41 resultados para visual methods


Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND It has been suggested that sleep apnea syndrome may play a role in normal-tension glaucoma contributing to optic nerve damage. The purpose of this study was to evaluate if optic nerve and visual field parameters in individuals with sleep apnea syndrome differ from those in controls. PATIENTS AND METHODS From the records of the sleep laboratory at the University Hospital in Bern, Switzerland, we recruited consecutive patients with severe sleep apnea syndrome proven by polysomnography, apnea-hypopnea index >20, as well as no sleep apnea controls with apnea-hypopnea index <10. Participants had to be unknown to the ophtalmology department and had to have no recent eye examination in the medical history. All participants underwent a comprehensive eye examination, scanning laser polarimetry (GDx VCC, Carl Zeiss Meditec, Dublin, California), scanning laser ophthalmoscopy (Heidelberg Retina Tomograph II, HRT II), and automated perimetry (Octopus 101 Programm G2, Haag-Streit Diagnostics, Koeniz, Switzerland). Mean values of the parameters of the two groups were compared by t-test. RESULTS The sleep apnea group consisted of 69 eyes of 35 patients; age 52.7 ± 9.7 years, apnea-hypopnea index 46.1 ± 24.8. As controls served 38 eyes of 19 patients; age 45.8 ± 11.2 years, apnea-hypopnea index 4.8 ± 1.9. A difference was found in mean intraocular pressure, although in a fully overlapping range, sleep apnea group: 15.2 ± 3.1, range 8-22 mmHg, controls: 13.6 ± 2.3, range 9-18 mmHg; p<0.01. None of the extended visual field, optic nerve head (HRT) and retinal nerve fiber layer (GDx VCC) parameters showed a significant difference between the groups. CONCLUSION Visual field, optic nerve head, and retinal nerve fiber layer parameters in patients with sleep apnea did not differ from those in the control group. Our results do not support a pathogenic relationship between sleep apnea syndrome and glaucoma.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE Visual hallucinations (VHs) are a very personal experience, and it is not clear whether information about them is best provided by informants or patients. Some patients may not share their hallucinatory experiences with caregivers to avoid distress or for fear of being labeled insane, and others do not have informants at all, which limits the use of informant-based questionnaires. The aim of this study was to compare patient and caregiver views about VHs in Parkinson disease (PD), using the North-East Visual Hallucinations Interview (NEVHI). METHODS Fifty-nine PD patient-informant pairs were included. PD patients and informants were interviewed separately about VHs using the NEVHI. Informants were additionally interviewed using the four-item version of the Neuropsychiatric Inventory. Inter-reliability and concurrent validity of the different measures were compared. RESULTS VHs were more commonly reported by patients than informants. The inter-rater agreement between NEVHI-patient and NEVHI-informant was moderate for complex VHs (Cohen's kappa = 0.44; 95% confidence interval [CI]: 0.13-0.75; t = 3.43, df = 58, p = 0.001) and feeling of presence (Cohen's kappa = 0.35; 95% CI: 0.00-0.70; t = 2.75, df = 58, p = 0.006), but agreement was poor for illusions (Cohen's kappa = 0.25; 95% CI: -0.07-0.57; t = 2.36, df = 58, p = 0.018) and passage hallucinations (Cohen's kappa = 0.16; 95% CI: -0.04-0.36; t = 2.26, df = 58, p = 0.024). CONCLUSION When assessing VHs in PD patients, it is best to rely on patient information, because not all patients share the details of their hallucinations with their caregivers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND The aim of this study was to evaluate imaging-based response to standardized neoadjuvant chemotherapy (NACT) regimen by dynamic contrast-enhanced magnetic resonance mammography (DCE-MRM), whereas MR images were analyzed by an automatic computer-assisted diagnosis (CAD) system in comparison to visual evaluation. MRI findings were correlated with histopathologic response to NACT and also with the occurrence of metastases in a follow-up analysis. PATIENTS AND METHODS Fifty-four patients with invasive ductal breast carcinomas received two identical MRI examinations (before and after NACT; 1.5T, contrast medium gadoteric acid). Pre-therapeutic images were compared with post-therapeutic examinations by CAD and two blinded human observers, considering morphologic and dynamic MRI parameters as well as tumor size measurements. Imaging-assessed response to NACT was compared with histopathologically verified response. All clinical, histopathologic, and DCE-MRM parameters were correlated with the occurrence of distant metastases. RESULTS Initial and post-initial dynamic parameters significantly changed between pre- and post-therapeutic DCE-MRM. Visually evaluated DCE-MRM revealed sensitivity of 85.7%, specificity of 91.7%, and diagnostic accuracy