130 resultados para Breathing-maneuvers


Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the isoflurane-sparing effects of lidocaine administered by constant rate infusion (CRI) during umbilical surgery in calves. STUDY DESIGN: Randomized 'blinded' prospective clinical study. ANIMALS: Thirty calves (mean 4.7 +/- SD 2.5 weeks old) undergoing umbilical surgery. METHODS: After premedication with xylazine (0.1 mg kg(-1) , IM), anaesthesia was induced with ketamine (4 mg kg(-1) , IV) and maintained with isoflurane in O(2) administered through a circle breathing system. The calves were assigned randomly to receive a bolus of 2 mg kg(-1) lidocaine IV after induction of anaesthesia, followed by CRI of 50 mug kg(-1) minute(-1) (group L, n=15) or a bolus and CRI of 0.9% sodium chloride (NaCl, group S, n=15). End-tidal isoflurane was adjusted to achieve adequate depth of anaesthesia. Heart rate, direct arterial blood pressure and body temperature were measured intraoperatively. Groups were compared by t- tests, anova or Mann-Whitney rank sum test as appropriate. RESULTS: The end-tidal concentration of isoflurane (median, IQR) was significantly lower in group L [1.0% (0.94-1.1)] compared to group S [1.2% (1.1-1.5)], indicating a 16.7% reduction in anaesthetic requirement during lidocaine CRI. Cardiopulmonary parameters and recovery times did not differ significantly between groups. CONCLUSION AND CLINICAL RELEVANCE: Lidocaine CRI may be used as a supplement to inhalation anaesthesia during umbilical surgery in calves in countries where such a protocol would be within the legal requirements for veterinary use in food animals. This study did not show any measurable benefit to the calves other than a reduction in isoflurane requirement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

REASONS FOR PERFORMING STUDY: Efficacy of medications for recurrent airway obstruction is typically tested using clinical, cytological and lung function examinations of severely affected animals. These trials are technically challenging and may not adequately reflect the spectrum of disease and owner complaints encountered in clinical practice. OBJECTIVE: To determine if owners of horses with chronic airway disease are better able to detect drug efficacy than a veterinarian who clinically examines horses infrequently. METHOD: In a double-blinded randomised controlled trial, owners and a veterinarian compared the efficacy of dexamethasone (0.1 mg/kg bwt per os, q. 24 h, for 3 weeks; n = 9) to placebo (n = 8) in horses with chronic airway disease. Before and after treatment, owners scored performance, breathing effort, coughing and nasal discharge using a visual analogue scale (VAS). The clinician recorded vital parameters, respiratory distress, auscultation findings, cough and nasal discharge, airway mucus score, bronchoalveolar lavage fluid (BALF) cytology and arterial blood gases. RESULTS: The VAS score improved significantly in dexamethasone- but not placebo-treated horses. In contrast, the clinician failed to differentiate between dexamethasone- and placebo-treated animals based on clinical observations, BALF cytology or endoscopic mucus score. Respiratory rate (RR) and arterial oxygen pressure (PaO(2)) improved with dexamethasone but not placebo. CONCLUSIONS AND CLINICAL RELEVANCE: In the design of clinical trials of airway disease treatments, more emphasis should be placed on owner-assessed VAS than on clinical, cytological and endoscopic observations made during brief examinations by a veterinarian. Quantifiable indicators reflecting lung function such as RR and PaO(2) provide a good assessment of drug efficacy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To describe clinical respiratory parameters in cats and dogs with respiratory distress and identify associations between respiratory signs at presentation and localization of the disease with particular evaluation between the synchrony of abdominal and chest wall movements as a clinical indicators for pleural space disease. Design - Prospective observational clinical study. SETTING: Emergency service in a university veterinary teaching hospital. ANIMALS: Cats and dogs with respiratory distress presented to the emergency service between April 2008 and July 2009. