180 resultados para Emission Computed-tomography


Relevância:

100.00% 100.00%

Publicador:

Resumo:

After a mass fatality incident (MFI), all victims have to be rapidly and accurately identified for juridical reasons as well as for the relatives' sake. Since MFIs are often international in scope, Interpol has proposed standard disaster victim identification (DVI) procedures, which have been widely adopted by authorities and forensic experts. This study investigates how postmortem multislice computed tomography (MSCT) can contribute to the DVI process as proposed by Interpol. The Interpol postmortem (PM) form has been analyzed, and a number of items in sections D and E thereof have been postulated to be suitable for documentation by CT data. CT scans have then been performed on forensic cases. Interpretation of the reconstructed images showed that indeed much of the postmortem information required for identification can be gathered from CT data. Further advantages of the proposed approach concern the observer independent documentation, the possibility to reconstruct a variety of images a long time after the event, the possibility to distribute the work by transmitting CT data digitally, and the reduction of time and specialists needed at the disaster site. We conclude that MSCT may be used as a valuable screening tool in DVI in the future.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: This study sought to evaluate the diagnostic accuracy of coronary binary in-stent restenosis (ISR) with angiography using 64-slice multislice computed tomography coronary angiography (CTCA) compared with invasive coronary angiography (ICA). BACKGROUND: A noninvasive detection of ISR would result in an easier and safer way to conduct patient follow-up. METHODS: We performed CTCA in 81 patients after stent implantation, and 125 stented lesions were scanned. Two sets of images were reconstructed with different types of convolution kernels. On CTCA, neointimal proliferation was visually evaluated according to luminal contrast attenuation inside the stent. Lesions were graded as follows: grade 1, none or slight neointimal proliferation; grade 2, neointimal proliferation with no significant stenosis (<50%); grade 3, neointimal proliferation with moderate stenosis (> or =50%); and grade 4, neointimal proliferation with severe stenosis (> or =75%). Grades 3 and 4 were considered binary ISR. The diagnostic accuracy of CTCA compared with ICA was evaluated. RESULTS: By ICA, 24 ISRs were diagnosed. Sensitivity, specificity, positive predictive value, and negative predictive value were 92%, 81%, 54%, and 98% for the overall population, whereas values were 91%, 93%, 77%, and 98% when excluding unassessable segments (15 segments, 12%). For assessable segments, CTCA correctly diagnosed 20 of the 22 ISRs detected by ICA. Six lesions without ISR were overestimated as ISR by CTCA. As the grade of neointimal proliferation by CTCA increases, the median value of percent diameter stenosis increased linearly. CONCLUSIONS: Binary ISR can be excluded with high probability by CTCA, with a moderate rate of false-positive results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Multislice computed tomography (MSCT) is a promising noninvasive method of detecting coronary artery disease (CAD). However, most data have been obtained in selected series of patients. The purpose of the present study was to investigate the accuracy of 64-slice MSCT (64 MSCT) in daily practice, without any patient selection. METHODS AND RESULTS: Using 64-slice MSCT coronary angiography (CTA), 69 consecutive patients, 39 (57%) of whom had previously undergone stent implantation, were evaluated. The mean heart rate during scan was 72 beats/min, scan time 13.6 s and the amount of contrast media 72 mL. The mean time span between invasive coronary angiography (ICAG) and CTA was 6 days. Significant stenosis was defined as a diameter reduction of > 50%. Of 966 segments, 884 (92%) were assessable. Compared with ICAG, the sensitivity of CTA to diagnose significant stenosis was 90%, specificity 94%, positive predictive value (PPV) 89% and negative predictive value (NPV) 95%. With regard to 58 stented lesions, the sensitivity, specificity, PPV and NPV were 93%, 96%, 87% and 98%, respectively. On the patient-based analysis, the sensitivity, specificity, PPV and NPV of CTA to detect CAD were 98%, 86%, 98% and 86%, respectively. Eighty-two (8%) segments were not assessable because of irregular rhythm, calcification or tachycardia. CONCLUSION: Sixty-four-MSCT has a high accuracy for the detection of significant CAD in an unselected patient population and therefore can be considered as a valuable noninvasive technique.