47 resultados para Failure time data analysis


Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE Based on a nation-wide database, this study analysed the influence of methotrexate (MTX), TNF inhibitors and a combination of the two on uveitis occurrence in JIA patients. METHODS Data from the National Paediatric Rheumatological Database in Germany were used in this study. Between 2002 and 2013, data from JIA patients were annually documented at the participating paediatric rheumatological sites. Patients with JIA disease duration of less than 12 months at initial documentation and ≥2 years of follow-up were included in this study. The impact of anti-inflammatory treatment on the occurrence of uveitis was evaluated by discrete-time survival analysis. RESULTS A total of 3,512 JIA patients (mean age 8.3±4.8 years, female 65.7%, ANA-positive 53.2%, mean age at arthritis onset 7.8±4.8 years) fulfilled the inclusion criteria. Mean total follow-up time was 3.6±2.4 years. Uveitis developed in a total of 180 patients (5.1%) within one year after arthritis onset. Uveitis onset after the first year was observed in another 251 patients (7.1%). DMARD treatment in the year before uveitis onset significantly reduced the risk for uveitis: MTX (HR 0.63, p=0.022), TNF inhibitors (HR 0.56, p<0.001) and a combination of the two (HR 0.10, p<0.001). Patients treated with MTX within the first year of JIA had an even a lower uveitis risk (HR 0.29, p<0.001). CONCLUSION The use of DMARDs in JIA patients significantly reduced the risk for uveitis onset. Early MTX use within the first year of disease and the combination of MTX with a TNF inhibitor had the highest protective effect. This article is protected by copyright. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION Every joint registry aims to improve patient care by identifying implants that have an inferior performance. For this reason, each registry records the implant name that has been used in the individual patient. In most registries, a paper-based approach has been utilized for this purpose. However, in addition to being time-consuming, this approach does not account for the fact that failure patterns are not necessarily implant specific but can be associated with design features that are used in a number of implants. Therefore, we aimed to develop and evaluate an implant product library that allows both time saving barcode scanning on site in the hospital for the registration of the implant components and a detailed description of implant specifications. MATERIALS AND METHODS A task force consisting of representatives of the German Arthroplasty Registry, industry, and computer specialists agreed on a solution that allows barcode scanning of implant components and that also uses a detailed standardized classification describing arthroplasty components. The manufacturers classified all their components that are sold in Germany according to this classification. The implant database was analyzed regarding the completeness of components by algorithms and real-time data. RESULTS The implant library could be set up successfully. At this point, the implant database includes more than 38,000 items, of which all were classified by the manufacturers according to the predefined scheme. Using patient data from the German Arthroplasty Registry, several errors in the database were detected, all of which were corrected by the respective implant manufacturers. CONCLUSIONS The implant library that was developed for the German Arthroplasty Registry allows not only on-site barcode scanning for the registration of the implant components but also its classification tree allows a sophisticated analysis regarding implant characteristics, regardless of brand or manufacturer. The database is maintained by the implant manufacturers, thereby allowing registries to focus their resources on other areas of research. The database might represent a possible global model, which might encourage harmonization between joint replacement registries enabling comparisons between joint replacement registries.