109 resultados para Disc prolapse, Disc failure, Disc degeneration, Complex loading, Finite element analysis
Resumo:
PURPOSE We tested the hypothesis that whiplash trauma leads to changes of the signal intensity of cervical discs in T2-weighted images. METHODS AND MATERIALS 50 whiplash patients (18-65 years) were examined within 48h after motor vehicle accident, and again after 3 and 6 months and compared to 50 age- and sex-matched controls. Signal intensity in ROI's of the discs at the levels C2/3 to C7/T1 and the adjacent vertebral bodies were measured on sagittal T2 weighted MR images and normalized using the average of ROI's in fat tissue. The contrast between discs and both adjacent vertebrae was calculated and disc degeneration was graded by the Pfirrmann-grading system. RESULTS Whiplash trauma did not have a significant effect on the normalized signals from discs and vertebrae, on the contrast between discs and adjacent vertebrae, or on the Pfirrmann grading. However, the contrast between discs and adjacent vertebrae and the Pfirrmann grading showed a strong correlation. In healthy volunteers, the contrast between discs and adjacent vertebrae and Pfirrmann grading increased with age and was dependent on the disc level. CONCLUSION We could not find any trauma related changes of cervical disc signal intensities. Normalized signals of discs and Pfirrmann grading changed with age and varied between disc levels with the used MR sequence.
CCL5/RANTES is a key chemoattractant released by degenerative intervertebral discs in organ culture.
Resumo:
Release of chemotactic factors in response to tissue damage has been described for different musculoskeletal tissues, including the intervertebral disc (IVD). This study investigated the chemoattractants that are released by induced degenerative IVDs and may be involved in recruiting mesenchymal stem cells (MSCs). Bovine caudal discs were cultured within a bioreactor and loaded under conditions that mimicked physiological or degenerative settings. Between days 4-6, medium was replaced by PBS, which was subsequently used for proteomic, ELISA and immunoprecipitation analyses of secreted chemokines and cytokines. A Boyden chamber assay was used to observe human MSC migration towards native and chemokine depleted media. Gene expression levels of chemokine receptors in human MSCs were analysed, and CCL5 was localised in bovine and human IVD by immunohistochemistry. Proteomic analysis revealed the presence of CCL5 and CXCL6 within conditioned media. Higher concentrations of CCL5 were found in the degenerative media, and a relationship was found between interleukin-1β and CCL5 concentration. Chemokine immunoprecipitation showed that MSCs had a significantly reduced chemotactic migration towards CCL5-immunoprecipitated and CCL5/CXCL6 co-immunoprecipitated media, whilst CXCL6 depletion did not change MSC chemotaxis. MSCs showed a significant increase in mRNA expression of the CCL5 receptors, CCR1 and CCR4, upon culture in degenerative media. Furthermore, CCL5 was identified in bovine and human disc tissue by immunohistochemistry. Hence, CCL5 may be a key chemoattractant that is produced and released by the intervertebral disc cells. Therefore, these factors could be used to enhance stem/progenitor cell mobilisation in regenerative therapies for early stages of disc degeneration.
Resumo:
Recurrent intervertebral disc (IVD) herniation and degenerative disc disease have been identified as the most important factors contributing to persistent pain and disability after surgical discectomy. An annulus fibrosus (AF) closure device that provides immediate closure of the AF rupture, restores disc height, reduces further disc degeneration and enhances self-repair capacities is an unmet clinical need. In this study, a poly(trimethylene carbonate) (PTMC) scaffold seeded with human bone marrow derived mesenchymal stromal cells (MSCs) and covered with a poly(ester-urethane) (PU) membrane was assessed for AF rupture repair in a bovine organ culture annulotomy model under dynamic load for 14 days. PTMC scaffolds combined with the sutured PU membrane restored disc height of annulotomized discs and prevented herniation of nucleus pulposus (NP) tissue. Implanted MSCs showed an up-regulated gene expression of type V collagen, a potential AF marker, indicating in situ differentiation capability. Furthermore, MSCs delivered within PTMC scaffolds induced an up-regulation of anabolic gene expression and down-regulation of catabolic gene expression in adjacent native disc tissue. In conclusion, the combined biomaterial and cellular approach has the potential to hinder herniation of NP tissue, stabilize disc height, and positively modulate cell phenotype of native disc tissue.