of 87.0% in evaluating the response to NACT compared to histopathology. CAD analysis led to more false-negative findings (37.0%) compared to visual evaluation (11.1%), resulting in sensitivity of 52.4%, specificity of 100.0%, and diagnostic accuracy of 63.0%. The following dynamic MRI parameters showed significant associations to occurring metastases: Post-initial curve type before NACT (entire lesions, calculated by CAD) and post-initial curve type of the most enhancing tumor parts after NACT (calculated by CAD and manually). CONCLUSIONS In the accurate evaluation of response to neoadjuvant treatment, CAD systems can provide useful additional information due to the high specificity; however, they cannot replace visual imaging evaluation. Besides traditional prognostic factors, contrast medium-induced dynamic MRI parameters reveal significant associations to patient outcome, i.e. occurrence of distant metastases.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Central and peripheral vision is needed for object detection. Previous research has shown that visual target detection is affected by age. In addition, light conditions also influence visual exploration. The aim of the study was to investigate the effects of age and different light conditions on visual exploration behavior and on driving performance during simulated driving. METHODS: A fixed-base simulator with 180 degree field of view was used to simulate a motorway route under daylight and night conditions to test 29 young subjects (25-40 years) and 27 older subjects (65-78 years). Drivers' eye fixations were analyzed and assigned to regions of interests (ROI) such as street, road signs, car ahead, environment, rear view mirror, side mirror left, side mirror right, incoming car, parked car, road repair. In addition, lane-keeping and driving speed were analyzed as a measure of driving performance. RESULTS: Older drivers had longer fixations on the task relevant ROI, but had a lower frequency of checking mirrors when compared to younger drivers. In both age groups, night driving led to a less fixations on the mirror. At the performance level, older drivers showed more variation in driving speed and lane-keeping behavior, which was especially prominent at night. In younger drivers, night driving had no impact on driving speed or lane-keeping behavior. CONCLUSIONS: Older drivers' visual exploration behavior are more fixed on the task relevant ROI, especially at night, when driving performance becomes more heterogeneous than in younger drivers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: Visual hallucinations (VH) most commonly occur in eye disease (ED), Parkinson’s disease (PD), and Lewy body dementia (LBD). The phenomenology of VH is likely to carry important information about the brain areas within the visual system generating them. Methods: Data from five controlled cross-sectional VH studies (164 controls, 135 ED, 156 PD, 79 (PDD 48 + DLB 31) LBD) were combined and analysed. The prevalence, phenomenology, frequency, duration, and contents of VH were compared across diseases and gender. Results: Simple VH were most common in ED patients (ED 65% vs. LBD 22% vs. PD 9%, Chi-square [χ2] test: χ2=31.43, df=2, p<0.001), whilst complex VH were more common in LBD (LBD 76% vs. ED 38%, vs PD 28%, Chi-square test: χ2=96.80, df=2, p<0.001). The phenomenology of complex VH was different across diseases and gender. ED patients reported more “flowers” (ED 21% vs. LBD 6% vs. PD 0%, Chi-square test: χ2=10.04, df=2, p=0.005) and “body parts” (ED 40% vs. LBD 17% vs. PD 13%, Chi-square test: χ2=11.14, df=2, p=0.004); in contrast LBD patients reported “people” (LBD 85% vs. ED 67% vs. PD 63%, Chi-square test: χ2=6.20, df=2, p=0.045) and “animals/insects” (LBD 50% vs. PD 42% vs. ED 21%, Chi-square test: χ2=9.76, df=2, p=0.008). Males reported more “machines” (13 % vs. 2%, Chi-square test: χ2=6.94, df=1, p=0.008), whilst females reported more “family members/children” (48% vs. 29%, Chi-square test: χ2=5.10, df=1, p=0.024). Conclusions: The phenomenology of VH is likely related to disease specific dysfunctions within the visual system and to past, personal experiences.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Patients with downbeat nystagmus syndrome suffer from oscillopsia, which leads to an unstable visual perception and therefore impaired visual acuity. The aim of this study was to use real-time computer-based visual feedback to compensate for the destabilizing slow phase eye movements. METHODS The patients were sitting in front of a computer screen with the head fixed on a chin rest. The eye movements were recorded by an eye tracking system (EyeSeeCam®). We tested the visual acuity with a fixed Landolt C (static) and during real-time feedback driven condition (dynamic) in gaze straight ahead and (20°) sideward gaze. In the dynamic condition, the Landolt C moved according to the slow phase eye velocity of the downbeat nystagmus. The