142 resultados para Creación gold standard


Relevância:

80.00% 80.00%

Publicador:

Resumo:

PRINCIPLES: Coeliac disease (gluten sensitive enteropathy) is a genetically determined disorder with an incidence in the general population that is comparable to type 2 diabetes mellitus. Awareness of this fact and of the often atypical and oligosymptomatic manifestations is only now gaining ground in the medical profession. A high index of suspicion is important in order to minimise diagnostic and therapeutic delay. METHODS: Testing patterns and follow-up for coeliac disease in our institution have been analysed retrospectively for the past five years. The current literature was reviewed with respect to recommendations for clinical practice. RESULTS: A total of 271 patients were tested for coeliac disease over a period of five years. Only in 24 patients were positive results found; after further work-up, the final number of cases with certain or presumed coeliac disease was four. Followup was often difficult, many patients being lost after a single visit. CONCLUSIONS: This study showed that the number of tests ordered in our institution, more often for abdominal than atypical symptoms, has started to increase in the past two years. It also showed that screening tests have found their place in general clinical practice, while the final choice of tests needs to be determined in accordance with available guidelines and local resources. Upper endoscopy with small bowel biopsy remains the gold standard for diagnosis, but its place in follow-up is less certain. Coeliac disease is a disorder for which there is a definite treatment (gluten free diet); if it is left untreated diminished quality of life and potentially serious complications may ensue. Further education of the medical profession regarding coeliac disease, its incidence, presentation and treatment, is clearly indicated..

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In the discussion about the rationale for spine registries, two basic questions have to be answered. The first one deals with the value of orthopaedic registries per se, considering them as observational studies and comparing the evidence they generate with that of randomised controlled trials. The second question asks if the need for registries in spine surgery is similar to that in the arthroplasty sector. The widely held view that randomised controlled trials are the 'gold standard' for evaluation and that observational methods have little or no value ignores the limitations of randomised trials. They may prove unnecessary, inappropriate, impossible, or inadequate. In addition, the external validity and hence the ability to make generalisations about the results of randomised trials is often low. Therefore, the false conflict between those who advocate randomised trials in all situations and those who believe observational data provide sufficient evidence needs to be replaced with mutual recognition of their complementary roles. The fact that many surgical techniques or technologies were introduced into the field of spine surgery without randomised trials or prospective cohort comparisons makes obvious an even increased need for spine registries compared to joint arthroplasty. An essential methodological prerequisite for a registry is a common terminology for reporting results and a sophisticated technology that networks all participants so that one central data pool is created and accessed. Recognising this need, the Spine Society of Europe has researched and developed Spine Tango, the first European spine registry, which can be accessed under www.eurospine.org.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Multislice-computed tomography (MSCT) and magnetic resonance imaging (MRI) are increasingly used for forensic purposes. Based on broad experience in clinical neuroimaging, post-mortem MSCT and MRI were performed in 57 forensic cases with the goal to evaluate the radiological methods concerning their usability for forensic head and brain examination. An experienced clinical radiologist evaluated the imaging data. The results were compared to the autopsy findings that served as the gold standard with regard to common forensic neurotrauma findings such as skull fractures, soft tissue lesions of the scalp, various forms of intracranial hemorrhage or signs of increased brain pressure. The sensitivity of the imaging methods ranged from 100% (e.g., heat-induced alterations, intracranial gas) to zero (e.g., mediobasal impression marks as a sign of increased brain pressure, plaques jaunes). The agreement between MRI and CT was 69%. The radiological methods prevalently failed in the detection of lesions smaller than 3mm of size, whereas they were generally satisfactory concerning the evaluation of intracranial hemorrhage. Due to its advanced 2D and 3D post-processing possibilities, CT in particular possessed certain advantages in comparison with autopsy with regard to forensic reconstruction. MRI showed forensically relevant findings not seen during autopsy in several cases. The partly limited sensitivity of imaging that was observed in this retrospective study was based on several factors: besides general technical limitations it became apparent that clinical radiologists require a sound basic forensic background in order to detect specific signs. Focused teaching sessions will be essential to improve the outcome in future examinations. On the other hand, the autopsy protocols should be further standardized to allow an exact comparison of imaging and autopsy data. In consideration of these facts, MRI and CT have the power to play an important role in future forensic neuropathological examination.