91 resultados para 4D-CBCT


Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: This report of 2 cases describes the diagnostic procedures used to identify 2 Stafne's bone cavities (SBC) found in unusually anterior locations in the mandible, both mimicking periapical lesions of endodontic origin. METHODS: In the first patient, a 47-year-old man, an SBC was diagnosed in the area of teeth #27, 28, and 29. In the second patient, a 62-year-old man, the SBC was a fortuitous finding, because this patient was referred for dental implant therapy. RESULTS: In both cases, the final diagnosis was achieved by using limited cone beam computed tomography (CBCT) and magnetic resonance imaging (MRI). In both patients, the lingual bone cavity was found to be occupied by accessory salivary gland tissue. CONCLUSIONS: The combination of CBCT and MRI as noninvasive diagnostic techniques seems ideal to avoid surgical explorations, incisional biopsies, or enucleations of the lesion for diagnostic purposes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIM: To compare intraoral occlusal (OC) and periapical (PA) radiographs vs. limited cone beam computed tomography (CBCT) in diagnosing root-fractured permanent teeth. MATERIAL AND METHODS: In 38 patients (mean age 24 years, range 8-52 years) with 44 permanent teeth with horizontal root fractures, intraoral radiographs (PA and OC) and limited CBCT were used to evaluate the location (apical, middle, cervical third of the root) and angulation of the fracture line. Furthermore, the conventional radiographs and CBCT images were compared for concordance of fracture location. RESULTS: In the PA and OC radiographs, 28 fractures (63.6%) were located in the middle third of the root, 11 (25.0%) in the apical third and 5 (11.4%) in the cervical third. The PA/OC radiographs and the sagittal CBCT images (facial aspect) yielded the same level of root fracture in 70.5% of cases (31 teeth; 95% CI: 54.1-82.7%). The PA/OC radiographs and sagittal CBCT images (palatal aspect) showed the same level of root fracture in 31.8% of cases. There was a statistically significant association between the angle at which the root fracture line intersected the axis of the tooth and the level of root fracture in the facial aspect of the sagittal CBCT images. CONCLUSIONS: The diagnosis of the location and angulation of root fractures based on limited CBCT imaging differs significantly from diagnostic procedures based on intraoral radiographs (PA/OC) alone. The clinical significance for treatment strategies and for the prognosis of root-fractured teeth has to be addressed in future studies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate whether measurements performed on conventional frontal radiographs are comparable to measurements performed on three-dimensional (3D) models of human skulls derived from cone beam computed tomography (CBCT) scans and if the latter can be used in longitudinal studies. Cone beam computed tomography scans and conventional frontal cephalometric radiographs were made of 40 dry human skulls. From the CBCT scan a 3D model was constructed. Standard cephalometric software was used to identify landmarks and to calculate ratios and angles. The same operator identified 10 landmarks on both types of cephalometric radiographs, and on all images, five times with a time interval of 1 wk. Intra-observer reliability was acceptable for all measurements. There was a statistically significant and clinically relevant difference between measurements performed on conventional frontal radiographs and on 3D CBCT-derived models of the same skull. There was a clinically relevant difference between angular measurements performed on conventional frontal cephalometric radiographs, compared with measurements performed on 3D models constructed from CBCT scans. We therefore recommend that 3D models should not be used for longitudinal research in cases where there are only two-dimensional (2D) records from the past.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluated whether measurements on conventional frontal radiographs are comparable with measurements on cone beam computed tomography (CBCT)-constructed frontal cephalometric radiographs taken from dry human skulls. CBCT scans and conventional frontal cephalometric radiographs were made of 40 dry skulls. With I-Cat Vision((R)) software, a cephalometric radiograph was constructed from the CBCT scan. Standard cephalometric software was used to identify landmarks and calculate ratios and angles. The same operator identified 10 landmarks on both types of cephalometric radiographs on all Images 5 times with a time-interval of 1 week. Intra-observer reliability was acceptable for all measurements. The reproducibility of the measurements on the frontal radiographs obtained from the CBCT scans was higher than those on conventional frontal radiographs. There is a statistically significant and clinically relevant difference between measurements on conventional and constructed frontal radiographs. There is a clinically relevant difference between angular measurements performed on conventional frontal cephalometric radiographs, compared with measurements on frontal cephalometric radiographs constructed from CBCT scans, owing to different positioning of patients in both devices. Positioning of the patient in the CBCT device appears to be an important factor in cases where a 2D projection of the 3D scan is made.