Resumo:
STUDY DESIGN: The biomechanics of vertebral bodies augmented with real distributions of cement were investigated using nonlinear finite element (FE) analysis. OBJECTIVES: To compare stiffness, strength, and stress transfer of augmented versus nonaugmented osteoporotic vertebral bodies under compressive loading. Specifically, to examine how cement distribution, volume, and compliance affect these biomechanical variables. SUMMARY OF BACKGROUND DATA: Previous FE studies suggested that vertebroplasty might alter vertebral stress transfer, leading to adjacent vertebral failure. However, no FE study so far accounted for real cement distributions and bone damage accumulation. METHODS: Twelve vertebral bodies scanned with high-resolution pQCT and tested in compression were augmented with various volumes of cements and scanned again. Nonaugmented and augmented pQCT datasets were converted to FE models, with bone properties modeled with an elastic, plastic and damage constitutive law that was previously calibrated for the nonaugmented models. The cement-bone composite was modeled with a rule of mixture. The nonaugmented and augmented FE models were subjected to compression and their stiffness, strength, and stress map calculated for different cement compliances. RESULTS: Cement distribution dominated the stiffening and strengthening effects of augmentation. Models with cement connecting either the superior or inferior endplate (S/I fillings) were only up to 2 times stiffer than the nonaugmented models with minimal strengthening, whereas those with cement connecting both endplates (S + I fillings) were 1 to 8 times stiffer and 1 to 12 times stronger. Stress increases above and below the cement, which was higher for the S + I cases and was significantly reduced by increasing cement compliance. CONCLUSION: The developed FE approach, which accounts for real cement distributions and bone damage accumulation, provides a refined insight into the mechanics of augmented vertebral bodies. In particular, augmentation with compliant cement bridging both endplates would reduce stress transfer while providing sufficient strengthening.
Resumo:
The aim of this research was to study the impact of loading on partial dentures within the supporting soft tissue with respect to different attachment techniques. A finite element model was developed to calculate the stress and strain distribution in this tissue. The model consisted of the left half of a mandible with three remaining teeth that had suffered an atrophy in the anterior region, and a partial denture over the toothless area that was connected at the left mandibular canine using an attachment system. Resulting stress/strain distributions are presented for different load cases using a commercially available prefabricated attachment system.
Resumo:
RATIONALE The vaporization of Sm, Eu, and Yb tri- and dibromides is accompanied by decomposition and disproportionation reactions. These result in complex vapor compositions whose analysis is an intricate problem for experimentalists. Approaches have been developed to interpret mass spectra and accurately determine the vapor composition of thermally unstable compounds. METHODS A sector type magnet instrument was used. A combined ion source allowed the study of both the molecular and ionic vapor compositions in the electron ionization (EI) and the thermionic emission (TE) modes. The methodological approaches were based on a joint analysis of the ionization efficiency functions, the temperature and time dependences of the ion currents, and special mathematical data evaluation. RESULTS The vaporization of SmBr3, YbBr3, SmBr2, EuBr2, and YbBr2 was studied in the temperature range of 850–1300 K. An initial stage of incongruent vaporization was observed in the case of the tribromides, SmBr2, and YbBr2. This eventually changed to a congruent vaporization stage. Various neutral (Ln, Br, Br2, LnBr, LnBr2, LnBr3, Ln2Br4, Ln2Br5, and Ln2Br6) and charged (Br–, LnBr3–, LnBr4–) species were detected at different vaporization stages. CONCLUSIONS The quantitative vapor composition of Sm, Eu, and Yb tri- and dibromides was determined. It was found that only EuBr2 was stable in the studied temperature range. The developed approaches can be useful in the case of other thermally unstable compounds.