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Current concepts of catheter ablation for atrial fibrillation (AF) commonly use three-dimensional (3D) reconstructions of the left atrium (LA) for orientation, catheter navigation, and ablation line placement. OBJECTIVES: The purpose of this study was to compare the 3D electroanatomic reconstruction (Carto) of the LA, pulmonary veins (PVs), and esophagus with the true anatomy displayed on multislice computed tomography (CT). METHODS: In this prospective study, 100 patients undergoing AF catheter ablation underwent contrast-enhanced spiral CT scan with barium swallow and subsequent multiplanar and 3D reconstructions. Using Carto, circumferential plus linear LA lesions were placed. The esophagus was tagged and integrated into the Carto map. RESULTS: Compared with the true anatomy on CT, the electroanatomic reconstruction accurately displayed the true distance between the lower PVs; the distances between left upper PV, left lower PV, right lower PV, and center of the esophagus; the longitudinal diameter of the encircling line around the funnel of the left PVs; and the length of the mitral isthmus line. Only the distances between the upper PVs, the distance between the right upper PV and esophagus, and the diameter of the right encircling line were significantly shorter on the electroanatomic reconstructions. Furthermore, electroanatomic tagging of the esophagus reliably visualized the true anatomic relationship to the LA. On multiple tagging and repeated CT scans, the LA and esophagus showed a stable anatomic relationship, without relevant sideward shifting of the esophagus. CONCLUSION: Electroanatomic reconstruction can display with high accuracy the true 3D anatomy of the LA and PVs in most of the regions of interest for AF catheter ablation. In addition, Carto was able to visualize the true anatomic relationship between the esophagus and LA. Both structures showed a stable anatomic relationship on Carto and CT without relevant sideward shifting of the esophagus.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to identify the classic autopsy signs of drowning in post-mortem multislice computed tomography (MSCT). Therefore, the post-mortem pre-autopsy MSCT- findings of ten drowning cases were correlated with autopsy and statistically compared with the post-mortem MSCT of 20 non-drowning cases. Fluid in the airways was present in all drowning cases. Central aspiration in either the trachea or the main bronchi was usually observed. Consecutive bronchospasm caused emphysema aquosum. Sixty percent of drowning cases showed a mosaic pattern of the lung parenchyma due to regions of hypo- and hyperperfused lung areas of aspiration. The resorption of fresh water in the lung resulted in hypodensity of the blood representing haemodilution and possible heart failure. Swallowed water distended the stomach and duodenum; and inflow of water filled the paranasal sinuses (100%). All the typical findings of drowning, except Paltau's spots, were detected using post-mortem MSCT, and a good correlation of MSCT and autopsy was found. The advantage of MSCT was the direct detection of bronchospasm, haemodilution and water in the paranasal sinus, which is rather complicated or impossible at the classical autopsy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To evaluate a triphasic injection protocol for whole-body multidetector computed tomography (MDCT) in patients with multiple trauma. Fifty consecutive patients (41 men) were examined. Contrast medium (300 mg/mL iodine) was injected starting with 70 mL at 3 mL/s, followed by 0.1 mL/s for 8 s, and by another bolus of 75 mL at 4 mL/s. CT data acquisition started 50 s after the beginning of the first injection. Two experienced, blinded readers independently measured the density in all major arteries, veins, and parenchymatous organs. Image quality was assessed using a five-point ordinal rating scale and compared to standard injection protocols [n = 25 each for late arterial chest, portovenous abdomen, and MDCT angiography (CTA)]. With the exception of the infrarenal inferior caval vein, all blood vessels were depicted with diagnostic image quality using the multiple-trauma protocol. Arterial luminal density was slightly but significantly smaller compared to CTA (P < 0.01). Veins and parenchymatous organs were opacified significantly better compared to all other protocols (P < 0.01). Arm artifacts reduced the density of spleen and liver parenchyma significantly (P < 0.01). Similarly high image quality is achieved for arteries using the multiple-trauma protocol compared to CTA, and parenchymatous organs are depicted with better image quality compared to specialized protocols. Arm artifacts should be avoided.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We aimed at assessing stent geometry and in-stent contrast attenuation with 64-slice CT in patients with various coronary stents. Twenty-nine patients (mean age 60 +/- 11 years; 24 men) with 50 stents underwent CT within 2 weeks after stent placement. Mean in-stent luminal diameter and reference vessel diameter proximal and distal to the stent were assessed with CT, and compared to quantitative coronary angiography (QCA). Stent length was also compared to the manufacturer's values. Images were reconstructed using a medium-smooth (B30f) and sharp (B46f) kernel. All 50 stents could be visualized with CT. Mean in-stent luminal diameter was systematically underestimated with CT compared to QCA (1.60 +/- 0.39 mm versus 2.49 +/- 0.45 mm; P < 0.0001), resulting in a modest correlation of QCA versus CT (r = 0.49; P < 0.0001). Stent length as given by the manufacturer was 18.2 +/- 6.2 mm, correlating well with CT (18.5 +/- 5.7 mm; r = 0.95; P < 0.0001) and QCA (17.4 +/- 5.6 mm; r = 0.87; P < 0.0001). Proximal and distal reference vessel diameters were similar with CT and QCA (P = 0.06 and P = 0.03). B46f kernel images showed higher image noise (P < 0.05) and lower in-stent CT attenuation values (P < 0.001) than images reconstructed with the B30f kernel. 