102 resultados para Dentistry, Operative


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This is the sixth and concluding part of a series of publications from the Swiss task force named "Smoking - Intervention in the private dental office" on the topic "tobacco use and dental medicine". The focus of this review is the effects of smoking for the development of atherosclerosis as pathohistological correlate for acute coronary syndrome (ACS), arterial occlusive disease, and cerebrovascular diseases (stroke). Additionally, a causal relationship between tobacco use and an increased rate for complications during pregnancy and child birth will be discussed. Next to causal therapy of local and systemic diseases in general, an emphasis must be given to tobacco use prevention and cessation. Finally, important public health issues concerning smoking and tobacco use will be demonstrated, and options to improve the current situation will be presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This fifth part of a series of publications from the Swiss task force named "Smoking--Intervention in the private dental office" on the topic "tobacco use and dental medicine" focuses on the effects of tobacco use on general health. A significant increase of tobacco use associated morbidity and mortality for many cardiovascular and pulmonary diseases has been well documented in the literature. In this review, the epidemiologic background as well as the pathophysiological fundamentals for tobacco-mediated pulmonary diseases is presented, focusing especially on chronic obstructive pulmonary disease (COPD) and lung cancer. In addition, a causal relationship between nicotine abuse and an increased carcinoma incidence for other malignancies but lung cancer will be discussed. Regarding the evidence in the present literature, it is undisputable that smoking is the most preventable cause for COPD and lung cancer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To determine the clinical performance of a laser fluorescence device (DIAGNOdent pen, KaVo) to discriminate between different occlusal caries depths (D(0)-D(1-4); D(0-2)-D(3,4)) in permanent molars. METHODS: In this prospective, randomized two-centre-study 120 sound/uncavitated carious sites in 120 patients were measured after visual and radiographic caries assessment. In cases of operative intervention (n=86), the lesion depths after caries removal were recorded (reference). In cases of preventive intervention (n=34), the sites were reassessed visually/radiographically after 12 months to verify the status assessed before (reference). The discrimination performance was determined statistically (Mann-Whitney test, Spearman's rho coefficient, and areas under the receiver operating characteristic curves (AUCs)). Sensitivities (SE) and specificities (SP) were plotted as a function of the measured values and cut-off values for the mentioned thresholds suggested. RESULTS: Sound sites (n=13) had significantly minor fluorescence values than carious sites (n=107) (P<0.0001) as had sites with no/enamel caries (n=63) compared to dentinal caries (n=57). The AUCs for the same discriminations were 0.92 and 0.78 (P<0.001). For the D(0)-D(1-4) threshold, a cut-off at a value of 12 (SE: 0.88, SP: 0.85) and for the D(0-2)-D(3,4) threshold at 25 (SE: 0.67, SP: 0.79) can be suggested. A moderate positive correlation between the measurements and the caries depths was calculated (rho=+0.57, P=0.01). CONCLUSION: Within this study, the device's discrimination performance for different caries depths was moderate to very good and it may be recommended as adjunct tool in the diagnosis of occlusal caries.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this study was to estimate intra- and post-operative risk using the American Society of Anaesthesiologists (ASA) classification which is an important predictor of an intervention and of the entire operating programme. STUDY DESIGN: In this retrospective study, 4435 consecutive patients undergoing elective and emergency surgery at the Gynaecological Clinic of the University Hospital of Zurich were included. The ASA classification for pre-operative risk assessment was determined by an anaesthesiologist after a thorough physical examination. We observed several pre-, intra- and post-operative parameters, such as age, body-mass-index, duration of anaesthesia, duration of surgery, blood loss, duration of post-operative stay, complicated post-operative course, morbidity and mortality. The investigation of different risk factors was achieved by a multiple linear regression model for log-transformed duration of hospitalisation. RESULTS: Age and obesity were responsible for a higher ASA classification. ASA grade correlates with the duration of anaesthesia and the duration of the surgery itself. There was a significant difference in blood loss between ASA grades I (113+/-195 ml) and III (222+/-470 ml) and between classes II (176+/-432 ml) and III. The duration of post-operative hospitalisation could also be correlated with ASA class. ASA class I=1.7+/-3.0 days, ASA class II=3.6+/-4.3 days, ASA class III=6.8+/-8.2 days, and ASA class IV=6.2+/-3.9 days. The mean post-operative in-hospital stay was 2.5+/-4.0 days without complications, and 8.7+/-6.7 days with post-operative complications. Multiple linear regression model showed that not only the ASA classification contained an important information for the duration of hospitalisation. Parameters such as age, class of diagnosis, post-operative complications, etc. also have an influence on the duration of hospitalisation. CONCLUSION: This study shows that the ASA classification can be used as a good and early available predictor for the planning of an intervention in gynaecological surgery. The ASA classification helps the surgeon to assess the peri-operative risk profile of which important information can be derived for the planning of the operation programme.