73 resultados para FIXED-BED COLUMNS
Resumo:
The complete dental rehabilitation of a patient with a failing dentition using fixed implant-supported prostheses requires carefully planned and well-sequenced treatment. This case report presents the treatment steps and sequencing for a patient in whom removable provisional prostheses were not an option. While an immediate loading protocol was used in the mandible, a staged approach featuring strategic extractions and implant placement in several phases was applied in the maxilla. The major advantage of this treatment protocol was that the patient was maintained in fixed prostheses throughout the treatment.
Resumo:
PURPOSE The purpose of this study was to document the long-term outcome of Brånemark implants installed in augmented maxillary bone and to identify parameters that are associated with peri-implant bone level. MATERIAL AND METHODS Patients of a periodontal practice who had been referred to a maxillofacial surgeon for iliac crest bone grafting in the atrophic maxilla were retrospectively recruited. Five months following grafting, they received 7-8 turned Brånemark implants. Following submerged healing of another 5 months, implants were uncovered and restorative procedures for fixed rehabilitation were initiated 2-3 months thereafter. The primary outcome variable was bone level defined as the distance from the implant-abutment interface to the first visible bone-to-implant contact. Secondary outcome variables included plaque index, bleeding index, probing depth, and levels of 40 species in subgingival plaque samples as identified by means of checkerboard DNA-DNA hybridization. RESULTS Nine out of 16 patients (eight females, one male; mean age 59) with 71 implants agreed to come in for evaluation after on average 9 years (SD 4; range 3-13) of function. One implant was deemed mobile at the time of inspection. Clinical conditions were acceptable with 11% of the implants showing pockets ≥ 5 mm. Periodontopathogens were encountered frequently and in high numbers. Clinical parameters and bacterial levels were highly patient dependent. The mean bone level was 2.30 mm (SD 1.53; range 0.00-6.95), with 23% of the implants demonstrating advanced resorption (bone level > 3 mm). Regression analysis showed a significant association of the patient (p < .001) and plaque index (p = .007) with bone level. CONCLUSIONS The long-term outcome of Brånemark implants installed in iliac crest-augmented maxillary bone is acceptable; however, advanced peri-implant bone loss is rather common and indicative of graft resorption. This phenomenon is patient dependent and seems also associated with oral hygiene.
Resumo:
OBJECTIVE To compare the precision of fit of full-arch implant-supported screw-retained computer-aided designed and computer-aided manufactured (CAD/CAM) titanium-fixed dental prostheses (FDP) before and after veneering. The null-hypothesis was that there is no difference in vertical microgap values between pure titanium frameworks and FDPs after porcelain firing. MATERIALS AND METHODS Five CAD/CAM titanium grade IV frameworks for a screw-retained 10-unit implant-supported reconstruction on six implants (FDI tooth positions 15, 13, 11, 21, 23, 25) were fabricated after digitizing the implant platforms and the cuspid-supporting framework resin pattern with a laser scanner (CARES(®) Scan CS2; Institut Straumann AG, Basel, Switzerland). A bonder, an opaquer, three layers of porcelain, and one layer of glaze were applied (Vita Titankeramik) and fired according to the manufacturer's preheating and fire cycle instructions at 400-800°C. The one-screw test (implant 25 screw-retained) was applied before and after veneering of the FDPs to assess the vertical microgap between implant and framework platform with a scanning electron microscope. The mean microgap was calculated from interproximal and buccal values. Statistical comparison was performed with non-parametric tests. RESULTS All vertical microgaps were clinically acceptable with values <90 μm. No statistically significant pairwise difference (P = 0.98) was observed between the relative effects of vertical microgap of unveneered (median 19 μm; 95% CI 13-35 μm) and veneered FDPs (20 μm; 13-31 μm), providing support for the null-hypothesis. Analysis within the groups showed significantly different values between the five implants of the FDPs before (P = 0.044) and after veneering (P = 0.020), while a monotonous trend of increasing values from implant 23 (closest position to screw-retained implant 25) to 15 (most distant implant) could not be observed (P = 0.169, P = 0.270). CONCLUSIONS Full-arch CAD/CAM titanium screw-retained frameworks have a high accuracy. Porcelain firing procedure had no impact on the precision of fit of the final FDPs. All implant microgap measurements of each FDP showed clinically acceptable vertical misfit values before and after veneering. Thus, the results do not only show accurate performance of the milling and firing but show also a reproducible scanning and designing process.