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Autogenous iliac crest has long served as the gold standard for anterior lumbar arthrodesis although added morbidity results from the bone graft harvest. Therefore, femoral ring allograft, or cages, have been used to decrease the morbidity of iliac crest bone harvesting. More recently, an experimental study in the animal showed that harvesting local bone from the anterior vertebral body and replacing the void by a radio-opaque beta-tricalcium phosphate plug was a valid concept. However, such a concept precludes theoretically the use of posterior pedicle screw fixation. At one institution a consecutive series of 21 patients underwent single- or multiple-level circumferential lumbar fusion with anterior cages and posterior pedicle screws. All cages were filled with cancellous bone harvested from the adjacent vertebral body, and the vertebral body defect was filled with a beta-tricalcium phosphate plug. The indications for surgery were failed conservative treatment of a lumbar degenerative disc disease or spondylolisthesis. The purpose of this study, therefore, was to report on the surgical technique, operative feasibility, safety, benefits, and drawbacks of this technique with our primary clinical experience. An independent researcher reviewed all data that had been collected prospectively from the onset of the study. The average age of the patients was 39.9 (26-57) years. Bone grafts were successfully harvested from 28 vertebral bodies in all but one patient whose anterior procedure was aborted due to difficulty in freeing the left common iliac vein. This case was converted to a transforaminal interbody fusion (TLIF). There was no major vascular injury. Blood loss of the anterior procedure averaged 250 ml (50-350 ml). One tricalcium phosphate bone plug was broken during its insertion, and one endplate was broken because of wrong surgical technique, which did not affect the final outcome. One patient had a right lumbar plexopathy that was not related to this special technique. There was no retrograde ejaculation, infection or pseudoarthrosis. One patient experienced a deep venous thrombosis. At the last follow up (mean 28 months) all patients had a solid lumbar spine fusion. At the 6-month follow up, the pain as assessed on the visual analog scale (VAS) decreased from 6.9 to 4.5 (33% decrease), and the Oswestry disability index (ODI) reduced from 48.0 to 31.7 with a 34% reduction. However, at 2 years follow up there was a trend for increase in the ODI (35) and VAS (5). The data in this study suggest that harvesting a cylinder of autograft from the adjacent vertebral body is safe and efficient. Filling of the void defect with a beta-tricalcium phosphate plug does not preclude the use of posterior pedicle screw stabilization.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The purpose of the study was to evaluate observer performance in the detection of pneumothorax with cesium iodide and amorphous silicon flat-panel detector radiography (CsI/a-Si FDR) presented as 1K and 3K soft-copy images. Forty patients with and 40 patients without pneumothorax diagnosed on previous and subsequent digital storage phosphor radiography (SPR, gold standard) had follow-up chest radiographs with CsI/a-Si FDR. Four observers confirmed or excluded the diagnosis of pneumothorax according to a five-point scale first on the 1K soft-copy image and then with help of 3K zoom function (1K monitor). Receiver operating characteristic (ROC) analysis was performed for each modality (1K and 3K). The area under the curve (AUC) values for each observer were 0.7815, 0.7779, 0.7946 and 0.7066 with 1K-matrix soft copies and 0.8123, 0.7997, 0.8078 and 0.7522 with 3K zoom. Overall detection of pneumothorax was better with 3K zoom. Differences between the two display methods were not statistically significant in 3 of 4 observers (p-values between 0.13 and 0.44; observer 4: p = 0.02). The detection of pneumothorax with 3K zoom is better than with 1K soft copy but not at a statistically significant level. Differences between both display methods may be subtle. Still, our results indicate that 3K zoom should be employed in clinical practice.