86 resultados para Full Restoration


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The aim of the present study was to report the radiographical prevalence of overhanging fillings in a group of Swiss Army recruits in 2006 and to relate the dimensions of the overhangs to clinical parameters. MATERIALS AND METHODS: A total of 626 Swiss Army recruits were examined for their periodontal conditions, prevalence of caries, and stomatological and functional aspects of the masticatory system and halitosis. In particular, the present report deals with the presence or the absence of fillings, the presence or the absence of overhangs and their relation to clinical and radiographic parameters. RESULTS: A total of 16,198 interdental sites were evaluated on bitewing radiographs. Of these sites, 15,516 (95.8%) were sound and 682 (4.2%) were filled. Amalgam restorations were found in 94.1% and resin composite fillings in 5.9% of the sites. Of these 682 sites, 96 (14.1%) yielded overhanging margins of various sizes. This low prevalence of fillings represents not only a substantial reduction when compared with a similar Swiss Army study (Lang et al, 1988), but also an improvement in the quality of dental care delivery to young Swiss males. Plaque Index and Gingival Index increased statistically significantly with the presence of fillings, when compared with healthy non-filled sites. Clinical parameters that were significantly associated with the presence of overhangs included clinical attachment loss. Moreover, between 1985 and 2006 the prevalence of fillings was significantly reduced from 20.0% to 4.2% of all surfaces. Furthermore, the marginal fit of the fillings improved from 33.0% with overhangs to 14.1%. CONCLUSIONS: A significant improvement was observed in the periodontal and dental conditions of young Swiss males that was shown to have taken place within the previous two decades. From 1985 to 2006, the prevalence of fillings was reduced fourfold and that of overhanging margins twofold, documenting an improvement in the quality of restorative dentistry.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hypoxic-ischaemic encephalopathy (HIE) is of major importance in neonatal and paediatric intensive care with regard to mortality and long-term morbidity. Our aim was to analyse our data in full-term neonates and children with special regard to withdrawal of life support and bad outcome. PATIENTS: All patients with HIE admitted to our unit from 1992-96 were analysed. Criteria for HIE were presence of a hypoxic insult followed by coma or altered consciousness with or without convulsions. Severity of HIE was assessed in neonates using Sarnat stages, and in children the duration of coma. In the majority of cases staging was completed with electrophysiological studies. Outcome was described using the Glasgow Outcome Scale. Bad outcome was defined as death, permanent vegetative state or severe disability, good outcome as moderate disability or good recovery. RESULTS: In the neonatal group (n = 38) outcome was significantly associated with Sarnat stages, presence of convulsions, severely abnormal EEG, cardiovascular failure, and multiple organ dysfunction (MOD). A bad outcome was observed in 27 cases with 14 deaths and 13 survivors. Supportive treatment was withdrawn in 14 cases with 9 subsequent deaths. In the older age group (n = 45) outcome was related to persistent coma of 24-48 h, severely abnormal EEG, cardiovascular failure, liver dysfunction and MOD. A bad outcome was found in 36 cases with 33 deaths and 3 survivors. Supportive treatment was withdrawn in 15 instances, all followed by death. CONCLUSIONS: Overall, neonates and older patients did not differ with regard to good or bad outcome. However, in the neonatal group there were significantly more survivors with bad outcome, either overall or after withdrawal of support. Possible explanations for this difference include variability of hypoxic insult, maturational and metabolic differences, and the more compliant neonatal skull, which prevents brainstem herniation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vertical profiles of stratospheric water vapour measured by the Michelson Interferometer for Passive Atmospheric Sounding (MIPAS) with the full resolution mode between September 2002 and March 2004 and retrieved with the IMK/IAA scientific retrieval processor were compared to a number of independent measurements in order to estimate the bias and to validate the existing precision estimates of the MIPAS data. The estimated precision for MIPAS is 5 to 10% in the stratosphere, depending on altitude, latitude, and season. The independent instruments were: the Halogen Occultation Experiment (HALOE), the Atmospheric Chemistry Experiment Fourier Transform Spectrometer (ACE-FTS), the Improved Limb Atmospheric Spectrometer-II (ILAS-II), the Polar Ozone and Aerosol Measurement (POAM III) instrument, the Middle Atmospheric Water Vapour Radiometer (MIAWARA), the Michelson Interferometer for Passive Atmospheric Sounding, balloon-borne version (MIPAS-B), the Airborne Microwave Stratospheric Observing System (AMSOS), the Fluorescent Stratospheric Hygrometer for Balloon (FLASH-B), the NOAA frostpoint hygrometer, and the Fast In Situ Hygrometer (FISH). For the in-situ measurements and the ground based, air- and balloon borne remote sensing instruments, the measurements are restricted to central and northern Europe. The comparisons to satellite-borne instruments are predominantly at mid- to high latitudes on both hemispheres. In the stratosphere there is no clear indication of a bias in MIPAS data, because the independent measurements in some cases are drier and in some cases are moister than the MIPAS measurements. Compared to the infrared measurements of MIPAS, measurements in the ultraviolet and visible have a tendency to be high, whereas microwave measurements have a tendency to be