64-slice CT allows measurement of coronary artery in-stent density, and significantly underestimates the true in-stent diameter compared to QCA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to obtain comprehensive data on clinical presentation, microbiology, computed tomography, surgical findings and histology in acute, sub-acute and chronic mastoiditis. We performed a prospective, observational study in children under 16 years of age presenting to our institution during the 2-year period beginning in April 2000. The children were examined and their condition treated in accordance with a standardized protocol elaborated by the paediatric, otolaryngology (ORL) and radiology departments. Thirty-eight patients were hospitalized (22 with acute mastoiditis, seven with sub-acute mastoiditis, nine with chronic mastoiditis). There were 30 complications present in 21 patients (55%). Streptococcus pyogenes was the most common pathogen (7/24 cases), followed by Streptococcus pneumoniae (4/24 cases). Mastoid surgery was performed in 29 patients. Histology of mastoid tissue revealed predominantly acute inflammation in two cases, mixed acute/chronic inflammation in 19 cases and predominantly chronic inflammation in seven cases. Radiologic data were evaluated retrospectively. Spiral, volume-based high-resolution (HR) computed tomography (CT) of the temporal bone had a sensitivity of 100%, specificity of 38%, positive predictive value (PPV) of 50% and negative predictive value (NPV) of 100% in detecting coalescence of mastoid trabeculae. Cranial CT with contrast had a sensitivity of 80%, specificity of 94%, PPV of 80% and NPV of 94% in identifying intra-cranial extension. Conclusion: histological evidence suggests that sub-acute/chronic infection underlies not only sub-acute and chronic mastoiditis, but most cases of acute mastoiditis as well. HR-CT of the temporal bone is effective in ruling out coalescence. Cranial CT is valuable in identifying intra-cranial extension. Cranial and HR-CT are recommended in the examination of children with mastoiditis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Melatonin has been postulated to have diverse properties, acting as an antioxidant, a neuroprotector, or a stabilizer within the circadian timing system, and is thus thought to be involved in the aging process and Alzheimer's disease (AD). We used computed tomography to determine the degree of pineal calcification (DOC), an intra-individual melatonin deficit marker, as well as the size of uncalcified pineal tissue, in 279 consecutive memory clinic outpatients (AD: 155; other dementia: 25; mild cognitive impairment: 33; depression: 66) and 37 age-matched controls. The size of uncalcified pineal tissue in patients with AD (mean 0.15 cm(2) [S.D. 0.24]) was significantly smaller than in patients with other types of dementia (0.26 [0.34]; P=0.038), with depression (0.28 [0.34]; P=0.005), or in controls (0.25 [0.31]; P=0.027). Additionally, the DOC in patients with AD (mean 76.2% [S.D. 26.6]) was significantly higher than in patients with other types of dementia (63.7 [34.7]; P=0.042), with depression (60.5 [33.8]; P=0.001), or in controls (64.5 [30.6]; P=0.021). These two findings may reflect two different aspects of melatonin in AD. On the one hand, the absolute amount of melatonin excretion capability, as indicated by uncalcified pineal volume, refers to the antioxidant properties of melatonin. On the other hand, the relative reduction in melatonin production capability in the individual, as indicated by DOC, refers to the circadian properties of melatonin.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the present study, dose measurements have been conducted following examination of the maxilla and mandible with spiral computed tomography (CT). The measurements were carried out with 2 phantoms, a head and neck phantom and a full body phantom. The analysis of applied thermoluminescent dosimeters yielded radiation doses for organs and tissues in the head and neck region between 0.6 and 16.7 mGy when 40 axial slices and 120 kV/165 mAs were used as exposure parameters. The effective dose was calculated as 0.58 and 0.48 mSv in the maxilla and mandible, respectively. Tested methods for dose reduction showed a significant decrease of radiation dose from 40 to 65%. Based on these results, the mortality risk was estimated according to calculation models recommended by the Committee on the Biological Effects of Ionizing Radiations and by the International Commission on Radiological Protection. Both models resulted in similar values. The mortality risk ranges from 46.2 x 10.6 for 20-year-old men to 11.2 x 10(-6) for 65-year-old women. Using 2 methods of dose reduction, the mortality risk decreased by approximately 50 to 60% to 19.1 x 10(-6) for 20-year-old men and 5.5 x 10(-6) for 65-year-old women. It can be concluded that a CT scan of the maxillofacial complex causes a considerable radiation dose when compared with conventional radiographic examinations. Therefore, a careful indication for this imaging technique and dose reduction methods should be considered in daily practice.