51 resultados para Compression Metric


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Until today, most of the documentation of forensic relevant medical findings is limited to traditional 2D photography, 2D conventional radiographs, sketches and verbal description. There are still some limitations of the classic documentation in forensic science especially if a 3D documentation is necessary. The goal of this paper is to demonstrate new 3D real data based geo-metric technology approaches. This paper present approaches to a 3D geo-metric documentation of injuries on the body surface and internal injuries in the living and deceased cases. Using modern imaging methods such as photogrammetry, optical surface and radiological CT/MRI scanning in combination it could be demonstrated that a real, full 3D data based individual documentation of the body surface and internal structures is possible in a non-invasive and non-destructive manner. Using the data merging/fusing and animation possibilities, it is possible to answer reconstructive questions of the dynamic development of patterned injuries (morphologic imprints) and to evaluate the possibility, that they are matchable or linkable to suspected injury-causing instruments. For the first time, to our knowledge, the method of optical and radiological 3D scanning was used to document the forensic relevant injuries of human body in combination with vehicle damages. By this complementary documentation approach, individual forensic real data based analysis and animation were possible linking body injuries to vehicle deformations or damages. These data allow conclusions to be drawn for automobile accident research, optimization of vehicle safety (pedestrian and passenger) and for further development of crash dummies. Real 3D data based documentation opens a new horizon for scientific reconstruction and animation by bringing added value and a real quality improvement in forensic science.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Skeletal diseases such as osteoporosis impose a severe socio-economic burden to ageing societies. Decreasing mechanical competence causes a rise in bone fracture incidence and mortality especially after the age of 65 y. The mechanisms of how bone damage is accumulated under different loading modes and its impact on bone strength are unclear. We hypothesise that damage accumulated in one loading mode increases the fracture risk in another. This study aimed at identifying continuum damage interactions between tensile and compressive loading modes. We propose and identify the material constants of a novel piecewise 1D constitutive model capable of describing the mechanical response of bone in combined tensile and compressive loading histories. We performed several sets of loading–reloading experiments to compute stiffness, plastic strains, and stress-strain curves. For tensile overloading, a stiffness reduction (damage) of 60% at 0.65% accumulated plastic strain was detectable as stiffness reduction of 20% under compression. For compressive overloading, 60% damage at 0.75% plastic strain was detectable as a stiffness reduction of 50% in tension. Plastic strain at ultimate stress was the same in tension and compression. Compression showed softening and tension exponential hardening in the post-yield regime. The hardening behaviour in compression is unaffected by a previous overload in tension but the hardening behaviour in tension is affected by a previous overload in compression as tensile reloading strength is significantly reduced. This paper demonstrates how damage accumulated under one loading mode affects the mechanical behaviour in another loading mode. To explain this and to illustrate a possible implementation we proposed a theoretical model. Including such loading mode dependent damage and plasticity behaviour in finite element models will help to improve fracture risk analysis of whole bones and bone implant structures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Locking compression plates are used in various configurations with lack of detailed information on consequent bone healing. Study design In this in vivo study in sheep 5 different applications of locking compression plate (LCP) were tested using a 45° oblique osteotomy simulating simple fracture pattern. 