Resumo:
Purpose Femoral fracture is a common medical problem in osteoporotic individuals. Bone mineral density (BMD) is the gold standard measure to evaluate fracture risk in vivo. Quantitative computed tomography (QCT)-based homogenized voxel finite element (hvFE) models have been proved to be more accurate predictors of femoral strength than BMD by adding geometrical and material properties. The aim of this study was to evaluate the ability of hvFE models in predicting femoral stiffness, strength and failure location for a large number of pairs of human femora tested in two different loading scenarios. Methods Thirty-six pairs of femora were scanned with QCT and total proximal BMD and BMC were evaluated. For each pair, one femur was positioned in one-legged stance configuration (STANCE) and the other in a sideways configuration (SIDE). Nonlinear hvFE models were generated from QCT images by reproducing the same loading configurations imposed in the experiments. For experiments and models, the structural properties (stiffness and ultimate load), the failure location and the motion of the femoral head were computed and compared. Results In both configurations, hvFE models predicted both stiffness (R2=0.82 for STANCE and R2=0.74 for SIDE) and femoral ultimate load (R2=0.80 for STANCE and R2=0.85 for SIDE) better than BMD and BMC. Moreover, the models predicted qualitatively well the failure location (66% of cases) and the motion of the femoral head. Conclusions The subject specific QCT-based nonlinear hvFE model cannot only predict femoral apparent mechanical properties better than densitometric measures, but can additionally provide useful qualitative information about failure location.
Resumo:
PURPOSE To compare the initial stability and stability after fatigue of three different locking systems (Synthes(®), Stryker(®) and Medartis(®)) for mandibular fixation and reconstruction. METHOD Standard mandible locking plates with identical profile height (1,5 mm), comparable length and screws with identical diameter (2,0 mm) were used. Plates were fixed with six screws according a preparation protocol. Four point bending tests were then performed using artificial bone material to compare their initial stability and failure limit under realistic loading conditions. Loading of the plates was performed using of a servo hydraulic driven testing machine. The stiffness of the implant/bone construct was calculated using a linear regression on the experimental data included in a range of applied moment between 2 Nm and 6 Nm. RESULTS No statistical difference in the elastic stiffness was visible between the three types of plate. However, differences were observed between the systems concerning the maximal load supported. The Stryker and Synthes systems were able to support a significantly higher moment. CONCLUSION For clinical application all systems show good and reliable results. Practical aspects such as handling, possible angulation of screw fixation, possibility of screw/plate removal, etc. may favour one or the other plating system.
Resumo:
Severe pincer impingement (acetabular protrusio) is an established cause of hip pain and osteoarthritis. The proposed underlying pathomechanism is a dynamic pathological contact of the prominent acetabular rim with the femoral head-neck junction. However, this cannot explain the classically described medial osteoarthritis in these hips. We therefore asked: (1) Does an overload exist in the medial aspect of the protrusio joint? and (2) What is the influence of three contemporary joint-preserving procedures on load distribution in protrusio hips? In vivo force and motion data for walking and standing to sitting were applied to six 3D finite element models (normal, dysplasia, protrusio, acetabular rim trimming, acetabular reorientation, and combined reorientation/rim trimming). Compared with dysplasia, the protrusio joint resulted in opposite patterns of von Mises stress and contact pressure during walking. In protrusio hips, we found an overload at the medial margin of the lunate surface (54% higher than normal). Isolated rim trimming further increased the medial overload (up to 28% higher than protrusio), whereas acetabular reorientation with/without rim trimming reduced stresses by up to 25%. Our results can be used as an adjunct for surgical decision making in the treatment of acetabular protrusio.