low. The results of χ2-based precision validation are somewhat controversial among the comparison estimates. However, for comparison instruments whose error budget also includes errors due to uncertainties in spectrally interfering species and where good coincidences were found, the χ2 values found are in the expected range or even below. This suggests that there is no evidence of systematically underestimated MIPAS random errors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE The purpose of this study was to document the long-term outcome of Brånemark implants installed in augmented maxillary bone and to identify parameters that are associated with peri-implant bone level. MATERIAL AND METHODS Patients of a periodontal practice who had been referred to a maxillofacial surgeon for iliac crest bone grafting in the atrophic maxilla were retrospectively recruited. Five months following grafting, they received 7-8 turned Brånemark implants. Following submerged healing of another 5 months, implants were uncovered and restorative procedures for fixed rehabilitation were initiated 2-3 months thereafter. The primary outcome variable was bone level defined as the distance from the implant-abutment interface to the first visible bone-to-implant contact. Secondary outcome variables included plaque index, bleeding index, probing depth, and levels of 40 species in subgingival plaque samples as identified by means of checkerboard DNA-DNA hybridization. RESULTS Nine out of 16 patients (eight females, one male; mean age 59) with 71 implants agreed to come in for evaluation after on average 9 years (SD 4; range 3-13) of function. One implant was deemed mobile at the time of inspection. Clinical conditions were acceptable with 11% of the implants showing pockets ≥ 5 mm. Periodontopathogens were encountered frequently and in high numbers. Clinical parameters and bacterial levels were highly patient dependent. The mean bone level was 2.30 mm (SD 1.53; range 0.00-6.95), with 23% of the implants demonstrating advanced resorption (bone level > 3 mm). Regression analysis showed a significant association of the patient (p < .001) and plaque index (p = .007) with bone level. CONCLUSIONS The long-term outcome of Brånemark implants installed in iliac crest-augmented maxillary bone is acceptable; however, advanced peri-implant bone loss is rather common and indicative of graft resorption. This phenomenon is patient dependent and seems also associated with oral hygiene.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The indications for direct resin composite restorations are nowadays extended due to the development of modern resin materials with improved material properties. However, there are still some difficulties regarding handling of resin composite material, especially in large restorations. The reconstruction of a functional and individual occlusion is difficult to achieve with direct application techniques. The aim of the present publication was to introduce a new "stamp"-technique for placing large composite restorations. The procedure of this "stamp"-technique is presented by three typical indications: large single-tooth restoration, occlusal rehabilitation of a compromised occlusal surface due to erosions and direct fibre-reinforced fixed partial denture. A step-by-step description of the technique and clinical figures illustrates the method. Large single-tooth restorations can be built-up with individual, two- piece silicone stamps. Large occlusal abrasive and/or erosive defects can be restored by copying the wax-up from the dental technician using the "stamp"-technique. Even fiber-reinforced resin-bonded fixed partial dentures can be formed with this intraoral technique with more precision and within a shorter treatment time. The presented "stamp"-technique facilitates the placement of large restoration with composite and can be recommended for the clinical use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE Mechanical thrombectomy using stent retriever devices have been advocated to increase revascularization in intracranial vessel occlusion. We present the results of a large prospective study on the use of the Solitaire Flow Restoration in patients with acute ischemic stroke. METHODS Solitaire Flow Restoration Thrombectomy for Acute Revascularization was an international, multicenter, prospective, single-arm study of Solitaire Flow Restoration thrombectomy in patients with large vessel anterior circulation strokes treated within 8 hours of symptom onset. Strict criteria for site selection were applied. The primary end point was the revascularization rate (thrombolysis in cerebral infarction ≥2b) of the occluded vessel as determined by an independent core laboratory. The secondary end point was the rate of good functional outcome (defined as 90-day modified Rankin scale, 0-2). RESULTS A total of 202 patients were enrolled across 14 comprehensive stroke centers in Europe, Canada, and Australia. The median age was 72 years, 60% were female patients. The median National Institute of Health Stroke Scale was 17. Most proximal intracranial occlusion was the internal carotid artery in 18%, and the middle cerebral artery in 82%. Successful revascularization was achieved in 79.2% of patients. Device and procedure-related severe adverse events were found in 7.4%. Favorable neurological outcome was found in 57.9%. The mortality rate was 6.9%. Any intracranial hemorrhagic transformation was found in 18.8% of patients, 1.5% were symptomatic. CONCLUSIONS In this single-arm study, treatment with the Solitaire Flow Restoration device in intracranial anterior circulation occlusions results in high rates of revascularization, low risk of clinically relevant procedural complications, and good clinical outcomes in combination with low mortality at 90 days. CLINICAL TRIAL REGISTRATION URL http://www.clinicaltrials.gov. Unique identifier: NCT01327989.