80 resultados para Free Space Optical Communication
Resumo:
There are about 650,000 people with hearing problems in Switzerland, 10,000 of whom use sign language. About 100,000 people are hard of hearing. Deaf patients require special treatment in the dental office as they have specific communication needs. This community, like many other minority groups, has a sign language and a culture of its own. To prevent misunderstandings it is therefore very important to provide solutions for an enhanced communication. However, guidelines for the communication with deaf dental patients are still missing. Successful communication between deaf patients and dentist is essential for effective care. This paper is concerned with providing background information and introducing recommendations for unrestricted dentist-patient communication. The aim of this article is to improve dentists' knowledge of the appropriate communication with this patient group.
Resumo:
Seasonal snow cover is of great environmental and socio-economic importance for the European Alps. Therefore a high priority has been assigned to quantifying its temporal and spatial variability. Complementary to land-based monitoring networks, optical satellite observations can be used to derive spatially comprehensive information on snow cover extent. For understanding long-term changes in alpine snow cover extent, the data acquired by the Advanced Very High Resolution Radiometer (AVHRR) sensors mounted onboard the National Oceanic and Atmospheric Association (NOAA) and Meteorological Operational satellite (MetOp) platforms offer a unique source of information. In this paper, we present the first space-borne 1 km snow extent climatology for the Alpine region derived from AVHRR data over the period 1985–2011. The objective of this study is twofold: first, to generate a new set of cloud-free satellite snow products using a specific cloud gap-filling technique and second, to examine the spatiotemporal distribution of snow cover in the European Alps over the last 27 yr from the satellite perspective. For this purpose, snow parameters such as snow onset day, snow cover duration (SCD), melt-out date and the snow cover area percentage (SCA) were employed to analyze spatiotemporal variability of snow cover over the course of three decades. On the regional scale, significant trends were found toward a shorter SCD at lower elevations in the south-east and south-west. However, our results do not show any significant trends in the monthly mean SCA over the last 27 yr. This is in agreement with other research findings and may indicate a deceleration of the decreasing snow trend in the Alpine region. Furthermore, such data may provide spatially and temporally homogeneous snow information for comprehensive use in related research fields (i.e., hydrologic and economic applications) or can serve as a reference for climate models.
Resumo:
BACKGROUND In 2006, bluetongue virus serotype 8 (BTV-8) was detected for the first time in central Europe. Measures to control the infection in livestock were implemented in Switzerland but the question was raised whether free-ranging wildlife could be a maintenance host for BTV-8. Furthermore Toggenburg orbivirus (TOV), considered as a potential 25th BTV serotype, was detected in 2007 in domestic goats in Switzerland and wild ruminants were considered a potential source of infection. To assess prevalences of BTV-8 and TOV infections in wildlife, we conducted a serological and virological survey in red deer, roe deer, Alpine chamois and Alpine ibex between 2009 and 2011. Because samples originating from wildlife carcasses are often of poor quality, we also documented the influence of hemolysis on test results, and evaluated the usefulness of confirmatory tests. RESULTS Ten out of 1,898 animals (0.5%, 95% confidence interval 0.3-1.0%) had detectable antibodies against BTV-8 and BTV-8 RNA was found in two chamois and one roe deer (0.3%, 0.1-0.8%). Seroprevalence was highest among red deer, and the majority of positive wild animals were sampled close to areas where outbreaks had been reported in livestock. Most samples were hemolytic and the range of the optical density percentage values obtained in the screening test increased with increasing hemolysis. Confirmatory tests significantly increased specificity of the testing procedure and proved to be applicable even on poor quality samples. Nearly all samples confirmed as positive had an optical density percentage value greater than 50% in the ELISA screening. CONCLUSIONS Prevalence of BTV-8 infection was low, and none of the tested animals were positive for TOV. Currently, wild ruminants are apparently not a reservoir for these viruses in Switzerland. However, we report for the first time BTV-8 RNA in Alpine chamois. This animal was found at high altitude and far from a domestic outbreak, which suggests that the virus could spread into/through the Alps. Regarding testing procedures, hemolysis did not significantly affect test results but confirmatory tests proved to be necessary to obtain reliable prevalence estimates. The cut-off value recommended by the manufacturer for the screening test was applicable for wildlife samples.
