61 resultados para Electrical-stimulation


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: Cardiomyocytes are terminally differentiated cells in the adult heart and ischemia and cardiotoxic compounds can lead to cell death and irreversible decline of cardiac function. As testing platforms, isolated organs and primary cells from rodents have been the standard in research and toxicology, but there is a need for better models that more faithfully recapitulate native human biology. Hence, a new in vitro model comprising the advantages of 3D cell culture and the availability of induced pluripotent stem cells (iPSC) from human origin was developed and characterized. Methods: Human cardiomyocytes (CMs) derived from induced pluripotent stem cells (iPSCs) were studied in standard 2D culture and as cardiac microtissues (MTs) formed in hanging drops. 2D cultures were examined using immunofluorescence microscopy and Western blotting while the cardiac MTs were subjected to immunofluorescence, contractility, and pharmacological investigations. Results: iPSC-derived CMs in 2D culture showed well-formed myofibrils, cell-cell contacts positive for connexin-43, and other typical cardiac proteins. The cells reacted to pro-hypertrophic growth factors with a substantial increase in myofibrils and sarcomeric proteins. In hanging drop cultures, iPSC-derived cardiomyocytes formed spheroidal MTs within 4 days showing a homogeneous tissue structure with well-developed myofibrils extending throughout the whole spheroid without a necrotic core. MTs showed spontaneous contractions for more than 4 weeks that were recorded by optical motion tracking, sensitive to temperature, and responsive to electrical pacing. Contractile pharmacology was tested with several agents known to modulate cardiac rate and viability. Calcium-transients underlay the contractile activity and were also responsive to electrical stimulation, caffeine-induced Ca2+-release, extracellular calcium levels. Conclusions: 3D culture using iPSC-derived human cardiomyocytes provides an organoid human-based cellular platform that is free of necrosis and recapitulates vital cardiac functionality, thereby providing new and promising relevant model for the evaluation and development of new therapies and detection of cardiotoxicity.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Our aim was to distinguish between spinal and supraspinal mechanisms in the intact nervous system by comparing homosegmental and heterosegmental effects of electroacupuncture (EA) and manual acupuncture (MA) on sensory perception in healthy volunteers by means of quantitative sensory testing. Seventy-two healthy volunteers were randomly assigned to receive either MA or EA at SP 6, SP 9, GB 39, and ST 36 at the left leg or relaxed for 30 minutes (control group [CG]). Blinded examiners assessed 13 sensory modalities (thermal and mechanical detection and pain thresholds) at the upper arms and lower legs before and after intervention by means of a standardized quantitative sensory testing battery. Change scores of all 13 sensory thresholds were compared between groups. The main outcome measure was the change score of the pressure pain threshold (PPT). There were no baseline differences between groups. Pressure pain threshold change scores at the lower left leg, in the same segment as the needling site, differed significantly (P = 0.008) between the EA (median: 103.01 kPa) and CG groups (median: 0.00 kPa) but not between the MA (median: 0.00 kPa) and CG groups. No further significant change score differences were found between one of the acupuncture groups and the CG. The PPT can be changed by EA. The PPT increase was confined to the segment of needling, which indicates that it is mainly mediated by segmental inhibition in the spinal cord. This underscores the importance of segmental needling and electrical stimulation in clinical practice.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Hypersensitivity of pain pathways is considered a relevant determinant of symptoms in chronic pain patients, but data on its prevalence are very limited. To our knowledge, no data on the prevalence of spinal nociceptive hypersensitivity are available. We studied the prevalence of pain hypersensitivity and spinal nociceptive hypersensitivity in 961 consecutive patients with various chronic pain conditions. Pain threshold and nociceptive withdrawal reflex threshold to electrical stimulation were used to assess pain hypersensitivity and spinal nociceptive hypersensitivity, respectively. Using 10th percentile cutoff of previously determined reference values, the prevalence of pain hypersensitivity and spinal nociceptive hypersensitivity (95% confidence interval) was 71.2 (68.3-74.0) and 80.0 (77.0-82.6), respectively. As a secondary aim, we analyzed demographic, psychosocial, and clinical characteristics as factors potentially associated with pain hypersensitivity and spinal nociceptive hypersensitivity using logistic regression models. Both hypersensitivity parameters were unaffected by most factors analyzed. Depression, catastrophizing, pain-related sleep interference, and average pain intensity were significantly associated with hypersensitivity. However, none of them was significant for both unadjusted and adjusted analyses. Furthermore, the odds ratios were very low, indicating modest quantitative impact. To our knowledge, this is the largest prevalence study on central hypersensitivity and the first one on the prevalence of spinal nociceptive hypersensitivity in chronic pain patients. The results revealed an impressively high prevalence, supporting a high clinical relevance of this phenomenon. Electrical pain thresholds and nociceptive withdrawal reflex explore aspects of pain processing that are mostly independent of sociodemographic, psychological, and clinical pain-related characteristics.