Resumo:
By means of fixed-links modeling, the present study identified different processes of visual short-term memory (VSTM) functioning and investigated how these processes are related to intelligence. We conducted an experiment where the participants were presented with a color change detection task. Task complexity was manipulated through varying the number of presented stimuli (set size). We collected hit rate and reaction time (RT) as indicators for the amount of information retained in VSTM and speed of VSTM scanning, respectively. Due to the impurity of these measures, however, the variability in hit rate and RT was assumed to consist not only of genuine variance due to individual differences in VSTM retention and VSTM scanning but also of other, non-experimental portions of variance. Therefore, we identified two qualitatively different types of components for both hit rate and RT: (1) non-experimental components representing processes that remained constant irrespective of set size and (2) experimental components reflecting processes that increased as a function of set size. For RT, intelligence was negatively associated with the non-experimental components, but was unrelated to the experimental components assumed to represent variability in VSTM scanning speed. This finding indicates that individual differences in basic processing speed, rather than in speed of VSTM scanning, differentiates between high- and low-intelligent individuals. For hit rate, the experimental component constituting individual differences in VSTM retention was positively related to intelligence. The non-experimental components of hit rate, representing variability in basal processes, however, were not associated with intelligence. By decomposing VSTM functioning into non-experimental and experimental components, significant associations with intelligence were revealed that otherwise might have been obscured.
Resumo:
The attentional blink phenomenon (AB) represents impaired identification of the second of two targets presented in rapid succession within a stream of stimuli. Despite the well-known association between attentional processes and psychometric intelligence (PI), evidence for a relationship between AB and PI is highly inconsistent. Theory and empirical findings suggest AB to be multifaceted. Hence, relations between AB and PI may be blurred when AB is measured as a single process. Furthermore, different aspects of PI might be differentially related to AB. The present study explored the relationship between processes underlying AB and general PI as well as specific aspects of PI (Reasoning, Speed, Memory, and Creativity) in 201 female students. Fixed-links modeling revealed three processes underlying AB: (1) a U-shaped process positively related to Speed and negatively related to Memory but unrelated to Reasoning, Creativity, and general PI, (2) an increasing process positively related to Reasoning, Speed, Memory, and general PI but not to Creativity, and (3) a decreasing process positively related to general PI and Memory but not to other aspects of PI. Our findings demonstrate that dissociating processes underlying AB and considering specific aspects of PI is required to understand the relationship between AB and PI.
Resumo:
When observers are presented with two visual targets appearing in the same position in close temporal proximity, a marked reduction in detection performance of the second target has often been reported, the so-called attentional blink phenomenon. Several studies found a similar decrement of P300 amplitudes during the attentional blink period as observed with detection performances of the second target. However, whether the parallel courses of second target performances and corresponding P300 amplitudes resulted from the same underlying mechanisms remained unclear. The aim of our study was therefore to investigate whether the mechanisms underlying the AB can be assessed by fixed-links modeling and whether this kind of assessment would reveal the same or at least related processes in the behavioral and electrophysiological data. On both levels of observation three highly similar processes could be identified: an increasing, a decreasing and a u-shaped trend. Corresponding processes from the behavioral and electrophysiological data were substantially correlated, with the two u-shaped trends showing the strongest association with each other. Our results provide evidence for the assumption that the same mechanisms underlie attentional blink task performance at the electrophysiological and behavioral levels as assessed by fixed-links models.
Resumo:
We investigate the 2-d O(3) model with a q-term as a toy model for slowly walking 4-d non-Abelian gauge theories. Using the very efficient meron-cluster algorithm, an accurate investigation of the scale dependence of the renormalized coupling is carried out for different values of the vacuum angle q. Approaching q = p, the infrared dynamics of the 2-d O(3) model is determined by a non-trivial conformal fixed point. We provide evidence for a slowly walking behavior near the fixed point and we perform a finite-size scaling analysis of the mass gap.