127 resultados para Aesthetic rehabilitation
Resumo:
OBJECTIVES: To compare the clinical outcomes of standard, cylindrical, screw-shaped to novel tapered, transmucosal (Straumann Dental implants immediately placed into extraction sockets. Material and methods: In this randomized-controlled clinical trial, outcomes were evaluated over a 3-year observation period. This report deals with the need for bone augmentation, healing events, implant stability and patient-centred outcomes up to 3 months only. Nine centres contributed a total of 208 immediate implant placements. All surgical and post-surgical procedures and the evaluation parameters were discussed with representatives of all centres during a calibration meeting. Following careful luxation of the designated tooth, allocation of the devices was randomly performed by a central study registrar. The allocated SLA titanium implant was installed at the bottom or in the palatal wall of the extraction socket until primary stability was reached. If the extraction socket was >or=1 mm larger than the implant, guided bone regeneration was performed simultaneously (Bio Oss and BioGide. The flaps were then sutured. During non-submerged transmucosal healing, everything was done to prevent infection. At surgery, the need for augmentation and the degree of wound closure was verified. Implant stability was assessed clinically and by means of resonance frequency analysis (RFA) at surgery and after 3 months. Wound healing was evaluated after 1, 2, 6 and 12 weeks post-operatively. RESULTS: The demographic data did not show any differences between the patients receiving either standard cylindrical or tapered implants. All implants yielded uneventful healing with 15% wound dehiscences after 1 week. After 2 weeks, 93%, after 6 weeks 96%, and after 12 weeks 100% of the flaps were closed. Ninety percent of both implant designs required bone augmentation. Immediately after implantation, RFA values were 55.8 and 56.7 and at 3 months 59.4 and 61.1 for cylindrical and tapered implants, respectively. Patient-centred outcomes did not differ between the two implant designs. However, a clear preference of the surgeon's perception for the appropriateness of the novel-tapered implant was evident. CONCLUSIONS: This RCT has demonstrated that tapered or standard cylindrical implants yielded clinically equivalent short-term outcomes after immediate implant placement into the extraction socket.
Resumo:
PURPOSE: The surgical treatment of oral cancer results in functional and aesthetical impairments. Patients' quality of life is considerably impaired by oral symptoms resulting from therapy of oral cancer. In many cases the inevitable resection of the tumor, as well as the adjuvant radiochemotherapy will cause the destruction of physiologically and anatomically important structures. One focus of research was the specific rehabilitation of dental loss by functional dentures. Another was the course of 19 impairments (comprehension of speech for unknown others, comprehension of speech for familiar others, eating/swallowing, mobility of the tongue, opening range of the mouth, mobility of lower jaw, mobility of neck, mobility of arms and shoulders, sense of taste, sense of smell, appearance, strength, appetite, respiration, pain, swelling, xerostomia, halitosis). METHODS: Commissioned by the German, Austrian and Swiss cooperative group on tumors of the maxillofacial region (DOSAK), data were collected in 3.894 questionnaires at 43 hospitals in Germany, Austria and Switzerland. The catalogue comprised 147 items in 9 chapters. At the end of the enquiry, 1.761 anonymous questionnaires were returned by 38 hospitals. 1.652 of these could be evaluated regarding the question. RESULTS: The sum score of the 19 impairments was highly increased immediately after the operation and recovered over the next 6 months, without, however, reaching the pre-surgery level. Of 1.652 patients, only 35% did not lose any teeth during therapy. 23% lost up to 5, 17% up to 10 teeth. A quarter of the patients lost more than 10 teeth. The more teeth were lost, the greater the decline of quality of life (p < or = 0.001), although this could be allayed by the functionality of the dentures (p < or = 0.001). There is a reciprocal dependence between the functionality of dental prosthetics and impairment by eating/swallowing (p < or = 0.001). CONCLUSIONS: Patients' quality of life after radical surgery of a carcinoma of the oral cavity depends not only on the functionality of dentures and the specificity of rehabilitation, but also from the initial findings, the extent and location of the resection, the chosen therapy, the general circumstances of the patient's life as well as their strategies of coping. These factors, however, unlike those of functionality of dental prosthesis and rehabilitation, are not modifiable.
Resumo:
The longitudinal dimension of schizophrenia and related severe mental illness is a key component of theoretical models of recovery. However, empirical longitudinal investigations have been underrepresented in the psychopathology of schizophrenia. Similarly, traditional approaches to longitudinal analysis of psychopathological data have had serious limitations. The utilization of modern longitudinal methods is necessary to capture the complexity of biopsychosocial models of treatment and recovery in schizophrenia. The present paper summarizes empirical data from traditional longitudinal research investigating recovery in symptoms, neurocognition, and social functioning. Studies conducted under treatment as usual conditions are compared to psychosocial intervention studies and potential treatment mechanisms of psychosocial interventions are discussed. Investigations of rehabilitation for schizophrenia using the longitudinal analytic strategies of growth curve and time series analysis are demonstrated. The respective advantages and disadvantages of these modern methods are highlighted. Their potential use for future research of treatment effects and recovery in schizophrenia is also discussed.
Resumo:
To evaluate the effects of a comprehensive outpatient rehabilitation program in chronic heart failure (CHF) on quality of life (QoL) in relation to emotional status and clinical severity of disease.
Resumo:
This evaluation was performed to assess the effects of a new, comprehensive outpatient rehabilitation program on generic and disease-specific quality of life related to exercise tolerance in stable chronic heart failure patients. Fifty-one patients (aged 59+/-11 years; 84% men) were treated for 12 weeks. Patients underwent optimized drug treatment, exercise training, and counseling and education. At baseline and at the end of the program, functional status, exercise capacity, and quality of life were assessed using the Medical Outcomes Study 36-item Short-Form Health Survey and the Minnesota Living with Heart Failure Questionnaire. Left ventricular ejection fraction and New York Heart Association functional class, as well as measures of physical fitness and walking distance covered in 6 minutes, improved significantly (by 11%-20% and by 58% on average, respectively). Physical functioning (effect size, 0.38; p<0.0001), role functioning (effect size, 0.17; p<0.05), and mental component score (effect size, 0.47; p<0.0001) on the questionnaire improved significantly. Disease-specific quality of life improved in sum score (effect size, 0.24; p<0.0001) and physical component score (effect size, 0.35; p<0.0001). The latter was inversely correlated to improvement in peak power output (r= -0.31; p<0.05). In patients with stable chronic heart failure, significant improvements in both generic and disease-specific quality of life related to improved exercise tolerance can be achieved within 12 weeks of comprehensive rehabilitation.
Resumo:
Chronic heart failure (CHF) impairs quality of life (QoL) much stronger than other chronic diseases. The objective of this evaluation was to assess the effect of a new integrated comprehensive outpatients rehabilitation program on somatic parameters and quality of life in 51 patients with stable CHF. After rehabilitation, left ventricular ejection fraction, NYHA class, and parameters of sub-maximum and maximum exercise capacity improved significantly between 11 and 20%, and 6-minute walking distance by 58% on average (p < 0.0001). Non-disease specific QoL (Short Form-36 questionnaire) improved in only 2 of 8 subscales (physical functioning [effect size 0.38, p < 0.001], and role functioning [effect size 0.17, p < 0.05]), and a mental component score [effect size 0.47, p < 0.0001]. Disease-specific QoL (Minnesota Living with Heart Failure questionnaire) improved in terms of sum score [effect size 0.24, p < 0.0001], and physical component score [effect size 0.35, p < 0.0001]. Improvement in exercise capacity correlated significantly with improvements in parameters of disease-specific QoL.