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: The following parameters were systematically determined at time of admission: respiratory rate, heart rate, temperature, type of breathing, movement of the thoracic and abdominal wall during inspiration, presence of stridor, presence and type of dyspnea, and results of thoracic auscultation. Abdominal and chest wall movement was categorized as synchronous, asynchronous, or inverse. Diagnostic test results, diagnosis, and outcome were subsequently recorded. Based on the final diagnoses, animals were assigned to 1 or more of the following groups regarding the anatomical localization of the respiratory distress: upper airways, lower airways, lung parenchyma, pleural space, thoracic wall, nonrespiratory causes, and normal animals. One hundred and seventy-six animals (103 cats and 73 dogs) were evaluated. Inspiratory dyspnea was associated with upper airway disease in dogs and expiratory dyspnea with lower airway disease in cats. Respiratory noises were significantly associated and highly sensitive and specific for upper airway disease. An asynchronous or inverse breathing pattern and decreased lung auscultation results were significantly associated with pleural space disease in both dogs and cats (P<0.001). The combination is highly sensitive (99%) but not very specific (45%). Fast and shallow breathing was not associated with pleural space disease. Increased or moist pulmonary auscultation findings were associated with parenchymal lung disease. CONCLUSIONS: Cats and dogs with pleural space disease can be identified by an asynchronous or inverse breathing pattern in combination with decreased lung sounds on auscultation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In an effort to understand the fate of inhaled submicron particles in the small sacs, or alveoli, comprising the gas-exchange region of the lung, we calculated the flow in three-dimensional (3D) rhythmically expanding models of alveolated ducts. Since convection toward the alveolar walls is a precursor to particle deposition, it was the goal of this paper to investigate the streamline maps' dependence upon alveoli location along the acinar tree. On the alveolar midplane, the recirculating flow pattern exhibited closed streamlines with a stagnation saddle point. Off the midplane we found no closed streamlines but nested, funnel-like, spiral, structures (reminiscent of Russian nesting dolls) that were directed towards the expanding walls in inspiration, and away from the contracting walls in expiration. These nested, funnel-like, structures were surrounded by air that flowed into the cavity from the central channel over inspiration and flowed from the cavity to the central channel over expiration. We also found that fluid particle tracks exhibited similar nested funnel-like spiral structures. We conclude that these unique alveolar flow structures may be of importance in enhancing deposition. In addition, due to inertia, the nested, funnel-like, structures change shape and position slightly during a breathing cycle, resulting in flow mixing. Also, each inspiration feeds a fresh supply of particle-laden air from the central channel to the region surrounding the mixing region. Thus, this combination of flow mixer and flow feeder makes each individual alveolus an effective mixing unit, which is likely to play an important role in determining the overall efficiency of convective mixing in the acinus.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

REASONS FOR PERFORMING STUDY: The horse owner assessed respiratory signs index (HOARSI-1-4, healthy, mildly, moderately and severely affected, respectively) is based on owner-reported clinical history and has been used for the investigation of recurrent airway obstruction (RAO) genetics utilising large sample sizes. Reliable phenotype identification is of paramount importance in genetic studies. Owner reports of respiratory signs have shown good repeatability, but the agreement of HOARSI with an in-depth examination of the lower respiratory tract has not been investigated. OBJECTIVES: To determine the correlation of HOARSI grades 3/4 with the characteristics of RAO and of HOARSI-2 with the characteristics of inflammatory airway disease. Further, to test whether there are phenotypic differences in the manifestation of lung disease between families. METHODS: Seventy-one direct offspring of 2 RAO-affected Warmblood stallions (33 from the first family, 38 from the second) were graded as HOARSI-1-4 and underwent a clinical examination of the respiratory system, arterial blood gas analysis, endoscopic mucus scoring, cytology of tracheobronchial secretion (TBS) and bronchoalveolar lavage fluid (BALF), and clinical assessment of airway reactivity to methacholine chloride. RESULTS: HOARSI-3/4 animals in clinical exacerbation showed signs consistent with RAO: coughing, nasal discharge, abnormal lung sounds and breathing pattern as well as increased numbers of neutrophils in TBS and BALF, excessive mucus accumulation and airway hyper-responsiveness to methacholine. HOARSI-3/4 horses in remission only had increased amounts of tracheal mucus and TBS neutrophil percentages. Clinical phenotypes were not significantly different between the 2 families. CONCLUSIONS AND CLINICAL RELEVANCE: HOARSI reliably identifies RAO-affected horses in our population.