50 resultados para ELECTROPHORETIC DEPOSITION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A computer simulation study describing the electrophoretic separation and migration of methadone enantiomers in presence of free and immobilized (2-hydroxypropyl)-β-CD is presented. The 1:1 interaction of methadone with the neutral CD was simulated by using experimentally determined mobilities and complexation constants for the complexes in a low-pH BGE comprising phosphoric acid and KOH. The use of complex mobilities represents free solution conditions with the chiral selector being a buffer additive, whereas complex mobilities set to zero provide data that mimic migration and separation with the chiral selector being immobilized, that is CEC conditions in absence of unspecific interaction between analytes and the chiral stationary phase. Simulation data reveal that separations are quicker, electrophoretic displacement rates are reduced, and sensitivity is enhanced in CEC with on-column detection in comparison to free solution conditions. Simulation is used to study electrophoretic analyte behavior at the interface between sample and the CEC column with the chiral selector (analyte stacking) and at the rear end when analytes leave the environment with complexation (analyte destacking). The latter aspect is relevant for off-column analyte detection in CEC and is described here for the first time via the dynamics of migrating analyte zones. Simulation provides insight into means to counteract analyte dilution at the column end via use of a BGE with higher conductivity. Furthermore, the impact of EOF on analyte migration, separation, and detection for configurations with the selector zone being displaced or remaining immobilized under buffer flow is simulated. In all cases, the data reveal that detection should occur within or immediately after the selector zone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A continuous record of atmospheric lead since 12,370 carbon-14 years before the present (14C yr BP) is preserved in a Swiss peat bog. Enhanced fluxes caused by climate changes reached their maxima 10,590 14C yr BP (Younger Dryas) and 823014C yr BP. Soil erosion caused by forest clearing and agricultural tillage increased lead deposition after 532014C yr BP. Increasing lead/scandium and decreasing lead-206/lead-207 beginning 3000 14C yr BP indicate the beginning of lead pollution from mining and smelting, and anthropogenic sources have dominated lead emissions ever since. The greatest lead flux (15.7 milligrams per square meter per year in A.D. 1979) was 1570 times the natural, background value (0.01 milligram per square meter per year from 8030 to 5320 14C yr BP).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

REASONS FOR PERFORMING STUDY: Failure of transfer of passive immunity (FTPI) in foals is associated with a risk of infection and death. The current diagnostic gold standard is quantification of immunoglobulins using radial immunodiffusion (IgG-RID). Routine diagnosis is often performed using semi-quantitative tests. Concentrations of serum electrophoretic gamma globulins (EGG) and total globulins may be useful to assess FTPI, but few studies have investigated their use. OBJECTIVES: To assess agreement between IgG-RID and EGG, and evaluate the accuracy of total globulin concentration to diagnose FTPI based on both IgG-RID and EGG. STUDY DESIGN: Prospective study. METHODS: 360 serum samples were harvested at 6-24 hours post natum from 60 German Warmblood foals. Concentrations of EGG, IgG-RID and total globulin concentration (calculated from total proteins and albumin) were measured. Agreement between EGG and IgG-RID was assessed using Bland-Altman plots and Passing-Bablok regression. The accuracy of total globulin concentration was assessed using rank correlation and ROC curve analysis. RESULTS: Good agreement was found with slightly lower EGG than IgG-RID concentrations (Bland-Altman systemic bias, -1.9 g/L) which was more pronounced at higher concentrations (regression equation: IgG-RID = -0.78 +1.28xEGG). Correlations between total globulin concentration and EGG, and total globulin concentration and IgG-RID were 0.93 and 0.79, respectively. The area under the curve was 0.982 and 0.952 for EGG <4 g/L and <8 g/L, and 0.953 and 0.899 for IgG-RID <4 g/L and <8 g/L. Sensitivities and specificities of total globulin concentration in the diagnosis of FTPI were comparable to commonly used screening tests, but cut-offs could be selected to achieve sensitivities of >95% with 71.2% (IgG-RID) and 90.5% (EGG) specificity for <4 g/L, and >90% with 66.0% (IgG-RID) and 87.9% (EGG) specificity for <8 g/L. CONCLUSIONS: There is good agreement between EGG and IgG-RID, with slightly more conservative estimates of immunoglobulins obtained using EGG. Total globulins may be a useful and economic quantitative screening test with cut-offs achieving high sensitivities, but analyser-specific cut-offs may be necessary. This article is protected by copyright. All rights reserved. KEYWORDS: IgG; electrophoresis; foal; globulins; horse; radial immunodiffusion. This article is protected by copyright. All rights reserved.