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVES: There are no widely accepted criteria for the definition of hematopoietic stem cell transplant -associated microangiopathy (TAM). An International Working Group was formed to develop a consensus formulation of criteria for diagnosing clinically significant TAM. DESIGN AND METHODS: The participants proposed a list of candidate criteria, selected those considered necessary, and ranked those considered optional to identify a core set of criteria. Three obligatory criteria and four optional criteria that ranked highest formed a core set. In an appropriateness panel process, the participants scored the diagnosis of 16 patient profiles as appropriate or not appropriate for TAM. Using the experts' ratings on the patient profiles as a gold standard, the sensitivity and specificity of 24 candidate definitions of the disorder developed from the core set of criteria were evaluated. A nominal group technique was used to facilitate consensus formation. The definition of TAM with the highest score formed the final PROPOSAL. RESULTS: The Working Group proposes that the diagnosis of TAM requires fulfilment of all of the following criteria: (i) >4% schistocytes in blood; (ii) de novo, prolonged or progressive thrombocytopenia (platelet count <50 x 109/L or 50% or greater reduction from previous counts); (iii) sudden and persistent increase in lactate dehydrogenase concentration; (iv) decrease in hemoglobin concentration or increased transfusion requirement; and (v) decrease in serum haptoglobin. The sensitivity and specificity of this definition exceed 80%. INTERPRETATION AND CONCLUSIONS: The Working Group recommends that the presented criteria of TAM be adopted in clinical use, especially in scientific trials.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Soon after its introduction in 1991, MR cholangiopancreatography has become an established diagnostic tool for the evaluation of the pancreaticobiliary ductal system at a field strength of 1.5T. It remains unclear whether MR cholangiopancreatography performed at 3T will benefit from the higher magnetic field strength or whether a field strength of 1.5T should continue to be considered the gold standard for MR cholangiopancreatography. This article reviews the current literature on the benefits and drawbacks of MR cholangiopancreatography at 3T compared with a standard field strength of 1.5T. Field strength-related artifacts that affect MR cholangiopancreatography at 3T also are discussed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Determination of chloride concentration in sweat is the current diagnostic gold standard for Cystic Fibrosis (CF). Nanoduct(R) is a new analyzing system measuring conductivity which requires only 3 microliters of sweat and gives results within 30 minutes. The aim of the study was to evaluate the applicability of this system in a clinical setting of three children's hospitals and borderline results were compared with sweat chloride concentration. Over 3 years, 1,041 subjects were tested and in 946 diagnostic results were obtained. In 95 children, Nanoduct(R) failed (9.1% failure rate), mainly due to failures in preterm babies and newborns. Assuming 59 mmol/L as an upper limit of normal conductivity, all our 46 CF patients were correctly diagnosed (sensitivity 100%, 95% CI: 93.1-100; negative predicted value 100% (95% CI: 99.6-100) and only 39 non CF's were false positive (39/900, 4.3%; specificity 95.7%, 95%CI: 94.2-96.9, positive predicted value 54.1% with a 95%CI: 43.4-65.0). Increasing the diagnostic limit to 80 mmol/L, the rate fell to 0.3% (3/900). CF patients had a median conductivity of 115 mmol/L; the non-CF a median of 37 mmol/L. In conclusion, the Nanoduct(R) test is a reliable diagnostic tool for CF diagnosis: It has a failure rate comparable to other sweat tests and can be used as a simple bedside test for fast and reliable exclusion, diagnosis or suspicion of CF. In cases with borderline conductivity (60-80 mmol/L) other additional methods (determination of chloride and genotyping) are indicated.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Especially in pharmacotherapeutic research, a variety of methods to monitor behavioural and psychological symptoms of dementia (BPSD) are currently being discussed. To date, the most frequently used of these are clinical scales, which, however, are subjective and highly dependent on personnel resources. In our study, we tested the usefulness of actigraphy as a more direct and objective way to measure day-night rhythm disturbances and agitated behaviour.After a baseline assessment, 24 patients with probable dementia of the Alzheimer type (NINCDS-ADRDA) and agitated behaviour received either 3 mg melatonin (n=7), 2.5 mg dronabinol (n=7), or placebo (n=10) for two weeks. In addition, 10 young and 10 elderly healthy subjects were examined as a control group. Motor activity levels were assessed using an actigraph worn continuously on the wrist of the non-dominant