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to test the hypothesis that ear oximetry immediately after the release of a sustained Valsalva maneuver accurately detects patent foramen ovale (PFO). One hundred sixty-five scuba divers underwent transesophageal echocardiography (TEE; reference method) for PFO assessment. Ear oximetry of the right earlobe was performed in a different room within a time frame of 2 hours before or after TEE. The subject and the oximetry operator were unaware of the results of TEE. Oxygen saturation (SO(2)) measurements were obtained at baseline and during the release phase of 4 Valsalva maneuvers within 10 minutes, and the average SO(2) change (SO(2) at baseline minus SO(2) at Valsalva release) was determined as the primary study end point. One hundred seventeen divers had no PFO, and 48 (29%) had PFO by TEE (mean age 39 ± 8 years). The average SO(2) change was 0.79 ± 1.13% (i.e., a slight absolute SO(2) decrease in response to the Valsalva maneuver) in the group without PFO and 1.67 ± 1.19% in the PFO group (p <0.0001). Using receiver-operating characteristic curve analysis, a PFO as defined by TEE could be detected at a threshold of a Valsalva-induced decrease in SO(2) of ≥0.825 percentage points in comparison to baseline (sensitivity 0.756, specificity 0.706, area under the receiver-operating characteristic curve 0.763, p <0.0001, negative predictive value 0.882). In conclusion, the entirely noninvasive method of ear oximetry in response to repetitive Valsalva maneuvers is accurate and useful as a screening method for the detection of a PFO, as shown in this study of divers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim was to investigate the effect of different speech tasks, i.e. recitation of prose (PR), alliteration (AR) and hexameter (HR) verses and a control task (mental arithmetic (MA) with voicing of the result on end-tidal CO2 (PETCO2), cerebral hemodynamics and oxygenation. CO2 levels in the blood are known to strongly affect cerebral blood flow. Speech changes breathing pattern and may affect CO2 levels. Measurements were performed on 24 healthy adult volunteers during the performance of the 4 tasks. Tissue oxygen saturation (StO2) and absolute concentrations of oxyhemoglobin ([O2Hb]), deoxyhemoglobin ([HHb]) and total hemoglobin ([tHb]) were measured by functional near-infrared spectroscopy (fNIRS) and PETCO2 by a gas analyzer. Statistical analysis was applied to the difference between baseline before the task, 2 recitation and 5 baseline periods after the task. The 2 brain hemispheres and 4 tasks were tested separately. A significant decrease in PETCO2 was found during all 4 tasks with the smallest decrease during the MA task. During the recitation tasks (PR, AR and HR) a statistically significant (p < 0.05) decrease occurred for StO2 during PR and AR in the right prefrontal cortex (PFC) and during AR and HR in the left PFC. [O2Hb] decreased significantly during PR, AR and HR in both hemispheres. [HHb] increased significantly during the AR task in the right PFC. [tHb] decreased significantly during HR in the right PFC and during PR, AR and HR in the left PFC. During the MA task, StO2 increased and [HHb] decreased significantly during the MA task. We conclude that changes in breathing (hyperventilation) during the tasks led to lower CO2 pressure in the blood (hypocapnia), predominantly responsible for the measured changes in cerebral hemodynamics and oxygenation. In conclusion, our findings demonstrate that PETCO2 should be monitored during functional brain studies investigating speech using neuroimaging modalities, such as fNIRS, fMRI to ensure a correct interpretation of changes in hemodynamics and oxygenation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article is aimed at addressing the current state-of-the-art in epidemiology, pathophysiology, diagnostic procedures and treatment options for appropriate management of obstructive sleep