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The pain and distress associated with transcutaneous electrical nerve stimulation (TENS) of the udder was evaluated by treating 20 healthy dairy cows with an electrical udder stimulator. This generated a sequence of pulses (frequency: 160+/-10% impulses per second, duration 250 mus) and provided voltage ranges from 0 to 10 volts (+/-10%). Trials took place on three consecutive days, twice daily after morning and evening milking. Daily sessions were divided into two periods: (1) control (sham treatment) and (2) treatment (real treatment). Physiological (heart rate, respiratory rate, and plasma cortisol concentration) as well as ethological parameters (kicking, weight shifting, and looking backwards to udder) were defined as pain-indicating parameters and observed. Evaluation of data showed that only one parameter (kicking) was significantly increased during real treatment compared to sham treatment. It is concluded that the TENS therapy tested in this study can evoke changes in behaviour (increased kicking) consistent with an experience of pain in some cows.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Permission from the ethics committee and informed consent were obtained. The purpose of this study was to prospectively evaluate a method developed for the noninvasive assessment of muscle metabolites during exercise. Hydrogen 1 magnetic resonance (MR) spectroscopy peaks were measured during tetanic isometric muscle contraction imposed by supramaximal repetitive nerve stimulation. The kinetics of creatine-phosphocreatine and acetylcarnitine signal changes (P < .001) could be assessed continuously before, during, and after exercise. The control peak (trimethylammonium compounds), which served as an internal reference, did not change. This technique-that is, functional MR spectroscopy-opens the possibility for noninvasive diagnostic muscle metabolite testing in a clinical setting.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: Intradialytic exercise has been described to improve blood pressure stability and dialysis efficacy. However, comorbid conditions in the dialysis population often preclude the widespread use of active intradialytic exercise. Therefore, we investigated the effect of intradialytic transcutaneous muscle stimulation (TEMS) and passive cycling movements (PCMs) on blood pressure and dialysis efficacy in patients. STUDY DESIGN: Prospective, controlled, randomized, crossover investigation. SETTING ; PARTICIPANTS: Ten patients were randomly allocated to TEMS, PCMs, or no intervention (NI) for 9 consecutive dialysis sessions. INTERVENTION: Participants were studied with NI, PCMs using a motor-driven ergometer, and bilateral TEMS of the leg musculature. Individual dialysis prescriptions were unchanged during the investigation. OUTCOMES ; MEASUREMENTS: The effect of TEMS and PCMs on blood pressure and dialysis efficacy in patients was assessed. RESULTS: Mean blood pressure increased from 121/64 +/- 21/15 mm Hg with NI to 132/69 +/- 21/15 mm Hg (P < 0.001) during sessions with PCMs and 125/66 +/- 22/16 mm Hg (P < 0.05) during sessions with TEMS. Urea and phosphate removal during dialysis were significantly (P < 0.001) greater with TEMS (19.4 +/- 3.7 g/dialysis and 1,197 +/- 265 mg/dialysis) or PCMs (20.1 +/- 3.4 g/dialysis and 1,172 +/- 315 mg/dialysis) than with NI (15.1 +/- 3.9 g/dialysis and 895 +/- 202 mg/dialysis). Body weight, ultrafiltration, Kt/V, and increases in hemoglobin and albumin levels during dialysis did not differ among the NI, PCMs, and TEMS groups. LIMITATIONS: The study design does not allow extension of the findings to prolonged treatment. CONCLUSION: Future studies during longer observation periods will have to prove the persistence of these acute findings. Both TEMS and PCMs deserve future investigations in dialysis patients because they increase intradialytic blood pressure and facilitate urea and phosphate removal when applied short term.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective To evaluate the effect of transcutaneous electrical nerve stimulation (TENS) for treating men with refractory chronic pelvic pain syndrome (CPPS). Patients and Methods A consecutive series of 60 men treated with TENS for refractory CPPS was evaluated prospectively at an academic tertiary referral centre. The effects of treatment were evaluated by a pain diary and by the quality of life item of the National Institutes of Health Chronic Prostatitis Symptom Index at baseline, after 12 weeks of TENS treatment, and at last known follow-up. Adverse events related to TENS were also assessed. Results The mean (95% confidence interval, CI; range) age of the 60 men was 46.9 (43.5–50.3; 21–82) years. TENS was successful after 12 weeks of treatment in 29 (48%) patients and a positive effect was sustained during a mean (95%, CI; range) follow-up of 43.6 (33.2–56; 6–88) months in 21 patients. After 12 weeks of TENS treatment, mean (95% CI) pain visual analogue scale decreased significantly (P < 0.001) from 6.6 (6.3–6.9) to 3.9 (3.2–4.6). Patients' quality of life changed significantly after TENS treatment (P < 0.001). Before TENS, all 60 patients felt mostly dissatisfied (n = 17; 28%), unhappy (n = 28; 47%) or terrible (n = 15; 25%). After 12 weeks of TENS treatment, 29 (48%) patients felt mostly satisfied (n = 5), pleased (n = 18) or delighted (n = 6). No adverse events related to TENS were noted. Conclusion TENS may be an effective and safe treatment for refractory CPPS in men, warranting randomized, placebo-controlled trials.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