hand. At the beginning and the end of the study, patients' Neuropsychiatric Inventory (NPI) scores were also assessed.In the verum group, actigraphic nocturnal activity (P=0.001), NPI total score (P=0.043), and NPI agitation subscale score (P=0.032) showed significant reductions compared to baseline. The treatment-baseline ratio of nocturnal activity (P=0.021) and treatment-baseline difference of the nocturnal portion of 24 h activity (P=0.012) were reduced. Patients' baseline activity levels were similar to those seen in healthy elderly subjects. Younger healthy subjects exhibited higher motor activity even at night. There was no correlation between actigraphy and NPI.Both actigraphic measures and the gold standard clinical scale were able to distinguish between the verum and placebo groups. However, because they did not correlate with each other, they clearly represent different aspects of BPSD, each of which reacts differently to therapy. As a result, actigraphy may well come to play an important role in monitoring treatment success in BPSD.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Stereological tools are the gold standard for accurate (i.e., unbiased) and precise quantification of any microscopic sample. The past decades have provided a broad spectrum of tools to estimate a variety of parameters such as volumes, surfaces, lengths, and numbers. Some of them require pairs of parallel sections that can be produced by either physical or optical sectioning, with optical sectioning being much more efficient when applicable. Unfortunately, transmission electron microscopy could not fully profit from these riches, mainly because of the large depth of field. Hence, optical sectioning was a long-time desire for electron microscopists. This desire was fulfilled with the development of electron tomography that yield stacks of slices from electron microscopic sections. Now, parallel optical slices of a previously unimagined small thickness (2-5 nm axial resolution) can be produced. These optical slices minimize problems related to overprojection effects, and allow for direct stereological analysis, e.g., volume estimation with the Cavalieri principle and number estimation with the optical disector method. Here, we demonstrate that the symbiosis of stereology and electron tomography is an easy and efficient way for quantitative analysis at the electron microscopic level. We call this approach quantitative 3D electron microscopy.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Diabetic nephropathy and end-stage renal failure are still a major cause of mortality amongst patients with diabetes mellitus (DM). In this study, we evaluated the Clinitek-Microalbumin (CM) screening test strip for the detection of microalbuminuria (MA) in a random morning spot urine in comparison with the quantitative assessment of albuminuria in the timed overnight urine collection ("gold standard"). One hundred thirty-four children, adolescents, and young adults with insulin-dependent DM Type 1 were studied at 222 outpatient visits. Because of urinary tract infection and/or haematuria, the data of 13 visits were excluded. Finally, 165 timed overnight urine were collected in the remaining 209 visits (79% sample per visit rate). Ten (6.1%) patients presented MA of > or =15 microg/min. In comparison however, 200 spot urine could be screened (96% sample/visit rate) yielding a significant increase in compliance and screening rate (P<.001, McNemar test). Furthermore, at 156 occasions, the gold standard and CM could be directly compared. The sensitivity and the specificity for CM in the spot urine (cut-off > or =30 mg albumin/l) were 0.89 [95% confidence interval (CI) 0.56-0.99] and 0.73 (CI 0.66-0.80), respectively. The positive and negative predictive value were 0.17 (CI 0.08-0.30) and 0.99 (CI 0.95-1.00), respectively. Considering CM albumin-to-creatinine ratio, the results were poorer than with the albumin concentration alone. Using CM instead of quantitative assessment of albuminuria is not cost-effective (35 US dollars versus 60 US dollars/patient/year). In conclusion, to exclude MA, the CM used in the random spot urine is reliable and easy to handle, but positive screening results of > or =30 mg albumin/l must be confirmed by analyses in the timed overnight collected urine. Although the screening compliance is improved, in terms of analysing random morning spot urine for MA, we cannot recommend CM in a paediatric diabetic outpatient setting because the specificity is far too low.