apnoea (OSA) in cardiovascular (in particular hypertensive) patients, as well as for the management of cardiovascular diseases (in particular arterial hypertension) in OSA patients. The present document is the result of work performed by a panel of experts participating in the European Union COST (Cooperation in Scientific and Technological research) Action B26 on OSA, with the endorsement of the European Respiratory Society and the European Society of Hypertension. In particular, these recommendations are aimed at reminding cardiovascular experts to consider the occurrence of sleep-related breathing disorders in patients with high blood pressure. They are also aimed at reminding respiration experts to consider the occurrence of hypertension in patients with respiratory problems at night.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background For reliable assessment of ventilation inhomogeneity, multiple-breath washout (MBW) systems should be realistically validated. We describe a new lung model for in vitro validation under physiological conditions and the assessment of a new nitrogen (N2)MBW system. Methods The N2MBW setup indirectly measures the N2 fraction (FN2) from main-stream carbon dioxide (CO2) and side-stream oxygen (O2) signals: FN2 = 1−FO2−FCO2−FArgon. For in vitro N2MBW, a double chamber plastic lung model was filled with water, heated to 37°C, and ventilated at various lung volumes, respiratory rates, and FCO2. In vivo N2MBW was undertaken in triplets on two occasions in 30 healthy adults. Primary N2MBW outcome was functional residual capacity (FRC). We assessed in vitro error (√[difference]2) between measured and model FRC (100–4174 mL), and error between tests of in vivo FRC, lung clearance index (LCI), and normalized phase III slope indices (Sacin and Scond). Results The model generated 145 FRCs under BTPS conditions and various breathing patterns. Mean (SD) error was 2.3 (1.7)%. In 500 to 4174 mL FRCs, 121 (98%) of FRCs were within 5%. In 100 to 400 mL FRCs, the error was better than 7%. In vivo FRC error between tests was 10.1 (8.2)%. LCI was the most reproducible ventilation inhomogeneity index. Conclusion The lung model generates lung volumes under the conditions encountered during clinical MBW testing and enables realistic validation of MBW systems. The new N2MBW system reliably measures lung volumes and delivers reproducible LCI values.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abstract Background: Aerosol therapy in preterm infants is challenging, as a very small proportion of the drug deposits in the lungs. Aim: Our aim was to compare efficiency of standard devices with newer, more efficient aerosol delivery devices. Methods: Using salbutamol as a drug marker, we studied two prototypes of the investigational eFlow(®) nebulizer for babies (PARI Pharma GmbH), a jet nebulizer (Intersurgical(®) Cirrus(®)), and a pressurized metered dose inhaler (pMDI; GSK) with a detergent-coated holding chamber (AeroChamber(®) MV) in the premature infant nose throat-model (PrINT-model) of a 32-week preterm infant (1,750 g). A filter or an impactor was placed below the infant model's "trachea" to capture the drug dose or particle size, respectively, that would have been deposited in the lung. Results: Lung dose (percentage of nominal dose) was 1.5%, 6.8%, and 18.0-20.6% for the jet nebulizer, pMDI-holding chamber, and investigational eFlow nebulizers, respectively (p<0.001). Jet nebulizer residue was 69.4% and 10.7-13.9% for the investigational eFlow nebulizers (p<0.001). Adding an elbow extension between the eFlow and the model significantly lowered lung dose (p<0.001). A breathing pattern with lower tidal volume decreased deposition in the PrINT-model and device residue (p<0.05), but did not decrease lung dose. Conclusions: In a model for infant aerosol inhalation, we confirmed low lung dose using jet nebulizers and pMDI-holding chambers, whereas newer, more specialized vibrating membrane devices, designed specifically for use in preterm infants, deliver up to 20 times more drug to the infant's lung.