Resumo:
The Earth's bow shock is very efficient in accelerating ions out of the incident solar wind distribution to high energies (≈ 200 keV/e). Fluxes of energetic ions accelerated at the quasi-parallel bow shock, also known as diffuse ions, are best represented by exponential spectra in energy/charge, which require additional assumptions to be incorporated into these model spectra. One of these assumptions is a so-called "free escape boundary" along the interplanetary magnetic field into the upstream direction. Locations along the IBEX orbit are ideally suited for in situ measurements to investigate the existence of an upstream free escape boundary for bow shock accelerated ions. In this study we use 2 years of ion measurements from the background monitor on the IBEX spacecraft, supported by ACE solar wind observations. The IBEX Background Monitor is sensitive to protons > 14 keV, which includes the energy of the maximum flux for diffuse ions. With increasing distance from the bow shock along the interplanetary magnetic field, the count rates for diffuse ions stay constant for ions streaming away from the bow shock, while count rates for diffuse ions streaming toward the shock gradually decrease from a maximum value to ~1/e at distances of about 10 RE to 14 RE. These observations of a gradual decrease support the transition to a free escape continuum for ions of energy >14 keV at distances from 10 RE to 14 RE from the bow shock.
Resumo:
Foot-and-mouth disease (FMD) is highly contagious and one of the most economically devastating diseases of cloven-hoofed animals. Scientific-based preparedness about how to best control the disease in a previously FMD-free country is therefore essential for veterinary services. The present study used a spatial, stochastic epidemic simulation model to compare the effectiveness of emergency vaccination with conventional (non-vaccination) control measures in Switzerland, a low-livestock density country. Model results revealed that emergency vaccination with a radius of 3 km or 10 km around infected premises (IP) did not significantly reduce either the cumulative herd incidence or epidemic duration if started in a small epidemic situation where the number of IPs is still low. However, in a situation where the epidemic has become extensive, both the cumulative herd incidence and epidemic duration are reduced significantly if vaccination were implemented with a radius of 10 km around IPs. The effect of different levels of conventional strategy measures was also explored for the non-vaccination strategy. It was found that a lower compliance level of farmers for movement restrictions and delayed culling of IPs significantly increased both the cumulative IP incidence and epidemic duration. Contingency management should therefore focus mainly on improving conventional strategies, by increasing disease awareness and communication with stakeholders and preparedness of culling teams in countries with a livestock structure similar to Switzerland; however, emergency vaccination should be considered if there are reasons to believe that the epidemic may become extensive, such as when disease detection has been delayed and many IPs are discovered at the beginning of the epidemic.
Resumo:
The space-qualified design of a miniaturized laser for pulsed operation at a wavelength of 1064 nm and at repetition rates up to 10 Hz is presented. This laser consists of a pair of diode-laser pumped, actively q-switched Nd:YAG rod oscillators hermetically sealed and encapsulated in an environment of dry synthetic air. The system delivers at least 300 million laser pulses with 50 mJ energy and 5 ns pulse width (FWHM). It will be launched in 2017 aboard European Space Agency’s Mercury Planetary Orbiter as part of the BepiColombo Laser Altimeter, which, after a 6-years cruise, will start recording topographic data from orbital altitudes between 400 and 1500 km above Mercury’s surface.
Resumo:
We present a fluorescence-lifetime based method for monitoring cell and tissue activity in situ, during cell culturing and in the presence of a strong autofluorescence background. The miniature fiber-optic probes are easily incorporated in the tight space of a cell culture chamber or in an endoscope. As a first application we monitored the cytosolic calcium levels in porcine tracheal explant cultures using the Calcium Green-5N (CG5N) indicator. Despite the simplicity of the optical setup we are able to detect changes of calcium concentration as small as 2.5 nM, with a monitoring time resolution of less than 1 s.
