60 resultados para weak instruments


Relevância:

20.00% 20.00%

Publicador:

Resumo:

What characterizes micropollution as a policy problem and which policy instruments are adequate to regulate micropollution, given the specific problem features? In this article, problem characteristics of micropollution are systematically analyzed and linked to potential policy solutions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rumination und Suppression sind 2 maladaptive Emotionsregulationsstrategien, die im Zusammenhang mit pathologischem Verhalten wie übermäßigem Essen oder Trinken stehen. Ein Messinstrument, welches beide Strategien in Kurzform erfasst, fehlt bisher. Der RS-8 erfasst mit 8 Items die beiden Dimensionen Rumination und Suppression. Anhand von 2 klinischen (Patienten mit Alkoholabhängigkeit [n = 79], Patienten mit Adipositas [n = 53]) und einer nichtklinischen Stichprobe (n = 133) wurde die psychometrische Qualität der Skala überprüft. Die Ergebnisse zeigen, dass der RS-8 ein valides und reliables Messinstrument ist. Die interne Konsistenz kann als gut und die faktorielle Validität als sehr gut bewertet werden. Der RS-8 ist ein ökonomisches Screening-Instrument, welches bei klinischen und nicht-klinischen Stichproben eingesetzt werden kann.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main goal of the AEgIS experiment at CERN is to test the weak equivalence principle for antimatter. We will measure the Earth ' s gravitational acceleration g with antihydrogen atoms being launched in a horizontal vacuum tube and traversing a moiré de fl ectometer. We intend to use a position sensitive device made of nuclear emulsions (combined with a time-of- fl ight detector such as silicon μ strips) to measure precisely their annihilation points at the end of the tube. The goal is to determine g with a 1% relative accuracy. In 2012 we tested emulsion fi lms in vacuum and at room temperature with low energy antiprotons from the CERN antiproton decelerator. First results on the expected performance for AEgIS are presented

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on a new measurement of the neutron beta-asymmetry parameter A with the instrument \perkeo. Main advancements are the high neutron polarization of P=99.7(1) from a novel arrangement of super mirror polarizers and reduced background from improvements in beam line and shielding. Leading corrections were thus reduced by a factor of 4, pushing them below the level of statistical error and resulting in a significant reduction of systematic uncertainty compared to our previous experiments. From the result A0=−0.11996(58), we derive the ratio of the axial-vector to the vector coupling constant λ=gA/gV=−1.2767(16)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The reliability of millimeter and sub-millimeter wave radiometer measurements is dependent on the accuracy of the loads they employ as calibration targets. In the recent past on-board calibration loads have been developed for a variety of satellite remote sensing instruments. Unfortunately some of these have suffered from calibration inaccuracies which had poor thermal performance of the calibration target as the root cause. Stringent performance parameters of the calibration target such as low reflectivity, high temperature uniformity, low mass and low power consumption combined with low volumetric requirements remain a challenge for the space instrument developer. In this paper we present a novel multi-layer absorber concept for a calibration load which offers an excellent compromise between very good radiometric performance and temperature uniformity and the mass and volumetric constraints required by space-borne calibration targets.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Food security is important. A rising world population coupled with climate change creates growing pressure on global world food supplies. States alleviate this pressure domestically by attracting agri-foreign direct investment (agri-FDI). This is a high-risk strategy for weak states: the state may gain valuable foreign currency, technology and debt-free growth; but equally, investors may fail to deliver on their commitments and exploit weak domestic legal infrastructure to ‘grab’ large areas of prime agricultural land, leaving only marginal land for domestic production. A net loss to local food security and to the national economy results. This is problematic because the state must continue to guarantee its citizens’ right to food and property. Agri-FDI needs close regulation to maximise its benefit. This article maps the multilevel system of governance covering agri-FDI. We show how this system creates asymmetric rights in favour of the investor to the detriment of the host state’s food security and how these problems might be alleviated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE Fractured endodontic instruments inhibit optimal cleaning and filling of dental root canals, which may result in a less favorable prognosis for the tooth. Several techniques are available to remove fractured instruments; however, healthy tooth substance often must be destroyed in the process. This study was intended to evaluate Nd:YAG laser treatment as a method to remove fractured stainless steel instruments without destroying healthy tooth substance. METHOD AND MATERIALS Stainless steel endodontic instruments were fractured in 33 unprocessed root canals of mandibular central and lateral incisors and premolars in vitro. A brass tube charged with solder was placed at the coronal end of the fractured instrument and laser energy was used to melt the solder, connecting the fractured instrument with the brass tube. The success rates of connecting and removal of fractured instruments from the root channel were recorded for each case. RESULTS Connecting was achieved in every case in which more than 1.5 mm of the fractured instrument was tangible (22 out of 22). In cases where less than 1.5 mm was tangible, the rate for successful connection decreased to 4 out of 11 (36.4%). Fractured endodontic instruments were removed successfully in 17 out of 22 cases (77.3%) in which more than 1.5 mm was tangible. If less than 1.5 mm was tangible, the removal success rate decreased to 3 out of 11 cases (27.3%). CONCLUSION Our data support Nd:YAG laser-mediated connecting of a brass tube to a fractured endodontic instrument as a feasible and tissue conserving removal approach when more than 1.5 mm of the instrument is tangible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We tested a core assumption of the bidirectional model of executive function (EF) (Blair & Ursache, 2011) indicating that EF is dependent on arousal. From a bottom-up perspective the performance on EF tasks is assumed to be curvilinearly related to arousal, with very high or low levels of arousal impairing EF. N = 107 4-and 6-year-olds’ performance on EF tasks was explored as a function of a weak stress manipulation aiming to raise children’s emotional arousal. EF (Stroop, Flanker, Go/no-go, and Backwards Color Recall) was assessed and stress was induced in half of the children by imposing a mild social evaluative threat. Furthermore, children’s temperament was assessed as a potential moderator. We found that stress effects on children’s EF performance were moderated by age and temperament: 4-year-olds with high Inhibitory Control and high Attentional Focusing were negatively affected by the stressor. However, it is unclear whether these effects were mediated by self-reported arousal. Our findings disconfirmed the hypotheses that adverse effects of the stressor are particularly high in children high on emotional reactivity aspects of temperament and low on self-regulatory aspects of temperament. Further, 6-year-olds did not show any stress effects. Results will be discussed within the framework of the Yerkes-Dodson law and with regard to stress manipulations in children.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A measurement of the B 0 s →J/ψϕ decay parameters, updated to include flavor tagging is reported using 4.9  fb −1 of integrated luminosity collected by the ATLAS detector from s √ =7  TeV pp collisions recorded in 2011 at the LHC. The values measured for the physical parameters are ϕ s 0.12±0.25(stat)±0.05(syst)  rad ΔΓ s 0.053±0.021(stat)±0.010(syst)  ps −1 Γ s 0.677±0.007(stat)±0.004(syst)  ps −1 |A ∥ (0)| 2 0.220±0.008(stat)±0.009(syst) |A 0 (0)| 2 0.529±0.006(stat)±0.012(syst) δ ⊥ =3.89±0.47(stat)±0.11(syst)  rad where the parameter ΔΓ s is constrained to be positive. The S -wave contribution was measured and found to be compatible with zero. Results for ϕ s and ΔΓ s are also presented as 68% and 95% likelihood contours, which show agreement with the Standard Model expectations.