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Anaesthesia causes a respiratory impairment, whether the patient is breathing spontaneously or is ventilated mechanically. This impairment impedes the matching of alveolar ventilation and perfusion and thus the oxygenation of arterial blood. A triggering factor is loss of muscle tone that causes a fall in the resting lung volume, functional residual capacity. This fall promotes airway closure and gas adsorption, leading eventually to alveolar collapse, that is, atelectasis. The higher the oxygen concentration, the faster will the gas be adsorbed and the aleveoli collapse. Preoxygenation is a major cause of atelectasis and continuing use of high oxygen concentration maintains or increases the lung collapse, that typically is 10% or more of the lung tissue. It can exceed 25% to 40%. Perfusion of the atelectasis causes shunt and cyclic airway closure causes regions with low ventilation/perfusion ratios, that add to impaired oxygenation. Ventilation with positive end-expiratory pressure reduces the atelectasis but oxygenation need not improve, because of shift of blood flow down the lung to any remaining atelectatic tissue. Inflation of the lung to an airway pressure of 40 cmH2O recruits almost all collapsed lung and the lung remains open if ventilation is with moderate oxygen concentration (< 40%) but recollapses within a few minutes if ventilation is with 100% oxygen. Severe obesity increases the lung collapse and obstructive lung disease and one-lung anesthesia increase the mismatch of ventilation and perfusion. CO2 pneumoperitoneum increases atelectasis formation but not shunt, likely explained by enhanced hypoxic pulmonary vasoconstriction by CO2. Atelectasis may persist in the postoperative period and contribute to pneumonia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Patients late after open-heart surgery may develop dual-loop reentrant atrial arrhythmias, and mapping and catheter ablation remain challenging despite computer-assisted mapping techniques. Objectives The purpose of the study was to demonstrate the prevalence and characteristics of dual-loop reentrant arrhythmias, and to define the optimal mapping and ablation strategy. Methods Fourty consecutive patients (mean age 52+/-12 years) with intra-atrial reentrant tachycardia (IART) after open-heart surgery (with an incision of the right atrial free wall) were studied. Dual-loop IART was defined as the presence of two simultaneous atrial circuits. Following an abrupt tachycardia change during radiofrequency (RF) ablation, electrical disconnection of the targeted reentry isthmus from the remaining circuit was demonstrated by entrainment mapping. Furthermore, the second circuit loop was localized using electroanatomic mapping and/or entrainment mapping. Results Dual-loop IART was demonstrated in 8 patients (20%, 5 patients with congenital heart disease, 3 with acquired heart disease). Dual-loop IART included an isthmus-dependant atrial flutter combined with a reentry related to the atriotomy scar. The diagnosis of dual-loop IART required the comparison of entrainment mapping before and after tachycardiamodification. Overall, 35 patients had successful RF ablation (88%). Success rates were lower in patients with dual-loop IART than in patient without dual-loop IART. Ablation failures in 3 patients with dual-loop IART were related to the inability to properly transect the second tachycardia isthmus in the right atrial free wall. Conclusions Dual-loop IART is relatively common after heart surgery involving a right atriotomy. Abrupt tachycardia change and specific entrainment mapping maneuvers demonstrate these circuits. Electroanatomic mapping appears to be important to assist catheter ablation of periatriotomy circuits.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A modified uvulopalatopharyngoplasty (UPPP) was carried out between January 1992 and December 2003 at the ENT Department of the Inselspital in Bern in 146 patients with habitual or complicated rhonchopathy. The operation consisted of a classical tonsillectomy or residual tonsil resection and additional shortening of the uvula. The natural mucosal fold between the uvula and the upper pole of the tonsils was carefully preserved. A wide opening to the rhinopharynx was created by asymmetric suturing of the glossopalantine and pharyngopalatine arches. A retrospective questionnaire with regard to rhonchopathy, phases of apnea, daytime drowsiness, obstruction of nasal breathing, long-term complications and patient satisfaction was used to evaluate the short-term and long-term effectiveness of the modified UPPP as well as the incidence of adverse side effects. Complete postoperative courses were evaluated in 116 patients. Surgical complications were restricted to one case with postoperative hemorrhage. A velum insufficiency or postoperative rhinopharyngeal stenosis did not occur. Eighty-three patients (72%) confirmed a persistent