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE The purpose of the present study was to evaluate the thickness and anatomic characteristics of the sinus membrane using cone beam computed tomography (CBCT) in patients evaluated for implant surgery in the posterior maxilla. MATERIALS AND METHODS The study included 131 consecutive patients referred for dental implant placement in the posterior maxilla. A total of 138 CBCT images was obtained using fields of view of 4 × 4 cm, 6 × 6 cm, or 8 × 8 cm. Reformatted sagittal CBCT slices were analyzed with regard to the thickness and characteristics of the sinus membrane at single-tooth gaps in the posterior maxilla. Factors that might influence the dimensions of the sinus membrane, such as age, sex, endodontic status, and the season, were analyzed. RESULTS The mean thickness of the maxillary sinus mucosa varied between 2.1 and 2.69 mm in the three locations analyzed. Fewer than half of the evaluated sinuses exhibited a healthy mucosa (49 of 138, or 35.51%). Most of the pathologic findings were flat, shallow thickenings (63 of 138, or 45.65%). Sex did not influence the thickness of the sinus membrane at the root tips of the premolars or at single-tooth gaps, but there was a statistically significant correlation in the region of the maxillary molars. No other evaluated factors had a statistically significant effect on the dimensions of the antral mucosa. CONCLUSIONS In the present study, sex was the only factor influencing the dimension of the sinus membrane, whereas patient age, season, and the endodontic status of neighboring teeth had no significant effect on the thickness of the antral mucosa. Future studies should address which types of mucosal thickening require interdisciplinary therapy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this prospective case series study, 20 patients with an implant-borne single crown following early implant placement with simultaneous contour augmentation were followed for 6 years. Clinical, radiologic, and esthetic parameters were assessed. In addition, cone beam computed tomography (CBCT) was used at 6 years to examine the facial bone wall. During the study period, all 20 implants were successfully integrated, and the clinical parameters remained stable over time. Pleasing esthetic outcomes were noted, as assessed by the pink esthetic scores. None of the implants developed mucosal recession of 1 mm or more. The periapical radiographs yielded stable peri-implant bone levels, with a mean DIB of 0.44 mm at 6 years. The CBCT scans showed that all 20 implants had a detectable facial bone wall at 6 years, with a mean thickness of around 1.9 mm. In summary, this prospective case series study demonstrated stable peri-implant hard and soft tissues for all 20 implants, and pleasing esthetic outcomes overall. The follow-up of 6 years confirmed that the risk for mucosal recession is low with early implant placement. In addition, contour augmentation with guided bone regeneration (GBR) was able to establish and maintain a facial bone wall in all 20 patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Early implant placement with simultaneous contour augmentation is documented with short- and medium-term studies. The long-term stability of contour augmentation is uncertain. METHODS In this prospective, cross-sectional study, 41 patients with an implant-borne single crown were examined twice, in 2006 and 2010. Clinical, radiologic, and esthetic parameters were assessed at both examinations. In addition, a cone beam computed tomographic (CBCT) image was obtained during the second examination to assess the dimensions of the facial bone wall. RESULTS All 41 implants demonstrated ankylotic stability without signs of peri-implant infection at both examinations. The clinical parameters remained stable over time. Satisfactory esthetic outcomes were noted, as assessed by the pink and white esthetic score (PES/WES) indices. Overall, the PES scores were slightly higher than the WES scores. None of the implants developed mucosal recession over time, as confirmed by values of the distance between implant shoulder and mucosal margin and cast measurements. The periapical radiographs yielded stable peri-implant bone levels, with a mean distance between implant shoulder and