, multi-flow, and mobile network environments.
Resumo:
Objective: To investigate objective and subjective effects of an adjunctive contralateral routing of signal (CROS) device at the untreated ear in patients with a unilateral cochlear implant (CI). Design: Prospective study of 10 adult experienced unilateral CI users with bilateral severe-to-profound hearing loss. Speech in noise reception (SNR) and sound localization were measured with and without the additional CROS device. SNR was measured by applying speech signals at the untreated/CROS side while noise signals came from the front (S90N0). For S0N90, signal sources were switched. Sound localization was measured in a 12-loudspeaker full circle setup. To evaluate the subjective benefit, patients tried the device for 2 weeks at home, then filled out the abbreviated Speech, Spatial and Qualities of Hearing Scale as well as the Bern benefit in single-sided deafness questionnaires. Results: In the setting S90N0, all patients showed a highly significant SNR improvement when wearing the additional CROS device (mean 6.4 dB, p < 0.001). In the unfavorable setting S0N90, only a minor deterioration of speech understanding was noted (mean -0.66 dB, p = 0.54). Sound localization did not improve substantially with CROS. In the two questionnaires, 12 of 14 items showed an improvement in mean values, but none of them was statistically significant. Conclusion: Patients with unilateral CI benefit from a contralateral CROS device, particularly in a noisy environment, when speech comes from the CROS ear side. © 2014 S. Karger AG, Basel.
Resumo:
We process 20 years of SLR observations to GPS and GLONASS satellites using the reprocessed 3-day and 1-day microwave orbits provided by the Center for Orbit Determination in Europe (CODE) for the period 1994-2013. We study the dependency of the SLR residuals on the type, size, and a number of corner cubes in satellite laser reflector arrays (LRA). We show that the mean SLR residuals and the RMS of residuals depend on the coating of LRA and the block or type of GNSS satellites. The SLR mean residuals are also a function of the equipment used at SLR stations including detector types and detecting modes.
Resumo:
The International GNSS Service (IGS) issues four sets of so-called ultra-rapid products per day, which are based on the contributions of the IGS Analysis Centers. The traditional (“old”) ultra-rapid orbit and earth rotation parameters (ERP) solution of the Center for Orbit Determination in Europe (CODE) was based on the output of three consecutive 3-day long-arc rapid solutions. Information from the IERS Bulletin A was required to generate the predicted part of the old CODE ultra-rapid product. The current (“new”) product, activated in November 2013, is based on the output of exactly one multi-day solution. A priori information from the IERS Bulletin A is no longer required for generating and predicting the orbits and ERPs. This article discusses the transition from the old to the new CODE ultra-rapid orbit and ERP products and the associated improvement in reliability and performance. All solutions used in this article were generated with the development version of the Bernese GNSS Software. The package was slightly extended to meet the needs of the new CODE ultra-rapid generation.
Resumo:
Satellite laser ranging (SLR) to the satellites of the global navigation satellite systems (GNSS) provides substantial and valuable information about the accuracy and quality of GNSS orbits and allows for the SLR-GNSS co-location in space. In the framework of the NAVSTAR-SLR experiment two GPS satellites of Block-IIA were equipped with laser retroreflector arrays (LRAs), whereas all satellites of the GLONASS system are equipped with LRAs in an operational mode. We summarize the outcome of the NAVSTAR-SLR experiment by processing 20 years of SLR observations to GPS and 12 years of SLR observations to GLONASS satellites using the reprocessed microwave orbits provided by the center for orbit determination in Europe (CODE). The dependency of the SLR residuals on the size, shape, and number of corner cubes in LRAs is studied. We show that the mean SLR residuals and the RMS of residuals depend on the coating of the LRAs and the block or type of GNSS satellites. The SLR mean residuals are also a function of the equipment used at SLR stations including the single-photon and multi-photon detection modes. We also show that the SLR observations to GNSS satellites are important to validate GNSS orbits and to assess deficiencies in the solar radiation pressure models. We found that the satellite signature effect, which is defined as a spread of optical pulse signals due to reflection from multiple reflectors, causes the variations of mean SLR residuals of up to 15 mm between the observations at nadir angles of 0∘ and 14∘. in case of multi-photon SLR stations. For single-photon SLR stations this effect does not exceed 1 mm. When using the new empirical CODE orbit model (ECOM), the SLR mean residual falls into the range 0.1–1.8 mm for high-performing single-photon SLR stations observing GLONASS-M satellites with uncoated corner cubes. For best-performing multi-photon stations the mean SLR residuals are between −12.2 and −25.6 mm due to the satellite signature effect.