60 Swiss Alpine sheep where assigned to 5 different groups with 12 sheep each (Group 1: interfragmentary lag screw and an LCP fixed with standard cortex screws as neutralisation plate; Group 2: interfragmentary lag screw and LCP with locking head screws; Group 3: compression plate technique (hybrid construct); Group 4: internal fixator without fracture gap; Group 5: internal fixator with 3 mm gap at the osteotomy site). One half of each group (6 sheep) was monitored for 6 weeks, and the other half (6 sheep) where followed for 12 weeks. Methods X-rays at 3, 6, 9 and 12 weeks were performed to monitor the healing process. After sacrifice operated tibiae were tested biomechanically for nondestructive torsion and compared to the tibia of the healthy opposite side. After testing specimens were processed for microradiography, histology, histomorphometry and assessment of calcium deposition by fluorescence microscopy. Results In all groups bone healing occurred without complications. Stiffness in biomechanical testing showed a tendency for higher values in G2 but results were not statistically significant. Values for G5 were significantly lower after 6 weeks, but after 12 weeks values had improved to comparable results. For all groups, except G3, stiffness values improved between 6 and 12 weeks. Histomorphometrical data demonstrate endosteal callus to be more marked in G2 at 6 weeks. Discussion and conclusion All five configurations resulted in undisturbed bone healing and are considered safe for clinical application.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Asynchronous level crossing sampling analog-to-digital converters (ADCs) are known to be more energy efficient and produce fewer samples than their equidistantly sampling counterparts. However, as the required threshold voltage is lowered, the number of samples and, in turn, the data rate and the energy consumed by the overall system increases. In this paper, we present a cubic Hermitian vector-based technique for online compression of asynchronously sampled electrocardiogram signals. The proposed method is computationally efficient data compression. The algorithm has complexity O(n), thus well suited for asynchronous ADCs. Our algorithm requires no data buffering, maintaining the energy advantage of asynchronous ADCs. The proposed method of compression has a compression ratio of up to 90% with achievable percentage root-mean-square difference ratios as a low as 0.97. The algorithm preserves the superior feature-to-feature timing accuracy of asynchronously sampled signals. These advantages are achieved in a computationally efficient manner since algorithm boundary parameters for the signals are extracted a priori.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Mechanical stress is often associated to interverterbal disc (IVD) degeneration and the effect of mechanical loading on IVD has been studied and reviewed.1,2 Previously, expression of heat shock proteins, HSP70 and HSP27 has been found in pathological discs.3 However, there is no direct evidence on whether IVD cells respond to the mechanical loading by expression of HSPs. The objective of this study is to investigate the stress response of IVD cells during compressive loading in an organ culture. Materials and Methods: Fresh adult bovine caudal discs were cultured with compressive loading applied at physiological range. Effect of loading type (static and dynamic) and repeated loading (2 hours per day for 2 days) were studied. Nucleus pulposus (NP) and annulus fibrosus (AF) of the IVD were retrieved at different time points: right after loading and right after resting. Positive control discs were heat shocked (43°C). Cell activity was assessed and expression of stress response genes (HSP70 and HSF1) and matrix remodeling genes (ACAN, COL2, COL1, ADAMTS4, MMP3 and MMP13) were studied. Results: Cell activity was maintained in all groups. Both NP and AF expressed high level of HSP70 in heat shock groups, confirming their expression in response to stress. In NP, expression of HSP70 was up-regulated after static loading and dynamic loading with higher fold change was observed after static loading. During repeated loading, HSP70 appeared to be upregulated right after loading and decreased after resting. Such trend was not observed in AF and HSF1 levels. Expressions of matrix remodeling genes did not change significantly with loading except ADAMTS4 decreased in AF during static loading. Conclusion: This study demonstrated that NP cells upregulate expression of HSP70 in response to loading induced stress without changing cell activity and matrix remodeling significantly. Acknowledgments: This project was funded by AO Spine (AOSPN) (grant number: SRN_2011_14) and a fellowship exchange award by AO Spine Scientific Research Network (SRN).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

When analysing software metrics, users find that visualisation tools lack support for (1) the detection of patterns within metrics; and (2) enabling analysis of software corpora. In this paper we present Explora, a visualisation tool designed for the simultaneous analysis of multiple metrics of systems in software corpora. Explora incorporates a novel lightweight visualisation technique called PolyGrid that promotes the detection of graphical patterns. We present an example where we analyse the relation of subtype polymorphism with inheritance and invocation in corpora of Smalltalk and Java systems and find that (1) subtype polymorphism is more likely to be found in large hierarchies; (2) as class hierarchies grow horizontally, they also do so vertically; and (3) in polymorphic hierarchies the length of the name of the classes is orthogonal to the cardinality of the call sites.