first visible bone-implant contact value of 2.18 mm. The CBCT analysis demonstrated a mean thickness of the facial bone wall ≈2.2 mm. In two implants (4.9%) no facial bone wall was detectable radiographically. CONCLUSIONS This prospective cross-sectional study demonstrates stable peri-implant hard and soft tissues for all 41 implants examined and satisfactory esthetic outcomes overall. The follow-up of 5 to 9 years confirmed again that the risk for mucosal recession is low with early implant placement. In addition, contour augmentation with guided bone regeneration was able to establish and maintain a facial bone wall in 95% of patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The study analyses the location of impacted maxillary canines and factors influencing root resorptions of adjacent teeth using cone-beam computed tomography (CBCT). In addition, the interrater reliability between observers of two different dental specialties for radiographic parameters will be evaluated. CBCT images of patients who were referred for radiographic localization of impacted maxillary canines and/or suspicion of root resorptions of adjacent teeth were included. The study analysed the exact three-dimensional location of the impacted canines in the anterior maxilla, frequency and extent of root resorptions, and potential influencing factors. To assess interrater agreement, Cohen's correlation parameters were calculated. This study comprises 113 patients with CBCT scans, and 134 impacted canines were analysed retrospectively. In the patients evaluated, 69 impacted canines were located palatally (51.49 per cent), 41 labially (30.60 per cent), and 24 (17.91 per cent) in the middle of the alveolar process. Root resorptions were found in 34 lateral incisors (25.37 per cent), 7 central incisors (5.22 per cent), 6 first premolars (4.48 per cent), and 1 second premolar (0.75 per cent). There was a significant correlation between root resorptions on adjacent teeth and localization of the impacted canine in relation to the bone, as well as vertical localization of the canine. Interrater agreement showed values of 0.546-0.877. CBCT provides accurate information about location of the impacted canine and prevalence and degree of root resorption of neighbouring teeth with high interrater correlation. This information is of great importance for surgeons and orthodontists for accurate diagnostics and interdisciplinary treatment planning.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION The aims of this study were to compare lateral cephalograms with other radiologic methods for diagnosing suspected fusions of the cervical spine and to validate the assessment of congenital fusions and osteoarthritic changes against the anatomic truth. METHODS Four cadaver heads were selected with fusion of vertebrae C2 and C3 seen on a lateral cephalogram. Multidetector computed tomography (MDCT) and cone-beam computed tomography (CBCT) were performed and assessed by 5 general radiologists and 5 oral radiologists, respectively. Vertebrae C2 and C3 were examined for osseous fusions, and the left and right facet joints were diagnosed for osteoarthritis. Subsequently, the C2 and C3 were macerated and appraised by a pathologist. Descriptive analysis was performed, and interrater agreements between and within the groups were computed. RESULTS All macerated specimens showed osteoarthritic findings of varying degrees, but no congenital bony fusion. All observers agreed that no fusion was found on MDCT or CBCT. They disagreed on the prevalence of osteoarthritic deformities (general radiologists/MDCT, 100%; oral radiologists/CBCT, 93.3%) and joint space assessment in the facet joints (kappa = 0.452). The agreement within the rater groups differed considerably (general radiologists/MDCT, kappa = 0.612; oral radiologists/CBCT, kappa = 0.240). CONCLUSIONS Lateral cephalograms do not provide dependable data to assess the cervical spine for fusions and cause false-positive detections. Both MDCT interpreted by general radiologists and CBCT interpreted by oral radiologists are reliable methods to exclude potential fusions. Degenerative osteoarthritic changes are diagnosed more accurately and consistently by general radiologists evaluating MDCT.