PURPOSE: To assess the effect of transcutaneous electrical nerve stimulation (TENS) for treating refractory overactive bladder syndrome (OAB). PATIENTS AND METHODS: A consecutive series of 42 patients treated with TENS for refractory OAB was prospectively investigated at an academic tertiary referral centre. Effects were evaluated using bladder diary for at least 48 h and satisfaction assessment at baseline, after 12 weeks of TENS treatment, and at the last known follow-up. Adverse events related to TENS were also assessed. RESULTS: Mean age of the 42 patients (25 women, 17 men) was 48 years (range, 18-76). TENS was successful following 12 weeks of treatment in 21 (50 %) patients, and the positive effect was sustained during a mean follow-up of 21 months (range, 6-83 months) in 18 patients. Following 12 weeks of TENS treatment, mean number of voids per 24 h decreased significantly from 15 to 11 (p < 0.001) and mean voided volume increased significantly from 160 to 230 mL (p < 0.001). In addition, TENS completely restored continence in 7 (39 %) of the 18 incontinent patients. Before TENS, all 42 patients were dissatisfied or very dissatisfied; following 12 weeks of TENS treatment, 21 (50 %) patients felt satisfied or very satisfied (p < 0.001). No adverse events related to TENS were noted. CONCLUSIONS: TENS seems to be an effective and safe treatment for refractory OAB warranting randomized, placebo-controlled trials.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The Barostim neo ™ system is a novel implantable device that activates the carotid baroreflex. It decreases the sympathetic activity and inhibits the renin system, which results in reduced blood pressure and heart rate. In patients with resistant hypertension, electrically activation of the baroreflex leads to an average decrease in systolic blood pressure of 38, 36, 40 and 53 mmHg at 1, 2, 3 and 4 years, respectively. Additionally, cardiac remodelling with reduced left ventricular mass and posterior wall thickness has been observed in long-term studies. In a limited number of patients with heart failure, baroreflex activation therapy leads to a decrease in muscle sympathetic nerve activity and to improved quality of life and functional capacities. The implantation procedure is safe and associated with risks comparable with those of other active implantable devices. Barostim neo is currently available in several European countries.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

CONTEXT Transcutaneous electrical nerve stimulation (TENS) is a promising therapy for non-neurogenic lower urinary tract dysfunction and might also be a valuable option in patients with an underlying neurological disorder. OBJECTIVE We systematically reviewed all available evidence on the efficacy and safety of TENS for treating neurogenic lower urinary tract dysfunction. EVIDENCE ACQUISITION The review was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses Statement. EVIDENCE SYNTHESIS After screening 1943 articles, 22 studies (two randomised controlled trials, 14 prospective cohort studies, five retrospective case series, and one case report) enrolling 450 patients were included. Eleven studies reported on acute TENS and 11 on chronic TENS. In acute TENS and chronic TENS, the mean increase of maximum cystometric capacity ranged from 69ml to 163ml and from 4ml to 156ml, the mean change of bladder volume at first detrusor overactivity from a decrease of 13ml to an increase of 175ml and from an increase of 10ml to 120ml, a mean decrease of maximum detrusor pressure at first detrusor overactivity from 18 cmH20 to 72 cmH20 and 8 cmH20, and a mean decrease of maximum storage detrusor pressure from 20 cmH20 to 58 cmH2O and from 3 cmH20 to 8 cmH2O, respectively. In chronic TENS, a mean decrease in the number of voids and leakages per 24h ranged from 1 to 3 and from 0 to 4, a mean increase of maximum flow rate from 2ml/s to 7ml/s, and a mean change of postvoid residual from an increase of 26ml to a decrease of 85ml. No TENS-related serious adverse events have been reported. Risk of bias and confounding was high in most studies. CONCLUSIONS Although preliminary data suggest TENS might be effective and safe for treating neurogenic lower urinary tract dysfunction, the evidence base is poor and more reliable data from well-designed randomised controlled trials are needed to make definitive conclusions. PATIENT SUMMARY Early data suggest that transcutaneous electrical nerve stimulation might be effective and safe for treating neurogenic lower urinary tract dysfunction, but more reliable evidence is required.