96 resultados para Greenhouse position


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: We report the results and complications associated with standardized intraoperative management designed for the prevention of hemodynamically relevant venous air embolism during surgery performed in the semisitting position. METHODS: A protocol for preoperative evaluation and intraoperative monitoring was developed and applied in 187 consecutive patients who underwent surgery in the semisitting position between 1999 and 2004. The protocol included preoperative transesophageal echocardiography examination (TEE), intraoperative TEE monitoring, catheterization of the right atrium and a combination of fluid input, positive end expiratory pressure, and standardized positioning aiming at a positive pressure in the transverse and sigmoid sinuses. Data were collected retrospectively from the charts and intraoperative anesthesiological protocols of the patients for the incidence of clinically relevant air embolism (i.e., TEE-diagnosed air embolism plus a decrease in end tidal CO2 or hemodynamic changes) and other complications related to the semisitting position. RESULTS: Three cases (1.6%) of relevant venous air embolism occurred in 187 patients. Only 1 case (0.5%) was hemodynamically relevant, with temporary arterial blood pressure decrease and heart rate increase. Pneumatocephalus leading to lethargy was a frequent postoperative finding, which resolved spontaneously in all except 1 patient with epileptic seizure and oculomotor nerve palsy attributable to space-occupying subdurally trapped air, which had to be treated surgically. There was no permanent morbidity or mortality related to the semisitting position. CONCLUSION: Fear of massive venous air embolism is one reason for dramatic decline in the use of the semisitting position in neurosurgical practice. We found that strict adherence to a standardized protocol using TEE monitoring before and during surgery; exclusion of patients with patent foramen ovale; and a combination of positive end expiratory pressure, fluid input, and a standardized position aiming a positive pressure in the transverse and sigmoid sinuses helped to greatly minimize this complication to a rate of 0.5% for hemodynamically relevant events.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Most estimates of diffusive flux (F) of methane (CH4) and carbon dioxide (CO2) from lakes are based on single-point flux chamber measurements or on piston velocity (k) modeled from wind speed and single-point measurements of surface water gas concentrations (C-aq). We analyzed spatial variability of F of CH4 and CO2, as well as C-aq and k in 22 European lakes during late summer. F and k were higher in the lake centers, leading to considerable bias when extrapolating single-point chamber measurements to whole-lake estimates. The ratio of our empirical k estimates to wind speed-modeled k was related to lake size and shape, suggesting a lake morphology effect on the relationship between wind speed and k. This indicates that the error inherent to established wind speed models can be reduced by determining k and C-aq at multiple sites on lakes to calibrate wind speed-modeled k to the local system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of pressure waves to confirm the correct position of the epidural needle has been described in several domestic species and proposed as a valid alternative to standard methods, namely, control radiographic exam and fluoroscopy. The object of this retrospective clinical study was to evaluate the sensitivity of the epidural pressure waves as a test to verify the correct needle placement in the epidural space in dogs, in order to determine whether this technique could be useful not only in the clinical setting but also when certain knowledge of needle's tip position is required, for instance when performing clinical research focusing on epidural anaesthesia. Of the 54 client-owned dogs undergoing elective surgeries and enrolled in this retrospective study, only 45% showed epidural pressure waves before and after epidural injection. Twenty-six percent of the animals showed epidural pressure waves only after the injection, whereas 29% of the dogs showed epidural pressure waves neither before nor after injection and were defined as false negatives. Our results show that the epidural pressure wave technique to verify epidural needle position lacks sensitivity, resulting in many false negatives. As a consequence, the applicability of this technique is limited to situations in which precise, exact knowledge of the needle's tip position is not mandatory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Digital analysis of the occlusal contacts can be performed with the T-scan device (T Scan III, TekScan, Boston, USA). However, the thickness of the interocclusal T-scan sheet (100 μm) may lead to a displacement of the mandible. Thus, the aim of this study was to investigate the impact of the T-scan sheet on the position of the mandibular condyles in maximum intercuspidation. Twenty dentate subjects with healthy jaw function were enrolled in the study. An ultrasonic axiography device was used to measure the position of the condyles. Ten 3D condyle positions in maximum intercuspidation of the teeth were recorded: first the reference position without the sheet, then 3 times without the sheet, 3 times with the sheet, and finally again 3 times without the sheet. There was a statistically significant difference (Wilcoxon matched pairs test) between the condyle positions with and without the interocclusally positioned T-scan sheet (P < 0.0005). The T-scan device lead to a displacement of the condyles of about 1 mm mainly in ventral direction (P = 0.005). Thus, occlusal analysis is not performed in physiological, maximum intercuspidation. This has to be considered when interpreting the measured contact points.