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to analyze the width and height of edentulous sites in the posterior maxilla using cone beam computed tomography (CBCT) images from patients referred for implant therapy. A total of 122 CBCT scans were included in the analysis, resulting in a sample size of 252 edentulous sites. The orofacial crest width was measured in coronal slices, perpendicular to the alveolar ridge. The bone height was analyzed in the respective sagittal slices. Additionally, the following secondary outcome parameters were evaluated: the morphology of the sinus floor, the presence of septa in the maxillary sinus, and the thickness of the sinus membrane. The mean crest width for all analyzed sites was 8.28 mm, and the mean bone height was 7.22 mm. The percentage of patients with a crest width of less than 6 mm was 27% in premolar sites and 7.8% in molar sites. The bone height decreased from premolar to molar areas, with a high percentage of first and second molar sites exhibiting a bone height of less than 5 mm (54.12% and 44.64%, respectively). Regarding the morphology of the sinus floor, 53% of the edentulous sites exhibited a flat configuration. A septum was present in 67 edentulous sites (26.59%). Analysis of the sinus membrane revealed 88 sites (34.9%) with increased mucosal thickness (> 2 mm). For the crest width, the location of the edentulous site and the morphology of the sinus floor were both statistically significant variables. For the crest width and mean bone height, the location of the edentulous site and the morphology of the sinus floor were both statistically significant variables. The study confirmed that a high percentage of edentulous sites in the posterior maxilla do require sinus floor elevation to allow the placement of dental implants. Therefore, a detailed three-dimensional radiograph using CBCT is indicated in most patients for proper treatment planning.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION The mental foramen (MF) is an important landmark in dentistry. Knowledge of its position is central to perform block anesthesia of the mental nerve or to avoid nerve damage during surgical procedures in the premolar area of the mandible. The present radiographic study aimed at evaluating the location and dimension of the MF and measuring distances to neighboring structures by using limited cone-beam computed tomography (CBCT). METHODS Sagittal, axial, and coronal CBCT images of 142 patients (26 bilateral and 116 unilateral cases) were retrospectively screened to determine the location of the MF with respect to adjacent teeth and to take linear measurements of the size of the MF and its distances to the upper and lower borders of the mandible. In addition, the course and angulation of the mental canal exiting the MF were assessed. RESULTS The majority of MF (56%) were located apically between the 2 premolars, and another 35.7% of MF were positioned below the second premolar. On average, the MF was localized 5.0 mm from the closest root of the adjacent tooth (range, 0.3-9.8 mm). The mean size of the MF showed a height of 3.0 mm and a length of 3.2 mm; however, individual cases showed large differences in height (1.8-5.1 mm) and in length (1.8-5.5 mm). All mental canals exiting the MF demonstrated an upward course in the coronal plane, with 70.1% of the mental canal presenting an anterior loop (AL) in the axial view. The mean extension of AL in cases with an AL was 2.3 mm. CONCLUSIONS This study is consistent with previous radiographic studies regarding size and location of MF and distances between MF and adjacent anatomic structures. The assessed bilateral cases showed a high intraindividual concordance for certain features when comparing right and left sides.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Since the introduction of cone beam computed tomography (CBCT), this 3-dimensional diagnostic imaging technique has been established in a growing number of fields in dental medicine. It has become an important tool for both diagnosis and treatment planning, and is also able to support endodontic treatments. However, the higher effective dose of ionizing radiation compared to conventional 2-dimensional radiographs is not justifiable in every case. CBCT allows for a more precise diagnosis of periapical lesions, root fractures as well as external and internal resorptions. Concerning the utility of CBCT in treatment planning decisions, the gain of information through 3-dimensional imaging for any of these pathologies has to be evaluated carefully on an individual basis. Moreover, radioopaque materials such as root canal filling and posts often create artefacts, which may compromise diagnosis. The aim of this review is to summarize the possibilities and limits of CBCT imaging in endodontology as well as introduce guidelines for daily clinical practice. Furthermore, the article presents possible therapeutic advantages of preexisting CBCT scans for root canal treatments.