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Using postmortem multislice computed tomography (MSCT) and magnetic resonance imaging (MRI), 40 forensic cases were examined and findings were verified by subsequent autopsy. Results were classified as follows: (I) cause of death, (II) relevant traumatological and pathological findings, (III) vital reactions, (IV) reconstruction of injuries, (V) visualization. In these 40 forensic cases, 47 partly combined causes of death were diagnosed at autopsy, 26 (55%) causes of death were found independently using only radiological image data. Radiology was superior to autopsy in revealing certain cases of cranial, skeletal, or tissue trauma. Some forensic vital reactions were diagnosed equally well or better using MSCT/MRI. Radiological imaging techniques are particularly beneficial for reconstruction and visualization of forensic cases, including the opportunity to use the data for expert witness reports, teaching, quality control, and telemedical consultation. These preliminary results, based on the concept of "virtopsy," are promising enough to introduce and evaluate these radiological techniques in forensic medicine.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Component malpositioning and postoperative leg length discrepancy are the most common technical problems associated with total hip arthroplasty (THA). Surgical navigation offers the potential to reduce the incidence of these problems. We reviewed 317 patients (344 hips) that underwent THA using computed tomography-based surgical navigation, including 112 THAs using a simplified method of measuring leg length. Guided by the navigation system, cups were placed in 40.8 degrees +/- 2 degrees of operative abduction (range, 35 degrees -50 degrees) and 30.8 degrees +/- 3.2 degrees (range, 19 degrees -43 degrees) of operative anteversion. We subsequently measured radiographic abduction on plain anteroposterior pelvic radiographs and calculated abduction and anteversion. Radiographically, 97.1 % of the cups were in the safe zone for abduction and 92.4% for anteversion. The mean incision length was less than 8 cm for 327 of the 344 hips. Leg length change measured intraoperatively was 6.6 +/- 4.1 mm (range, -2-22), similar to measurements from the pre- and postoperative magnification-corrected radiographs. Computer assistance during THA increased the consistency of component positioning and allowed reliable measurement of leg length change during surgery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: The aim of this phantom study was to evaluate the contrast-to-noise ratio (CNR) in pulmonary computed tomography (CT)-angiography for 300 and 400 mg iodine/mL contrast media using variable x-ray tube parameters and patient sizes. We also analyzed the possible strategies of dose reduction in patients with different sizes. MATERIALS AND METHODS: The segmental pulmonary arteries were simulated by plastic tubes filled with 1:30 diluted solutions of 300 and 400 mg iodine/mL contrast media in a chest phantom mimicking thick, intermediate, and thin patients. Volume scanning was done with a CT scanner at 80, 100, 120, and 140 kVp. Tube current-time products (mAs) varied between 50 and 120% of the optimal value given by the built-in automatic dose optimization protocol. Attenuation values and CNR for both contrast media were evaluated and compared with the volume CT dose index (CTDI(vol)). Figure of merit, calculated as CNR/CTDIvol, was used to quantify image quality improvement per exposure risk to the patient. RESULTS: Attenuation of iodinated contrast media increased both with decreasing tube voltage and patient size. A CTDIvol reduction by 44% was achieved in the thin phantom with the use of 80 instead of 140 kVp without deterioration of CNR. Figure of merit correlated with kVp in the thin phantom (r = -0.897 to -0.999; P < 0.05) but not in the intermediate and thick phantoms (P = 0.09-0.71), reflecting a decreasing benefit of tube voltage reduction on image quality as the thickness of the phantom increased. Compared with the 300 mg iodine/mL concentration, the same CNR for 400 mg iodine/mL contrast medium was achieved at a lower CTDIvol by 18 to 40%, depending on phantom size and applied tube voltage. CONCLUSIONS: Low kVp protocols for pulmonary embolism are potentially advantageous especially in thin and, to a lesser extent, in intermediate patients. Thin patients profit from low voltage protocols preserving a good CNR at a lower exposure. The use of 80 kVp in obese patients may be problematic because of the limitation of the tube current available, reduced CNR, and high skin dose. The high CNR of the 400 mg iodine/mL contrast medium together with lower tube energy and/or current can be used for exposure reduction.