Resumo:
Agriculture is the back borne of the economy of Tanzania and its main objective is to ensure food security and eradication of rural poverty through the promotion of production systems, technologies and practices that are environmental sound (Tanzania National Environmental Policy, 1999). However, this has not been achieved due to rapid land degradation, which has consequently lead to massive soil loss, decline in crop yields, disruption of water resources and the destruction of the natural resources in general. This report highlights the extent to which agricultural related activities like agronomic and cultural practices such as use of fire for preparation of farms and cutting of trees to meet villagers’ needs have devastating effect on the quality of the environment. Besides these observed difficulties this paper argued that as the survival, well being and future of the Uluguru and Usambara people it is essential to provide continuous training to farmers, so that they know how best to continue farming and harvesting forest products on a sustainable basis without causing much harm to the environment. Most of all this paper recommends the introduction of Ngolo cultivation technology on steep slopes of Usambara and Uluguru mountains in order to enhance the conservation of the environment.
Resumo:
The Astronomical Institute of the University of Bern (AIUB) is conducting several search campaigns for space debris using optical sensors. The debris objects are discovered during systematic survey observations. In general, the result of a discovery consists in only a short observation arc, or tracklet, which is used to perform a first orbit determination in order to be able to observe t he object again in subsequent follow-up observations. The additional observations are used in the orbit improvement process to obtain accurate orbits to be included in a catalogue. In order to obtain the most accurate orbit within the time available it is necessary to optimize the follow-up observations strategy. In this paper an in‐depth study, using simulations and covariance analysis, is performed to identify the optimal sequence of follow-up observations to obtain the most accurate orbit propagation to be used for the space debris catalogue maintenance. The main factors that determine the accuracy of the results of an orbit determination/improvement process are: tracklet length, number of observations, type of orbit, astrometric error of the measurements, time interval between tracklets, and the relative position of the object along its orbit with respect to the observing station. The main aim of the covariance analysis is to optimize the follow-up strategy as a function of the object-observer geometry, the interval between follow-up observations and the shape of the orbit. This an alysis can be applied to every orbital regime but particular attention was dedicated to geostationary, Molniya, and geostationary transfer orbits. Finally the case with more than two follow-up observations and the influence of a second observing station are also analyzed.
Resumo:
CODE, the Center for Orbit Determination in Europe, is a joint venture of the following four institutions: Astronomical Institute, University of Bern (AIUB), Bern, Switzerland; Federal Office of Topography swisstopo, Wabern, Switzerland; Federal Agency of Cartography and Geodesy (BKG), Frankfurt a. M., Germany; Institut für Astronomische und Physikalische Geodäsie, Technische Universität München (IAPG, TUM), Munich, Germany. It acts as a global analysis center of the International GNSS Service (IGS). The operational computations are performed at AIUB using the latest development version of the Bernese GNSS Software. In this context an ultra-rapid solution series is generated considering GPS and GLONASS satellites. It is updated several times per day and contains 24 hours of observed and 24 hours of predicted orbit interval. More details are available in: Lutz, S., G. Beutler, S. Schaer, R. Dach, A. Jäggi; 2014: CODE's new ultra-rapid orbit and ERP products for the IGS. GPS Solutions. DOI 10.1007/s10291-014-0432-2
Resumo:
CODE, the Center for Orbit Determination in Europe, is a joint venture of the following four institutions: • Astronomical Institute, University of Bern (AIUB), Bern, Switzerland • Federal Office of Topography swisstopo, Wabern, Switzerland • Federal Agency of Cartography and Geodesy (BKG), Frankfurt a. M., Germany • Institut für Astronomische und Physikalische Geodäsie, Technische Universität München (IAPG, TUM), Munich, Germany It acts as a global analysis center of the International GNSS Service (IGS, Dow et al, 2009). The operational computations are performed at AIUB using the latest development version of the Bernese GNSS Software (Dach et al., 2015). In this context the contribution to the IGS repro02 effort is generated considering only the GPS satellites between 1994 and 2001 as well as the GPS and GLONASS satellites from 2002 to the end of 2013.