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE The anterior maxilla, sometimes also called premaxilla, is an area frequently requiring surgical interventions. The objective of this observational study was to identify and assess accessory bone channels other than the nasopalatine canal in the anterior maxilla using limited cone beam computed tomography (CBCT). METHODS A total of 176 cases fulfilled the inclusion criteria comprising region of interest, quality of CBCT image, and absence of pathologic lesions or retained teeth. Any bone canal with a minimum diameter of 1.00 mm other than the nasopalatine canal was analyzed regarding size, location, and course, as well as patient gender and age. RESULTS A total of 67 accessory canals ≥1.00 mm were found in 49 patients (27.8%). A higher frequency of accessory canals was observed in males (33.0%) than in females (22.7%) (p = 0.130). Accessory canals occurred more frequently in older rather than younger patients (p = 0.115). The mean diameter of accessory canals was 1.31 ± 0.26 mm (range 1.01-2.13 mm). Gender and age did not significantly influence the diameter. Accessory canals were found palatal to all anterior teeth, but most frequently palatal to the central incisors. In 56.7%, the accessory canals curved superolaterally and communicated with the ipsilateral alveolar extension of the canalis sinuosus. CONCLUSIONS The study confirms the presence of bone channels within the anterior maxilla other than the nasopalatine canal. More than half of these accessory bone canals communicated with the canalis sinuosus. From a clinical perspective, studies are needed to determine the content of these accessory canals.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE To investigate the adequacy of potential sites for insertion of orthodontic mini-implants (OMIs) in the anterior alveolar region (delimited by the first premolars) through a systematic review of studies that used computed tomography (CT) or cone beam CT (CBCT) to assess anatomical hard tissue parameters, such as bone thickness, available space, and bone density. MATERIALS AND METHODS MEDLINE, EMBASE, and the Cochrane Database of Systematic Reviews were searched to identify all relevant papers published between 1980 and September 2011. An extensive search strategy was performed that included the key words "computerized (computed) tomography" and "mini-implants." Information was extracted from the eligible articles for three anatomical areas: maxillary anterior buccal, maxillary anterior palatal, and mandibular anterior buccal. Quantitative data obtained for each anatomical variable under study were evaluated qualitatively with a scoring system. RESULTS Of the 790 articles identified by the search, 8 were eligible to be included in the study. The most favorable area for OMI insertion in the anterior maxilla (buccally and palatally) and mandible is between the canine and the first premolar. The best alternative area in the maxilla (buccally) and the mandible is between the lateral incisor and the canine, while in the maxillary palatal area it is between the central incisors or between the lateral incisor and the canine. CONCLUSIONS Although there is considerable heterogeneity among studies, there is a good level of agreement regarding the optimal site for OMI placement in the anterior region among investigations of anatomical hard tissue parameters based on CT or CBCT scans. In this context, the area between the lateral incisor and the first premolar is the most favorable. However, interroot distance seems to be a critical factor that should be evaluated carefully.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE Images from computed tomography (CT), combined with navigation systems, improve the outcomes of local thermal therapies that are dependent on accurate probe placement. Although the usage of CT is desired, its availability for time-consuming radiological interventions is limited. Alternatively, three-dimensional images from C-arm cone-beam CT (CBCT) can be used. The goal of this study was to evaluate the accuracy of navigated CBCT-guided needle punctures, controlled with CT scans. METHODS Five series of five navigated punctures were performed on a nonrigid phantom using a liver specific navigation system and CBCT volumetric dataset for planning and navigation. To mimic targets, five titanium screws were fixed to the phantom. Target positioning accuracy (TPECBCT) was computed from control CT scans and divided into lateral and longitudinal components. Additionally, CBCT-CT guidance accuracy was deducted by performing CBCT-to-CT image coregistration and measuring TPECBCT-CT from fused datasets. Image coregistration was evaluated using fiducial registration error (FRECBCT-CT) and target registration error (TRECBCT-CT). RESULTS Positioning accuracies in lateral directions pertaining to CBCT (TPECBCT = 2.1 ± 1.0 mm) were found to be better to those achieved from previous study using CT (TPECT = 2.3 ± 1.3 mm). Image coregistration error was 0.3 ± 0.1 mm, resulting in an average TRE of 2.1 ± 0.7 mm (N = 5 targets) and average Euclidean TPECBCT-CT of 3.1 ± 1.3 mm. CONCLUSIONS Stereotactic needle punctures might be planned and performed on volumetric CBCT images and controlled with multidetector CT with positioning accuracy higher or similar to those performed using CT scanners.