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Anatomic reduction and stable fixation by means of tissue- preserving surgical approaches. INDICATIONS Displaced acetabular fractures. Surgical hip dislocation approach with larger displacement of the posterior column in comparison to the anterior column, transtectal fractures, additional intraarticular fragments, marginal impaction. Stoppa approach with larger displacement of the anterior column in comparison to the posterior column. A combined approach might be necessary with difficult reduction. CONTRAINDICATIONS Fractures > 15 days (then ilioinguinal or extended iliofemoral approaches). Suprapubic catheters and abdominal problems (e.g., previous laparotomy due to visceral injuries) with Stoppa approach (then switch to classic ilioinguinal approach). SURGICAL TECHNIQUE: Surgical hip dislocation: lateral decubitus position. Straight lateral incision centered over the greater trochanter. Entering of the Gibson interval. Digastric trochanteric osteotomy with protection of the medial circumflex femoral artery. Opening of the interval between the piriformis and the gluteus minimus muscle. Z-shaped capsulotomy. Dislocation of the femoral head. Reduction and fixation of the posterior column with plate and screws. Fixation of the anterior column with a lag screw in direction of the superior pubic ramus. Stoppa approach: supine position. Incision according to Pfannenstiel. Longitudinal splitting of the anterior portion of the rectus sheet and the rectus abdominis muscle. Blunt dissection of the space of Retzius. Ligation of the corona mortis, if present. Blunt dissection of the quadrilateral plate and the anterior column. Reduction of the anterior column and fixation with a reconstruction plate. Fixation of the posterior column with lag screws. If necessary, the first window of the ilioinguinal approach can be used for reduction and fixation of the posterior column. POSTOPERATIVE MANAGEMENT: During hospital stay, intensive mobilization of the hip joint using a continuous passive motion machine with a maximum flexion of 90 degrees . No active abduction and passive adduction over the body's midline, if a surgical dislocation was performed. Maximum weight bearing 10-15 kg for 8 weeks. Then, first clinical and radiographic follow-up. Deep venous thrombosis prophylaxis for 8 weeks postoperatively. RESULTS: 17 patients with a mean follow-up of 3.2 years. Ten patients were operated via surgical hip dislocation, two patients with a Stoppa approach, and five using a combined or alternative approach. Anatomic reduction was achieved in ten of the twelve patients (83%) without primary total hip arthroplasty. Mean operation time 3.3 h for surgical hip dislocation and 4.2 h for the Stoppa approach. Complications comprised one delayed trochanteric union, one heterotopic ossification, and one loss of reduction. There were no cases of avascular necrosis. In two patients, a total hip arthroplasty was performed due to the development of secondary hip osteoarthritis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To assess the literature on accuracy and clinical performance of computer technology applications in surgical implant dentistry. MATERIALS AND METHODS: Electronic and manual literature searches were conducted to collect information about (1) the accuracy and (2) clinical performance of computer-assisted implant systems. Meta-regression analysis was performed for summarizing the accuracy studies. Failure/complication rates were analyzed using random-effects Poisson regression models to obtain summary estimates of 12-month proportions. RESULTS: Twenty-nine different image guidance systems were included. From 2,827 articles, 13 clinical and 19 accuracy studies were included in this systematic review. The meta-analysis of the accuracy (19 clinical and preclinical studies) revealed a total mean error of 0.74 mm (maximum of 4.5 mm) at the entry point in the bone and 0.85 mm at the apex (maximum of 7.1 mm). For the 5 included clinical studies (total of 506 implants) using computer-assisted implant dentistry, the mean failure rate was 3.36% (0% to 8.45%) after an observation period of at least 12 months. In 4.6% of the treated cases, intraoperative complications were reported; these included limited interocclusal distances to perform guided implant placement, limited primary implant stability, or need for additional grafting procedures. CONCLUSION: Differing levels and quantity of evidence were available for computer-assisted implant placement, revealing high implant survival rates after only 12 months of observation in different indications and a reasonable level of accuracy. However, future long-term clinical data are necessary to identify clinical indications and to justify additional radiation doses, effort, and costs associated with computer-assisted implant surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The aim of this systematic review was to analyze the dental literature regarding accuracy and clinical application in computer-guided template-based implant dentistry. Materials and methods: An electronic literature search complemented by manual searching was performed to gather data on accuracy and surgical, biological and prosthetic complications in connection with computer-guided implant treatment. For the assessment of accuracy meta-regression analysis was performed. Complication rates are descriptively summarized. Results: From 3120 titles after the literature search, eight articles met the inclusion criteria regarding accuracy and 10 regarding the clinical performance. Meta-regression analysis revealed a mean deviation at the entry point of 1.07 mm (95% CI: 0.76-1.22 mm) and at the apex of 1.63 mm (95% CI: 1.26-2 mm). No significant differences between the studies were found regarding method of template production or template support and stabilization. Early surgical complications occurred in 9.1%, early prosthetic complications in 18.8% and late prosthetic complications in 12% of the cases. Implant survival rates of 91-100% after an observation time of 12-60 months are reported in six clinical studies with 537 implants mainly restored immediately after flapless implantation procedures. Conclusion: Computer-guided template-based implant placement showed high implant survival rates ranging from 91% to 100%. However, a considerable number of technique-related perioperative complications were observed. Preclinical and clinical studies indicated a reasonable mean accuracy with relatively high maximum deviations. Future research should be directed to increase the number of clinical studies with longer observation periods and to improve the systems in terms of perioperative handling, accuracy and prosthetic complications.