Resumo:
Key performance features of a miniature laser ablation time-of-flight mass spectrometer designed for in situ investigations of the chemical composition of planetary surfaces are presented. This mass spectrometer is well suited for elemental and isotopic analysis of raw solid materials with high sensitivity and high spatial resolution. In this study, ultraviolet laser radiation with irradiances suitable for ablation (< 1 GW/cm2) is used to achieve stable ion formation and low sample consumption. In comparison to our previous laser ablation studies at infrared wavelengths, several improvements to the experimental setup have been made, which allow accurate control over the experimental conditions and good reproducibility of measurements. Current performance evaluations indicate significant improvements to several instrumental figures of merit. Calibration of the mass scale is performed within a mass accuracy (Δm/m) in the range of 100 ppm, and a typical mass resolution (m/Δm) ~600 is achieved at the lead mass peaks. At lower laser irradiances, the mass resolution is better, about (m/Δm) ~900 for lead, and limited by the laser pulse duration of 3 ns. The effective dynamic range of the instrument was enhanced from about 6 decades determined in previous study up to more than 8 decades at present. Current studies show high sensitivity in detection of both metallic and non-metallic elements. Their abundance down to tens of ppb can be measured together with their isotopic patterns. Due to strict control of the experimental parameters, e.g. laser characteristics, ion-optical parameters and sample position, by computer control, measurements can be performed with high reproducibility. Copyright © 2012 John Wiley & Sons, Ltd.
Resumo:
We measured the elemental composition on a sample of Allende meteorite with a miniature laser ablation mass spectrometer. This Laser Mass Spectrometer (LMS) has been designed and built at the University of Bern in the Department of Space Research and Planetary Sciences with the objective of using such an instrument on a space mission. Utilising the meteorite Allende as the test sample in this study, it is demonstrated that the instrument allows the in situ determination of the elemental composition and thus mineralogy and petrology of untreated rocky samples, particularly on planetary surfaces. In total, 138 measurements of elemental compositions have been carried out on an Allende sample. The mass spectrometric data are evaluated and correlated with an optical image. It is demonstrated that by illustrating the measured elements in the form of mineralogical maps, LMS can serve as an element imaging instrument with a very high spatial resolution of µm scale. The detailed analysis also includes a mineralogical evaluation and an investigation of the volatile element content of Allende. All findings are in good agreement with published data and underline the high sensitivity, accuracy and capability of LMS as a mass analyser for space exploration.
Resumo:
OBJECTIVES The aim of this case series was to introduce a complete digital workflow for the production of monolithic implant crowns. MATERIAL AND METHODS Six patients were treated with implant-supported crowns made of resin nano ceramic (RNC). Starting with an intraoral optical scan (IOS), and following a CAD/CAM process, the monolithic crowns were bonded either to a novel prefabricated titanium abutment base (group A) or to a CAD/CAM-generated individualized titanium abutment (group B) in premolar or molar sites on a soft tissue level dental implant. Economic analyses included clinical and laboratory steps. An esthetic evaluation was performed to compare the two abutment-crown combinations. RESULTS None of the digitally constructed RNC crowns required any clinical adaptation. Overall mean work time calculations revealed obvious differences for group A (65.3 min) compared with group B (86.5 min). Esthetic analysis demonstrated a more favorable outcome for the prefabricated bonding bases. CONCLUSIONS Prefabricated or individualized abutments on monolithic RNC crowns using CAD/CAM technology in a model-free workflow seem to provide a feasible and streamlined treatment approach for single-edentulous space rehabilitation in the posterior region. However, RNC as full-contour material has to be considered experimental, and further large-scale clinical investigations with long-term follow-up observation are necessary.
Resumo:
We present three methods for the distortion-free enhancement of THz signals measured by electro-optic sampling in zinc blende-type detector crystals, e.g., ZnTe or GaP. A technique commonly used in optically heterodyne-detected optical Kerr effect spectroscopy is introduced, which is based on two measurements at opposite optical biases near the zero transmission point in a crossed polarizer detection geometry. In contrast to other techniques for an undistorted THz signal enhancement, it also works in a balanced detection scheme and does not require an elaborate procedure for the reconstruction of the true signal as the two measured waveforms are simply subtracted to remove distortions. We study three different approaches for setting an optical bias using the Jones matrix formalism and discuss them also in the framework of optical heterodyne detection. We show that there is an optimal bias point in realistic situations where a small fraction of the probe light is scattered by optical components. The experimental demonstration will be given in the second part of this two-paper series [J. Opt. Soc. Am. B, doc. ID 204877 (2014, posted online)].