Resumo:
The self-regeneration capacity of articular cartilage is limited, due to its avascular and aneural nature. Loaded explants and cell cultures demonstrated that chondrocyte metabolism can be regulated via physiologic loading. However, the explicit ranges of mechanical stimuli that correspond to favourable metabolic response associated with extracellular matrix (ECM) synthesis are elusive. Unsystematic protocols lacking this knowledge produce inconsistent results. This study aims to determine the intrinsic ranges of physical stimuli that increase ECM synthesis and simultaneously inhibit nitric oxide (NO) production in chondrocyte-agarose constructs, by numerically re-evaluating the experiments performed by Tsuang et al. (2008). Twelve loading patterns were simulated with poro-elastic finite element models in ABAQUS. Pressure on solid matrix, von Mises stress, maximum principle stress and pore pressure were selected as intrinsic mechanical stimuli. Their development rates and magnitudes at the steady state of cyclic loading were calculated with MATLAB at the construct level. Concurrent increase in glycosaminoglycan and collagen was observed at 2300 Pa pressure and 40 Pa/s pressure rate. Between 0-1500 Pa and 0-40 Pa/s, NO production was consistently positive with respect to controls, whereas ECM synthesis was negative in the same range. A linear correlation was found between pressure rate and NO production (R = 0.77). Stress states identified in this study are generic and could be used to develop predictive algorithms for matrix production in agarose-chondrocyte constructs of arbitrary shape, size and agarose concentration. They could also be helpful to increase the efficacy of loading protocols for avascular tissue engineering. Copyright (c) 2010 John Wiley \& Sons, Ltd.
Resumo:
Mechanical ventilation is not only a life saving treatment but can also cause negative side effects. One of the main complications is inflammation caused by overstretching of the alveolar tissue. Previously, studies investigated either global strains or looked into which states lead to inflammatory reactions in cell cultures. However, the connection between the global deformation, of a tissue strip or the whole organ, and the strains reaching the single cells lining the alveolar walls is unknown and respective studies are still missing. The main reason for this is most likely the complex, sponge-like alveolar geometry, whose three-dimensional details have been unknown until recently. Utilizing synchrotron-based X-ray tomographic microscopy, we were able to generate real and detailed three-dimensional alveolar geometries on which we have performed finite-element simulations. This allowed us to determine, for the first time, a three-dimensional strain state within the alveolar wall. Briefly, precision-cut lung slices, prepared from isolated rat lungs, were scanned and segmented to provide a three-dimensional geometry. This was then discretized using newly developed tetrahedral elements. The main conclusions of this study are that the local strain in the alveolar wall can reach a multiple of the value of the global strain, for our simulations up to four times as high and that thin structures obviously cause hotspots that are especially at risk of overstretching.
Resumo:
BACKGROUND: It has been shown that different implant designs and different vertical implant positions have an influence on crestal bone levels. The aim of the present study was to evaluate radiographic crestal bone changes around experimental dental implants with non-matching implant-abutment diameters placed submucosally or transmucosally at three different levels relative to the alveolar crest. METHODS: Sixty two-piece dental implants with non-matching implant-abutment diameters were placed in edentulous spaces bilaterally in five foxhounds. The implants were placed submucosally or transmucosally in the left or the right side of the mandible. Within each side, six implants were randomly placed at three distinct levels relative to the alveolar crest. After 12 weeks, 60 crowns were cemented. Radiographs were obtained from all implant sites following implant placement, after crown insertion, and monthly for 6 months after loading. RESULTS: Radiographic analysis revealed very little bone loss and a slight increase in bone level for implants placed at the level of the crest or 1 mm above. The greatest bone loss occurred at implants placed 1 mm below the bone crest. No clinically significant differences regarding marginal bone loss and the level of the bone-to-implant contact were detected between implants with a submucosal or a transmucosal healing. CONCLUSIONS: Implants with non-matching implant-abutment diameters demonstrated some bone loss; however, it was a small amount. There was no clinically significant difference between submucosal and transmucosal approaches.