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Theodor Kocher, surgeon and Nobel laureate, has influenced thyroid surgery all over the world: his treatment for multinodular goiter-subtotal thyroidectomy-has been the "Gold Standard" for more than a century. However, based on a new understanding of molecular growth mechanisms in goitrogenesis, we set out to evaluate if a more extended resection yields better results. METHODS: Four thousand three hundred and ninety-four thyroid gland operations with 5,785 "nerves at risk" were prospectively analyzed between 1972 and 2002. From 1972 to 1990, the limited Kocher resections were performed, and from 1991 to 2002 a more radical resection involving at least a hemithyroidectomy was performed. RESULTS: The incidence of postoperative nerve palsy was 3.6%; in the first study period and 0.9%; in the second (P < 0.001, Fisher's exact). Postoperative hypoparathyroidism decreased from 3.2%; in the first period to 0.64%; in the second (P < 0.01). The rate of reoperation for recurrent disease was 11.1%; from 1972 to 1990 and 8.5%; from 1991 to 2002 (P < 0.01). CONCLUSIONS: Extended resection for multinodular goiter not only significantly reduced morbidity, but also decreased the incidence of operations for recurrent disease. Our findings in a large cohort corroborate the suggestions that Kocher's approach should be replaced by a more radical resection, which actually was his original intention more than 130 years ago.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Ultrasound (US) is an emerging imaging technique in interventional pain management. The main advantages are the identification of soft tissues, vessels, and nerves, without exposing patients and personnel to radiation, the possibility to perform continuous imaging, and the visualization of the fluid injected in a real-time fashion. Possible applications are nerve blocks of the cervical and lumbar zygapophysial joints, stellate ganglion block, intercostal nerve blocks, occipital nerve blocks, blocks of the inguinal nerves, peripheral nerve blocks of the extremities, blocks of painful stump neuromas, caudal epidural injections, and injections of tender points. US may also be used for destructive procedures, such as cryoanalgesia, radiofrequency lesions, or chemical neurolysis. The increasing published data available suggest that US has a potential usefulness in interventional pain management, but also limitations. There is still a need for clinical trials investigating efficacy and safety of US-guided pain procedures. Until these studies are made, fluoroscopy or computed tomography remain the gold standard for most interventional pain procedures.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Even though depressions and depressive symptoms are frequently observed in patients with medical diseases, their psychological problems are often neither diagnosed nor treated. Diagnosis of mood state might be easy in isolated cases yet it often is not since the precise nature of normal mood cannot be expressed in quantitative terms. Furthermore, depression can only be diagnosed based on the doctor's clinical appraisal and the patient's own description of his/her complaints. There is no gold standard on which depressive symptoms can be based on--and further on, depression is not a diagnosis. Instead, it is a syndrome that calls for differential diagnoses before treatment can be offered. Diagnosing depressive comorbidity in patients with medical complaints is even more difficult because of the overlap between symptoms of depression and accompanying symptoms of the somatic illness e.g. lack of energy. Although depressive states have been known to be a risk factor for the prognosis of patients with coronary heart disease for a long time, there is a paucity of research about the therapy these patients undergo due to the fact that tricyclic anti-depressants can have cardiotoxic effects on patients with heart disease. The treatment of depression in these patients has become a much lower risk since the introduction of serotonin reuptake inhibitors. There is widespread evidence that depressive comorbidity has a negative impact on the prognosis of medical disorders. Despite the complex nature of diagnosing depression, proper diagnosis and treatment is increasingly important in internal medicine and especially cardiology.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Early detection of bloodstream infections (BSI) is crucial in the clinical setting. Blood culture remains the gold standard for diagnosing BSI. Molecular diagnostic tools can contribute to a more rapid diagnosis in septic patients. Here, a multiplex real-time PCR-based assay for rapid detection of 25 clinically important pathogens directly from whole blood in <6 h is presented. Minimal analytical sensitivity was determined by hit rate analysis from 20 independent experiments. At a concentration of 3 CFU/ml a hit rate of 50% was obtained for E. aerogenes and 100% for S. marcescens, E. coli, P. mirabilis, P. aeruginosa, and A. fumigatus. The hit rate for C. glabrata was 75% at 30 CFU/ml. Comparing PCR identification results with conventional microbiology for 1,548 clinical isolates yielded an overall specificity of 98.8%. The analytical specificity in 102 healthy blood donors was 100%. Although further evaluation is warranted, our assay holds promise for more rapid pathogen identification in clinical sepsis.