Shapiro-Wilk test was used to test for normal distribution and one-way ANOVA for comparison. RESULTS Ten patients with downbeat nystagmus were included in the study. Median age was 76 years and the median duration of symptoms was 6.3 years (SD +/- 3.1y). The mean slow phase velocity was moderate during gaze straight ahead (1.44°/s, SD +/- 1.18°/s) and increased significantly in sideward gaze (mean left 3.36°/s; right 3.58°/s). In gaze straight ahead, we found no difference between the static and feedback driven condition. In sideward gaze, visual acuity improved in five out of ten subjects during the feedback-driven condition (p = 0.043). CONCLUSIONS This study provides proof of concept that non-invasive real-time computer-based visual feedback compensates for the SPV in DBN. Therefore, real-time visual feedback may be a promising aid for patients suffering from oscillopsia and impaired text reading on screen. Recent technological advances in the area of virtual reality displays might soon render this approach feasible in fully mobile settings.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES The aim of this in vitro study was to examine the effect of different levels of magnification on the accuracy and reliability of visual caries detection using ICDAS criteria. METHODS Occlusal surfaces of 100 extracted molars were assessed by 14 examiners (3rd and the 4th year dental students and dentists) using no magnification aids, a 2.5× Galilean loupe, a 4.5× Keplerian loupe, or a surgical microscope with 10× magnification. The assessments were repeated on a different day. Sensitivity, specificity, AUC and reliabilities were calculated according to the gold standard of histology. RESULTS We found that with increasing magnification, the number of surfaces rated as "sound" (ICDAS code 0) decreased, while the number of surfaces with a localized enamel breakdown (ICDAS code 3) increased. While the sensitivities increased, the values of the specificities decreased to an unacceptably low level irrespective of the clinical experience of the examiners. CONCLUSIONS ICDAS seems to be optimized for natural vision up to 2.0× magnification and not for high magnifications. The use of powerful magnification in visual caries detection involves the risk of unnecessary and premature invasive treatment. CLINICAL SIGNIFICANCE This paper discusses when it does and does not make sense to use magnification devices for visual caries detection using ICDAS criteria. Strong magnifications should be refrained from for this purpose.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES The aims of the present study in Swiss dental practices were 1) to provide an update on the prevalence of different magnification devices, 2) to examine the relationship between self-assessed and objectively measured visual acuity, and 3) to evaluate the visual performance of dentists in the individually optimized clinical situation of their respective practices. METHODS AND MATERIALS Sixty-nine dentists from 40 randomly selected private practices (n=20, <40 years; n=49, ≥40 years) participated in the study. A questionnaire was provided to evaluate the self-assessed near visual acuity and the experience with magnification devices. The objective near visual acuity was measured under standardized conditions on a negatoscope. The clinical situation, including the use of habitual optical aids, was evaluated with visual tests on a phantom head. RESULTS A total of 64% of the dentists owned a dental loupe: 45% Galilean loupes, 16% Keplerian loupes, and 3% single lens loupes. In total, 19% of the questioned dentists owned a microscope in addition to the loupes. The correlation between the self-assessed and the objective visual performance of the dentists was weak (Spearman rank correlation coefficient=0.25). In the habitual clinical situation, magnification devices (p=0.03) and the dentist's age (p=0.0012) had a significant influence on the visual performance. CONCLUSIONS Many dentists were not aware of their visual handicaps. Optical aids such as loupes or microscopes should be used early enough to compensate for individual or age-related visual deficiencies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This in vivo study aimed to evaluate the influence of contact points on the approximal caries detection in primary molars, by comparing the performance of the DIAGNOdent pen and visual-tactile examination after tooth separation to bitewing radiography (BW). A total of 112 children were examined and 33 children were selected. In three periods (a, b, and c), 209 approximal surfaces were examined: (a) examiner 1 performed visual-tactile examination using the Nyvad criteria (EX1); examiner 2 used DIAGNOdent pen (LF1) and took BW; (b) 1 week later, after tooth separation, examiner 1 performed the second visual-tactile examination (EX2) and examiner 2 used DIAGNOdent again (LF2); (c) after tooth exfoliation, surfaces were directly examined using DIAGNOdent (LF3). Teeth were examined by computed microtomography as a reference standard. Analyses were based on diagnostic thresholds: D1: D 0 = health, D 1 –D 4 = disease; D2: D 0 , D 1 = health, D 2 –D 4 = disease; D3: D 0 –D 2 = health, D 3 , D 4 = disease. At D1, the highest sensitivity/specificity were observed for EX1 (1.00)/LF3 (0.68), respectively. At D2, the highest sensitivity/ specificity were observed for LF3 (0.69)/BW (1.00), respectively. At D3, the highest sensitivity/specificity were observed for LF3 (0.78)/EX1, EX2 and BW (1.00). EX1 showed higher accuracy values than LF1, and EX2 showed similar values to LF2. We concluded that the visual-tactile examination showed better results in detecting sound surfaces and approximal caries lesions without tooth separation. However, the effectiveness of approximal caries lesion detection of both methods was increased by the absence of contact points. Therefore, regardless of the method of detection, orthodontic separating elastics should be used as a complementary tool for the diagnosis of approximal noncavitated lesions in primary molars.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE To assess the visual performance of Swiss hand surgeons in an environment similar to their workplace. The influence of Galilean (lenses only) and Keplerian loupes (lenses and prisms), the surgeon's age, and the credibility of a self-assessment of his or her own optical performance were evaluated. METHODS Sixty-three hand surgeons between 29 and 68 years of age with 70 loupes were included in the study (Galilean n = 35, Keplerian n = 35). The visual performance as surgeons was self-assessed on a modified visual analog scale and objectively measured with miniaturized visual tests in a simulated clinical setting. We evaluated the influence of the optical device by comparing Galilean and Keplerian loupes and the influence of the surgeon's age by comparing 2 subgroups: < 40 years and ≥ 40 years. RESULTS The correlation between self-assessment and objective visual performance was weak, with a Spearman rank correlation coefficient of 0.25. The near visual acuity with habitual optical aids showed considerable variability, with a range of 300% in the dimension of the smallest detected structure. The near visual acuity was significantly lower in the older group ≥ 40 years than in the younger group < 40 years with both Galilean and Keplerian loupes. Keplerian loupes allowed a significantly higher visual performance than Galilean loupes. Surgeons 40 years or older using Keplerian loupes had a similar visual acuity to surgeons younger than 40 years with Galilean loupes. CONCLUSIONS The magnified near vision of hand surgeons showed an important individual variability. Self-assessment was not a valuable instrument for surgeons to estimate their own near vision. Hand surgeons older than 40 years should use higher magnification loupes. TYPE OF STUDY/LEVEL OF EVIDENCE Diagnostic III.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Co-speech gestures are part of nonverbal communication during conversations. They either support the verbal message or provide the interlocutor with additional information. Furthermore, they prompt as nonverbal cues the cooperative process of turn taking. In the present study, we investigated the influence of co-speech gestures on the perception of dyadic dialogue in aphasic patients. In particular, we analysed the impact of co-speech gestures on gaze direction (towards speaker or listener) and fixation of body parts. We hypothesized that aphasic patients, who are restricted in verbal comprehension, adapt their visual exploration strategies. Methods: Sixteen aphasic patients and 23 healthy control subjects participated in the study. Visual exploration behaviour was measured by means of a contact-free infrared eye-tracker while subjects were watching videos depicting spontaneous dialogues between two individuals. Cumulative fixation duration and mean fixation duration were calculated for the factors co-speech gesture (present and absent), gaze direction (to the speaker or to the listener), and region of interest (ROI), including hands, face, and body. Results: Both aphasic patients and healthy controls mainly fixated the speaker’s face. We found a significant co-speech gesture x ROI interaction, indicating that the presence of a co-speech gesture encouraged subjects to look at the speaker. Further, there was a significant gaze direction x ROI x group interaction revealing that aphasic patients showed reduced cumulative fixation duration on the speaker’s face compared to healthy controls. Conclusion: Co-speech gestures guide the observer’s attention towards the speaker, the source of semantic input. It is discussed whether an underlying semantic processing deficit or a deficit to integrate audio-visual information may cause aphasic patients to explore less the speaker’s face. Keywords: Gestures, visual exploration, dialogue, aphasia, apraxia, eye movements