Resumo:
Purpose: This retrospective study analyzed the pool of patients referred for treatment with dental implants over a 3-year period in a referral specialty clinic. Materials and Methods: All patients receiving dental implants between 2002 and 2004 in the Department of Oral Surgery and Stomatology, University of Bern, were included in this retrospective study. Patients were analyzed according to age, gender, indications for implant therapy, location of implants, and type and length of implants placed. A cumulative logistic regression analysis was performed to identify and analyze potential risk factors for complications or failures. Results: A total of 1,206 patients received 1,817 dental implants. The group comprised 573 men and 633 women with a mean age of 55.2 years. Almost 60% of patients were age 50 or older. The most frequent indication for implant therapy was single-tooth replacement in the maxilla (522 implants or 28.7%). A total of 726 implants (40%) were inserted in the esthetically demanding region of the anterior maxilla. For 939 implants (51.7%), additional bone-augmentation procedures were required. Of these, ridge augmentation with guided bone regeneration was performed more frequently than sinus grafting. Thirteen complications leading to early failures were recorded, resulting in an early failure rate of 0.7%. The regression analysis failed to identify statistically significant failure etiologies for the variables assessed. Conclusions: From this study it can be concluded that patients referred to a specialty clinic for implant placement were more likely to be partially edentulous and over 50 years old. Single-tooth replacement was the most frequent indication (> 50%). Similarly, additional bone augmentation was indicated in more than 50% of cases. Adhering to strict patient selection criteria and a standardized surgical protocol, an early failure rate of 0.7% was experienced in this study population
Resumo:
Due to the inherent limitations of DXA, assessment of the biomechanical properties of vertebral bodies relies increasingly on CT-based finite element (FE) models, but these often use simplistic material behaviour and/or single loading cases. In this study, we applied a novel constitutive law for bone elasticity, plasticity and damage to FE models created from coarsened pQCT images of human vertebrae, and compared vertebral stiffness, strength and damage accumulation for axial compression, anterior flexion and a combination of these two cases. FE axial stiffness and strength correlated with experiments and were linearly related to flexion properties. In all loading modes, damage localised preferentially in the trabecular compartment. Damage for the combined loading was higher than cumulated damage produced by individual compression and flexion. In conclusion, this FE method predicts stiffness and strength of vertebral bodies from CT images with clinical resolution and provides insight into damage accumulation in various loading modes.
Resumo:
INTRODUCTION Light cure of resin-based adhesives is the mainstay of orthodontic bonding. In recent years, alternatives to conventional halogen lights offering reduced curing time and the potential for lower attachment failure rates have emerged. The relative merits of curing lights in current use, including halogen-based lamps, light-emitting diodes (LEDs), and plasma arc lights, have not been analyzed systematically. In this study, we reviewed randomized controlled trials and controlled clinical trials to assess the risks of attachment failure and bonding time in orthodontic patients in whom brackets were cured with halogen lights, LEDs, or plasma arc systems. METHODS Multiple electronic database searches were undertaken, including MEDLINE, EMBASE, and the Cochrane Oral Health Group's Trials Register, CENTRAL. Language restrictions were not applied. Unpublished literature was searched on ClinicalTrials.gov, the National Research Register, Pro-Quest Dissertation Abstracts, and Thesis database. Search terms included randomized controlled trial, controlled clinical trial, random allocation, double blind method, single blind method, orthodontics, LED, halogen, bond, and bracket. Authors of primary studies were contacted as required, and reference lists of the included studies were screened. RESULTS Randomized controlled trials and clinical controlled trials directly comparing conventional halogen lights, LEDs, or plasma arc systems involving patients with full arch, fixed, or bonded orthodontic appliances (not banded) with follow-up periods of a minimum of 6 months were included. Using predefined forms, 2 authors undertook independent extraction of articles; disagreements were resolved by discussion. The assessment of the risk of bias of the randomized controlled trials was based on the Cochrane Risk of Bias tool. Ten studies met the inclusion criteria; 2 were excluded because of high risk of bias. In the comparison of bond failure risk with halogen lights and plasma arc lights, 1851 brackets were included in both groups. Little statistical heterogeneity was observed in this analysis (I(2) = 4.8%; P = 0.379). There was no statistical difference in bond failure risk between the groups (OR, 0.92; 95% CI, 0.68-1.23; prediction intervals, 0.54, 1.56). Similarly, no statistical difference in bond failure risk was observed in the meta-analysis comparing halogen lights and LEDs (OR, 0.96; 95% CI, 0.64-1.44; prediction intervals, 0.07, 13.32). The pooled estimates from both comparisons were OR, 0.93; 95% CI, 0.74-1.17; and prediction intervals, 0.69, 1.17. CONCLUSIONS There is no evidence to support the use of 1 light cure type over another based on risk of attachment failure.