suppression or substantial improvement of the rhonchopathy. Disappearance or decrease of sleep apnea was confirmed in 12 (63%) out of 19 postoperative polysomnographic follow-up investigations. Long-term complications occurred in a total of 27 (23%) of 116 patients. They were confined to minor problems such as dryness of the mouth (n = 12), slight difficulty in swallowing (n = 7), discrete speech disturbances (n = 1), and slight pharyngeal dysesthesias (n = 7) with feeling of a lump in the throat and compulsive clearing of the throat. Eighty-five patients (73%) reported that they were satisfied with the postoperative result even several years after the operation. Looking back, 31 patients (27%) would no longer have the operation performed. The inadequate result of the rhonchopathy was specified as the reason by 21 patients. Ten patients had unpleasant memories of the operation because of intensive postoperative pain. Snoring and apneic phases are suppressed or improved by non-traumatic UPPP in the majority of patients. This effect persisted even years after the operation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

CONCLUSION: Endoscopic resection of laryngeal and tracheal lesions using the microdebrider is a safe, accurate and reliable method. OBJECTIVE: The microdebrider is an important tool for endoscopic nasal and sinus surgery and over the last few years a powered blade with a long shaft has been developed for endoscopic laryngeal and tracheal surgery. The aim of this non-randomized prospective study was to determine the advantages and disadvantages of the microdebrider for treating patients with different laryngeal and tracheal pathologies. MATERIAL AND METHODS: The laryngeal microdebrider was used under endoscopic control in 37 patients. In 29 cases a benign laryngeal lesion was removed endoscopically. In four patients debulking of a malignant obstructive endolaryngeal tumor was performed in order to avoid a tracheotomy. In four cases a bulky obstructing endotracheal lesion was removed. RESULTS: All laryngotracheal lesions could be removed, and this was facilitated by the use of angled rigid telescopes and the laryngeal blade. No traumatic lesions to normal laryngeal tissue occurred as a result of use of the microdebrider and no postoperative endolaryngeal bleeding was observed. The histological diagnosis of the biopsies taken with the microdebrider was accurate in every case. In three of the four cases with obstructive laryngeal malignancies, a tracheotomy was avoided until definitive therapy was undertaken. Normal breathing was restored in all patients with endotracheal lesions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A prothrombotic state may contribute to the elevated cardiovascular risk in patients with obstructive sleep apnea (OSA). We investigated the relationship between apnea severity and hemostasis factors and effect of continuous positive airway pressure (CPAP) treatment on hemostatic activity. We performed full overnight polysomnography in 44 OSA patients (mean age 47+/-10 years), yielding apnea-hypopnea index (AHI) and mean nighttime oxyhemoglobin saturation (SpO2) as indices of apnea severity. For treatment, subjects were double-blind randomized to 2 weeks of either therapeutic CPAP (n = 18), 3 l/min supplemental nocturnal oxygen (n = 16) or placebo-CPAP (<1 cm H2O) (n = 10). Levels of von Willebrand factor antigen (VWF:Ag), soluble tissue factor (sTF), D-dimer, and plasminogen activator inhibitor (PAI)-1 antigen were measured in plasma pre- and posttreatment. Before treatment, PAI-1 was significantly correlated with AHI (r = 0.47, p = 0.001) and mean nighttime SpO2 (r = -0.32, p = 0.035), but these OSA measures were not significantly related with VWF:Ag, sTF, and D-dimer. AHI was a significant predictor of PAI-1 (R2 = 0.219, standardized beta = 0.47, p = 0.001), independent of mean nighttime SpO2, body mass index (BMI), and age. A weak time-by-treatment interaction for PAI-1 was observed (p = 0.041), even after adjusting for age, BMI, pre-treatment AHI, and mean SpO2 (p = 0.046). Post hoc analyses suggested that only CPAP treatment was associated with a decrease in PAI-1 (p = 0.039); there were no changes in VWF:Ag, sTF, and D-dimer associated with treatment with placebo-CPAP or with nocturnal oxygen. Apnea severity may be associated with impairment in the fibrinolytic capacity. To the extent that our sample size was limited, the observation that CPAP treatment led to a decrease in PAI-1 in OSA must be regarded as tentative.