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new hearing therapy based on direct acoustic cochlear stimulation was developed for the treatment of severe to profound mixed hearing loss. The device efficacy was validated in an initial clinical trial with four patients. This semi-implantable investigational device consists of an externally worn audio processor, a percutaneous connector, and an implantable microactuator. The actuator is placed in the mastoid bone, right behind the external auditory canal. It generates vibrations that are directly coupled to the inner ear fluids and that, therefore, bypass the external and the middle ear. The system is able to provide an equivalent sound pressure level of 125 dB over the frequency range between 125 and 8000 Hz. The hermetically sealed actuator is designed to provide maximal output power by keeping its dimensions small enough to enable implantation. A network model is used to simulate the dynamic characteristics of the actuator to adjust its transfer function to the characteristics of the middle ear. The geometry of the different actuator components is optimized using finite-element modeling.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Deep brain stimulation (DBS) of different nuclei is being evaluated as a treatment for epilepsy. While encouraging results have been reported, the effects of changes in stimulation parameters have been poorly studied. Here the effects of changes of pulse waveform in high frequency DBS (130 Hz) of the amygdala-hippocampal complex (AH) are presented. These effects were studied on interictal epileptic discharge rates (IEDRs). AH-DBS was implemented with biphasic versus pseudo monophasic charge balanced pulses, in two groups of patients: six with temporal lobe epilepsy (TLE) associated with hippocampal sclerosis (HS) and six with non lesional (NLES) temporal epilepsy. In patients with HS, IEDRs were significantly reduced with AH-DBS applied with biphasic pulses in comparison with monophasic pulse. IEDRs were significantly reduced in only two patients with NLES independently to stimulus waveform. Comparison to long-term seizure outcome suggests that IEDRs could be used as a neurophysiological marker of chronic AH-DBS and they suggest that the waveform of the electrical stimuli can play a major role in DBS. We concluded that biphasic stimuli are more efficient than pseudo monophasic pulses in AH-DBS in patients with HS. In patients with NLES epilepsy, other parameters relevant for efficacy of DBS remain to be determined.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Hypnotic depth but not haemodynamic response to painful stimulation can be measured with various EEG-based anaesthesia monitors. We evaluated the variation of pulse plethysmography amplitude induced by an electrical tetanic stimulus (PPG variation) as a potential measure for analgesia and predictor of haemodynamic responsiveness during general anaesthesia. METHODS: Ninety-five patients, ASA I or II, were randomly assigned to five groups [Group 1: bispectral index (BIS) (range) 40-50, effect site remifentanil concentration 1 ng ml(-1);Group 2: BIS 40-50, remifentanil 2 ng ml(-1); Group 3: BIS 40-50, remifentanil 4 ng ml(-1); Group 4: BIS 25-35, remifentanil 2 ng ml(-1); Group 5: BIS 55-65, remifentanil 2 ng ml(-1)]. A 60 mA tetanic stimulus was applied for 5 s on the ulnar nerve. From the digitized pulse oximeter wave recorded on a laptop computer, linear and non-linear parameters of PPG variation during the 60 s period after stimulation were computed. The haemodynamic response to subsequent orotracheal intubation was recorded. The PPG variation was compared between groups and between responders and non-responders to intubation (anova). Variables independently predicting the response were determined by logistic regression. RESULTS: The probability of a response to tracheal intubation was 0.77, 0.47, 0.05, 0.18 and 0.52 in Groups 1-5, respectively (P<0.03). The PPG variability was significantly higher in responders than in non-responders but it did not improve the prediction of the response to tracheal intubation based on BIS level and effect site remifentanil concentration. CONCLUSION: Tetanic stimulation induced PPG variation does not reflect the analgesic state in a wide clinical range of surgical anaesthesia.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION Rhythm disturbances in children with structurally normal hearts are usually associated with abnormalities in cardiac ion channels. The phenotypic expression of these abnormalities ("channelopathies") includes: long and short QT syndromes, Brugada syndrome, congenital sick sinus syndrome, catecholaminergic polymorphic ventricular tachycardia, Lènegre-Lev disease, and/or different degrees of cardiac conduction disease. METHODS The study group consisted of three male patients with sick sinus syndrome, intraventricular conduction disease, and monomorphic sustained ventricular tachycardia. Clinical data and results of electrocardiography, Holter monitoring, electrophysiology, and echocardiography are described. RESULTS In all patients, the ECG during sinus rhythm showed right bundle branch block and long QT intervals. First-degree AV block was documented in two subjects, and J point elevation in one. A pacemaker was implanted in all cases due to symptomatic bradycardia (sick sinus syndrome). Atrial tachyarryhthmias were observed in two patients. The common characteristic ventricular arrhythmia was a monomorphic sustained ventricular tachycardia, inducible with ventricular stimulation and sensitive to lidocaine. In one patient, radiofrequency catheter ablation was successfully performed. No structural abnormalities were found in echocardiography in the study group. CONCLUSION Common clinical and ECG features suggest a common pathophysiology in this group of patients with congenital severe electrical disease.